SA-82-AR
Hardware Installation
Guide
FIRMWARE VERSION: 1.20.261
SOFTWARE VERSION: 2.00.03
© 2019 AMETEK Electronic Systems Protection | Technical Support: 1-800-645-9721 | UM-SA-82-AR-Rev-D

© 2019 AMETEK Electronic Systems Protection | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________
I. INTRODUCTION 2
II. INST ALLAT ION 3
1. ETHERNET CONNECTION 3
2. AC POWER CONNECTIONS 3
3. LED INDICATORS 3
III. INITIAL SETUP 4
1. DEVICE MANAGEMENT UTILITY (DMU) 4
2. SETTING THE IP ADDRESS 5
IV. OUTLET ON LED INDICATOR 6
V. WEB SERVER 7
1. PASSWORD 7
2. CONTROL AND STATUS PAGE 7
3. SETUP PAGES 8
DEVICE 8
NETWORK 9
ADVANCED NETWORK 10
AUTOPING 11
SCHEDULE 13
PASSWORD 14
VI. COMMAND LINE INTERFACE (CLI) PROTOCOL 15
1. PROMPTS 15
2. CONTOL COMMANDS 15
3. DEVICE COMMANDS 15
4. NETWORK COMMANDS 16
5. AUTOPING COMMANDS 17
6. USER COMMANDS 17
7. EVENT COMMANDS 18
VII. DxP PROTOCOL 19
1. OVERVIEW 19
2. HELLO HANDSHAKE 19
3. DXP PACKET 20
4. COMMANDS 21
5. DESCRIPTERS 21
6. PAYLOADS 23
VIII. FIRMWARE UPGRADES 23
IX. RESET BUTTON 24
X. SPECIFICATIONS 25

© 2019 AMETEK Electronic Systems Protection | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________
I. Introduction
The SurgeX® SA-82-AR is a network attached, IP addressed, web-controlled AC surge protector and power
conditioner. The SA-82-AR may be used to switch up to 8A at 120V. The simple web server structure allows
basic control of two outlets. The extensive programming and setup capabilities are accessed by a web browser,
through a Device Management Utility (DMU), or through a Command Line Interface (CLI).
•
The SA-82-AR features SurgeX® Series Mode
®
surge protection, Impedance
Tolerant EMI/RFI filtering and Over-Voltage Shutdown.
•
Remote reboot any device: monitors, routers, servers, kiosks, etc. The remote device need not be
network attached.
•
Conserve energy by powering down equipment when not in use.
•
Telnet access uses the Command Line Interface (CLI) structure and syntax to completely configure and
control the SA-82-AR. This Axess Ready (AR) device also supports the DxP protocol, which allows
software developers to integrate the unit into custom applications.
•
Up to 2 systems can be continuously monitored with AutoPing,with automatic power control upon loss
of contact. Reboot crashed systems or provide auto power-up, or - down for environmental controls and
notification systems.
•
The SA-82-AR utilizes 2 levels of password security, with only the administrative account having access to
setup and configuration.
Located on the rear panel are the input IEC power plug, network connection (RJ-45), 8A circuit breaker, and output
receptacles.
The front panel contains the Outlet On LED, Self-Test LED, System On LED, and Reset button.

© 2019 AMETEK Electronic Systems Protection | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________
II. Installation
1. Ethernet Connection
The RJ45 connector for 10/100 Ethernet is situated on the rear panel beside
the input power plug. The default IP Address is DHCP assigned. The fallback IP
address is 192.168.1.254.
2. AC Power Connections
Connect the device to be powered On and Off to the output duplex receptacle.
Ensure that the total combined load of all controlled devices does not exceed 8
Amps.
Connect one end of the supplied power cord to the connector labeled “AC Input”,
and the other end to a properly grounded AC outlet.
3.
LED Indicators
The green Self-Test LED indicates that the internal surge protection circuitry is
fully functional. The red Outlet On LED indicates that power is being supplied to
the two receptacles.
The red System On LED indicates that the Axess system is On. This indicator will turn off if the AC voltage rises above
145V, and AC power will be removed from the output receptacles in order to protect connected equipment. When
the AC voltage returns to below 135V, power will automatically be restored to the output receptacles and the System
On LED will turn on.

