![](/html/18/1833/18332d1079d26524b1126e5f9907b439d28041b0994cd7ccb357e66f8ec11908/bg1.png)
Model
4-458
Levertrol
Diverter Valve 4-458 / 4-460 Series
Installation and Service Instructions
Model numbers
■ 4-458 ....Dual outlet diverter valve
■ 4-458E ..Dual outlet diverter valve; includes spindle
cartridge assembly for attaching dome cover
■ 4-460 ....Triple outlet diverter valve
■ 4-460E ..Triple outlet diverter valve; includes spindle
cartridge assembly for attaching dome cover
Installation Highlights
Note: ese valves are diverter only valves that are used
in combination with a mixing valve. ey do not act as
an ON/OFF and do not control the water temperature.
1. Flush the lines thoroughly before installation to ensure
any debris is removed that could cause damage to the
cartridge.
2. e inlet port is clearly marked with the letter N cast
into the valve body.
3. Keep the plaster guard in place until the nished wall is
complete.
Service
1. Remove handle and dome cover or escutcheon
attached to end of diverter valve.
2. Remove cartridge assembly by using a deep socket
27 mm wrench to loosen and unscrew brass hex nut.
3. Slide cartridge assembly out and remove gasket /
O-ring from diverter body.
4. Gently slide replacement cartridge assembly and gasket
/ O-ring into diverter body.
5. Reassemble the valve by reversing the above removal
instructions
6. Check system for leaks.
®
Model
4-458E
Model
4-460
Model
4-460E
Diverter Models
■
4-458
■
4-460
Slide on type
escutcheon
Model
4-458
shown
Figure 1
Diverter Models
■
4-458E
■
4-460E
Escutcheon
or escutcheon
back plate
Dome cover
Parts Breakdown Levertrol Diverter, 4-458 / 4-458E
Gasket
TT-21A
Important: Do
not plug ports
(Model# 4-458)
Cartridge Assembly
LLD-20
valve body tabs
Model
4-458E
shown
Figure 2
(Model# 4-458E)
Cartridge Assembly
LLD-20E
Note: Use a deep
socket 1-1/8 inch
wrench to remove
and replace
cartridge assembly.
![](/html/18/1833/18332d1079d26524b1126e5f9907b439d28041b0994cd7ccb357e66f8ec11908/bg2.png)
Parts Breakdown Levertrol Diverter, 4-460 / 4-460E
Dimensions Levertrol Triple Output Diverter, 4-460 / 4-460E
nished wall
Hole size
3 " (76mm) min.
3-1/4" (83mm) max.
All ports 1/2" NPT
IN
1-1/8"
29mm
1-5/8"
42mm
nished wall
Hole size
1-5/8" (41mm) min.
1-7/8" (48 mm) max.
All ports 1/2" NPT
IN
1-3/4" (44mm) min.
2-3/4" (70mm) max.
1-11/16"
(42 mm)
1-1/8"
(29 mm)
OUT
OUT
OUT
Diverter Model# 4-460
Diverter Model# 4-460E
OUT
OUT
OUT
see note
*
*
Note: Figure is determined by style of trim attached to
shower valve. See rough-in dimension drawing for shower
valve application with diverter valve.
O-ring
LD-7A
(Model# 4-460)
Cartridge Assembly
LD-7RR
Important: Do
not plug ports
Dimensions Levertrol Dual Output Diverter, 4-458 / 4-458E
Diverter Model# 4-458
nished wall
Hole size
1-3/8 " (35mm) min.
1-7/8" (48mm) max.
2-1/2" (64mm) min.
3" (76mm) max.
All ports 1/2" NPT
OUT
OUT
IN
1-1/4"
(31mm)
1-3/4"
(46mm)
Diverter Model# 4-458E
nished wall
Hole size
3 " (76 mm) min.
3-1/4" (83 mm) max.
Note: Figure is determined by style of trim attached to
*
shower valve. See rough-in dimension drawing for shower
valve application with diverter valve.
(Model# 4-460E)
Cartridge Assembly
LD-7RRE
Note: Use a deep
socket 1-5/16 inch
wrench to remove
and replace
cartridge assembly.
All ports 1/2" NPT
IN
see note
*
OUT
OUT
1-1/4"
31mm
1-3/4"
46mm
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184
Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Website: www.symmons.com ■ Email: gethelp@symmons.com
©2003-2015 Symmons Industries, Inc. Printed in U.S.A. ■ ZV-572 REV A ■ 012215