Super Micro SYS-5017R-MTRF User Manual

SUPER
SUPERSERVER
5017R-MTF
5017R-MTRF
®
USER’S MANUAL
1.0
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and docu­mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environ­ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warn­ing applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other repro­ductive harm.
Manual Revision 1.0 Release Date: Februarty 15, 2012
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2012 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 5017R-MTF/ 5017R-MTRF. Installation and maintenance should be performed by experienced technicians only.
The SuperServer 5017R-MTF/5017R-MTRF is a high-end server based on the SC813MTQ-350CB/SC813MTQ-R400CB 1U rackmount chassis and the Super X9SRi-F single processor serverboard.
Manual Organization
Preface
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the server system and describes the main features of the X9SRi-F serverboard and the SC813MTQ chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 5017R­MTF/5017R-MTRF into a rack and check out the server confi guration prior to powering up the system. If your server was ordered without processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.
iii
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 5017R-MTF/5017R-MTRF.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X9SRi-F serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi guring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC813MTQ server chassis. You should follow the procedures given in this chapter when installing, removing or reconfi guring SATA or peripheral drives and when replacing system power supply modules and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa­tion on running the CMOS Setup Utility.
Appendix A: POST Error Beep Codes
Appendix B: UEFI BIOS Recovery Instructions
Appendix C: System Specifi cations
iv
Notes
Preface
v
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Table of Contents
Chapter 1 Introduction
1-1 Overview .........................................................................................................1-1
1-2 Motherboard Features .....................................................................................1-2
Processors ......................................................................................................1-2
Memory ...........................................................................................................1-2
Serial ATA ........................................................................................................1-2
SCU SATA ......................................................................................................1-2
I/O Ports .......................................................................................................... 1-2
®
Intelligent Power Node Manager (NM) ..................................................1-3
Intel
1-3 Server Chassis Features ................................................................................1-3
System Power ................................................................................................. 1-3
SATA Subsystem .............................................................................................1-3
Control Panel .................................................................................................. 1-3
Cooling System ............................................................................................... 1-3
1-4 Contacting Supermicro ....................................................................................1-5
Chapter 2 Server Installation
2-1 Overview .........................................................................................................2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup .........................................................................................2-1
Choosing a Setup Location ............................................................................. 2-1
Rack Precautions ............................................................................................ 2-2
Server Precautions .......................................................................................... 2-2
Rack Mounting Considerations .......................................................................2-3
Ambient Operating Temperature ................................................................ 2-3
Reduced Airfl ow .........................................................................................2-3
Mechanical Loading ................................................................................... 2-3
Circuit Overloading .....................................................................................2-3
Reliable Ground ......................................................................................... 2-3
2-4 Installing the System into a Rack ................................................................... 2-4
Identifying the Sections of the Rack Rails ...................................................... 2-4
Installing the Rear Inner Rails ........................................................................2-4
Installing the Rack Rails .................................................................................2-5
Installing the Server into the Rack .................................................................. 2-6
Installing the Server into a Telco Rack ........................................................... 2-7
Chapter 3 System Interface
3-1 Overview .........................................................................................................3-1
vi
Table of Contents
3-2 Control Panel Buttons ..................................................................................... 3-1
Reset ...............................................................................................................3-1
Power ..............................................................................................................3-1
3-3 Control Panel LEDs ........................................................................................3-2
Overheat/Fan Fail ........................................................................................... 3-2
NIC2 ................................................................................................................3-2
NIC1 ................................................................................................................3-2
HDD .................................................................................................................3-2
Power ..............................................................................................................3-3
3-4 Hard Drive Carrier LEDs ................................................................................. 3-3
Chapter 4 System Safety
4-1 Electrical Safety Precautions .......................................................................... 4-1
4-2 General Safety Precautions ............................................................................4-2
4-3 ESD Precautions ............................................................................................. 4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5 Advanced Motherboard Setup
5-1 Handling the Motherboard ..............................................................................5-1
Precautions .....................................................................................................5-1
Unpacking .......................................................................................................5-1
5-2 Processor and Heatsink Installation................................................................5-2
Installing an LGA2011 Processor .................................................................... 5-2
Installing a CPU Heatsink ............................................................................... 5-5
5-3 Connecting Cables .......................................................................................... 5-7
Connecting Data Cables ................................................................................. 5-7
Connecting Power Cables ..............................................................................5-7
Connecting the Control Panel ......................................................................... 5-7
5-4 I/O Ports ..........................................................................................................5-8
5-5 Installing Memory ............................................................................................ 5-9
Memory Population Guidelines .....................................................................5-10
5-6 Adding PCI Cards ......................................................................................... 5-12
5-7 Motherboard Details ...................................................................................... 5-13
X9SRi-F Quick Reference ............................................................................. 5-13
5-8 Connector Defi nitions ................................................................................... 5-15
5-9 Jumper Settings ............................................................................................5-22
5-10 Onboard Indicators ........................................................................................5-24
5-11 SATA Ports ....................................................................................................5-25
5-12 Installing Drivers ............................................................................................5-26
SuperDoctor III .............................................................................................. 5-27
vii
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices ..................................................................................6-1
Precautions .....................................................................................................6-1
Unpacking .......................................................................................................6-1
6-2 Control Panel ..................................................................................................6-2
6-3 Accessing the Inside of the System................................................................6-3
6-4 System Fans ...................................................................................................6-4
6-5 Drive Bay Installation/Removal .......................................................................6-4
Removing the Front Bezel .............................................................................. 6-4
Accessing the Drive Bays ...............................................................................6-5
Hard Drive Installation ..................................................................................... 6-5
SATA Backplane ..............................................................................................6-6
6-6 Power Supply .................................................................................................. 6-8
5017R-MTF Power .......................................................................................... 6-8
Power Supply Failure ......................................................................................6-8
5017R-MTRF Power ....................................................................................... 6-9
Chapter 7 BIOS
7-1 Introduction ......................................................................................................7-1
Starting BIOS Setup Utility .............................................................................. 7-1
How To Change the Confi guration Data .........................................................7-1
How to Start the Setup Utility .........................................................................7-2
7-2 Main Setup ...................................................................................................... 7-2
7-3 Advanced Setup Confi gurations......................................................................7-4
7-4 Event Logs .................................................................................................... 7-19
7-5 IPMI ...............................................................................................................7-20
7-6 ISCSI .............................................................................................................7-22
7-7 Boot Settings ................................................................................................ 7-23
7-8 Security Settings ...........................................................................................7-24
7-9 Exit Options ................................................................................................... 7-25
7-10 Main Confi guration Page .............................................................................. 7-26
Appendix A POST Error Beep Codes Appendix B UEFI BIOS Recovery Instructions Appendix C System Specifi cations
viii
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The SuperServer 5017R-MTF/5017R-MTRF is a high-end server comprised of two main subsystems: the SC813MTQ-350CB/SC813MTQ-R400CB 1U server chassis and the X9SRi-F single processor motherboard. Please refer to our web site for information on operating systems that have been certifi ed for use with the system (www.supermicro.com).
In addition to the motherboard and chassis, various hardware components have been included with the 5017R-MTF/5017R-MTRF, as listed below:
Four sets of 4-cm counter-rotating fans (FAN-0065L4)
One passive CPU heatsink (SNK-P0047P)
One air shroud for 1U system (MCP-310-19007-0N
One riser card for one PCI-E 3.0 x16 add-on card (RSC-RR1U-E16)
SATA Accessories
One SATA backplane (BPN-SAS-815TQ) Four 3.5" hard drive carriers (MCP-220-00075-0B) One SATA cable (CBL-0186L)
One rackmount kit (MCP-290-00050-0N)
One CD containing drivers and utilities
SuperServer 5017R-MTF/5017R-MTRF User's Manual
1-1
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
1-2 Motherboard Features
At the heart of the SuperServer 5017R-MTF/5017R-MTRF lies the X9SRi-F, a single processor motherboard based on Intel's C600 chipset. Below are the main features of the X9SRi-F (see Figure 1-1 for a block diagram of the chipset).
Processors
The X9SRi-F supports a single Intel® Xeon® E5-2600/E5-1600 Series processor in an LGA 2011 socket. Please refer to the motherboard description pages on our web site for a complete listing of supported processors.
Memory
The X9SRi-F has eight DIMM sockets that can support up to 256 GB of DDR3­1600/1333/1066 ECC R/LRDIMMs (LRDIMM = Reduced Load DIMMs) or up to 64GB of ECC UDIMMs. Please refer to Chapter 5 for installing memory.
Serial ATA
An on-chip SATA controller is integrated into the X9SRi-F to provide two 6 Gb/sec SATA3 ports and four 3 Gb/sec SATA2 ports, which are RAID 0, 1, 5 and 10 sup­ported (RAID 5 supported with Windows OS only).
Note: The operating system you use must have RAID support to enable the hot­swap capability and RAID function of the SATA drives. Documentation on RAID setup guid eline s can be f ound on ou r web site.
SCU SATA
An additional SCU SATA controller integrated into the chipset provides four SATA 2 ports. RAID 0, 1 and 10 are supported. The SATA drives are hot-swappable units.
Note: You must have RAID set up to enable the hot-swap capability of the SATA drives. Documentation on RAID setup guidelines can be found on our web site.
I/O Ports
The color-coded I/O ports include one COM port, a VGA (monitor) port, two USB 2.0 ports, PS/2 mouse and keyboard ports and two gigabit Ethernet ports. A dedicated IPMI LAN port is also included.
1-2
Chapter 1: Introduction
Intel® Intelligent Power Node Manager (NM)
The Intel® Intelligent Power Node Manager (IPNM) provides your system with real-time thermal control and power management for maximum energy effi ciency . Although IPNM Specifi cation Version 1.5 is supported by the BMC (Baseboard Management Controller), your system must also have IPNM-compatible Manage­ability Engine (ME) fi rmware installed to use this feature.
1-3 Server Chassis Features
The following is a general outline of the main features of the SC813MTQ chassis.
System Power
When confi gured as a SuperServer 5017R-MTF, the SC813MTQ chassis includes a single 350W power supply. When confi gured as a SuperServer 5017R-MTRF, the SC813MTQ chassis includes a redundant 400W power supply.
SATA Subsystem
For the 5017R-MTF/5017R-MTRF, the SC813MTQ chas sis was de signed to s up­por t four SATA hard drives, wh ich are h ot-sw appabl e units .
Note: The operating system you use must have RAID support to enable the hot-swap capability of the SATA drives (system-based RAID is not available for SATA).
