PF-420
© 2018 AMETEK Electronic Systems Protection. All rights reserved.
REVISIONS
REV
DAT E
DESCRIPTION
BY
RE V.
TECHNICAL DESCRIPTION
The Powerframe 420 shall be housed in a magnetic shielding NEMA
steel enclosure. It shall operate from 120 volts AC and have a barrier
strip accessible through knock-outs in the enclosure for hardwiring
power input and output connections. Overall dimensions shall be
16.0" H x 12.0" W x 4.0" D. Weight shall be 30 pounds. The
Powerframe 420 shall have a load rating of 20 amps per circuit at 120
volts (80 amps total), a self-test circuit with visual indicator, and
provide EMI/RFI filtering. It shall withstand at least 1000 occurrences
of surge pulse voltages up to 6000 volts.
SPECIFICATIONS
Load Rating
Voltage Rating
Power Requirement (no load)
Surge Let-through Voltage (6000 Volt Surge)
Maximum Applied Surge Voltage
Maximum Applied Surge Current
Maximum Applied Surge Energy
Endurance (C62.41-1991 category B3 pulses)
1RUPDOPRGHORDG
EMI/RFI Filter
&RPPRQ0RGHORDG
Under-Voltage Auto Shutdown
Over-Voltage Auto Shutdown
Over-Current Auto Shutdown
Over-Temperature Auto Shutdown
Voltage NA
Measurement
Accuracy
Network Port
Serial Port
Temperature Sensor Input
Auxiliary Relay Outputs
Contact Closure Input
Dimensions
Weight
Temperature Range:
Humidity Range
Agency Listings
* 1.2 x 50 microsecond industry standard combination wave surge as per IEEE C62.41
** Specifications subject to change without notice
SPECS v.030118
Current NA
Power NA
Energy NA
Temperature NA
20A (x4)
120V
4 W
0 Volts
6000 Volts *
Unlimited (due to current limiting) *
Unlimited (due to current limiting) *
1 KV > 500,000; 3 KV > 10,000; 6 KV > 1000
> 20 dB, 39 kHz – 50 MHz
> 30 dB, 150 kHz – 50 MHz
25 dB @ 100 kHz; 45 dB @ 300 kHz;
67 dB @ 3 MHz; 35 dB @ 30 MHz
> 10 dB, 290 kHz – 50 MHz
> 20 dB, 1.9 MHz - 7.875 MHz
> 30 dB, 4.2 MHz – 5.125 MHz
10 dB @ 300 kHz; 17 dB @ 1 MHz;
30 dB @ 5 MHz; 14 dB @ 20 MHz
No
No
None
None
No
None
None
No
No
16.0" H x 12.0" W x 4.0" D
30 lbs
5C to 35C
5% to 95% R.H. Non-condensing
Conforms to UL Std 1283
Certified to CSA Std C22.2 No. 8
PF420
SX-1115-RT
A
A
KO DIAMETER QTY
A 1.375 8
A
Advanced Series Mode® Surge Eliminator / Power Conditioner
PF-420
A
12.00
BRANCH CIRCUIT
DOOR12.30
KNOCKOUT DIAMETER
A
SELF-TEST
SELF-TEST
SELF-TEST
SELF-TEST
SEE TABLE
Ø,280 X4 HOLES
WALL MOUNT
A
13.00
A
16.30
DOOR
16.00
1.50
4.18
A
11.00
.50
SCALE: .300/1.000
THIS DRAWING IS FOR REFERENCE
J.J. 10/4/06
v1.0
surgex.com