Connections
1. Connect Network. The SA-82-AR/XF2-AR supports 10/ 100
Ethernet using the cable supplied, or other suitable
unshielded twisted pair (Cat 5) cabling.
2. Connect Powered Equipment. Connect the device to be
powered On and Off to the duplex receptacle located on the
rear panel. If the connected equipment has a Power switch,
leave it in the On position to allow the SA-82-AR/XF2-AR to
control the power.
IMPORTANT:
controlled devices does not exceed 8 Amps.
3. Connect Power Mains. Connect one end of the supplied
power cord t o the IEC connect or labeled “AC Input”, and the
other end t o a properly grounded AC outl et.
Web Browser Access
Factory Default IP Address: 192.16 8.1.254
Factory Default Security Credent ials:
Ensure that the total combined load of all
To access the SA-82-AR/XF2-AR from the default IP Address,
the PC must be on the same local network (IP address of
192.168.1.nnn). If it is not, change the IP address using one of the methods on the following
page.
After pointing a web browser to the IP address of the SA-82-AR/XF2-AR, enter the
Administrator Username and Password to access the complete Setup features. Entering the
User credentials will enable access to only the power control. Once the user is validated, the
Control and S tatus page is displayed.
Click on the appropriate button to control the power. During power cycling, the Power Status bar
will indicate the temporary status, and will have a blue background. Once the cycle is complete,
the status bar will rever t to its original condition.
SA-82-AR / XF2-AR Quick Start Guide Page 1
![](/html/c3/c31f/c31fefbd7e744810e2fe693e5db54c4b8bb0f40ad7204e483e84dc8167fcd4ff/bg2.png)
Changing the IP Address
1. Device Management Utility (DMU). Obtain the
latest DMU from the SurgeX website at
http://www.surgex.com. The DMU provides the
easiest means to find and configure your SA-82AR/XF2-AR for use. It can discover all SA-82AR/XF2-ARs on the local network, display the
current IP address of each, and allow the setting of
any valid IP address.
The DMU can also be used to return an SA-82AR/XF2-AR to its factory default condition. This may
be used to recover an SA-82-AR/XF2-AR with a lost password. Highlight a unit in the list
and choose menu item Set | Factory Defa ults.
Note: Setting the IP address or performing a reset to
Factory Defaults can only be performed within the
first 2 minutes of powering up the SA-82-AR/XF2AR. The DMU will only work with units on the same
local subnet as the PC.
2. Web Page Setup - Manual. From the home page,
click Setup, and then Network. Enter the new IP
Address, Subnet Mask, and Gateway, and then click
Save. Click the Reboot button (or press the reset
button nex t to the System On LED) to restart the SA-82-AR/XF2-AR with the new settings.
3. Web Page Setup - DHCP. From the home page, click Setup, and t hen Network. C hange the
IP mode from Static to DHCP. Click Save, and then Reboot. The SA-82-AR/XF2-AR will
automatically obtain its network settings from the DHCP server. Check the server IP/MAC
table or use the DMU to obtain the new sett ings.