Control Panel
The SC813MTQ's control panel provides important system monitoring and control information. LEDs indicate power on, network activity, hard disk drive activity and system overheat conditions. The control panel also includes a main power button and a system reset button. The front of the SC813MTQ also includes a COM port and two USB serial ports for easy access.
Cooling System
The SC813MTQ chassis has an innovative cooling design that features four 4-cm high-performance system cooling fans. Each of these fans plug into a chassis fan header on the motherboard.
A fan speed control setting in BIOS allows fan speed to be determined by system temperature.
1-3
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Figure 1-1. Intel C600 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
SLOT 6
SLOT 4
SLOT 5
SLOT 1/2/3
PCI-E X16 G3
PCI-E X16
PCI-E X8 G3
PCI-E X8
PCI-E X4 G2
PCI-E X8
PCI-X
PCI-X
#0-8
#0-7
#0-6
#0-5
DDRIII
800/1066/1333
RJ45
RJ45
PXH
#7
#6
#5
LAN#1/2
i350/x540
#4
#3
#2
#1
#0
SAS
VR12
6 PHASE
Sandybridge-EP
8 SNB CORE DDR-III
#2 #3C/D #1B #1A
#3A/B
PCI-E X8 G3
#1/2/3/4
PCH PATSBURG SSB-D
PCI-E X4
#5/6/7/8
6.0 Gb/S
SPI
BIOS
COM1 Rear
DMI2
PCI-E X4 G3
DMI2 4GB/s
SIO
NCT6776F
PS/2 KB/MS
LPC
COM2 Header
3.0 Gb/S
6.0 Gb/S
USB 2.0
PCI
TPM
HEADER
#4
#3
#2
#1
#0
#0-2
#0-1
DDRIII
800/1066/1333
#5
SATA
SATA
VGA PHY
#0-4
#0-3
BMC
WPCM450
RJ45
#12 #13
RMII
DDR2
2 Rear
#5
#4
#2
#1
#0
USB
6 Front 1 Type-A
#9
#8
#7
#6
1-4
Chapter 1: Introduction
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave. San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support) rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd. Chung-Ho 235, Taipei County Taiwan, R.O.C.
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3991
Web Site: www.supermicro.com.tw
Technical Support:
Email: support@supermicro.com.tw
Tel: 886-2-8226-5990
1-5
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Notes
1-6
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 5017R­MTF/5017R-MTRF up and running. Following the steps in the order given should enable you to have the system operational within a minimal amount of time. This quick setup assumes that your 5017R-MTF/5017R-MTRF system has come to you with the processor and memory preinstalled. If your system is not already fully integrated with a motherboard, processor, system memory etc., please turn to the chapter or section noted in each step for details on installing specifi c components.
2-2 Unpacking the System
Y ou should inspect the box the SuperServer 5017R-MTF/5017R-MTRF was shipped in and note if it was damaged in any way. If the server itself shows damage, you should fi le a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 5017R­MTF/5017R-MTRF. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fi elds are generated. You will also need it placed near a grounded power outlet. Read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 5017R-MTF/5017R-MTRF was shipped in should include two sets of rail assemblies, six rail mounting brackets and the mounting screws you will need to install the system into the rack. Follow the steps in the order given to complete the installation process in a minimal amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow.
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for suffi cient airfl ow and ease in servicing.This product is for
2-1
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
!
!
installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like).
This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
Warnings and Precautions!
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to
the fl oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the
rack.
You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
Determine the placement of each component in the rack before you install the
rails.
Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power failure.
Allow the hot plug SATA drives and power supply modules to cool before touch-
ing them.
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
2-2
Chapter 2: Server Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera­ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera­ture (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connec­tions other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).
2-3
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the SuperServer 5017R-MTF/5017R­MTRF into a rack unit with the rack rails provided.
There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
Y ou may have received rack rail hardware with the SuperServer 5017R-MTF/5017R­MTRF. (Two front inner rails should already be attached to the chassis.) This hardware consists of two rear inner rails that secure to the chassis, one on each side just behind the preinstalled front inner rails. Note that these two rails are left/ right specifi c.
Installing the Rear Inner Rails
First, locate the right rear inner rail (the rail that will be used on the right side of the chassis when you face the front of the chassis). Align the two square holes on the rail against the hooks on the right side of the chassis. Securely attach the rail to the chassis with M4 fl at head screws. Repeat these steps to install the left rear inner rail to the left side of the chassis (see Figure 2-1). You will also need to attach the rail brackets when installing into a telco rack.
Locking Tabs: Both chassis rails have a locking tab, which serves two functions. The fi rst is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.
2-4
Chapter 2: Server Installation
Figure 2-1. Installing Rear Inner Chassis Rails
Installing the Rack Rails
Determine where you want to place the SuperServer 5017R-MTF/5017R-MTRF in the rack (see Rack and Server Precautions in Section 2-3). Position the chassis rail guides at the desired location in the rack, keeping the sliding rail guide facing the inside of the rack. Screw the assembly securely to the rack using the brackets provided. Attach the other assembly to the other side of the rack, making sure that both are at the exact same height and with the rail guides facing inward.
2-5
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). See Figure 2-2.
When the server has been pushed completely into the rack, you should hear the locking tabs "click".
Figure 2-2. Installing the Server into a Rack
(with optional front bezel shown)
2-6
Chapter 2: Server Installation
Installing the Server into a Telco Rack
To install the SuperServer 5017R-MTF/5017R-MTRF into a Telco type rack, use two L-shaped brackets on either side of the chassis (four total). First, determine how far the server will extend out the front of the rack. Larger chassis should be positioned to balance the weight between front and back. If a bezel is included on your server, remove it. Then attach the two front brackets to each side of the chas­sis, then the two rear brackets positioned with just enough space to accommodate the width of the rack. Finish by sliding the chassis into the rack and tightening the brackets to the rack.
Figure 2-3. Installing the Server into a Telco Rack
(with optional front bezel shown)
2-7
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Notes
2-8
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the hard drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi c components. There are also two buttons on the chassis control panel and an on/off switch on the power supply. This chapter explains the meanings of all LED indicators and the appropriate response you may need to take.
3-2 Control Panel Buttons
There are two push-buttons located on the front of the chassis: a reset button and a power on/off button.
Reset
The reset button reboots the system.
Power
This is the main power button, which is used to apply or turn off the main system power. T urning off system power with this button removes the main power but keeps standby power supplied to the system.
3-1
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
3-3 Control Panel LEDs
The control panel located on the front of the SC813MTQ chassis has fi ve LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
Overheat/Fan Fail
When this LED fl ashes, it indicates a fan failure. When on continuously it indicates an overheat condition, which may be caused by cables obstructing the airfl ow in the system or the ambient room temperature being too warm. Check the routing of the cables and make sure all fans are present and operating normally. You should also check to make sure that the chassis covers are installed. Finally, verify that the heatsinks are installed properly (see Chapter 5). This LED will remain fl ashing or on as long as the indicated condition exists.
2
NIC2
Indicates network activity on LAN2 when fl ashing.
1
NIC1
Indicates network activity on LAN1 when fl ashing.
HDD
Channel activity for all HDDs. This light indicates hard drive activity on the 5017R­MTF/5017R-MTRF when fl ashing.
3-2
Chapter 3: System Interface
Power
Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating.
3-4 Hard Drive Carrier LEDs
Each drive carrier has two LEDs.
Green: When ill uminated, the green LED on the dri ve carrier i ndicates dri ve
activ ity. A connecti on to the backp lane enables t his LED to blink on an d off when that particular drive is being accessed.
Red: The red LED to indicate a drive failure. If one of the drives fails, you should
be notifi ed by your system management software. Please refer to Chapter 6 for instructions on replacing failed drives.
3-3
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Notes
3-4
Chapter 4: System Safety
!
Chapter 4
System Safety
4-1 Electrical Safety Precautions
Basic electrical safety precautions should be followed to protect yourself from harm and the SuperServer 5017R-MTF/5017R-MTRF from damage:
Be aware of the locations of the power on/off switch on the chassis as well
as the room's emergency power-off switch, disconnection switch or electrical outlet. If an electrical accident occurs, you can then quickly remove power from the system.
Do not work alone when working with high voltage components.
Power should always be disconnected from the system when removing or in-
stalling main system components, such as the serverboard, memory modules and fl oppy drive. When disconnecting power, you should fi rst power down the system with the operating system fi rst and then unplug the power cords of all the power supply units in the system.
When working around exposed electrical circuits, another person who is familiar
with the power-off controls should be nearby to switch off the power if neces­sary.
Use only one hand when working with powered-on electrical equipment. This
is to avoid making a complete circuit, which will cause electrical shock. Use extreme caution when using metal tools, which can easily damage any electrical components or circuit boards they come into contact with.
Do not use mats designed to decrease static electrical discharge as protection
from electrical shock. Instead, use rubber mats that have been specifi cally designed as electrical insulators.
The power supply power cords must include a grounding plug and must be
plugged into grounded electrical outlets.
4-1
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
!
This product may be connected to an IT power system. In all cases, make sure
that the unit is also reliably connected to Earth (ground).
Serverboard Battery: CAUTION - There is a danger of explosion if the onboard
battery is installed upside down, which will reverse its polarites (see Figure 4-1). This battery must be replaced only with the same or an equivalent type recom­mended by the manufacturer (CR2032). Dispose of used batteries according to the manufacturer's instructions.
DVD-ROM Laser: CAUTION - this server may have come equipped with a
DVD-ROM drive. To prevent direct exposure to the laser beam and hazardous radiation exposure, do not open the enclosure or use the unit in any uncon­ventional way.
Mainboard replaceable soldered-in fuses: Self-resetting PTC (Positive Tempera-
ture Coeffi cient) fuses on the mainboard must be replaced by trained service technicians only. The new fuse must be the same or equivalent as the one replaced. Contact technical support for details and support.
4-2 General Safety Precautions
Follow these rules to ensure general safety:
Keep the area around the 5017R-MTF/5017R-MTRF clean and free of clutter.
The 5017R-MTF/5017R-MTRF weighs approximately 38 lbs (~17.3 kg) when
fully loaded. When lifting the system, two people at either end should lift slowly with their feet spread out to distribute the weight. Always keep your back straight and lift with your legs.
Place the chassis top cover and any system components that have been re-
moved away from the system or on a table so that they won't accidentally be stepped on.
