SUPER MICRO Computer 6015B-NTR, 6015B-NT, 6015B-U, 6015b-RU User Manual

®
SUPER
SUPERSERVER 6015B-UR S S SUPERSERVER 6015B-NT
UPERSERVER 6015B-U UPERSERVER 6015B-NTR
USER’S MANUAL
1.0c
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0c Release Date: February 21, 2008
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2008 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It pro-
vides information for the installation and use of the SuperServer 6015B-UR/6015B-
U/6015B-NTR/6015B-NT. Installation and maintenance should be performed by
experienced technicians only.
The SuperServer 6015B-UR/6015B-U/6015B-NTR/6015B-NT is a high-end server
based on the SC815TQ-R650U/SC815TQ-560U 1U rackmount chassis and the Su-
per X7DBU, a dual processor serverboard that supports Intel
series processors at a Front Side (System) Bus speed of 1333/1066/667 MHz and
up to 32 GB of ECC FBD DDR2-667/533 SDRAM.
®
Xeon® 5300/5100/5000
Preface
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the
server system and describes the main features of the X7DBU serverboard and
the SC815TQ-R650U/SC815TQ-560U chassis, which comprise the SuperServer
6015B-UR/6015B-U/6015B-NTR/6015B-NT.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 6015B-UR/
6015B-U/6015B-NTR/6015B-NT into a rack and check out the server confi guration
prior to powering up the system. If your server was ordered without processor and
memory components, this chapter will refer you to the appropriate sections of the
manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
iii
SUPERSERVER 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 6015B-UR/6015B-U/6015B-NTR/6015B-NT.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X7DBU serverboard, including the
locations and functions of connections, headers and jumpers. Refer to this chapter
when adding or removing processors or main memory and when reconfi guring the
serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC815TQ-R650U/SC815TQ-
560U server chassis. You should follow the procedures given in this chapter when
installing, removing or reconfi guring SATA or peripheral drives and when replacing
system power supply modules and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa-
tion on running the CMOS Setup Utility.
Appendix A: BIOS POST Messages
Appendix B: BIOS POST Codes
Appendix C: Software Installation
Appendix D: System Specifi cations
iv
Notes
Preface
v
SUPERSERVER 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
Table of Contents
Preface
About This Manual ...................................................................................................... iii
Manual Organization ................................................................................................... iii
Chapter 1: Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Serverboard Features ..................................................................................... 1-2
1-3 Server Chassis Features ................................................................................ 1-3
1-4 Contacting Super Micro .................................................................................. 1-6
Chapter 2: Server Installation
2-1 Overview ......................................................................................................... 2-1
2-2 Unpacking the System ................................................................................... 2-1
2-3 Preparing for Setup ........................................................................................ 2-1
Choosing a Setup Location ...................................................................... 2-2
Rack Precautions ..................................................................................... 2-2
Server Precautions ................................................................................... 2-2
Rack Mounting Considerations ................................................................ 2-3
2-4 Installing the System into a Rack ................................................................... 2-4
2-5 Checking the Serverboard Setup ................................................................... 2-8
2-6 Checking the Drive Bay Setup ..................................................................... 2-10
Chapter 3: System Interface
3-1 Overview ......................................................................................................... 3-1
3-2 Control Panel Buttons .................................................................................... 3-1
UID ........................................................................................................... 3-1
Reset ........................................................................................................ 3-1
Power ....................................................................................................... 3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
Universal Information LED ....................................................................... 3-2
NIC2 ......................................................................................................... 3-3
NIC1 ......................................................................................................... 3-3
HDD .......................................................................................................... 3-3
Power ....................................................................................................... 3-3
3-4 SATA Drive Carrier LEDs ............................................................................... 3-3
vi
Table of Contents
Chapter 4: System Safety
4-1 Electrical Safety Precautions .......................................................................... 4-1
