Symmons 2DIVBODYNSSRT Operation & Maintenance Manual

Page 1
2DIVBODYNSSRT
Dual Outlet Diverter, Non-Sharing
Operation & Maintenance Manual
Model Numbers
2DIVBODYNSSRT
Dual Outlet Diverter, Non-Sharing
Warranty
Limited Lifetime - to the original end purchaser in
consumer/residential installations. 5 Years - for industrial/commercial installations. Refer to www.symmons.com/warranty for complete warranty information.
Dimensions
OUTOUT
CC
BB
OUTOUT
ININ
AA
Specification
Dual outlet diverter valve with no shared functionality. Features male 1/2" IPS and 1/2" sweat inlet/outlet connections (in common plane), dened detents, 2 discreet positions and stringer mounts. Components made from lead free metal construction.
Compliance
-ASME A112.18.1/CSA B125.1
Measurements
A 2-5/8", 67 mm
Screwless Escutcheons
DD
EE
B
C
D 5-1/4", 133 mm
E
F See note 1 G 4-7/8", 124 mm
Hole Size
Min. Ø 3", 76 mm
Max. Ø 3-1/4", 83 mm
Screw Escutcheons
Hole Size
Min. Ø 1-3/4", 44 mm
Max. Ø 2", 51 mm
(3x) 1/2" male IPS &
(3x) 1/2" sweat
FF
GG
Notes:
1) Figure is determined by style of trim attached to shower valve. See rough-in dimension drawing for shower valve application with diverter valve.
2) Dimensions subject to change without notice.
Page 2
Parts Breakdown
DIVERTER FUNCTION 1
B
A
B
FROM SHOWER VALVE
G
DIVERTER FUNCTION 2
Replacement Parts
E
C
D
H
I
Item Description Part Number
A B
C Cartridge Extender
D Cartridge RTS-2DIV-NS
B G H
I
Cap Assembly
Spacer
Spacer
1" Cap Extender
1" Cartridge Extender
4" Mounting Screws
RTS-DIVCAP-
NS-SRT
RTS-DIVEXT-
NS-SRT
RTS-DIV-1EXT-
NS
Tools Required
Adjustable
Wrench
Drill (optional)
Plumber Tape
Safety Glasses
Solder
Torch
Important: Cartridge (D) must be installed with arrow facing down.
2
Page 3
Installation
3
2
Important: Do not plug outlet ports. Do not use diverter as shut-off valve.
Important: Do not expose diverter valve to heat for longer than 2 minutes when sweating in copper tubing. Doing so may damage the internal components of the valve and will void the product warranty.
Note: Diverter valve can be installed in wall with shower valve or in an adjoining wall to shower valve.
1) Reference rough-in dimension for shower application with diverter for proper installation of diverter valve.
2) Shut-off water supplies.
3) Position diverter valve (E) so port marked IN is facing down.
E
!
4) Secure stringer mounts on diverter valve (E) to wood blocking for support.
E
5) Sweat 1/2" copper tubing from inlet port on diverter valve to water source. Sweat 1/2" copper tubing from outlet ports to desired accessories.
Optional: Apply plumber tape to male IPS threads on the inlet and outlet ports of diverter valve. Install 1/2"-14 NPT copper ttings to the inlet and outlet ports. Connect outlets to desired accessories.
Operation
Note: Securing stringer mounts is
necessary for applications where PEX, or other non rigid tubing, is used to install diverter valve.
1) Cartridge is factory set to divert to function 1.
POSITION 1
1
6) Turn on water supplies to ush plumbing lines free of debris Check for leaks.
2) Turn handle to position 2 to divert to function 2.
POSITION 2
2
.
3
Page 4
Maintenance (Cartridge Replacement)
1
2
1) Remove cap assembly (A) from diverter valve by turning coun­terclockwise. Remove cartridge extender (C) and cartridge (D).
E
D
A
2
Note: Spacer (B) will be seated
inside cap assembly (A).
C
2)
Inspect cartridge for debris. Replace cartridge if necessary.
3) Orient new cartridge (D) with arrow facing down. Align pegs on cartridge (D) with indents inside diverter valve (E).
D
E
4) Align spindle extender (C) with broach on cartridge (D). Install spindle extender (C) and cap assembly (A) to cartridge (D). Secure cap assembly (A) by turning clockwise.
C
D
1
A
Notes:
1) Use caution not to dislodge
cartridge from valve body when installing cap assembly (A).
2) Tighten cap assembly (A) to
75 ± 5 lbf-in of torque.
Troubleshooting Chart
Problem Cause Solution
Diverter valve will not divert water.
Water is leaking from the face of the
diverter valve.
Diverter trim will not install to diverter
valve.
Foreign matter in water supply may
cause blockages in plumbing lines and
the diverter valve cartridge.
Cap assembly is not fully sealed to
diverter valve.
Diverter valve body rough-in is too
deep.
Remove cartridge from diverter valve.
Flush lines free of foreign matter.
Inspect cartridge for debris. Replace
cartridge if necessary.
Remove cap assembly. Inspect
threads for debris. Reinstall cap
assembly to diverter valve at
lbf-in of torque.
Use RTS-DIV-1EXT-NS to extend
diverter stem 1 inch.
75 ± 5
WARNING: This product can expose you to chemicals including lead, which is known to the state of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621
Copyright © 2019 Symmons Industries, Inc. symmons.com gethelp@symmons.com ZV-3292 REV 0 031919
Loading...