While working on the system, do not wear loose clothing such as neckties and
unbuttoned shirt sleeves, which can come into contact with electrical circuits or be pulled into a cooling fan.
4-2
Chapter 4: System Safety
!
Remove any jewelry or metal objects from your body, which are excellent metal
conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present.
After accessing the inside of the system, close the system back up and secure
it to the rack unit with the retention screws after ensuring that all connections have been made.
4-3 ESD Precautions
Electrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other. An electrical discharge is created to neutralize this difference, which can damage electronic com ponents and printed circuit boards. The following measures are generally suffi cient to neutralize this difference before contact is made to protect your equipment from ESD:
Use a grounded wrist strap designed to prevent static discharge.
Keep all components and printed circuit boards (PCBs) in their antistatic bags
until ready for use.
Touch a grounded metal object before removing the board from the antistatic
bag.
Do not let components or PCBs come into contact with your clothing, which may
retain a charge even if you are wearing a wrist strap.
Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or contacts.
When handling chips or modules, avoid touching their pins.
Put the serverboard and peripherals back into their antistatic bags when not
in use.
For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and the serverboard.
4-3
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
!
!
4-4 Operating Precautions
Care must be taken to assure that the chassis cover is in place when the 5017R­MTF/5017R-MTRF is operating to assure proper cooling. Out of warranty damage to the system can occur if this practice is not strictly followed.
Figure 4-1. Installing the Onboard Battery
LITHIUM BATTERY
BATTERY HOLDER
Please handle used batteries carefully. Do not damage the battery in any way; a damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfi ll. Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly.
4-4
Chapter 5: Advanced Motherboard Setup
Chapter 5
Advanced Motherboard Setup
This ch apter cover s the ste ps requi red to inst all pro ces sors a nd heats inks to the X9SRi-F motherboard, connect the data and power cables and install add-on cards . All m other boa rd jump ers an d con nec tion s are des cri bed an d a layout and quick re ference chart are included in this chapter. Remember to close the chassis completely when you have fi nished wor king on the motherboard to protect and cool the system suffi ciently.
5-1 Handling the Motherboard
Static electrical discharge can damage electronic com ponents. To prevent damage to printed circuit boards, it is important to handle them very carefully (see Chapter 4). Also note that the size and weight of the motherboard can cause it to bend if handled improperly, which may result in damage. To prevent the motherboard from bending, keep one hand under the center of the board to support it when handling.
The following measures are generally suffi cient to protect your equipment from static discharge.
Precautions
Use a grounded wrist strap designed to prevent static discharge.
Touch a grounded metal object before removing any board from its antistatic
bag.
Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or gold contacts.
When handling chips or modules, avoid touching their pins.
Put the motherboard, add-on cards and peripherals back into their antistatic
bags when not in use.
Unpacking
The motherboard is shipped in antistatic packaging to avoid static damage. When unpacking the board, make sure the person handling it is static protected.
5-1
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
OPEN 1st
WARNING!
OPEN 1st
WARNING!
5-2 Processor and Heatsink Installation
Notes:
Always connect the power cord last and always remove it before adding, re-
moving or changing any hardware components. Make sure that you install the processor into the CPU socket before you install the CPU heatsink.
If you buy a CPU separately, make sure that you use an Intel-certifi ed multi-
directional heatsink only.
Make sure to install the motherboard into the chassis before you install the
CPU heatsinks.
When receiving a motherboard without a processor pre-installed, make sure that
the plastic CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately.
Refer to the Sup ermi cro web s ite for upd ates on CPU su ppor t.
Installing an LGA2011 Processor
Press down on
1. There are two levers on the LGA2011 socket. First press and release the load lever labeled 'Open 1st'.
2. Press the second load lever labeled 'Close 1st' to release the load plate from its locked position.
Pull lever away from the socket
the lever labeled
'Close 1st'
WARNING!
OPEN 1st
WARNING!
OPEN 1st
5-2
3. With the lever labeled 'Close 1st'
WARNING!
OPEN 1st
WARNING!
fully retracted, gently push down on the ' Open 1st ' lever to o pen th e load plate. Lift the load plate to open it completely.
4. Using your t humb an d the ind ex nger, remove the ' WAR NIN G' plastic c ap fr om the so cket.
5. Use your thumb and index fi nger to hold the CPU by its edges. Align the CPU keys, which are semi­circle cutouts, against the socket keys.
6. Once they are aligned, carefully lower the CPU straight down into the socket. (Do not drop the CPU on the socket. Do not move the CPU horizontally or vertically and do not rub the CPU against any pins of the socket, which may damage the CPU or the socket.)
Chapter 5: Advanced Motherboard Setup
WARNING!
OPEN 1st
Gently push down to pop the load plate open.
WARNING!
Socket Keys
CPU Keys
5-3
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
!
OPEN 1s
t
OPEN 1st
Warning: You can only install the CPU to the socket in one direction. Make sure that the CPU is properly inserted into the socket before closing the load plate. If it doesn't close properly, do not force it as it may damage your CPU. Instead, open the load plate again and double-check that the CPU is aligned properly.
7. With the CPU in the socket, in­spect the four corners of the CPU to make sure that they are fl ush with the socket.
8. Close the load plate. Lock the lever labeled 'Close 1st', then lock the lever labeled 'Open 1st'. Use your thumb to gently push the load levers down until the lever locks.
Gently close
the load plate.
Push down and lock the
level labeled 'Close 1st'.
Lever Lock
OPEN 1st
OPEN 1st
Push down
and lock the
lever labeled
'Open 1st'.
5-4
Chapter 5: Advanced Motherboard Setup
Installing a CPU Heatsink
1. Do not apply any thermal grease to the heatsink or the CPU die; the required amount has already been applied.
2. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the serverboard and the heatsink bracket underneath.
3. Screw in two diagonal screws (i.e., the #1 and the #2 screws) until just snug. (To avoid possible damage to the CPU do not over-tighten the screws.)
4. Finish the installation by fully tightening all four screws.
Top View
Screw#1
Screw#4
Side View
Screw#1
Screw#3
Screw#2Screw#3
Screw#2
Side View
Bottom View
5-5
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Figure 5-1. Installing the Heatsink
Figure 5-2. Removing the Heatsink
Loosen screws in the sequence shown
Screw #1
Motherboard
Screw #4
Screw #2
Screw #3
5-6
Chapter 5: Advanced Motherboard Setup
5-3 Connecting Cables
Now that the processors are installed, the next step is to connect the cables to the motherboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables.
Connecting Data Cables
The cables used to transfer data from the peripheral devices have been carefully routed in preconfi gured systems to p r eve nt t h e m from blockin g t h e fl ow of cooling air that moves through the system from front to back. If you need to disconnect any of these c a bles, you shou l d take care to rero ute them as they were originally after reconnecti n g them (make sure the red wires connec t t o the pin 1 location s). If you are confi guring the syst em, keep th e air fl ow in mind when routing the cables. The following data cables (with their motherboard connector locations noted) should be connected. See the motherboard layout diagram in this chapter for connector locations.
Control Panel cable (JF1, see next page)
SATA cables (I-SATA0 ~ I-SATA3)
SGPIO cable (T-SGPIO1 to SATA backplane)
Connecting Power Cables
The X9SRi-F has a 24-pin primary power supply connector designated "JPW1" for conne c t i on t o t he ATX powe r sup p ly. Conn ect the app ro p r i ate c o nn e c to r f r om t h e power supp ly to JPW1 to supply p ower to the mother board. See th e Connecto r Defi nitions s ecti on in thi s chapter f or power c onne ctor pi n defi nitions.
In addition, your power supply must be connected to the 8-pin Processor Power connector at JPW2.
Connecting the Control Panel
JF1 contains header pins for various front control panel connectors. See Figure 5-1 for the pin locations of the various front control panel buttons and LED indicators. Please note that even and odd numbered pins are on opposite sides of each header.
All JF1 wires have been bundled into single keyed ribbon cable to simplify their con­nection. Connect one end of this cable to JF1 and the other end to the Control Panel printed circuit board, located just behind the system status LEDs in the chassis.
5-7
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
See the Connector Defi nitions section in this chapter for details and pin descrip- tions of JF1.
Figure 5-1. Front Control Panel Header Pins (JF1)
1920
Ground
NMI
Power LED
HDD LED
NIC1 LED
NIC2 LED
OH/Fan Fail LED
Power Fail LED
Ground
Ground
X
2
1
X
Vcc
Vcc/UID Switch
Vcc
Vcc
Vcc/Blue UID LED
Vcc
#3~4
#1~2
Reset Button
Power Button
5-4 I/O Ports
The I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 below for the colors and locations of the various I/O ports.
Figure 5-2. Rear Panel I/O Ports
1
1
2
1
1
1. Keyboard (Purple) 6. COM1
2. PS/2 Mouse (Green) 7. VGA
3. USB Port 0 8. LAN1
4. USB Port 1 9. LAN2
5. IPMI LAN
5
1
4
1
3
1
6
I/O Ports
1
7
5-8
1
8
1
9
Chapter 5: Advanced Motherboard Setup
5-5 Installing Memory
Note: Check the Supermicro web site for recommended memory modules.
CAUTION
Exercise extreme care when installing or removing DIMM modules
to prevent any po ssibl e damage.
Installing DIMMs
1. Insert the desired number of DIMMs into the memory slots, starting with slot DIMMA1.
2. Push the release tabs outwards on both ends of the DIMM slot to unlock it.
3. Align the key on the DIMM module with the receptive point on the slot.
4. Use two thumbs together to press both ends of the module straight down into the slot until the module snaps into place.
5. Press the release tabs to the lock positions to secure the DIMM module into the slot. See Figure 5-3.
Memory Support
The X9SRi-F supports up to 256 GB of DDR3-1600/1333/1066 ECC R/LRDIMMs (LRDIMM = Reduced Load DIMMs) or up to 64GB of ECC UDIMMs. Populating these DIMM modules with a pair of memory modules of the same type and same size will result in interleaved memory, which will improve memory performance.
Figure 5-3. Installing DIMM into Slot
Notch
To In stal l : Inser t module vert ic ally a nd pre ss down unt il it sn aps in to place. Pay a tte ntio n to the ali gnme nt notc h at the bottom.
Front View
Notch
To Remove:
Use your thumbs to gently push the release tabs near both ends of the module. This should release it from the slot.
Release Tab
Note: Notch should align with the receptive key point on the slot.