4-2 General Safety Precautions ........................................................................... 4-2
4-3 ESD Precautions ............................................................................................ 4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5: Advanced Serverboard Setup
5-1 Handling the Serverboard .............................................................................. 5-1
5-2 Processor and Heatsink Installation ............................................................... 5-2
5-3 Connecting Cables ......................................................................................... 5-5
Connecting Data Cables .......................................................................... 5-5
Connecting Power Cables ....................................................................... 5-5
Connecting the Control Panel .................................................................. 5-5
5-4 I/O Ports ......................................................................................................... 5-6
5-5 Installing Memory ........................................................................................... 5-7
5-6 Adding PCI Cards ........................................................................................... 5-9
5-7 Serverboard Details ...................................................................................... 5-10
X7DBU Layout ....................................................................................... 5-10
X7DBU Quick Reference ....................................................................... 5-11
5-8 Connector Defi nitions ................................................................................... 5-12
ATX Power Connector ........................................................................... 5-12
Auxiliary Power Connector ..................................................................... 5-12
Processor Power Connector .................................................................. 5-12
NMI Button ............................................................................................. 5-12
Power LED ............................................................................................. 5-12
HDD LED ............................................................................................... 5-13
NIC1 LED ............................................................................................... 5-13
NIC2 LED ............................................................................................... 5-13
Universal Information LED ..................................................................... 5-13
Power Fail LED ...................................................................................... 5-14
Reset Button .......................................................................................... 5-14
Power Button .......................................................................................... 5-14
Universal Serial Bus (USB0/1) ............................................................... 5-14
Universal Serial Bus Headers ................................................................ 5-15
Serial Ports ............................................................................................. 5-15
Fan Headers .......................................................................................... 5-15
Chassis Intrusion .................................................................................... 5-16
Power LED/Speaker ............................................................................... 5-16
ATX PS/2 Keyboard and PS/2 Mouse Ports ......................................... 5-16
vii
SUPERSERVER 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
Overheat LED ........................................................................................ 5-16
Wake-On-LAN ........................................................................................ 5-17
Wake-On-Ring ........................................................................................ 5-17
SMB ........................................................................................................ 5-17
SMBUS_PS ............................................................................................ 5-17
JLAN 1/2 (Ethernet Ports) ...................................................................... 5-18
Alarm Reset ........................................................................................... 5-18
SGPIO .................................................................................................... 5-18
5-9 Jumper Settings ............................................................................................ 5-19
Explanation of Jumpers ......................................................................... 5-19
CMOS Clear ........................................................................................... 5-19
VGA Enable/Disable ............................................................................... 5-19
LAN Enable/Disable ............................................................................... 5-20
Watch Dog Enable/Disable .................................................................... 5-20
2
I
C Enable/Disable ................................................................................. 5-20
5-10 Onboard Indicators ....................................................................................... 5-21
LAN1/2 LEDs ......................................................................................... 5-21