© 2019 AMETEK Electronic Systems Protection | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________
III. Initial Set-Up
1. Device Management Utility (DMU)
The SurgeX Device Management Utility (DMU) provides the
easiest means to find and configure your AR for use. The DMU
can:
1. Automatically discover multiple ARs on a local
network.
2. Display the current IP address of each AR.
3. Allow the setting of a new IP address for each AR.
4. Perform firmware upgrades.
5. Return an AR to Factory Defaults.
The SurgeX Device Management Utility is available on the
SurgeX website at http://www.surgex.com
Note: The IP address can only be set within the first
2 minutes after powering up the AR. The utility will only work with
ARs on the same local subnet as the PC.
Device
Discover: Automatically discover all ARs on the local
network. The DMU will display the location name
of the AR, the product ID and version number, the
current IP address, and the MAC address. Factory
defaulted ARs will display with the name Axess
Ready and have an IP address that was
automatically assigned by the DHCP server on your
network.
The IP address field also indicates the port
for web access that is currently in use by
the AR. The standard port for web
browser accessibility is factory
default Port 80.
Add: Manually add an AR by IP address.
Clear: Clear the list.

© 2019 AMETEK Electronic Systems Protection | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________
Manage
Open Browser: Opens the web browser interface for the selected AR.
Upgrade Firmware: Starts the Firmware Upgrade dialogue. Firmware
Upgrade requirements: Valid firmware
file. Administrative login
credentials.
“Upgrade Enable” must be set to yes, set via web page or CLI.
Set
IP Address: Changes the IP address of the selected AR.
Factory Defaults: Return the selected AR to a Factory Default state. This action must be
performed within the first 2 minutes after powering up the unit.
Local Address: Select the IP address to Discover on. This may be necessary for computers with
multiple network connections.
Exit
Exits the DMU program.
Help
Online Help: Opens a web browser to online help resources.
About: Displays DMU version information.
2. Setting the IP Address
ARs are configured with a DHCP assigned factory default IP address.
To set the AR’s IP address using one of the following methods, the computer and AR must be on the same local
network.
DMU: Follow the steps in the preceding subsection to set the IP address using the
Device Management Utility (DMU).
CLI: These are the basic commands to set the network parameters. After setting these parameters, the AR
will need to be rebooted for the settings to take effect. Any command that requires rebooting of the AR
will provide a prompt to do so. All commands may be entered as required before rebooting. Manually specifying
the IP address via CLI automatically sets the address as static.

© 2019 AMETEK Electronic Systems Protection | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________
Example: Telnet to IP address of 192.168.1.254 on default Port 23:
SurgeX Axess Ready v1.01.41
User> admin
Password> *****
Axess Ready> set ipaddress 10.1.2.69
Ok
Axess Ready Reboot Required> set subnet 255.255.255.0
Ok
Axess Ready Reboot Required> set gateway 10.1.2.1
Ok
Axess Ready Reboot Required> reboot
The CLI command set ipmode dhcp followed by a reboot command may be used to configure the AR to
automatically acquire its network settings from a DHCP server. A DHCP server will automatically assign
an IP address (dynamic address), as well as the Subnet Mask and Gateway.
To determine what IP address has been automatically assigned by the DHCP server, you will need to
use the Discover feature of the DMU or query your DHCP server and locate the MAC address of the AR in
the DHCP server’s IP/MAC table.
Web: To set the IP address using a web browser, navigate to the current IP address of the AR. Enter the
administrator credentials (Factory Default User: admin, Password: admin), click on “Setup”, then click on
“Network” and follow the directions in the Web Server/Network/Setup section of this manual.
IV. Outlet On LED Indicator
The Outlet On LED functionality is as follows:
The Reset button has been pressed for 5 or more seconds. Releasing the button will
restore the AR to a factory default state.