Top View of DDR3 Slot
5-9
Release Tab
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Memory Population Guidelines
DIMM slots should be populated in the following order: DIMMA1, DIMMB1, DIMMC1, DIMMD1 then DIMMA2, DIMMB2, DIMMC2, DIMMD2.
Always use DDR3 DIMM modules of the same size, type and speed.
Mixed DIMM speeds can be installed, however, all DIMMs will run at the speed
of the slowest DIMM.
An odd-number of modules is supported (1 ,3 ,5 ,or 7 modules). However, for
best memory performance, install DIMM modules in pairs.
Edge of the motherboard
DIMMC1 (Blue Slot) DIMMC2
DIMMD1 (Blue Slot) DIMMD2
DIMMB2 DIMMB1 (Blue Slot)
DIMMA2 DIMMA1 (Blue Slot)
5-10
Chapter 5: Advanced Motherboard Setup
Recommended Population (Balanced)
DIMMA1 DIMMA2 DIMMB1 DIMMB2 DIMMC1 DIMMC2 DIMMD1 DIMMD2 Total
2GB 2GB 4GB 2GB 2GB 2GB 2GB 8GB 2GB 2GB 2GB 2GB 2GB 2GB 12GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 16GB 4GB 4GB 8GB 4GB 4GB 4GB 4GB 16GB 4GB 4GB 4GB 4GB 4GB 4GB 24GB 4GB 4GB 4GB 4GB 4GB 4GB 4GB 4GB 32GB 8GB 8GB 16GB 8GB 8GB 8GB 8GB 32GB 8GB 8GB 8GB 8GB 8GB 8GB 64GB
8GB 8GB 8GB 8GB 8GB 8GB 8GB 8GB 128GB 16GB 16GB 32GB 16GB 16GB 16GB 16GB 64GB 16GB 16GB 16GB 16GB 16GB 16GB 96GB 16GB 16GB 16GB 16GB 16GB 16GB 16GB 16GB 128GB 32GB 32GB 64GB 32GB 32GB 32GB 32GB 128GB 32GB 32GB 32GB 32GB 32GB 32GB 192GB 32GB 32GB 32GB 32GB 32GB 32GB 32GB 32GB 256GB
Memory
5-11
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
5-6 Adding PCI Cards
PCI Expansion Slots
One riser card is used to support a PCI expansion (add-on) card in the system. The SC813MTQ chassis can accommodate one standard size (full height full length) PCI expansion card. When viewed from the chassis front, the card installs to the left rear of the system.
PCI Card Installation
Before installing a PCI add-on card, make sure it is supported by the riser card. Begin by releasing the locking tab that corresponds to the slot you wish to populate. Insert the expansion card into the riser card by pushing down with your thumbs evenly on both sides of the card.
PCI Slot/Card Confi gurations
Riser Card Expansion card supported
RSC-RR1U-E16 (pre -ins talle d) 1x PCI- E 3. 0/2. 0 x16 card
5-12
5-7 Motherboard Details
JCOM2
JPB1
JIPMB1
JTPM1
JUSB4/5
JOH1
JUSB6/7 JUSB8/9
3-SGPIO1 3-SGPIO2
JIBTN1
JUSB2
S-SATA0
FAN A
I-SATA 2.0 5544332
I-SATA 3.0
1
0
JPK1
FAN3
JF1
JTAG1
JWD1
JD1
JL1
FAN2
FAN1
JPW1
JPI2C1
JPW2
JPUSB1
JKBMS1
JCOM1
JVGA
JLAN1
JLAN2
UID SW
UID LED
DP3
JPG1
JI2C1
JI2C2
JSTBY1
JPL2
JPL1
FAN4
JPBIOS1
JPME1 JSD1 JBT1
T-SGPIO2
T-SGPIO1
JLAN_USB12
JLAN3
JLAN4
DP2
S-SATA1 S-SATA2 S-SATA3
Figure 5-4. SUPER X9SRi-F Layout
Chapter 5: Advanced Motherboard Setup
JCOM2
JPB1
JIPMB1
JTPM1
JUSB4/5
JOH1
JUSB6/7
JUSB8/9 3-SGPIO1
3-SGPIO2
JIBTN1
JUSB2
S-SATA0
S-SATA1 S-SATA2 S-SATA3
FAN A
JSTBY1
COM2
JCOM2
6
1
9
5
1
JPB1
3
TPM/PORT80
JTPM1
20
19
1
2
2
7
10 + 2
1
7
1
2
7
10
JUSB89
2
1
3-SGPIO1
8
7
2
1
3-SGPIO2
3-SGPIO23-SGPIO1
7
8
1
JIBTN2
3
USB2
JUSB2
4
41
FANA
DP3
MH1
JSTBY
3
DP3
JIPMB1
JIPMB1
1
P1-DIMM4A
P1-DIMM4B
USB0/1
12
JPW1
FAN1
41
1
JKBMS1
1
JPUSB1
24
1
1
1
SP1
KB/MOUSE
JKBMS1
JPUSB1
2-3 ENable
1-2 Disable
JPUSB1:USB Wake Up
P1-DIMM3A
P1-DIMM3B
DIMM_C1
JTAG1
JPW2
JPW2
3
+
JPW2
5
JVR6
JVR5
3
JVR4 JVR3
3
JPI2C1
3
1
JPI2C1
PWRI2C
JCOM1
JVGA
FAN4
1
1 3
41
FAN4
3
JVR1
OPEN 1st
JD1:
PWR LED
1-3:
SPEAKER
4-7:
C
VGA
A
JPW1
DP2
7
JLAN_USB12
JCOM1
COM1
FAN4
FAN2
JWD1
JL1
JD1
41
LAN1
HDD
PWR
X
JPL2
CLOSE 1st
JF1
NMI
JF1
20
19
JVR2
1 3
JVGA
JPL1/2: LAN 1-2 Enable
JPL11JPL2
2-3 Disable
JPL1
JWD1:Watch Dog 1-2:RST 2-3:NMI
1
UID LED
C
2
A
UID_LED
UID
UID_SW
1
JLAN1
JLAN2
JPG1
JLAN2
MH7
1
4
JLAN4
FAN3
LAN2
P1-DIMM2B
FAIL
PWR
RSTONPWR
FF
T-SGPIO1
2
1
JLAN3
NIC
NICOHLED
1
2
JI2C1
JI2C1
JI2C1/JI2C2
I2C Bus for PCI slot
OFF:DISABLE
ON: ENABLE
PCIE4
X_BT1
MAC CODE
JPBIOS1
JPME1 JSD1 JBT1
I-SATA0
I-SATA0
I-SATA1
I-SATA1
CHASSIS
INTRUSION
UID SW
PCIE6
JI2C2
JI2C2
SLOT6 PCI-E 3.0 X16
SAS CODE
MAC CODE
P1-DIMM2A
P1-DIMM1B
P1-DIMM1A
T-SGPIO2
1
2
2
8
8
7
1
JRK1
T-SGPIO1
T-SGPIO2
7
R927R936
U8
JPB: BMC 1-2 Enable 2-3 Disable
1
JPG1
1-2 Enable
2-3 Disable
JPG1: VGA
Tested to Comply
With FCC Standards
FOR HOME OR OFFICE USE
PCIE5
SLOT4 PCI-E 3.0 X8 (IN X16)
SLOT5 PCI-E 2.0 X4 (IN X16)
JOH1
DESIGNED IN USA
X9SRi-F
REV:1.01
MH5
ON:RECOVER BIOS
JPBIOS_RCV1
OFF:NORMAL
1
3
JPME_RCV1
3
R625
ON:ME IN FORCE UPDATA MODE OFF:NORMAL
JRK1 Pin1:RAID_KEY_PCH Pin2:Ground Pin3:PCH_DYN_SKU
OFF: SLAVE
ON: MASTER
JCF1:Compact Flash
JBT1
1
I-Button Header 1
Power
Flash
Compact
JWF1
1
3
JCF1
I-SATA5
I-SATA5
I-SATA2I-SATA3
I-SATA3 I-SATA2
I-SATA4
I-SATA4
I-SATA 2.0
2
I-SATA 3.0
1
0
JPK1
FAN3
JF1
JTAG1
JWD1
JD1
JL1
FAN2
FAN1
X9SRi-F Quick Reference
Jumper Description Default
JPB1 BMC Enable Pins 1-2 (Enabled) JWD1 Watch Dog Reset Pins 1-2 (Reset) JPUSB1 USB Power Select Pins 2-3 (Dual Power) JPG1 Onboard VGA Enable Pins 1-2 (Enabled) JSTBY1 Wake on LAN Enable Pins 2-3 (Enabled) JI2C1/JI2C2 SMB to PCI-E Slots On (Enabled) JPL1/JPL2 LAN1/LAN2 Enable Pins 1-2 (Enabled) JPBIOS1 BIOS Recovery Pins 1-2 (Normal) JPME1 Intel ME Mode Select Pins 1-2 (Normal) JBT1 CMOS Clear See Section 5-9
5-13
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Connector Description
JCOM1, JCOM2 COM1 Port, COM2 Header JIPMB1 System Management Bus Header (for IPMI) JTPM1 Trusted Platform Module (TPM) Header JUSB 4/5, 6/7, 8/9 Front Acc essib le USB H eader s JOH1 Overhe at LED/Fan Fail 3-SGPIO1
3-SGPIO2 JUSB2 Type A USB port S-SATA 0~3 SATA 2.0 ports (3Gb/s) FAN A, FAN 1~4 Fan Headers I-SATA 0/1 SATA 3.0 ports (6Gb/s) I-SATA 2~5 SATA 2.0 ports (3Gb/s) JPK1 Intel/LSI Software RAID Key Firmware Upgrade Header T-SGPIO1, T-
SGPIO2 JF1 Control Panel Header JD1 Power LED/Speaker Header JL1 Chassis Intrusion Header JPI2C1 Power Supply SMBus I JPW2 8-pin Secondary Power Connector JPW1 24-pin Main ATX Power Connector
Serial General Purpose I/O Headers
Serial General Purpose I/O 1/2 Headers (5V Gen1/Gen 2)
2
C Header
JLAN_USB12 IPMI LAN Port/Backpanel USB 2.0 Port JLAN1, JLAN2 Backpanel Gbit LAN Ports 1, 2 (see page 1-10 for feature
information) UID_SW Unit ID Switch JSD1 Disk On Module (DOM) Power
LED Description Color/State Status
DP2 Power On LED Green: Solid On System is On DP3 IPMI Heartbeat Green/Blinking BMC/IPMI Normal UID LED UID (Unit ID) LED Blue: Solid On UID: On
5-14
Chapter 5: Advanced Motherboard Setup
5-8 Connector Defi nitions
Power Connectors
The 24-pin main power connector (JPW1) is used to provide power to the motherboard. The 8 -pin CPU PWR connector (JPW2) is also required for the pro cess or. These power c onnect ors meet the SSI EPS 12V specifi cation . See the tab l e s on the ri g ht f o r p i n d e fi nitions.