LE1 ......................................................................................................... 5-21
LE2 ......................................................................................................... 5-21
5-11 Floppy, IDE and SATA Drive Connections ................................................... 5-22
Floppy Connector ................................................................................... 5-22
IDE Connector ........................................................................................ 5-23
SATA Ports ............................................................................................. 5-23
Chapter 6: Advanced Chassis Setup
6-1 Static-Sensitive Devices ................................................................................. 6-1
6-2 Control Panel .................................................................................................. 6-2
6-3 System Fans ................................................................................................... 6-3
System Fan Failure .................................................................................. 6-3
Replacing System Fans ........................................................................... 6-3
6-4 Drive Bay Installation/Removal ...................................................................... 6-4
6-5 Power Supply ................................................................................................. 6-9
6015B-UR/6015B-NTR: Power Supply Failure ........................................ 6-9
6015B-UR/6015B-NTR: Removing/Replacing the Power Supply ............ 6-9
6015B-U/6015B-NT: Power Supply Failure ............................................ 6-10
6015B-U/6015B-NT: Removing/Replacing the Power Supply ............... 6-10
viii
Table of Contents
Chapter 7: BIOS
7-1 Introduction ..................................................................................................... 7-1
7-2 Running Setup ................................................................................................ 7-2
7-3 Main BIOS Setup ............................................................................................ 7-2
7-4 Advanced Setup ............................................................................................. 7-7
7-5 Security ......................................................................................................... 7-23
7-6 Boot .............................................................................................................. 7-24
7-7 Exit ................................................................................................................ 7-25
Appendices:
Appendix A: BIOS POST Messages
Appendix B: BIOS POST Codes
Appendix C: Software Installation
Appendix D: System Specifi cations
ix
S
UPERSERVER 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
Notes
x
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The SuperServer 6015B-UR/6015B-U/6015B-NTR/6015B-NT is a high-end server
comprised of two main subsystems: the SC815TQ-R650U (6015B-UR/6015B-
NTR)/SC815TQ-560U (6015B-U/6015B-NT) 1U server chassis and the X7DBU dual
processor serverboard. Please refer to our web site for information on operating
systems that have been certifi ed for use with the system (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have been
included with the 6015B-UR/6015B-U/6015B-NTR/6015B-NT, as listed below:
One (1) slim DVD-ROM drive [DVM-PNSC-824(B)]
Four (4) sets of 4-cm counter-rotating fans (FAN-0086L)
One (1) IDE cable (CBL-0139L)
Two (2) passive CPU heatsinks (SNK-P0017)
Riser Cards: (see Section 5-6 for details)
One (1) RSC-R1UU-XR for PCI-X card (pre-installed)
One (1) RSC-R1UU-E8R for PCI-X card (in accessory box)
One (1) CSE-R1UU-UE8 for PCI-E card (6015B-UR/6015B-U only)
One (1) CSE-R1UU-2E8 for two PCI-E cards (6015B-NTR/6015B-NT only)
SATA Accessories
One (1) SATA backplane (BPN-SAS-815TQ)
One (1) SATA iPASS cable (CBL-0188L) (6015B-UR/6015B-U only)
Four (4) SAS drive carriers (MCP-220-00001-01)
One (1) SATA cable (CBL-0190L) (6015B-NTR/6015B-NT only)
One (1) SGPIO cable (CBL-0157) (6015B-NTR/6015B-NT only)
One (1) rackmount kit (CSE-PT51L)
One (1) CD containing drivers and utilities
SuperServer 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
Note: a "V" at the end of a server name indicates the chassis is silver.
1-1
S
UPERSERVER 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
1-2 Serverboard Features
At the heart of the SuperServer 6015B-UR/6015B-U/6015B-NTR/6015B-NT lies
the X7DBU, a dual processor serverboard based on Intel's 5000P chipset. Below
are the main features of the X7DBU (see Figure 1-1 for a block diagram of the
chipset).
Processors
The X7DBU supports single or dual 771-pin Intel Xeon 5300/5100/5000 series pro-
cessors at a FSB speed of 1333/1066/667 MHz. Please refer to the serverboard
description pages on our web site for a complete listing of supported processors.
Memory
The X7DBU has eight 240-pin DIMM sockets that can support up to 32 GB of ECC
FBD (Fully Buffered DIMM) DDR2-667 or DDR2-533 SDRAM. The memory is an
interleaved confi guration, which requires modules of the same size and speed to be
installed in pairs. Please refer to Chapter 5 for memory speed jumper settings.
UIO (6015B-UR/6015B-U)
The X7DBU is a specially-designed serverboard that features Supermicro's UIO
(Universal I/O) technology. UIO serverboards have a PCI-Express x8 connector
that can support any one of several types of UIO card types to add SAS ports,
additional LAN ports, etc. to the serverboard. This allows the user to tailor the
serverboard to their own needs. Note: the 6015B-UR/6015B-U does not come
with a UIO card installed.