© 2019 AMETEK Electronic Systems Protection | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________
V. Web Server
The Axess Ready web interface provides the easiest means of operating the outlet and changing
configuration parameters.
To access the web interface, open a web browser and enter the IP address of the AR into the address bar.
1. Password
The AR uses two username/password credential sets, one for normal power control (user)
and one that also provides access to the Setup functions (admin). Default
credentials:
Enter a valid username and password when prompted. When the proper
username/password combination is received, the Control and Status Page is
displayed.
2. Control and Status Page
Once a user is validated, the Control and Status page is displayed.
Note: Only one user may be logged in to the AR at a time.
Press “Power On” or “Power Off” to turn the AC output On or Off. In the event
of a power outage, the AC output will return to its last known
state prior to the outage.
Press “Cycle Power” to temporarily change the state of the
AC output for a specified cycle time (factory default is 10
seconds). The cycle operation performed will either be On-Off-On or Off-OnOff, depending on the initial state of the AC output. During the power cycle operation, the Power Status bar will
indicate the temporary status with a Blue background. Once the cycle is complete, the
status bar will revert to its original condition. To abort a power cycle, press either “Power On”
or “Power Off” and the outlets will assume that status.
Use the Refresh button to update the page with the most current status. Use of the browser’s refresh button
may lead to inadvertent power switching. If an NTP time server is being used, the time of the last refresh will be
displayed in the upper right corner, as well as History log below the Power Status

© 2019 AMETEK Electronic Systems Protection | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________
3. Setup Pages
Setup pages are only available while logged in with Administrator credentials. Press Save to save the new settings.
If the new settings require the AR to be rebooted, a Reboot button will appear at the bottom of the page. Settings
requiring reboot will not take effect until the unit is rebooted.
Device
Location ID: Specifies a name label (up to 20 characters) that will be displayed at the top of all pages.
Assigning unique names is helpful for management of multiple units.
Cycle Time: Specifies the length in seconds of a power cycle (1-999 seconds). This is the amount of time
the outlet will temporarily be On or Off, depending on the initial outlet state.
Disable Off: When checked, removes the Power OFF button from the Status and Control page.
Initial State: Specifies the initial state the AC outlet(s) will assume when the unit is powered up or reset.
Upgrade Enable: Enables the ability to upgrade the firmware of the AR.
Auto Logout: Specifies the inactivity timer duration in minutes (0-99 minutes). If there is no activity after the
specified amount of time, the user will be automatically logged out. Setting the timer duration to 0 disables the
timeout feature.
Enable Security Timeout: When unchecked, disables the 2 minute window for setting IP address and factory
defaults via DMU.
Important: As the AR allows only one web user logged in at any time, use caution when
disabling the timeout feature, as it is possible to lock out other users by forgetting to log
out. Closing the web browser will not log the user out, and may lock out web access. In this
situation it will be necessary to access the AR via telnet and reboot the unit.

© 2019 AMETEK Electronic Systems Protection | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________
Network
IP Mode: Select Static to manually set the IP address using the fields below, or choose
DHCP to allow the AR to automatically acquire its network settings from a DHCP server.
IP Address: Enter a static IP address in dotted decimal format. This field will be automatically set if using
DHCP.
Subnet Mask: Enter the Subnet Mask in dotted decimal format. This field will be automatically set if using
DHCP.
Gateway: Enter the Gateway in dotted decimal format. This field will be automatically set if using DHCP.
DNS: Enter the Domain Name Server address. This will be automatically set if
using DHCP.

