SurgeX SEQ-1U, SEQ User Manual

SEQ / SEQ-1U
Programmable Sequencer/
Surge Eliminator/Power Conditioner
Software Version: 2.0
© SurgeX | Technical Support: 800-645-9721 | surgex.com
SEQ/SEQ-1U User Manual
Software Version 2.0
© SurgeX | Technical Support: 800-645-9721 | surgex.com Page 2
SEQ/SEQ-1U User Manual
1. Introduction 4
2. Features 3
3. Installation 3
3.1 120 Volt Connections 3
3.2 Remote Control Connections 4
3.2.1 Up/Down Sequence Control Inputs 4
3.2.2 Over-ride Input 5
3.2.3 External LED Connections 5
3.2.4 Confirmation Connection 5
4. Quick Start 6
5. Programming 7
5.1 Power Sequencing Control 7
5.2 Over-ride Control 8
5.3 Front Panel Push Button 8
5.4 12V DC Output 9
5.5 Auxiliary Relay 10
5.6 Out-of-Range AC Voltage Shut Down 10
5.7 Self-Test Failure Shut Down 11
5.8 Restore Functions 11
5.9 Password 11
6. Applications 12
6.1 General Points 12
6.1.1 Controlling the SEQ 12
6.1.2 12V DC Output 12
6.1.3 Auxiliary Relay 13
6.1.4 Over-ride Function 13
6.1.5 Other Functions 13
6.2 Single Unit Systems 14
6.3 Expanded System 15
6.4 Ganged System 18
6.5 Cascaded System 19
7. Troubleshooting 20
8. Error Codes 20
9. Specifications 21
Software Version 2.0
© SurgeX | Technical Support: 800-645-9721 | surgex.com Page 3
SEQ/SEQ-1U User Manual
Sequence Bank A
Sequence Bank
Sequence Bank
Always On
Total SEQ
2 RU 4 4 4 2
14
SEQ-1U
1 RU 2 2 2 2
8

1. Introduction

The SurgeX® SEQ an d SEQ-1U are 120V/20 Amp three-bank AC power sequencers incorporating SurgeX® Advanced Series Mode Federal Commercial Item Description for Endurance.
Model
Bank C (which is next to the two always-on receptacles on the rear panel) can itself be configured to be always on, increasing the number of always-on receptacles.
SurgeX ICE inrush currents from large loads such as amplifiers. With SurgeX ICE account when designing the AC power for a system, and special time -delay ci rcuit breakers are not required: you only need to ensure that the steady-state currents of all products plugged into the SEQ are within the 20 Amp rating.
The front panel houses a two-line back-lit LCD display which provides status information in normal use and allows interaction with menu items during programming. Also on the front panel are two screwdriver-accessible rotary enc oders which are used to step through and select from a menu of items which determine the operation of the unit. The push button, when pressed, causes the unit to power up or power down. This button can be disabled if not required. The LED above the button indicates the status of the unit. When the LED is off the unit is fully powered down; when it is on the unit is fully powered up; when it is flashing the unit is in the process of powering up or down.
A built-in AC voltmeter indicates the line voltage on the LCD display. The internal voltmeter is a peak reading type which was chosen because most electronic equipment incorporates a power supply that charges mostly during the AC peaks. Monitoring the peak of the AC provides a more useful indication of the real voltage available to the electronic equipment plugged into the SEQ.
The SEQ is microprocessor controlled and designed to be versatile and expandable. Two or more SEQs can be connected together to provide control and power conditioning for larger systems. The SEQ can also control other SurgeX products with its auxiliary relay contacts and/or its 12V dc output. All options are set via the front panel and all connections are made at the rear panel. An optional password of up to six letters may be specified, preventing unauthorized access to s et­up information. All set-up information is stored in non-volatile memory.
A plug-in Phoenix terminal block on the rear panel accommodates the remote control connections and also the low-voltage outputs. There are three inputs which control sequencing; one programmable 12V dc output; and one programmable auxiliary relay providing normally-open contacts. The inputs can be controlled by an applied DC voltage from 5V to 30V, by a contact closure, or by different types of switch; the input selection being made during programming. The inputs and 12V output are designed to withstand incorrect connections including polarity reversal and shorts.
Software Version 2.0
®
power conditioning and surge protection. The surge protection is rated A-1-1, the highest standard of the
Size
®
Inrush Current Elimination circuitry is incorporated into the SEQ. This eliminates problems associated with
Receptacles
B Receptacles
C Receptacles
®
it is not necessary to take inrush currents into
Receptacles
Receptacles
© SurgeX | Technical Support: 800-645-9721 | surgex.com Page 4
SEQ/SEQ-1U User Manual