Serial ATA
An on-chip (ESB2) SATA controller is integrated into the X7DBU to provide a
six-port, 3 Gb/sec Serial ATA subsystem, which is RAID 0, 1 and 10 supported.
The SATA drives are hot-swappable units. Note: The operating system you use
must have RAID support to enable the hot-swap capability and RAID function of
the Serial ATA drives.
Onboard Controllers/Ports
One fl oppy drive controller and one onboard ATA/100 controller are provided to
support up to two IDE hard drives or ATAPI devices. The color-coded I/O ports
include one COM port, a VGA (monitor) port, two USB 2.0 ports, PS/2 mouse and
keyboard ports and two gigabit Ethernet ports.
1-2
Chapter 1: Introduction
ATI Graphics Controller
The X7DBU features an integrated ATI video controller based on the ES1000 graph-
ics chip. The ES1000 was designed specifi cally for servers, featuring low power
consumption, high reliability and superior longevity.
Other Features
Other onboard features that promote system health include onboard voltage moni-
tors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU
overheat sensors, virus protection and BIOS rescue.
1-3 Server Chassis Features
The 6015B-UR/6015B-NTR is built upon the SC815TQ-R650U chassis while the
6015B-U/6015B-NT is built upon the SC815TQ-560U chassis. The following is a
general outline of the main features of both chassis.
System Power
The SC815TQ-R650U features a redundant 650W power supply consisting of two
power modules. The system does not need to be shut down when replacing or
removing a single power supply module. The SC815TQ-560U features a single
560W power supply module. The system must be shut down when replacing or
removing this power supply module.
SATA Subsystem
The SC815TQ-R650U/SC815TQ-560U chassis was designed to support four hot-
swap SATA hard drives. Note: In the 6015B-NTR/6015B-NT, SATA drives are
connected to the onboard SATA ports.
PCI Expansion Slots
6015B-UR/6015B-U: A riser card on the right side of the chassis can support either
one PCI-X 133 card or one PCI-E x8 card. The left side supports a UIO card and
one PCI-E x8 card.
6015B-NTR/6015B-NT: A riser card on the right side of the chassis can support
either one PCI-X 133 card or one PCI-E x8 card. The left side supports two PCI-E
x8 cards. See section 5-6 for details. (Right and left refer to the side when viewed
from the front of the system. The 6015B-NTR/6015B-NT does not support a UIO
card.)
1-3
S
UPERSERVER 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
Front Control Panel
The chassis' control panel provides you with system monitoring and control. LEDs
indicate system power, HDD activity, network activity (two) and UID/overheat/fan
fail/power fail. A main power button and system reset button is also included.
I/O Backplane
The SC815TQ-R650U/SC815TQ-560U is an extended ATX form factor chassis that
is designed to be used in a 1U rackmount confi guration. Ports on the I/O backplane
include one COM port, a VGA port, two USB 2.0 ports, PS/2 mouse and keyboard
ports and two gigabit Ethernet ports. A UID (Unit Identifi er) button and LED are
also located beside the LAN2 Ethernet port.
Cooling System
The SC815TQ-R650U/SC815TQ-560U chassis has an innovative cooling design
that features four sets of 4-cm counter-rotating fans located in the middle section
of the chassis. There is a "Fan Speed Control Mode" setting in BIOS that allows
chassis fan speed to be determined by system temperature. The power supply
module also includes a cooling fan.
1-4
Chapter 1: Introduction
Figure 1-1. Intel 5000P Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
UIOP
(PWR)
SXB1: PCI-E x16
PCI-E x8 slot
PCI-X slot
ES1000
Gb LAN Por ts (2)
ATI
PCI-E x8
PCI-E x8
PCI-E x8
PCI-X 133
CPU #2
5000 P
ESB2
LPC Bus
CPU #1
ATA100
3 Gb/s
USB 2 .0
FBD C H0
FBD C H1
FBD C H2
FBD C H3
IDE
SATA Por ts (4)
USB Ports (5)
DDR2-667/533 (FBD)
DIMM 1A
DIMM 1B
DIMM 2A
DIMM 2B
DIMM 3A
DIMM 3B
DIMM 4A
DIMM 4B
Kybd/
Mouse
1-5
S I/O
FDD
FWH
COM Ports
S
UPERSERVER 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer, B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd.