24-Pin Main PWR
8-Pin Processor PWR
ATX Power 24-pin Connector
Pin Defi nitions (JPW1)
Pin# Defi nition Pin # Defi nition 13 +3.3V 1 +3.3V 14 -12V 2 +3.3V 15 COM 3 COM 16 PS_ON 4 +5V 17 COM 5 COM 18 COM 6 +5V 19 COM 7 COM 20 Res (NC) 8 PWR_OK 21 +5V 9 5VSB 22 +5V 10 +12V 23 +5V 11 +12V 24 COM 12 +3.3V
Processor Power
Pin Defi nitions (JPW2)
Pins Defi nition 1 through 4 Ground 5 through 8 +12V
NMI Button
The non-maskable interrupt button header is located on pins 19 and 20 of JF1. Refer to the table on the right for pin defi nitions.
Power LED
The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table on the right for pin defi nitions.
HDD LED
The HDD LED connections are located on pins 13 and 14 of JF1. Attach a cable here to indicate HDD activity. See the table on the right for pin defi nitions.
NMI Button
Pin Defi nitions (JF1)
Pin# Defi nition 19 Control 20 Ground
Power LED
Pin Defi nitions (JF1)
Pin# Defi nition 15 +5V 16 Ground
HDD LED
Pin Defi nitions (JF1)
Pin# Defi nition 13 +5V 14 HD Active
5-15
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
NIC1/NIC2 (LAN1/LAN2)
The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11 and 12 of JF1, and the LED connection for LAN Port 2 is on Pins 9 and 10. NIC1 LED and NIC2 LED are 2-pin NIC LED headers. Attach NIC LED cables to NIC1 LED and NIC2 LED to display network activities for LAN 1 and LAN2. Refer to the table on the right for pin defi nitions.
Overheat (OH)/Fan Fail/Front UID LED
Connect an LED cable to the Front UID and OH/Fan Fail connections on pins 7 and 8 of JF1 to display UID (Unit ID) sig­nals or to provide advanced warnings for chassis overheat/fan failure. Refer to the table on the right for pin defi nitions.
OH/Fan Fail Indicator Status
State Defi nition Off Normal On Overheat Flashing Fan Fail
LAN1/LAN2 LED
Pin Defi nitions (JF1)
Pin# Defi nition 9/11 Vcc 10/12 Ground
OH/Fan Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition 7 Vcc/Blue UID LED 8 OH/Fan Fail LED
Reset Button
The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a the hardware Reset Button on the computer case. Refer to the table on the right for pin defi nitions.
Power Fail LED
The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin defi nitions.
5-16
Reset Button
Pin Defi nitions (JF1)
Pin# Defi nition 3 Reset 4 Ground
PWR Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition 5 Vcc 6 Ground
Power Button
The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. This button can also be confi g- ured to function as a suspend button (see BIOS Setup). To turn off the power in the suspend mode, press the button for at least 4 seconds. Refer to the table on the right for pin defi nitions.
Universal Serial Bus (USB)
Two Universal Serial Bus ports (USB 0/1) are located on the I/O backpanel and an additional six USB ports in three head­ers, USB2/3, 4/5, 12/13 provide front/ back chassis access. USB 11 is a Type A USB connector. (USB cables are not included). See the tables on the right for pin defi nitions.
Chapter 5: Advanced Motherboard Setup
Power Button
Pin Defi nitions (JF1)
Pin# Defi nition 1 Signal 2 +3V Standby
Back Panel USB0/1
Pin Defi nitions
Pin# Defi nition Pin# Defi nition 1 +5V 5 +5V 2 USB_PN1 6 USB_PN0 3 USB_PP1 7 USB_PP0 4 Ground 8 Ground
Front/Back Panel USB2/3, 11, 12/13
USB 2/4/11/12
Pin # Defi nition 1 +5V 6 +5V 2 USB_PN2 7 USB_PN3 3 USB_PP2 8 USB_PP3 4 Ground 9 Ground 5 No Con-
Pin Defi nitions
USB 3/5/13
Pin # Defi nition
10 Key
nection
Serial Ports
The COM1 Port is located on the I/O backpanel. COM2 is a header located on the the motherboard. See the table on the r ight for p in defi nitions.
5-17
Serial Port Pin Defi nitions
(COM1/COM2)
Pin # Defi nition Pin # Defi nition 1 CDC 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RI 5 Ground 10 NC
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Fan Headers
The X9SRi-F has fi ve fan headers (Fan1 ~ Fan4 and FanA). These are all 4-pin fan headers, however pins 1-3 are backward compatible with traditional 3-pin fans. A fan speed control setting in the BIOS (Hardware Monitoring section) allows the BIOS to automatically set fan speeds based on the system temperature. Refer to the table on the right for pin defi nitions.
Note: Please use all 3-pin fans or all 4-pin fans on a motherboard. Do not mix 3-pin fans and 4-pin fans on the same board.
Pin# Defi nition 1 Ground (Black) 2 +12V (Red) 3 Tachometer 4 PWM_Control
Fan Header
Pin Defi nitions
Chassis Intrusion
A Chassis Intrusion header is located at JL1 on the motherboard. Attach the ap­propriate cable from the chassis to inform you of a chassis intrusion when the chas­sis is opened.
ATX PS/2 Keyboard and PS/2 Mouse Ports
The ATX PS/2 keyboard and the PS/2 mouse ports are located beside the USB ports. See the table on the right for pin defi nitions.
Speaker (JD1)
Chassis Intrusion
Pin Defi nitions
Pin# Defi nition 1 Intrusion Input 2 Ground
PS/2 Keyboard and
Mouse Ports
Pin Defi nitions
Pin# Defi nition 1 Data 2NC 3 Ground 4 VCC 5 Clock 6NC
On the JD1 header, Pins 6~7 are used for the internal speaker. Close Pins 6~7 with a jumper or cap to use the onboard speaker. If you wish to use an external speaker, attach the external speaker's cable to Pins 1~4. See the table on the right for pin defi nitions.
5-18
Speaker Connector
Pin Defi nitions
Pin Setting Defi nition Pins 6~7 Internal Speaker Pins 1~3 PWR LED Pins 4~7 External Speaker
Chapter 5: Advanced Motherboard Setup
Trusted Platform Module Header
This header is used to connect a Trusted Platform Module (TPM), available sepa­rately from a third-party vendor. A TPM is a security device that allows encryption and authentication of hard drives, disal­lowing access if the TPM associated with it is not installed in the system. See the table on the right for pin defi nitions.
System Management Bus (JIPMB1)
A System Management Bus header for the IPMI slot is located at IPMB. Con­nect the appropriate cable here to use the IPMB I2C connection on your system.
Trusted Platform Module Header
Pin Defi nitions
Pin # Defi nition Pin # Defi nition 1 LCLK 2 GND 3 LFRAME 4 No Pin 5 LRESET 6 VCC5 7 LAD3 8 LAD2 9 VCC3 10 LAD1 11 LAD0 12 GND 13 RSV0 14 RSV1 15 SB3V 16 SERIRQ 17 GND 18 CLKRUN 19 LPCPD 20 RSV2
System Management
Bus
Pin# Defi nition 1 Clock 2 Ground 3 Data 4 No Connection
Power Supply I2C Connector
The Power Supply (I located at JPI
2
C on the motherboard.
2
C) connector is
This connector monitors the status of the power supply, fan and system tempera­ture. See the table on the right for pin defi nitions.
Wake-On-LAN
The Wake-On-LAN header is located at JSTBY1 on the motherboard. See the tab le on the ri ght for pin defi nitions. (You must also have a LAN card with a Wake-On-LAN connector and cable to use this feature.)
PWR Supply I2C
Pin Defi nitions
Pin# Defi nition 1 Clock 2 Data
3 PWR Fail 4 Ground 5 3.3V
Wake-On-LAN
Pin Defi nitions
(JWOL)
Pin# Defi nition 1 +5V Standby 2 Ground 3 Wake-up
5-19
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
T-SGPIO 1/2 & 3-SGPIO 1/2 Headers
Two T-SGPIO (Serial-Link General Pur­pose Input/Output) headers are located next to the I-SATA ports on the mother­board. Additionally, two 3-SGPIO ports are also located next to JUSB 8/9. These headers are used to communicate with the enclosure management chip in the system. See the table on the right for pin defi nitions.
DOM PWR Connector
The Disk-On-Module (DOM) power con­nector, located at JSD1, provides 5V (Gen1/Gen) power to a solid state DOM storage device connected to one of the SATA ports. See the table on the right for pin defi nitions.
Serial_Link-SGPIO
Pin Defi nitions
Pin# Defi nition Pin Defi nition 1NC 2 NC 3 Ground 4 DATA Out
5 Load 6 Ground 7 Clock 8 NC
DOM PWR Connector
Pin Defi nitions
Pin Defi nition 15V 2 Ground
3 Ground
Unit ID Switch (UID SW)
The rear UID switch, the rear UID LED and front UID LED on JF1 are designed to work together. When the user pushes the rear UID switch, the blue backpanel UID LED and front UID LED will turn on. Push the rear UID switch again to turn off UID LED and the front UID LED. This provides easy identifi cation of a system unit that may be in need of service.
5-20
UID Switch
Pin# Defi nition 1 Button In 2 Ground 3 Ground 4 Ground
Overheat/Fan Fail LED (JOH1)
The JOH1 header is used to connect an LED to provide warnings of chassis over­heat. This LED will also blink to indicate a fan failure. Refer to the table on right for pin defi nitions.
Chapter 5: Advanced Motherboard Setup
Overheat LED
Pin Defi nitions
Pin# Defi nition 1 P3V3 2 OH Active
OH/Fan Fail LED
Pin Defi nitions
State Message Solid Overheat Blinking Fan Fail
Internal Buzzer (SP1)
The Internal Buzzer (SP1) can be used to provide audible indications for various beep codes. See the table on the right for pin defi nitions.
