Safetymix®
4-521
INSTALLATION INSTRUCTIONS
Product meets ANSI A112.18.1M
Flow rate: 2.5 gpm (9.5 L/min)
INSTALLATION:
1. Mount valve body.
2. Install water supplies to unions on
valve body.
INDIVIDUAL PARTS INDIVIDUAL PARTS COMPOSITE PARTS
CE-12A Lightwall Flange
CE-12C Wall Flange Nut
CE-12H Heavy Duty Wall Flange
CE-25 Stop body(chrome plated) (2)
CE-26 Cap(chrome plated) (2)
CE-26A Cap(chrome plated) (2)
CE-27 Spindle assembly (2)
IH-2 Woodscrew (4)
HP-10 Body cover
HP-10A O-ring
RC-14 Handle
SC-13BPL Dome cover
SC-13C Dial
SC-15A Set screw
SC-18PL Hot washer screw
SC-3 Renewable seat
SC-7 Packing nut
SC-9 Cold washer retainer
SC-10 Hot washer
SC-10A Screws
SC-11 Cold washer
SC-17 Packing
SC-19 Cap gasket
For ADA compliance (Americans with Disabilities Act) consult ADAAG or your state regulations for proper product choice and mounting heights. ADAAG does permit a fixed
shower head mounted 48” above the floor in unmonitored facilities where vandalism
may be a problem.
C-5 Spindle assembly
C-50 Renewable seat socket wrench
KIT-B Washer and gasket kit
SC-2 Cap assembly
SC-3 Renewable seat unit complete
Tools required for installation:
Slotted screwdriver, Phillips screwdriver,
soldering equipment, adjustable wrench,
channel lock pliers, hex socket keys (1/8”
and 3/32”), electric drill with 1/4” drill bit,
HY-50 screwdriver (provided)
CE-25 (2)
SC-3
HP-10A
HP-10
SC-13BPL
SC-13C
SC-18PL
SC-17
SC-7
RC-14
SC-15A
SC-19
SC-26
SC-2
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184
Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Website: www.symmons.com ■ Email: gethelp@symmons.com
SC-9
SC-11
SC-10A
SC-10
CE-12H
CE-12C
CE-12A
IH-2 (4)
CE-27 (2)
CE-26 (2)
CE-26A (2)
C-5
©2007-2015 Symmons Industries, Inc. Printed in U.S.A. ■ ZV-495 REV A ■ 010815