© 2019 AMETEK Electronic Systems Protection | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________
Advanced Network
HTTP Port: Specify the port the web server will be accessed on. If the port is changed from the default
value of 80, the AR may be accessed by specifying the new port number in this format:
http://IPADDRESS:NEWPORT. Example: Navigate to http://192.168.1.254:8000 for an IP address of
192.168.1.254 on port 8000.
Linkback URL: This setting allows control of the hotlink displayed on the Goodbye page. It allows use of the
public IP address or DNS name instead of the internal IP address of the AR, which is the default setting. If this
setting is left blank, the hotlink will be the IP address of the unit. Enter up to 128 characters.
Telnet Port: Specify the port to use for telnet access (default 23).
DxP Port: Specify the port to use for DxP protocol (default 9100).
Time Setup: Setup of the time server is required for Scheduling and Logging
functions.
Enable: Enable or disable the use of the time server.
Time Server: Specify the time server. The default is time.nist.gov.
Time Zone: Specify the time zone (-12 to +12) relative to GMT.
DST Enable: Enable or disable the use of Daylight Savings Time.
DST Start/Stop: Specify the start and stop times for DST.

© 2019 AMETEK Electronic Systems Protection | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________
AutoPing
The AutoPing feature allows the AR to automatically detect failed equipment and perform a timed
reboot or other power control function (like turning on an indicator or siren). First specify one or two IP
addresses to be periodically pinged. When the AR no longer receives a response from these addresses, the
programmed power control function is actuated. AND or OR logic can be applied to the two addresses, so
that both (AND) or either (OR) must fail in order to trigger the selected action.
Examples:
Server monitor: AR is installed with the device it
monitors and automatically reboots if there is no
response. Ideal for Kiosks and Servers.
Service monitor: AR is installed with the device to be
rebooted, but pings a remote host to test the
communication channel. Ideal for DSL/Cable Modem
verification.
AR monitors a network device, and powers up an alarm
or redundant system when there is no response. Ideal for
Hot Standby Servers, Environmental Control, Alert for
any network failure.
•
IP Address 1 and 2: Enter the IP
address(es) of the device(s) to be pinged.
•
Frequency 1 and 2: Enter the desired ping frequency in seconds for the device(s) to be pinged (1-
999 seconds).
•
Fail Count 1 and 2: Enter the number of times the ping must consecutively fail
(1-999) before the selected action is triggered.
•
Mode: Select the logic to be used (AND, OR, or Single). With AND logic, both AutoPings must
exceed their fail count to trigger the action. With OR logic, the action will be triggered if either
AutoPing exceeds its fail count. With Single, only AutoPing 1 is used.

© 2019 AMETEK Electronic Systems Protection | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________
•
Action: Select the action to be triggered.
Upon triggering, AR will power on and remain so until
changed via web, telnet, or DxP.
Upon triggering, AR will power on. When the ping
response returns, AR will power off.
Upon triggering, AR will power off and remain so until
changed via web, telnet, or DxP.
Upon triggering, AR will power off. When the ping
response returns, AR will power on.
Upon triggering, AR will cycle the power. AR will then
wait for (Ping Frequency x Fail Count) seconds; if the response does
not return, the power will be cycled again. This will repeatedly
continue until the ping response returns or AutoPing is turned off.
Ensure that the AutoPing frequency is longer than the time
required to reboot the device.
Upon triggering, AR will cycle power one time. It will not cycle again
automatically until the ping response returns and is lost again.
•
Restart: This setting delays the restart of the AutoPing tests after the Action is completed. This
setting allows time for the boot sequence of the failed device to complete.