Internal Buzzer
Pin Defi nition
Pin# Defi nitions Pin 1 Pos. (+) Beep In Pin 2 Neg. (-) Alarm
Speaker
5-21
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
5-9 Jumper Settings
Explanation of Jumpers
To modify the operation of the mother­board, jumpers can be used to choose between optional settings. Jumpers cre­ate shorts between two pins to change the function of the connector. Pin 1 is identifi ed with a square solder pad on the printed circuit board. See the diagram at right for an example of jumping pins 1 and
2. Refer to the motherboard layout page for jumper locations.
Note: On t wo-p in jum pe rs, "Closed" m ean s the jumper is on and "Open" means the
Connector
Pins
Jumper
Setting
3 2 1
3 2 1
jumper i s off t he pins.
CMOS Clear
JBT1 is used to clear CMOS and will also clear any passwords. Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS.
To Clear CMOS
1. First power down the system and unplug the power cord(s).
2. With the power disconnected, short the CMOS pads with a metal object such as a small screwdriver.
3. Remove the screwdriver (or shorting device).
4. Reconnect the power cord(s) and power on the system.
Note: Do not use the PW_ON connector to clear CMOS.
VGA Enable/Disable
JPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2 to enable VGA. See the table on the right for jumper settings.
5-22
VGA Enable/Disable
Jumper Settings
Setting Defi nition Pins 1-2 Enabled Pins 2-3 Disabled
PCI Slot SMB Enable
Use Jumpers JI
2
C1/JI2C2 to enable PCI-E SMB (System Management Bus) support to improve system management for the PCI-E slots. Default is disabled. See the table on the right for jumper settings.
Chapter 5: Advanced Motherboard Setup
PCI Slot SMB Enable/Disable
Jumper Settings
Setting Defi nition Closed Enabled Open (Default) Disabled
LAN Port Enable/Disable
Use JPL1/ JPL2 to enable or disable LAN Port s 1 and 2 on the mo therbo ard. See the table on the right for jumper settings. The defau lt set ting is e nable d.
BMC Enable/Disable
JPB is used to enable or disable the BMC (Baseboard Management Control) chip and the onboard IPMI connection. This jumper is used together with the IPMI settings in the BIOS. The default position is on pins 1 and 2 to Enable BMC. See the table on the right for jumper settings.
BIOS Recovery (JPBIOS1)
The BIOS Recovery (JPBIOS) is used to enable or disable the BIOS Recovery fea­ture of the motherboard. Install the jumper on pins 1-2 to begin the recovery process.
LAN Port En/Disable
Jumper Settings
Setting Defi nition 1-2 Enabled 2-3 Disabled
BMC IPMI Enable/Disable
Jumper Settings
Setting Defi nition Pins 1-2 Enabled Pins 2-3 Disabled
BIOS Recovery
Jumper Settings
Setting Defi nition Pins 1-2 Normal Pins 2-3 Recover
Watch Dog Enable
Watch Dog is a sy stem moni tor that c an reboot the system when a software appli­cation hangs. Close pins 1-2 of JWD1 to reset th e system i f an ap pli c ati on ha ngs . Close p ins 2-3 to ge nerate a non -mask­able interrupt signal for the application that hang s. S ee t he t a bl e on t he r i g ht fo r jumper settings. Watch Dog must also be enabled in the BIOS.
5-23
Watch Dog
Jumper Settings
Setting Defi nition Pins 1-2 Reset (default) Pins 2-3 NMI Open Disabled
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
5-10 Onboard Indicators
LAN1/LAN2 LEDs
The Ethernet ports (located beside the VGA port) have two LEDs. On each Giga­bit LAN port, one LED indicates activity when blinking while the other LED may be green, amber or off to indicate the speed of the connection. See the table on the right for the functions associated with the connection speed LED.
Connection Speed Indication
LED State Defi nition Off No connection or 10 Mb/s Green 100 Mbps Amber 1 Gbps
LAN LED
Rear Unit ID LED (UID LED)
The rear Unit ID LED is located at UI D LED on the backpanel. This LED is used in conjunction with the rear UID switch to provide easy identifi cation of a system that might be in need of service.
IPMI Heartbeat LED (DP3)
The IPMI Heartbeat LED is located at DP3. W he n D P 3 b li nks , t he I P MI f eat ur e is functioning properly. Refer to the table on the r ight fo r deta ils. A lso s ee the l ay­out belo w for th e LED loc atio n.
Rear UID LED
LED Indication
Blue: Solid UID Toggled On
IPMI Heartbeat LED Indicator
LED Indication
Green: Blinking IPMI is ready for use
Onboard Power LED (DP2)
An Onboard Power LED is located at PWR LED on the motherboard. When PWR LED is on, it means that the AC power cable is connected, the power sup­ply switch and soft switch are on, and the system is running.
5-24
Onboard Power LED
LED Indication
Status Defi nition Off System Off (Soft Switch) On System is Running
5-11 SATA Ports
SATA Ports
Ten Serial ATA (SATA) ports (I-SATA 0~5 and S-SATA 1~4) are included on the motherboard. See the table on the right for pin defi nitions for the onboard SATA ports.
Chapter 5: Advanced Motherboard Setup
SATA Port Pin Defi nitions
Pin # Defi nition 1 Ground 2 TXP 3 TXN 4 Ground 5 RXN 6 RXP 7 Ground
5-25
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
5-12 Installing Drivers
After all the hardware and operating system have been installed, you need to install certain drivers. The necessary drivers are all included on the Supermicro CD that came packaged with your motherboard. After inserting this CD into your CD-ROM drive, the display shown in Figure 5-4 should appear. (If this display does not appear , click on the My Computer icon and then on the icon representing your CD-ROM drive. Finally, double click on the S "Setup" icon.)
Figure 5-4. Driver Installation Display Screen
Click the icons showing a hand writing on paper to view the readme fi les for each item. Click the tabs to the right of these in order from top to bottom to install each item one at a time. After installing each item, you must reboot the system be- fore moving on to the next item on the list. You should install everything here except for the SUPER Doctor utility, which is optional. The bottom icon with a CD on it allows you to view the entire contents of the CD.
5-26
Chapter 5: Advanced Motherboard Setup
SuperDoctor III
The SuperDoctor® III program is a Web base management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The SuperDoctor III program included on the CD-ROM that came with your motherboard allows you to monitor the environment and operations of your system. SuperDoctor III displays crucial system information such as CPU temperature, system voltages and fan status. See the Figure below for a display of the SuperDoctor III interface.
Note: The default User Name and Password for SuperDoctor III is ADMIN / AD­MIN.
Note: When SuperDoctor is fi rst installed, it adopts the temperature threshold set- tings that have been set in BIOS. Any subsequent changes to these thresholds must be made within SuperDoctor, as the SuperDoctor settings override the BIOS settings. To set the BIOS temperature threshold settings again, you would fi rst need to uninstall SuperDoctor.
SuperDoctor III Interface Display Screen (Health Information)
5-27
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
SuperDoctor III Interface Display Screen (Remote Control)
Note: The SuperDoctor III program and User's Manual can be downloaded from the Supermicro web site at http://www.supermicro.com/products/accessories/software/ SuperDoctorIII.cfm.
For Linux, we recommend using SuperDoctor II.
5-28
Chapter 6: Advanced Chassis Setup
Chapter 6
Advanced Chassis Setup
This chapter covers the steps required to install components and perform mainte­nance on the SC813MTQ chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the step that follows.
Tools Required: The only tool you will need to install components and perform maintainance is a Phillips screwdriver.
6-1 Static-Sensitive Devices
Electrostatic Discharge (ESD) can damage electronic com ponents. To prevent damage to any printed circuit boards (PCBs), it is important to handle them very carefully. The following measures are generally suffi cient to protect your equipment from ESD discharge.
Precautions
Use a grounded wrist strap designed to prevent static discharge.
Touch a grounded metal object before removing any board from its antistatic
bag.
Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or gold contacts.
When handling chips or modules, avoid touching their pins.
Put the serverboard, add-on cards and peripherals back into their antistatic
bags when not in use.
For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and the serverboard.
Unpacking
The serverboard is shipped in antistatic packaging to avoid static damage. When unpacking the board, make sure the person handling it is static protected.
6-1
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Figure 6-1. Chassis Front View
USB Ports
SATA Drives (4)
Figure 6-2. Chassis Rear View
Dedicated IPMI Port
COM2 Port Control Panel
PCI Expansion SlotPower Supply*
Mouse Port
Keyboard Port
USB Ports COM1 Port Ethernet Ports
VGA Port
*The 5017R-MTRF includes two power supplies for redundancy.
6-2 Control Panel
The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system control buttons and status indicators. These wires have been bundled together in a ribbon cable to simplify the connection.
The LEDs inform you of system status. See Chapter 3 for details on the LEDs and the control panel buttons. Details on JF1 can be found in Chapter 5.
6-2
Chapter 6: Advanced Chassis Setup
6-3 Accessing the Inside of the System
You will need to access the inside of the system to perform maintenance such as replacing fans and add-on cards.
1. Grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click").
2. Depress the two buttons on the top of the chassis to release the top cover. Push the cover away from you until it stops.
3. Lift the top cover from the chassis to gain full access to the inside of the server. See Figure 6-3.
Figure 6-3. Accessing the Inside of the System
Release buttons
6-3
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
6-4 System Fans
Four 4-cm high-performance fans provide the cooling for the SuperServer 5017R­MTF/5017R-MTRF. The chassis includes air seals under the fans and at the chassis cross section, which separates the drive bay area from the serverboard area of the chassis to promote better airfl ow. It is highly important that the air seal is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis.
The fans can adjust their speed according to the heat level sensed in the system, which results in more effi cient and quieter fan operation. Fan speed is controlled by a setting in BIOS.
System Fan Failure
If a fan fails, you will need to have it replaced with the same type. Contact your vendor or Supermicro for information on replacement fans.
6-5 Drive Bay Installation/Removal
Removing the Front Bezel
If your system has a front bezel (optional) attached to the chassis, you must fi rst remove it to gain access to the drive bays. To remove the bezel, fi rst unlock the front of the chassis then press the release knob (see Figure 6-3). Carefully re­move the bezel with both hands. A fi lter located within the bezel can be removed for replacement/cleaning. It is recommended that you keep a maintenance log of lter cleaning/replacement, since its condition will affect the airfl ow throughout the whole system.
Figure 6-4. Removing the Front Bezel
6-4
1. Unlock
2. Press release knob
3. Remove bezel assembly
Chapter 6: Advanced Chassis Setup
!
!