Chung-Ho 235, Taipei County
Taiwan, R.O.C.
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3991
Web Site: www.supermicro.com.tw
Technical Support:
Email: support@supermicro.com.tw
Tel: 886-2-8228-1366, ext.132 or 139
1-6
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 6015B-UR/
6015B-U/6015B-NTR/6015B-NT up and running. Following these steps in the order
given should enable you to have the system operational within a minimum amount
of time. This quick setup assumes that your system has come to you with the
processors and memory preinstalled. If your system is not already fully integrated
with a serverboard, processors, system memory etc., please turn to the chapter or
section noted in each step for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the SuperServer 6015B-UR/6015B-U/6015B-NTR/
6015B-NT was shipped in and note if it was damaged in any way. If the server itself
shows damage you should fi le a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the 6015B-UR/6015B-
U/6015B-NTR/6015B-NT. It should be situated in a clean, dust-free area that is well
ventilated. Avoid areas where heat, electrical noise and electromagnetic fi elds are
generated. You will also need it placed near a grounded power outlet. Be sure to
read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 6015B-UR/6015B-U/6015B-NTR/6015B-NT was shipped
in should include two sets of rail assemblies, two rail mounting brackets and the
mounting screws you will need to install the system into the rack. Follow the steps
in the order given to complete the installation process in a minimum amount of time.
Please read this section in its entirety before you begin the installation procedure
outlined in the sections that follow.
2-1
S
UPERSERVER 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
Choosing a Setup Location
- Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches).
- Leave approximately 30 inches of clearance in the back of the rack to allow for
suffi cient airfl ow and ease in servicing.
- This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets and the like).
- This product is not suitable for use with visual display work place devices according
to §2 of the the German Ordinance for Work with Visual Display Units.
!
Warnings and Precautions!
!
Rack Precautions
- Ensure that the leveling jacks on the bottom of the rack are fully extended to the
fl oor with the full weight of the rack resting on them.
- In single rack installation, stabilizers should be attached to the rack.
- In multiple rack installations, the racks should be coupled together.
- Always make sure the rack is stable before extending a component from the
rack.
- You should extend only one component at a time - extending two or more simul-
taneously may cause the rack to become unstable.
Server Precautions
- Review the electrical and general safety precautions in Chapter 4.
- Determine the placement of each component in the rack before you install the
rails.
- Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
- Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power
failure.
-
Allow the hot plug SATA drives and power supply modules to cool before touching
them.
-
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
2-2
Chapter 2: Server Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
2-3
S
UPERSERVER 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the 6015B-UR/6015B-U/6015B-NTR/
6015B-NT into a rack unit with the rack rails provided. If the system has already
been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are
a variety of rack units on the market, which may mean the assembly procedure will
differ slightly. You should also refer to the installation instructions that came with
the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies in the rack mounting kit. Each
assembly consists of two sections: an inner fi xed chassis rail that secures directly
to the server chassis and an outer fi xed rack rail that secures directly to the rack
itself (see Figure 2-1). Two pairs of short brackets to be used on the front side of
the outer rails are also included.
Installing the Inner Rails
Both the left and right side inner rails have been pre-attached to the chassis.
Proceed to the next step. A
Figure 2-1. Identifying the Sections of the Rack Rails
(right side rail shown)
2-4
Chapter 2: Server Installation
Installing the Outer Rails
Begin by measuring the distance from the front rail to the rear rail of the rack. Attach
a short bracket to the front side of the right outer rail and a long bracket to the rear
side of the right outer rail. Adjust both the short and long brackets to the proper
distance so that the rail can fi t snugly into the rack. Secure the short bracket to the
front side of the outer rail with two screws and the long bracket to the rear side of
the outer rail with three screws. Repeat these steps for the left outer rail.
