Symmons S-20-0 Service Manual

Page 1
Symmetrix
Lavatory Faucet S-20 Series
Installation and Service Instructions
Installation
Caution: Be sure to turn off hot and cold water supplies before installing or servicing faucet.
1. Loosely install the anchor bar (KN-23), spacer (KN-26) and
nut (L-36) on the mounting bolts and place gasket on base of faucet. Push faucet supplies and anchor bolt/spacer/nut assemblies with gasket through holes in sink. Secure faucet to sink by tightening nuts from underside. (If sink or coun­ter surface is uneven, use putty or sealant to make proper seal under base.)
2. Connect hot supply to le tube and cold supply to right tube using appropriate connectors.
3. Pop-up drain installation: a) Remove pop-up plug, tail piece and ange from the drain
body. Make sure that locknut is threaded all the way down onto the body with at friction washer in middle
and beveled washer on top. b) Apply plumbers putty or sealant to bottom of ange. c) Install drain body through drain opening in lavatory
and screw ange onto the drain body making sure that
the threads are completely engaged for proper sealing
and strength of the connection. Apply joint compound
to all threaded parts to insure proper seal. Apply putty or
teon tape to tail piece before attaching to drain body. d) Tighten locknut to compress the beveled ange evenly
across the bottom of the drain opening taking care not to
over tighten the locknut, causing damage to the lavatory. e) Remove one of two ball washers from inside the
threaded cavity. Insert pop-up plug and pivot rod into
body. Add one ball washer (the second ball washer
should remain inside the body) to the outside of the ball.
Tighten the retaining nut until the ball is seated on the
internal and external ball washers. Note: e pop-up plug can be installed either in the remov-
able or non-removable position, depending on the location
of the hole located in the guide at the bottom of the plug. f) Slide the pivot rod through one side of the spring clip,
then the appropriate adjustment hole and then other
side of the spring clip. g) Insert li rod through faucet housing and the top of the
li strap and secure it in place by tightening the screw. Note: To ensure proper operation of li rod and pop-
up, some adjustment of the linkage may be required.
ere are two possible adjustment points: 1) li strap to
li rod and 2) li strap to pivot rod.
4. It is very important to thoroughly ush the supply lines to prevent foreign matter, i.e. copper chips, sand, stones, etc. from damaging the sealing surfaces of cartridge.
Remove aerator and turn valve handle on to full cold posi-
tion, open cold supply. Without closing, turn handle to full hot and open hot supply. Let water run in hot only and cold only positions long enough to ush supply lines thoroughly. Shut o faucet and replace aerator. Check for leaks.
5. e handle limit stop can be set to limit handle turn to the hot position. e limit mechanism is factory set to allow full handle travel. To adjust the limit stop, turn handle to the full hot position and li handle to open faucet approximately half way to obtain a smooth ow for correct initial temperature measurement.
6. If when faucet is on and in full hot position and water is too hot, remove plug button (KN-157), loosen set screw (L-
22) and remove handle (KN-3RB, KN-3BRB or LN-135). Li limit stop ring (KN-4L) using a small at head screw driver and rotate counter clockwise to lower temperature. If water is not hot enough, rotate clockwise (See Figure 1 on reverse side). Aer correct temperature is achieved, reattach handle, reversing procedure above.
Replacing cartridge (KN-4)
1. Remove plug button (KN-157), loosen set screw (L-22) and remove handle (KN-3RB, KN-3BRB or LN-135).
2. Engage tabs in cartridge wrench (LN-34) with slots in com­pression ring (KN-2) and use screwdriver in wrench holes or pliers on wrench and turn counter clockwise until compres­sion ring engages with cap (LN-8). Continue turning counter clockwise so that cap/ring assembly is removed from the body (LN-371). Remove cartridge and three ring seal (KN-4).
3. Install new cartridge while taking care to maintain position of the three ring seal at the base of the cartridge. Match posts in base of cartridge with alignment holes in valve body during assembly.
4. Reassemble faucet in reverse fashion. read cap onto body rmly by hand. Do not use a wrench which may damage the nish. Tighten compression ring (KN-2) nger tight using the wrench (LN-34) then 1/4 to 1/2 turn further.
5. Set hot water limit stop in accordance with installation step 5 above.
®
Stop limit adjust
Page 2
Dimensions Symmetrix Lavatory Faucet, S-20-2
Note: Dimensions subject to change without notice.
Parts Assembly Symmetrix Lavatory Faucet, S-20 Series
KN-2 Compression ring KN-3RB* Solid handle KN-3BRB* Loop handle KN-4 Cartridge KN-4L Limit stop ring KN-23 Anchor bar (2) KN-26 Mounting spacer (2) KN-157 Plug button LN-8* Valve cap LN-11* Screw (2) LN-15* Aerator without removal key LN-34 Cartridge wrench (not shown) LN-135 6” lever handle with red/blue indicators LN-363* Undercover plate LN-370 Mounting gasket LN-371 Cartridge housing assembly L-22 Set screw L-36 Mounting nut (2) L-42 Nut (2) RL-154* Pop-up drain assembly (complete) P-26 Grid drain assembly (complete)
For Decorative Finish Faucets add sufx to parts marked with an asterisk as follows:
®
Sufx -STN Radiance
Aerator
(ow regulator)
2.2 gpm (8.3L/min) LN-15* LN-101
1.5 gpm (5.7L/min) FLR-110-1.5
1.0 gpm (3.8L/min) FLR-110-1.0 .5 gpm (1.9L/min) ---- LN-100
Removal tool part number, LL-60K
Satin nish
Part Number Standard Vandal Resistant Aerators with removal tool
* * *
----
----
*
Reference
chart
KN-3RB
L-22
KN-157
KN-4L
LN-8
KN-2
Standard aerator
Vandal resistant
removal tool
KN-4
LN-371
LN-363
LN-11
aerator
P-26
KN-3BRB
RL-154
LN-135
optional IPS connections shown
L-42
LN-370
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800)796-6667 Fax: (800)961-962
©2014 Symmons Industries, Inc. Printed in U.S.A. www.symmons.com gethelp@symmons.com ZV-329 REV B 092614
Loading...