2. Features

Unsurpassed SurgeX® Advanced Series Mode® surge elimination
SurgeX
SurgeX
All-time delays and functions easily programmed from the front panel
Bank C can be configured as always on
Accepts both DC voltage and contact closure control inputs
Two or more units can be ganged or cascaded together for larger systems
Programmable auxiliary relay output can be used to control other SurgeX
Programmable 12 Volt DC output can be used to control other SurgeX
Auxiliary relay or 12 Volt DC output can be programmed to provide confirmation feedback
Built-in AC Voltmeter
Separate over-ride input can be used to force unit off or force unit on
Optional password can be used to prevent unauthorized access to set-up information
Adjustable under-voltage and over-voltage shut-down
Optional restore after power failure feature

3. Installation

The SEQ is designed to be installed in a 19 inch equipment rack and requires two units (2RU) of rack space. Use the four thumbscrews (included) to secure the rack ears to the rack rails. These screws can be tightened by hand and do not require tools.
The SEQ-1U is designed to be installed i n a 19 inch equipment rack and requires one unit (1RU) of rack space. Use the eleven flathead screws (included) to secure the left and right rack ears to the product. Use the four thumbscrews (included) to secure the rack ears to the rack rails.
Connect power to the unit by plugging the cord into a 120VAC, 20 Amp wall or floor receptacle. Do not plug the unit into a re-locatable power tap.

3.1 120 Volt Connections

Software Version 2.0
®
Impedance Tolerant® EMI/RFI filtering
®
ICE® Inrush Current Elimination
®
products
®
products or drive LEDs
The SEQ has a total of 14 receptacles: three sequenced banks of four, and two always on. The SEQ-1U has a total of 8 receptacles: three sequenced banks of two, and two always on. Each receptacle is
rated for a maximum load of 15 Amps but the total load must not exceed 20 Amps. Plug the equipment cords into the receptacle banks as needed to turn on equipment in the required sequence. The “always on” receptacles provide power as long as power is supplied to the SEQ. Bank “A” always powers up first and off last.
© SurgeX | Technical Support: 800-645-9721 | surgex.com Page 5
SEQ/SEQ-1U User Manual
Pin 1 – Up Input
Pin 2 – Down Input
Pin 4 – 12 V DC Output
Pin 5 - Common
Pin 6 – Aux Relay Contact
Pin 7 – Aux Relay Contact
Pin 3 – Over-Ride Input
Software Version 2.0

3.2 Remote Control Connections

Remote connections are wired to the green 7-pin plug-in Phoenix termi nal block on the rear of the unit next to the power cord. The terminal block itself is shipped in the accessory bag. After you have made the connections to the terminal block, plug it into the connec tor on the rear of the unit. Never solder (tin) wires before inserting in a terminal block – solder creeps and you will eventually have loose connections!
The connections are shown here:

3.2.1 Up/Down Sequence Control Inputs

The SEQ can be controlled by a DC voltage in the range of 5V to 30V, by a contact closure (such as a relay), or by a switch. In this manual the terms “momentary ” and “latching” are used when describing switches. A momentary switc h is considered to be a switch which provides a connection only while it is actually held pressed, and a latching switch is considered to be a switch which remains in either the on or the off state (like a light switch). Momentary switches are preferred for use with the SEQ since multiple control locations can be used, and also because some of the functions of the SEQ are not available when a latching switch is used (see programming section). Switches with gold contacts are recommended for the best long-term reliability. The type of input is selected totally through programming, making the electrical connections straightforward. The six control options are discussed below: a) DC VOLTAGE: The SEQ will power up when the voltage is present and power down when there is no
voltage. Connect the positive wire to the “Up” input, and the ground (or negative) wire to “Comm on”. Program the input for “5-30 V DC”.
b) CONTACT CLOSURE: The SEQ will power up when the contacts are closed and power down when
the contacts are open. Connect the two wi res from the contacts to “Up” and “Common”. Program the input for “Latching”.
c) MOMENTARY SWITCH(ES): The SEQ will power up when a switch is pressed once and power down
when a switch is pressed a second time. Connect the two wires from the switch(es) to “Up” and “Common”. Program the input for “Momentary”.
d) SEPARATE UP & DOWN SWITCHES: The SEQ will power up when the UP switch is pressed and power
down when the DOWN switch is pressed. Connect the two wires from the UP switch to “Up” and “Common”, and the two wires from the DOWN swi tch to “Down” and “Common”. Program the input for “Separate Up & Down”.
e) CENTER-OFF SWITCH: The SEQ will power up when the switch is pressed to the UP position and
power down when the switch is pressed to the DOWN position. Connect the wire from the UP terminal to “Up”, the wire from the DOWN terminal to “Down”, and the wire from the COMMON terminal to “Common”. Program the input for “Separate Up & Down”.
f) LATCHING SWITCH: The SEQ will power up when the switch is closed and power down when the
switch is open. Connect the two wires from the switch to “Up” and “Common”. Program t he i np ut f or “Latching”.
Note: The front panel button will not operate with options a, b or f
© SurgeX | Technical Support: 800-645-9721 | surgex.com Page 6
SEQ/SEQ-1U User Manual

3.2.2 Over-Ride Input

The SEQ has the option of adding an over-ride func tion for purposes such as providing fire safety over­ride to force the system either on or off. An over-ride is initiated by applying a dc voltage of 5-30V or by a sustained contact closure. The selection of dc voltage or contact closure is accomplished during programming. This topic is covered fully in the programming section.
Connect the over-ride signal to the “over-ride” i nput and “common”. In the case of a dc voltage, connect the positive wire to “over-ride” and the negative wire to “common”.

3.2.3 External LED Connections

The SEQ is able to drive external LEDs or other signaling devices through its 12V DC output which can provide up to 40mA of c urrent. External LEDs connected in this way will mimic the LED on the front panel. When connecting LEDs to the 12V output, a series resistor is required. For example, many LEDs work well with 10mA of current, so a 1K resistor is usually a good choice. If more than one LED is required, then use a separate series resistor for each LED. In this example, four external LEDs could be powered at 10mA each from one SEQ. If more than four LEDs are required, it will be necessary to increase the series resistor so that the total load is not more than 40mA.
Connect each LED anode to “12V DC output” through a resistor, and the cathodes to “Common”. Program the 12V DC Output for “LED”. This causes LEDs connected to the SEQ to flash while the unit is powering up or powering down in the same manner as the front panel LED.

3.2.4 Confirmation Connection

The SEQ offers two ways to provide confirmation feedback to a central controll er: a 12V DC output and isolated relay contacts. Confirmation tells the controller that the SEQ has indeed powered up or that it is fully powered down. If the 12V DC output and the Aux Relay contacts are not used for any other function, you will be free to choose whichever provides the best interface for the application. However, if one of these outputs is used for another function you will have to use the one that is available.
To use the 12V DC output for confirmation, connect “12V DC output” to the positive input of the controller and “Common” to ground. The output will be at 12V when all banks are powered up and will be zero when all banks are powered down. Program 12V DC Output for “Confirm”. Note that the SEQ common terminal is shared between the inputs and the 12V DC output. If you need relay contacts for confirmation and you are using the Aux Relay for another function you can connect a small relay between the 12V DC output and common. The relay coil current must not be more than 40mA, and you must connect a diode such as a 1N4148 or 1N4002 across the relay coil (cathode to +12V dc) to suppress the back-EMF from the coil. If you need assistance with this please contact our technical support department.
To use the Auxiliary Relay contacts for confirmation, connect the contacts to the input of the controller. The relay contacts will be closed when all banks are powered up and open when all banks are powered down. The default for menu item “Aux Output” is “Confirm” so you do not need to program this item unless you previously changed it. The contacts are rated for 30V DC at 1 Amp.
Software Version 2.0
© SurgeX | Technical Support: 800-645-9721 | surgex.com Page 7