© 2019 AMETEK Electronic Systems Protection | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________
Schedule
The AR can schedule up to 8 recurring power events. For each event, you may define the starting date
and time, the action to be taken, and the repetition interval (optional).
Important: A Network Time Server (NTS) must be specified and enabled in order to use the time
scheduling feature. A list of public time servers is available at http://www.ntp.org.
•
Date: Set the initial date for the event in mm/dd/yyyy format.
•
Time: Set the initial time for the event in hh:mm format. Hours are specified in
24 hour format; for example, 8:05 pm would be entered as 20:05.
•
Repeat (Optional): Set the repetition interval. 0-999 Days, Hours, or Minutes.
•
Action: Set the action to be scheduled. On, Off, or Cycle.
•
Enable: Enables the event when checked. Uncheck to disable the event.
•
Clear: Deletes a schedule.

© 2019 AMETEK Electronic Systems Protection | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________
Passwords
Two passwords are used by the AR. The User password allows control of the AC output state, but provides
no access to Setup functions. The Administrator password allows full control and setup of the AR.
Passwords may be up to 20 characters long and are case sensitive.
The AR supports three modes of user and password operation.
•
Login Required: Login with password is required for web and telnet access.
•
Auto Login: No login challenge will be required for any mode of operation, until a
Setup function is requested.
•
User Disabled: There is no User account. The Admin username and password will
be required for operation and setup functions across all modes of operation. This is
the factory default mode.
•
Old Password: Enter the password currently in use.
•
New Password: Enter the new password to be used.
•
Confirm Password: Enter the new password to be used again.
Default credentials:

SA-82-AR User Manual
________________________________________________________________________________________________________________________
VI. Command Line Interface (CLI) Protocol
The Command Line Interface provides complete setup of all functions of the AR. The CLI may be accessed through the Telnet protocol, and requires a Telnet
client program. Some commands of the CLI require administrative rights; these are indicated in the following tables.
Notes:
• Telnet negotiations require sending these bytes when first connecting: (0x) FF FD 01 FF FD 03 FF FB 1F FF FB 18 FF FB 20
• Every command must be followed by a Carriage Return and Line Feed: (0x) 0D 0A
1.
Prompts
Prompts the user to enter the user name (either user or admin).
Prompts the user to enter the password.
Prompt displayed while logged in.
Axess Ready Reboot Required>
Prompt displayed after changes have been made that require a reboot. This
prompt will remain active until the AR has been rebooted.
Returns the current status of the outlet.
set outlet < on | off | cycle >
Sets the outlet to the selected state.
set location < 20 character max >
Returns the cycle time currently in use in seconds.
Sets the cycle time in seconds.
Returns the upgrade enable status.
set upgrade enable < yes | no >
Enables or disables the ability to upload new
firmware.
Prompts for admin credentials when logged in as user.
Terminates the telnet session.
© AMETEK Electronic Systems Protection, Inc. | Technical Support: 800-645-9721 | surgex.com 15

© AMETEK Electronic Systems Protection, Inc. | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________________________________________
4. Network Commands
Returns all network settings currently in use. Example: Mode:
DHCP
IP Address: 10.1.2.69
Subnet: 255.255.255.0
Gateway: 10.1.2.1
HTTP Port: 80
Telnet Port: 23
DxP Port: 9100
Timeout: 20
set ipmode < static | dhcp >
Sets the IP address mode. Static mode locks the IP address as
set; DHCP mode allows a DHCP server to assign the address.
set ipaddress < dotted decimal >
set subnet < dotted decimal >
set gateway < dotted decimal >
Sets the Gateway address.
set http port < 0-65535 >
Sets the port that the internal Web server listens for incoming
connections on. When set to 0 the web server is disabled. May not be
disabled when Telnet and DxP are both disabled.
set telnet port < 0-65535 >
Sets the port that the internal Telnet server listens for incoming
connections on. When set to 0 the Telnet server is disabled. May not
be disabled when Web and DxP are both disabled.
Sets the port that the internal DxP service listens for incoming
connections on. When set to 0 the DxP service is disabled. May not
be disabled when Web and Telnet are both disabled.
This command sets the linkback URL displayed on the logout page.
Yes
set timeout < 0-999 >
Sets the automatic network timeout in minutes.

