Symmons 4-458 Service Manual

Model 4-458
Levertrol
Diverter Valve 4-458 / 4-460 Series
Installation and Service Instructions
Model numbers
■ 4-458 ....Dual outlet diverter valve
■ 4-458E ..Dual outlet diverter valve; includes spindle
cartridge assembly for attaching dome cover
■ 4-460 ....Triple outlet diverter valve
■ 4-460E ..Triple outlet diverter valve; includes spindle
cartridge assembly for attaching dome cover
Installation Highlights
Note: ese valves are diverter only valves that are used
in combination with a mixing valve. ey do not act as an ON/OFF and do not control the water temperature.
1. Flush the lines thoroughly before installation to ensure any debris is removed that could cause damage to the cartridge.
2. e inlet port is clearly marked with the letter N cast into the valve body.
3. Keep the plaster guard in place until the nished wall is complete.
Service
1. Remove handle and dome cover or escutcheon attached to end of diverter valve.
2. Remove cartridge assembly by using a deep socket 27 mm wrench to loosen and unscrew brass hex nut.
3. Slide cartridge assembly out and remove gasket / O-ring from diverter body.
4. Gently slide replacement cartridge assembly and gasket / O-ring into diverter body.
5. Reassemble the valve by reversing the above removal instructions
6. Check system for leaks.
®
Model 4-458E
Model 4-460
Model 4-460E
Diverter Models
4-458
4-460
Slide on type escutcheon
Model 4-458 shown
Figure 1
Diverter Models
4-458E
4-460E
Escutcheon or escutcheon back plate
Dome cover
Parts Breakdown Levertrol Diverter, 4-458 / 4-458E
Gasket
TT-21A
Important: Do not plug ports
(Model# 4-458) Cartridge Assembly
LLD-20
valve body tabs
Model 4-458E shown
Figure 2
(Model# 4-458E) Cartridge Assembly
LLD-20E
Parts Breakdown Levertrol Diverter, 4-460 / 4-460E
Dimensions Levertrol Triple Output Diverter, 4-460 / 4-460E
nished wall
Hole size
3 " (76mm) min.
3-1/4" (83mm) max.
All ports 1/2" NPT
IN
1-1/8" 29mm
1-5/8" 42mm
nished wall
Hole size
1-5/8" (41mm) min.
1-7/8" (48 mm) max.
All ports 1/2" NPT
IN
1-3/4" (44mm) min. 2-3/4" (70mm) max.
1-11/16"
(42 mm)
1-1/8" (29 mm)
OUT
OUT
OUT
Diverter Model# 4-460
Diverter Model# 4-460E
OUT
OUT
OUT
see note
*
*
Note: Figure is determined by style of trim attached to shower valve. See rough-in dimension drawing for shower valve application with diverter valve.
O-ring
LD-7A
(Model# 4-460) Cartridge Assembly
LD-7RR
Important: Do not plug ports
Dimensions Levertrol Dual Output Diverter, 4-458 / 4-458E
Diverter Model# 4-458
nished wall
Hole size 1-3/8 " (35mm) min. 1-7/8" (48mm) max.
2-1/2" (64mm) min. 3" (76mm) max.
All ports 1/2" NPT
OUT
OUT
IN
1-1/4"
(31mm)
1-3/4"
(46mm)
Diverter Model# 4-458E
nished wall
Hole size
3 " (76 mm) min.
3-1/4" (83 mm) max.
Note: Figure is determined by style of trim attached to
*
shower valve. See rough-in dimension drawing for shower valve application with diverter valve.
(Model# 4-460E) Cartridge Assembly
LD-7RRE
Note: Use a deep socket 1-5/16 inch wrench to remove and replace cartridge assembly.
All ports 1/2" NPT
IN
see note
*
OUT
OUT
1-1/4"
31mm 1-3/4" 46mm
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621 Website: www.symmons.com Email: gethelp@symmons.com
©2003-2015 Symmons Industries, Inc. Printed in U.S.A. ZV-572 REV A 012215
Loading...