Accessing the Drive Bays
SATA Drives: Because of their hotswap capability, you do not need to access the inside of the chassis or power down the system to install or replace SATA drives. Proceed to the next step for instructions. Note: The operating system you use must have RAID support to enable the hot-swap capability of the drives.
DVD-ROM Drive: For installing/removing a DVD-ROM drive, you will need to gain access to the inside of the server by removing the top cover of the chassis. Proceed to the "DVD-ROM Drive Installation" section in this chapter for instructions. Note that only a "slim" DVD-ROM drive will fi t into the 5017R-MTF/5017R-MTRF.
Note: A DVD drive does not come standard with the system.
Use caution when working around the SATA backplane. Do not touch the backplane with any metal objects and make sure no ribbon cables touch the backplane. Also, regardless of how many drives are installed, all four drive carriers must remain in the chassis to maintain proper airfl ow.
Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro Web site at http://www.supermicro.com/products/nfo/fi les/ storage/SAS-1-CompList-110909.pdf
Hard Drive Installation
Mounting a Drive in a Drive Carrier
The hard drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airfl ow for the system. For this reason, even empty carriers without drives installed must remain in the chassis.
1. Install a new drive into the carrier with the printed circuit board side facing down so that the mounting holes align with those in the carrier.
2. Secure the drive to the carrier with six screws, as shown in Figure 6-4.
Installing/Removing Hard Drives
1. To remove a carrier, push the release button located beside the drive LEDs.
2. Swing the colored handle fully out and use it to pull the unit straight out (see Figure 6-5).
Note: There is no onboard RAID support for hard drives.
6-5
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Figure 6-5. Mounting a Drive in a Carrier
SATA Backplane
The SATA drives plug into a backplane that provides power, drive ID and bus termi­nation. A RAID controller can be used with the backplane to provide data security for the drives. The backplane is already preconfi gured, so there are no jumpers or switches present on it.
Figure 6-6. Removing a Drive from the Server
6-6
Chapter 6: Advanced Chassis Setup
DVD-ROM Drive Installation
The top cover of the chassis must be opened to gain full access to the DVD-ROM drive bay . The 5017R-MTF/5017R-MTRF accomodates only slim DVD-ROM drives. Side mounting brackets are needed to mount a slim DVD-ROM drive into the 5017R­MTF/5017R-MTRF server.You must power down the system before installing or removing a DVD-ROM drive. Note that the DVD drive is optional; it does not come already installed in the system but may be installed by the user.
Removing the Chassis Cover
1. Grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click").
2. Depress the two buttons on the top of the chassis to release the top cover and at the same time, push the cover away from you until it stops. You can then lift the top cover from the chassis to gain full access to the inside of the server.
Removing/Installing a Drive
1. With the chassis cover removed, unplug the power and data cables from the drive.
2. Locate the locking tab at the rear of the drive. It will be on the left side of the drive when viewed from the front of the chassis.
3. Pull the tab away from the drive and push the drive unit out the front of the chassis.
4. Add a new drive by following this procedure in reverse order. You may hear a faint *click* of the locking tab when the drive is fully inserted.
5. Remember to reconnect the data and power cables to the drive before replac­ing the chassis cover and restoring power to the system.
6-7
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
6-6 Power Supply
5017R-MTF Power
The SuperServer 5017R-MTF has a single 350 watt power supply. This power sup­ply has the capability of operating at 100 - 240 input volts. Depress the main power button on the front of the chassis and then unplug the AC power cord to completely remove power from the system before removing the power supply.
Power Supply Failure
If the power supply unit fails, the system will shut down and you will need to replace the power supply unit. Replacement units can be ordered directly from Supermicro (see contact infomation in Chapter 1).
Replacing the Power Supply
To replace a power supply, you must fi rst remove the top chassis cover. Follow the procedure on the previous page.
1. First unplug the power cord from the system.
2. To remove the failed power unit, remove the two screws on the back of the power supply, which secure it to the chassis. You can then lift the unit straight out of the chassis.
3. Replace the failed unit with another unit of the same wattage. It is highly recommended to replace it with the exact same power supply.
4. Carefully insert the new unit into position in the chassis and secure it with the two screws at the rear of the unit.
5. Before reconnecting the power cord, make sure the power switch on the power supply is in the off position. Then reconnect the power cord, replace the chassis top cover and push the unit back into the rack.
6. Finish by turning the power switch on the power supply on, and then depress the power button on the front of the system.
6-8
Chapter 6: Advanced Chassis Setup
5017R-MTRF Power
The SuperServer 5017R-MTRF has a 400 watt redundant power supply consisting of two power modules. Each power supply module has an auto-switching capability , which enables it to automatically sense and operate at a 100V - 240V input voltage.
If either of the two power supply modules fail, the other module will take the full load and allow the system to continue operation without interruption. The PWR Fail LED will illuminate and remain on until the failed unit has been replaced. Replace­ment units can be ordered directly from Supermicro. The power supply units have a hot-swap capability, meaning you can replace the failed unit without powering down the system.
Removing the Power Supply
1. First unplug the AC power cord from the failed power supply module.
2. To remove the failed power unit, remove the two screws on the back of the power supply, which secure it to the chassis. You can then lift the unit straight out of the chassis.
3. Replace the failed unit with another unit of the same wattage. You should replace it with the exact same power supply (same model number).
4. Carefully insert the new unit into position in the chassis and secure it with the two screws at the rear of the unit.
5. Before reconnecting the power cord, make sure the power switch on the power supply is in the off position. Then reconnect the power cord, replace the chassis top cover and push the unit back into the rack.
6-9
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Notes
6-10
Chapter 7: BIOS
Chapter 7
BIOS
7-1 Introduction
This chapter describes the AMI BIOS Setup Utility for the X9SRi/X9SRE Mother­board Series. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens. SAS features are not included on the X9SRi.
Note: For instructions on BIOS recovery, please refer to the instruction guide posted at http://www.supermicro.com/support/manuals/.
Starting BIOS Setup Utility
To enter the AMI BIOS Setup Utility screens, press the <Delete> key while the system is booting up.
Note: In most cases, the <Delete> key is used to invoke the AMI BIOS setup screen. There are a few cases when other keys are used, such as <F1>, <F2>, etc.
Each main BIOS menu option is described in this manual. The Main BIOS setup menu screen has two main frames. The left frame displays all the options that can be confi gured. Grayed-out options cannot be confi gured. Options in blue can be confi gured by the user. The right frame displays the key legend. Above the key legend is an area reserved for a text message. When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. (Note: the AMI BIOS has default text messages built in. Supermicro retains the option to include, omit, or change any of these text messages.)
The AMI BIOS Setup Utility uses a key-based navigation system called "hot keys". Most of the AMI BIOS setup utility "hot keys" can be used at any time during the setup navigation process. These keys include <F1>, <F10>, <Enter>, <ESC>, ar­row keys, etc.
Note: Options printed in Bold are default settings.
How To Change the Confi guration Data
The confi guration data that determines the system parameters may be changed by entering the AMI BIOS Setup utility. This Setup utility can be accessed by pressing <Del> at the appropriate time during system boot.
7-1
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
How to Start the Setup Utility
Normally, the only visible Power-On Self-Test (POST) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS Setup Utility. From the main menu, you can access the other setup screens. An AMI BIOS identifi cation string is displayed at the left bottom corner of the screen, below the copyright message.
Warning! Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you have to update the BIOS, do not shut down or reset the system while the BIOS is updating. This is to avoid possible boot failure.
7-2 Main Setup
When you fi rst enter the AMI BIOS Setup Utility , you will enter the Main setup screen. You can always return to the Main setup screen by selecting the Main tab on the top of the screen. The Main BIOS Setup screen is shown below.
7-2
Chapter 7: BIOS
System Overview: The following BIOS information will be displayed:
System Time/System Date
Use this option to change the system time and date. Highlight System Time or Sys­tem Date using the arrow keys. Enter new values through the keyboard. Press the
<Tab> key or the arrow keys to move between fi elds. The date must be entered in Day MM/DD/YY format. The time is entered in HH:MM:SS format. (Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00.)
Supermicro X9SRi/X9SRE Motherboard Series Version Build Date
Processor
The AMI BIOS will automatically display the status of processor as shown below: Processor Speed Physical Count Logical Count
System Memory
This displays the size of memory available in the system: Size
7-3
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
7-3 Advanced Setup Confi gurations
Use the arrow keys to select Boot Setup and hit <Enter> to access the submenu items:
BOOT Feature
Quiet Boot
This option allows the bootup screen options to be modifi ed between POST mes- sages or the OEM logo. Select Disabled to display the POST messages. Select Enabled to display the OEM logo instead of the normal POST messages. The op­tions are Enabled and Disabled.
AddOn ROM Display Mode
This set s the display mode f or Option ROM . The options ar e Force BI OS and Keep Current.
Bootup Num-Lock
This feature selects the Power-on state for Numlock key. The options are Of f and On.
Wait For 'F1' If Error
This for c e s th e syste m to wa it unt il t h e ' F1' key is presse d if a n er r o r oc c ur s . Th e option s are Dis able d and Enabled.
Interrupt 19 Capture
Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt
7-4
Chapter 7: BIOS
!
19 at boot and allow the drives that are attached to these host adaptors to function as bootable disks. If this item is set to Disabled, the ROM BIOS of the host adap­tors will not capture Interrupt 19, and the drives attached to these adaptors will not function as bootable devices. The options are Enabled and Disabled.
Watch Dog Function
If enable d, the Watch Dog Timer will a l l o w the system to reb oot when it is in a ctive for more t han 5 minu tes. The o ption s are Enabl ed and Disabled.
Power Button Function
This feature controls how the system shuts down when the power button is pressed. Select 4-Second Override to force the user to press and hold the Power Button for 4 seconds before the system turns off. Select Instant Off if you want the system to instanty power off when the Power Button is pressed. The options are 4 Second Override and Instant Off.
Restore on AC Power Loss
Use this feature to set the power state after a power outage. Select Power-Off for the system power to remain off after a power loss. Select Power-On for the system power to be turned on after a power loss. Select Last State to allow the system to resume its last state before a power loss. The options are Power-On, Power-Off and Last State.
VFC
This item enables or disables the VESA Feature Connector (VFC) option. The op­tions are Enabled and Disabled.
Processor & Clock Options
Warning: Take Caution when changing the Advanced settings. An incorrect
value, a very high DRAM frequency or incorrect DRAM timing may cause system to become unstable. When this occurs, revert to the default setting.