© AMETEK Electronic Systems Protection, Inc. | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________________________________________
5.
AutoPing Commands
Returns all AutoPing settings currently in use. Example: AutoPing 1
AutoPing 2
IP Address: 10.1.2.36 0.0.0.0
Frequency: 60 10
Fail Count: 3 3
Status: OK OK
Trigger Count: 0 0
--------------------------------------
Mode: Single Action:
On-Latch
set autoping < 1 | 2 > address < dotted decimal >
Sets the IP address to be pinged for AutoPing 1 or 2.
set autoping < 1 | 2 > frequency < 1-999 >
Sets the frequency (how often the ping is sent) for
AutoPing 1 or 2 in seconds.
set autoping < 1 | 2 > failcount < 1-999 >
Sets the number of consecutive failures the AutoPings must detect
before the AutoPing considers the pinged device to be failed.
3
set autoping mode < single | and | or >
Sets single AutoPing (AutoPing 1) or two AutoPing relationship
AND or OR.
set autoping action < none | on-latch | on-follow | off-latch |
off-follow | cycle | cycle-once >
Sets the action to be performed when the AutoPing is triggered.
set autoping cycle <0-999>
Sets the maximum number of power cycles when the AutoPing
triggers. 0 = Unlimited
Yes 1 set autoping restart <1-999>
Sets the delay in seconds to restart AutoPing tests after Action.
set password < user | admin > < old > < new > < repeat >
Sets the password of the User or Administrator.
set user account <yes | no>
Sets whether or not a user account is used.
set login required <yes | no>
Sets whether or not a login is required for user level operation. A login
is always required for admin functions.

© AMETEK Electronic Systems Protection, Inc. | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_________________________________________________________________________________________________________________________
7. Event Commands
Returns all scheduled events currently in use. Example:
Date Time Repeats Action
1. 12/22/2011 14:00 every 2 Hour(s) Cycle
2. every 0 Day(s) On
3. every 0 Day(s) On
4. every 0 Day(s) On
5. every 0 Day(s) On
6. every 0 Day(s) On
7. every 0 Day(s) On
8. every 0 Day(s) On
Returns the current time and time server. Example:
Current Time: 10:14:17 12/20/2011
Server: 10.1.2.12
set time server < dotted decimal >
Sets the IP address of a Network Time Server.
set time enable < yes | no >
Enables or disables the use of a time server and scheduled events.
set event <1-8> <run | hold>
Allow the event to run, or put the event on hold.
Run
set event < 1-8 > date < mm/dd/yyyy >
Sets the scheduled event’s starting date.
set event < 1-8 > time < hh:mm:ss >
Sets the time the scheduled event will occur in 24-hour format.
set event < 1-8 > repeat < day | hour |
minute >
Sets the repetition interval type for the selected event.
set event < 1-8 > mult < 0-999 >
Sets the number of repetition intervals for the selected event. For example,
20 days, 30 minutes, 24 hours, etc.
Yes
set event < 1-8 > action < on | off | cycle >
Sets the action to be performed at the scheduled time.
Deletes the scheduled event.

© AMETEK Electronic Systems Protection, Inc. | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
________________________________________________________________________________________________
VII. DxP Protocol
1. Overview
The DxP Protocol is a packet-based protocol designed to be extensible. This protocol is transmitted over TCP
on a user-defined port. The factory default DxP port is 9100.
The protocol uses a Hello handshake to establish unique sequence numbers to allow for advanced security when
AES encryption is used. With AES enabled, all messages must be encrypted with the AES Passphrase set in the
device.
After the Hello, a Command and Response sequence follows. Any number of
Command → Response sequences are permitted after Hello.
2. Hello Handshake
The client sends a Hello message in the form of a text string ‘hello-000’. The DxP enabled device will
respond with a packet containing the unsigned 16 bit sequence number. This sequence number is incremented
by the client and server with each correct packet sent.
Example:

© AMETEK Electronic Systems Protection, Inc. | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
________________________________________________________________________________________________
3. DxP Packet
The packet is broken up into 2 parts: The Header and the Payload.
Header
The header is used to carry general information, such as is shown in the C programming structure below:
typedef struct {
eCmnd command;
char[21] uName;
char[21] password;
uChar desc;
uChar param;
uint16 seq;
} THeader
Enumerated type that tells the DxP server what class of command is being
sent. See the Commands subsection for a full list of command classes.
Reserved for future use. It will contain the user name of a user on the ipIO that
is being accessed.
Reserved for future use. It will contain the password of the user above.
Command descriptor that describes the individual command within a command
class. By extension it lets the server know what the payload is. There is a different set of
descriptors for each command class; see the Descriptors
subsection for a full list of descriptors by command class.
Reserved for future use. Optional parameter that may be passed to the server in addition to the
descriptor.
The packet’s sequence number. Used as part of the security scheme.
Payload
The payload is determined by a combination of the command class and the descriptor. The payloads are
described with the descriptor; see the Descriptors subsection for details.

© AMETEK Electronic Systems Protection, Inc. | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
________________________________________________________________________________________________
4. Commands
There are currently 7 command classes. All classes are defined in the C programming enumerated type
definition below:
typedef enum { eCmnd_null,
eCmnd_set,
eCmnd_get,
eCmnd_io,
eCmnd_keepAlive,
eCmnd_rss,
eCmnd_rcu
} eCmnd;
This is a null command and should not be sent to the server.
This command is used to set programmable variables on the server.
This command is used to get programmable variables from the server.
3
This command is used to monitor and control the I/O on the server.
This command is sent to the server as a means of allowing the client to
validate the communications path to the server.
This command class is used to control the RSS nest using the
RCU.
Note: Project specific command. Not for general use.
This command class is used to update the display of the RCU.
Note: Project specific command. Not for general use.
5. Descriptors
Descriptors are used to describe the individual command within a command class, and the payload that the
packet contains. All of the descriptors and their payloads are outlined by command class below.
eCmnd_set
The descriptors for this command class will be product specific.
eCmnd_get
The descriptors for this command class will be product specific.

© AMETEK Electronic Systems Protection, Inc. | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
________________________________________________________________________________________________
eCmnd_io
typedef enum{ eIO_null,
eIO_changeRelay,
eIO_changeRelays,
eIO_getRelay,
eIO_getRelays,
eIO_getInput,
eIO_getInputs,
eIO_pulseRelay,
} eIO;
This command is used to change the status of an individual relay.
It carries the TChangeRelay payload; see the Payloads
subsection for details.
This command is used to set all of the relays in a device. It carries the
TChangeRelays payload; see the Payloads subsection for details.
This command has not yet been implemented.
This command is used to get the status of all the relays on the
server.
Byte Array
containing status of
each relay.
This command has not yet been implemented.
This command is used to get the status of all inputs on the server.
Byte Array
containing status of
each input.
This command is used to pulse a relay. It carries the
TPulseRelay payload; see the Payloads subsection for details.
eCmnd_keepAlive
typedef enum{
eKeepAlive_null;
} eKeepAlive;
This is the only valid descriptor that the keep alive command
supports. It is defined as null, as it carries no payload.