Locking Tabs
Both chassis rails have a locking tab, which serves two functions. The fi rst is to
lock the server into place when installed and pushed fully into the rack, which is
its normal position. Secondly, these tabs also lock the server in place when fully
extended from the rack. This prevents the server from coming completely out of
the rack when you pull it out for servicing.
Figure 2-2. Installing the Rack Rails
2-5
S
UPERSERVER 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack. Do this by lining up the rear of the chas-
sis rails with the front of the rack rails. Slide the chassis rails into the rack rails,
keeping the pressure even on both sides (you may have to depress the locking
tabs when inserting). See Figure 2-3.
When the server has been pushed completely into the rack, you should hear the
locking tabs "click".
Figure 2-3. Installing the Server into a Rack
2-6
Chapter 2: Server Installation
Installing the Server into a Telco Rack
To install the 6015B-UR/6015B-U/6015B-NTR/6015B-NT into a Telco type rack, use
two L-shaped brackets on either side of the chassis (four total). First, determine
how far follow the server will extend out the front of the rack. Larger chassis should
be positioned to balance the weight between front and back. If a bezel is included
on your server, remove it. Then attach the two front brackets to each side of the
chassis, then the two rear brackets positioned with just enough space to accom-
modate the width of the telco rack. Finish by sliding the chassis into the rack and
tightening the brackets to the rack.
Figure 2-4. Installing the Server into a Telco Rack
2-7
S
UPERSERVER 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
2-5 Checking the Serverboard Setup
After you install the 6015B-UR/6015B-U/6015B-NTR/6015B-NT in the rack, you will
need to open the top cover to make sure the serverboard is properly installed and
all the connections have been made.
1. Accessing the inside of the System (see Figure 2-5)
First, grasp the two handles on either side and pull the system straight out until it
locks (you will hear a "click"). Next, depress the two buttons on the top of the chas-
sis to release the top cover (1). Push the cover away from you (toward the rear of
the chassis) until it stops (2). You can then lift the top cover from the chassis to
gain full access to the inside of the server.
To remove the system from the rack completely, depress the locking tabs in the
chassis rails (push the right-side tab down and the left-side tab up) to continue to
pull the system out past the locked position.
2. Check the CPUs (processors)
You may have one or two processors already installed in the serverboard. Each
processor needs its own heatsink. See Chapter 5 for instructions on processor and
heatsink installation.
3. Check the system memory
Your server system may have come with system memory already installed. Make
sure all DIMMs are fully seated in their slots. For details on adding system memory,
refer to Chapter 5.
4. Installing add-on cards
If desired, you can install add-on cards to the system. See Chapter 5 for details
on installing PCI add-on cards.
5. Check all cable connections and airfl ow
Make sure all power and data cables are properly connected and not blocking the
chassis airfl ow. See Chapter 5 for details on cable connections.
2-8
Chapter 2: Server Installation
Figure 2-5. Accessing the Inside of the System
2-9
S
UPERSERVER 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
2-6 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the SATA drives
and SATA backplane have been properly installed and all connections have been
made.
1. Accessing the drive bays
All drives are accessable from the front of the server. For servicing the DVD-
ROM and fl oppy drives, you will need to remove the top chassis cover. The SATA
disk drives can be installed and removed from the front of the chassis without
removing the top chassis cover.
2. DVD-ROM and fl oppy disk drives
A slim DVD-ROM and fl oppy drive should be preinstalled in your server. Refer
to Chapter 6 if you need to reinstall a DVD-ROM and/or fl oppy disk drive to the
system.
3. Check the SATA disk drives
Depending upon your system's confi guration, your system may have one or
more drives already installed. If you need to install SATA drives, please refer to
Chapter 6.
