2DIVBODYNSSRT
Dual Outlet Diverter, Non-Sharing
Operation & Maintenance Manual
Model Numbers
2DIVBODYNSSRT
Dual Outlet Diverter, Non-Sharing
Warranty
Limited Lifetime - to the original end purchaser in
consumer/residential installations.
5 Years - for industrial/commercial installations.
Refer to www.symmons.com/warranty for complete
warranty information.
Dimensions
OUTOUT
CC
BB
OUTOUT
ININ
AA
Specification
Dual outlet diverter valve with no shared functionality.
Features male 1/2" IPS and 1/2" sweat inlet/outlet
connections (in common plane), dened detents, 2 discreet
positions and stringer mounts. Components made from
lead free metal construction.
Compliance
-ASME A112.18.1/CSA B125.1
Measurements
A 2-5/8", 67 mm
Screwless Escutcheons
DD
EE
B
C
D 5-1/4", 133 mm
E
F See note 1
G 4-7/8", 124 mm
Hole Size
Min. Ø 3", 76 mm
Max. Ø 3-1/4", 83 mm
Screw Escutcheons
Hole Size
Min. Ø 1-3/4", 44 mm
Max. Ø 2", 51 mm
(3x) 1/2" male IPS &
(3x) 1/2" sweat
FF
GG
Notes:
1) Figure is determined by style of trim attached to shower valve. See rough-in
dimension drawing for shower valve application with diverter valve.
2) Dimensions subject to change without notice.

Parts Breakdown
DIVERTER FUNCTION 1
B
A
B
FROM SHOWER VALVE
G
DIVERTER FUNCTION 2
Replacement Parts
E
C
D
H
I
Item Description Part Number
A
B
C Cartridge Extender
D Cartridge RTS-2DIV-NS
B
G
H
I
Cap Assembly
Spacer
Spacer
1" Cap Extender
1" Cartridge Extender
4" Mounting Screws
RTS-DIVCAP-
NS-SRT
RTS-DIVEXT-
NS-SRT
RTS-DIV-1EXT-
NS
Tools Required
Adjustable
Wrench
Drill (optional)
Plumber Tape
Safety Glasses
Solder
Torch
Important:
Cartridge (D)
must be installed
with arrow
facing down.
2

Installation
Important: Do not plug
outlet ports. Do not use
diverter as shut-off valve.
Important: Do not expose
diverter valve to heat for
longer than 2 minutes when
sweating in copper tubing.
Doing so may damage the
internal components of
the valve and will void the
product warranty.
Note: Diverter valve can be installed
in wall with shower valve or in an
adjoining wall to shower valve.
1) Reference rough-in dimension for
shower application with diverter
for proper installation of diverter
valve.
2) Shut-off water supplies.
3) Position diverter valve (E) so port
marked IN is facing down.
E
!
4) Secure stringer mounts on diverter
valve (E) to wood blocking for
support.
E
5) Sweat 1/2" copper tubing from
inlet port on diverter valve
to water source. Sweat 1/2"
copper tubing from outlet ports
to desired accessories.
Optional: Apply plumber tape to
male IPS threads on the inlet and
outlet ports of diverter valve. Install
1/2"-14 NPT copper ttings to the
inlet and outlet ports. Connect
outlets to desired accessories.
Operation
Note: Securing stringer mounts is
necessary for applications where
PEX, or other non rigid tubing, is
used to install diverter valve.
1) Cartridge is factory set to divert
to function 1.
POSITION 1
1
6) Turn on water supplies to ush
plumbing lines free of debris
Check for leaks.
2) Turn handle to position 2 to divert
to function 2.
POSITION 2
2
.
3

Maintenance (Cartridge Replacement)
1) Remove cap assembly (A) from
diverter valve by turning counterclockwise. Remove cartridge
extender (C) and cartridge (D).
E
D
A
2
Note: Spacer (B) will be seated
inside cap assembly (A).
C
2)
Inspect cartridge for debris.
Replace cartridge if necessary.
3) Orient new cartridge (D) with
arrow facing down. Align pegs on
cartridge (D) with indents inside
diverter valve (E).
D
E
4) Align spindle extender (C) with
broach on cartridge (D). Install
spindle extender (C) and cap
assembly (A) to cartridge (D).
Secure cap assembly (A) by
turning clockwise.
C
D
1
A
Notes:
1) Use caution not to dislodge
cartridge from valve body when
installing cap assembly (A).
2) Tighten cap assembly (A) to
75 ± 5 lbf-in of torque.
Troubleshooting Chart
Problem Cause Solution
Diverter valve will not divert water.
Water is leaking from the face of the
diverter valve.
Diverter trim will not install to diverter
valve.
Foreign matter in water supply may
cause blockages in plumbing lines and
the diverter valve cartridge.
Cap assembly is not fully sealed to
diverter valve.
Diverter valve body rough-in is too
deep.
Remove cartridge from diverter valve.
Flush lines free of foreign matter.
Inspect cartridge for debris. Replace
cartridge if necessary.
Remove cap assembly. Inspect
threads for debris. Reinstall cap
assembly to diverter valve at
lbf-in of torque.
Use RTS-DIV-1EXT-NS to extend
diverter stem 1 inch.
75 ± 5
WARNING: This product can expose you to chemicals including lead, which is known to the state of California to cause cancer, birth defects, or
other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2019 Symmons Industries, Inc. ■ symmons.com ■ gethelp@symmons.com ■ ZV-3292 REV 0 ■ 031919