© AMETEK Electronic Systems Protection, Inc. | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
________________________________________________________________________________________________
6. Payloads
TChangeRelay
typedef struct{
unsigned char relay;
unsigned char state;
} TChangeRelay;
Where relay is the number of the relay to be affected – 1 (For example, 0 for relay 1 and
1 for relay 2) and state sets the state of the relay (1=Energize; 2=Relax).
TChangeRelays
typedef struct{
unsigned char relayStates[32];
}TChangeRelays;
Where relayStates is an array of relay states as defined below:
#define NO_CHANGE 0
#define ENERGIZE 1
#define RELAX 2
This payload is supported by devices that support the DxP protocol with 2-32 controllable
relays.
TPulseRelay
typedef struct{
unsigned char relay; //the relay to be pulsed unsigned
char state; //the state to pulse
uint16 pulseWidth; //the pulse width in seconds
}TPulseRelay;
Where relay is the number of the relay to be affected, state is the state to pulse, and pulseWidth is the
time to pulse in seconds.
VIII. Firmware Upgrades
The AR can be upgraded via the network if the upgrade feature has been enabled. To perform a field upgrade, follow the
steps below.
Important: Upgrading the firmware with a minor upgrade (For example, 1.01.xx to 1.01.yy) will not alter the user
defined settings. Major upgrades may or may not reset the AR to factory defaults. Check the release notes for the
upgrade before making any changes.

© AMETEK Electronic Systems Protection, Inc. | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
________________________________________________________________________________________________
1. Download the latest firmware version and Device Management Utility (DMU) from the
SurgeX website: http://www.surgex.com.
2. Enable the upgrade feature. Use the CLI set upgrade enable yes command via telnet, or check the
“Upgrade Enable” box on the Device web page.
3. Run the DMU. If the AR you would like to upgrade is not visible in the list box, either:
•
Select Device | Discover from the menu to locate the ARs on the local network.
•
Select Device | Add from the menu to manually add the AR by IP address.
Once the device is displayed in the list, highlight it.
4. Select Manage | Upgrade Firmware.
Enter User Name admin and the password for the Administrator.
Enter the filename of the new firmware, or click Browse and navigate to the firmware file to be used. AR
firmware files use the file extension .g2u. If no files of that type are displayed, ensure that the “Files of Type”
box is set for SX-iPD or All Files.
Click OK when all details are entered.
5. The upload will begin, and a progress bar will be displayed.
6. When the firmware upload is complete, the AR will automatically reboot and will be ready for use.
IX. Reset Button
The recessed reset pushbutton located on the front panel performs 3 functions as
detailed below:
Soft Reset. Will not affect outlet state.
Reset to Factory Defaults. Hold until the “System On” LED is blinking,
then release.
Recovery Mode. Allows upload of new firmware to the current IP address.

© AMETEK Electronic Systems Protection, Inc. | Technical Support: 800-645-9721 | surgex.com
SA-82-AR User Manual
_____________________________________________________________________________________________
5% to 95% R.H., non-condensing
Power Requirement (no load)
UL 1449-2 Adjunct Classification
Test Results
1000 surges, 6000 Volts, 3000 Amps,C1 pulse, measured
suppressed voltage 290 Volts, no failures
Maximum Applied Surge Pulse
Joule Rating
Unlimited, due to current limiting (8 x 20 µs)
Maximum Applied Surge Pulse
Voltage
6000 volts (1.2 x 50 µs pulse),industry standard rating
Maximum Applied Surge Pulse
Current
Unlimited, due to current limiting (8 x 20 µs)*
Endurance
IEEE C62.41-1991 Category B3 (C1)
1 kV>500,000; 3 kV>10,000; 6 kV>1000
145 Volts (resume at 135 Volts)
30 dB@100 kHz; 56 dB@300 kHz;64 dB@3 MHz;
24 dB@30 MHz
9 dB@300 kHz; 16 dB@1 MHz;28 dB@5 MHz;
35 dB@20 MHz
UL60950 Listed I.T.E. File
No. E225914
Conforms to UL Stds 1283 & 1449
Certified to CSA Std C22.2 No. 8
Directives 89/336/EEC, 92/31/EEC and 93/68/EEC EN 60950:
3
rd
Edition
EN55022: 1998 Class B
Single 10/100 Unshielded Twisted Pair Ethernet Jack
IP Addressed: DHCP Assigned or Static
Forms Processing Browser Required
*1.2 x 50 µs pulse, industry standard combination wave surge,as per IEEE C62.41