4. Check the airfl ow
Airfl ow is provided by four sets of 4-cm fans (each set of fans consists of two
fans that are mounted back to back). The system component layout was care-
fully designed to direct suffi cient cooling airfl ow to the components that generate
the most heat. Note that all power and data cables have been routed in such a
way that they do not block the airfl ow generated by the fans.
5. Supplying power to the system
The last thing you must do is to provide input power to the system. Plug the
power cords from the power supply modules into a high-quality power strip that
offers protection from electrical noise and power surges. It is recommended that
you use an uninterruptible power supply (UPS) source.
2-10
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the SATA drive
carriers to keep you constantly informed of the overall status of the system as well
as the activity and health of specifi c components. There are also two buttons on
the chassis control panel and an on/off switch on the power supply. This chapter
explains the meanings of all LED indicators and the appropriate response you
may need to take.
3-2 Control Panel Buttons
There are three push-buttons located on the front of the chassis: a reset button,
a UID button and a power on/off button.
UID:
the front and rear of the chassis for easy system location in large stack confi gura-
tions. The LED will remain on until the button is pushed a second time. Another
UID button on the rear of the chassis serves the same function.
Reset:
Depressing the UID (unit identifi er) button illuminates an LED on both
Use the reset button to reboot the system.
Power: The main power button is used to apply or remove power from the
power supply to the server system. Turning off system power with this button
removes the main power but keeps standby power supplied to the system.
3-1
S
UPERSERVER 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
3-3 Control Panel LEDs
The control panel located on the front of th SC815TQ-R560U/SC815TQ-560U
chassis has fi ve LEDs. These LEDs provide you with critical information related
to different parts of the system. This section explains what each LED indicates
when illuminated and any corrective action you may need to take.
Universal Information LED: When this LED blinks red quickly, it indicates
a fan failure and when blinking red slowly a power failure. This LED will be blue
when used for UID (Unit Identifi er). When on continuously it indicates an overheat
condition, which may be caused by cables obstructing the airfl ow in the system or
the ambient room temperature being too warm. Check the routing of the cables
and make sure all fans are present and operating normally. You should also check
to make sure that the chassis covers are installed. Finally, verify that the heatsinks
are installed properly (see Chapter 5). This LED will remain fl ashing or on as long
as the indicated condition exists. See the table below for descriptions of the LED
states.
Figure 3-1. Universal Information LED States
Universal Information LED States
State Indication
Fast Blinking Red (1x/sec) Fan Fail
Solid Red CPU Overheat
Slow Blinking Red (1x/4 sec) Power Fail
Solid Blue Local UID Button Depressed
Blinking Blue IPMI-Activated UID
Note: deactivating the UID LED must be performed in the same way it was acti-
vated. (If the UID LED was activated via IPMI, you can only turn the LED off via
IPMI and not with the UID button.)
3-2
Chapter 3: System Interface
2
NIC2: Indicates network activity on LAN2 when fl ashing .
1
NIC1: Indicates network activity on LAN1 when fl ashing.
HDD: Indicates IDE channel activity. On the SuperServer 6015B-UR/
6015B-U/6015B-NTR/6015B-NT, this light indicates SATA and/or DVD-ROM drive
activity when fl ashing.
Power: Indicates power is being supplied to the system's power supply
units. This LED should normally be illuminated when the system is operating.
3-4 SATA Drive Carrier LEDs
Each Serial ATA drive carrier has two LEDs.
Green: When illuminated, the green LED on the front of the SATA drive car-
rier indicates drive activity. A connection to the SATA backplane enables this LED
to blink on and off when that particular drive is being accessed.
Red: The red LED indicates two states. When blinking, it indicates the drive
is rebuilding. When solid, it indicates a drive failure. If a SATA drive fails, you
should be notifi ed by your system management software. Please refer to Chapter
6 for instructions on replacing failed SATA drives.
3-3
S
UPERSERVER 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
Notes
3-4
Loading...
+ 96 hidden pages