Clock Spread Spectrum
Select Enable to use the feature of Clock Spectrum, which will allow the BIOS to monitor and attempt to reduce the level of Electromagnetic Interference caused by the components whenever needed. Select Disabled to enhance system stability. The options are Disabled and Enabled.
Hardware Prefetcher (Available when supported by the CPU)
If set to Enabled, the hardware pre fetcher will pre fetch streams of data and instruc­tions from the main memory to the L2 cache in the forward or backward manner to improve CPU performance. The options are Disabled and Enabled.
7-5
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Adjacent Cache Line Prefetch (Available when supported by the CPU)
The CPU fetches the cache line for 64 bytes if this option is set to Disabled. The CPU fetches both cache lines for 128 bytes as comprised if Enabled.
MPS and ACPI MADT Ordering
This feature allows the user to choose the method of ordering for the Multiple APIC Description Table (MADT). Select Modern Ordering if you have the Microsoft Win­dows XP or later version of the OS. Select Legacy Ordering if you use Microsoft Windows 2000 or earlier version of the OS. The options are Modern Ordering and Legacy Ordering.
Intel® Virtualization Technology (Available when supported by the CPU)
Select Enabled to use the feature of Virtualization Technology to allow one platform to run multiple operating systems and applications in independent partitions, creat­ing mult iple " vi r tu al" sy stems i n one p hysic al c o mput er. The opti ons ar e Enabled and Dis abled. Not e: If there is any change to this setting, you will need to power off an d restart the system for the c h ange to take effect. P lease refer to Intel’s web site for detailed information.
Execute-Disable Bit Capability (Available when supported by the OS and the CPU)
Set to Enabled to enable the Execute Disable Bit which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot, thus preventing a worm or a virus from fl ooding illegal codes to overwhelm the processor or damage the system during an attack. The default is
Enabled. (Refer to Intel and Microsoft Web Sites for more information.)
Limit CPUID Maximum
This feature allows the user to set the maximum CPU ID value. Enable this function to boot the legacy operating systems that cannot support processors with extended CPUID functions. The options are Enabled and Disabled (for the Windows OS.).
Intel® Hyper Threading Technology
Set to Enabled to use the processor's Hyper Threading Technology feature. The options are Enabled and Disabled.
Active Processor Cores
Set to Enabled to use a processor's Second Core and beyond. (Please refer to Intel's web site for more information.) The options are All, 1, 2 and 3.
7-6
Chapter 7: BIOS
Power Technology
This feature determines what power-saving scheme the motherboard uses. The options are Disabled, Energy Ef cient and Custom. If Custom is selected, the following options become available:
EIST
EIST (Enhanced Intel SpeedStep Technology) allows the system to automati­cally adjust processor voltage and core frequency in an effort to reduce power consumption and heat dissipation. Please refer to Intel’s web site
for detailed information. The options are Disabled and Enabled.
P-STATE Coordination
This feature selects the type of coordination for the P-State of the processor. P-State is a processor operational state that reduces the processor's voltage and frequency. This makes the processor more energy effi icient, resulting in further gains. The options are HW_ALL, SW_ALL and SW-ANY.
CPU C3 Report, CPU C6, CPU C7 Report
This BIOS feature enables or disables C3 (ACPI C2), C6 (ACPI C3), C7 (ACPI C3) reporting to the operating system. The options are Disabled and Enabled.
Package C State Limit
If set to Auto, the AMI BIOS will automatically set the limit on the C-State package register. The options are C0, C1, C6, C7 and No Limit.
Intel® Turbo Boost Technology (Available if Intel® EIST technology is
Enabled)
Turbo Mode
This feature allows processor cores to run faster than marked frequency in specifi c conditions. The options are Disabled and Enabled.
Long duration power limit - this is the processor power consumption limit (in Watts) during a long duration time window.
Long duration maintained - this is the time in milliseconds where the Long Duration Power Limit is maintained.
Short duration power limit - During Turbo Mode, the system may exceed the processor's default power setting and exceed the Short Duration Power limit. By increasing this value, the processor can provide better performance for a short duration.
7-7
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
DRAM RAPL - this feature enables DRAM Running Average Power Limit. The options are Disabled, Mode 0, and Mode 1.
Chipset Confi guration
WARNING: Setting the wrong values in the following sections may cause the system to malfunction.
North Bridge Confi guration
This item displays the current IO chipset Revision.
Intel I/OAT
The Intel I/OAT (I/O Acceleration Technology) signifi cantly reduces CPU overhead by leveraging CPU architectural improvements, freeing resourc­es for more other tasks. The options are Disabled and Enabled.
Select the TargetVGA
Use this option to select the target VGA device. The options are the cur­rently installed VGA devices.
DCA Support
This feature accelerates the performance of I/O devices using Direct Cache Ac­cess. The options are Enabled and Disabled.
VT-d
Select Enabled to enable Intel's Virtualization Technology support for Direct I/O VT-d
by reporting the I/O device assignments to VMM through
the DMAR ACPI Tables. This feature offers fully-protected I/O resource­sharing across the Intel platforms, providing the user with greater reliabil­ity, security and availability in networking and data-sharing. The settings are Enabled and Disabled.
IOU1 - PCIe Port
This feature enables the user to select bifurcation mode for the selected root port. The options are x4x4 and x8.
Link Speed
This feature enables the user to select the target link speed for the port above. The options are GEN1, GEN2 and GEN3.
IOU2 - PCIe Port
This feature enables the user to select bifurcation mode for the selected root port. The options are x4x4x4x4, x4x4x8, x8x4x4, x8x8 and x16.
7-8
Chapter 7: BIOS
Link Speed
This feature enables the user to select the target link speed for the port above. The options are GEN1, GEN2 and GEN3.
IOU3 - PCIe Port
This feature enables the user to select bifurcation mode for the selected root port. The options are x4x4x4x4, x4x4x8, x8x4x4, x8x8 and x16.
Link Speed
This feature enables the user to select the target link speed for the port above. The options are GEN1, GEN2 and GEN3.
Active State Power Management
Select Enabled to enable Active-State Power Management for signal trans acti ons bet we en L0 and L1 Links on the PCI E xp ress B us in or der to maximize power-saving and transaction speeds. The options are Enabled and Disabled.
PCIE Maximum Payload Size
This feature selects the setting of the PCIE maximum payload size. The options are Auto, 128 Bytes, 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes.
Memory Mode
The options are Independent, Mirroring, Lockstep and Sparing. Independent - All DIMMs are available to the operating system. Mirroring - The motherboard maintains two identical copies of all data in
memory for redundancy. Lockstep - The motherboard uses two areas of memory to run the same
set of operations in parallel. Sparing - A preset threshold of correctable errors is used to trigger fail-
over. The spare memory is put online and used as active memory in place of the failed memory.
NUMA Support
This feature enables the Non-Uniform Memory Access ACPI support. The options are Enabled and Disabled.
DDR Speed
Use this option to force the system memory to run at a different frequency than the default frequency. The available options are Auto, Force DDR­800, Force DDR-1066, Force DDR-1333, and Force DDR3-1600.
7-9
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Channel Interleaving
This feature selects from the different channel memory interleaving meth­ods. The options are Auto, 1 Way, 2 Way, 3 Way and 4 Way.
Rank Interleaving
This feature selects from the different rank memory interleaving methods. The options are Auto, 1 Way, 2 Way, 3 Way, 4 Way and 8 Way.
Patrol Scrub
Patrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected on a memory module and send the correction to the requestor (the original source). When this item is set to Enabled, the North Bridge will read and write back one cache line every 16K cycles, if there is no delay caused by internal processing. By using this method, roughly 64 GB of memory behind the North Bridge will be scrubbed every day. The options are Enabled and Disabled.
Demand Scrub
Demand Scrubbing is a process that allows the CPU to correct correctable memory errors found on a memory module. When the CPU or I/O issues a demand-read command, and the read data from memory turns out to be a correctable error, the error is corrected and sent to the requestor (the original source). Memory is updated as well. Select Enabled to use Demand Scrubbing for ECC memory correction. The options are Enabled and Disabled.
Rank Margin
This feature enables or disables Rank Margin. The options are Enabled and Disabled.
Thermal Throttling
This feature selects from the different throttling methods. The options are Disabled, OLTT and CLTT.
OLTT - Open Loop Thermal Throttling. CLTT - Closed Loop Thermal Throttling.
7-10
Chapter 7: BIOS
South Bridge Confi guration
This item displays the current South Bridge Revision.
SLP_S4 Assertion Stretch Enable
This feature enables or disables Assertion Stretch. The options are
Enabled, and Disabled.
Assertion Width
This feature selects the Assertion Width. The options are 1-2 Seconds, 2-3 Seconds, 3-4 Seconds and 4-5 Seconds.
Deep Sx
Select Enabled to enable Deep Sleep State support. The settings are Enabled and Disabled.
Legacy USB Support
This feature enables support for legacy USB devices. Select Auto to dis­able legacy support if USB devices are not present. Select Disable to have USB devices available only for EFI applicatioins. The options are
Enabled, Disabled and Auto.
BIOS EHCI Hand-Off
This item is for Operating Systems that does not support Enhanced Host Controller Interface (EHCI) hand-off. When enabled, EHCI ownership change will be claimed by the EHCI driver. The settings are Enabled and Disabled.
IDE/SATA Confi guration
When this submenu is selected, the AMI BIOS automatically detects the presence of the IDE Devices and displays the following items:
SATA Mode
This item selects the mode for the installed drives. The options are Disabled, IDE Mode, AHCI Mode and RAID Mode. The following are displayed depending on your selection:
7-11
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
IDE Mode
The following items are displayed when IDE Mode is selected:
Serial-ATA Controller 0~1
This feature is used to activate/deactivate the SATA controller, and sets the compatibility mode. The options are Enhanced and Compatible. The default of Serial-ATA Controller 1 is Enhanced.
SATA Port0~Port5
This item displays the information detected on the installed SATA drives on the particular SATA port.
AHCI Mode
The following items are displayed when AHCI Mode is selected:
Aggressive Link Power Management
This feature Enables or Disables Agressive Link Power Management support for Cougar Point B0 stepping and later. The options are Enabled and Disabled.
SATA Port0~Port5
This item displays the information detected on the installed SATA drives on the particular SATA port.
Staggered Spin Up
Set this item to Enabled to enable Staggered Spin-up support. The options are Enabled and Disabled.
External SATA Port
Set this item to Enabled to enable eSATA support. The options are Enabled and Disabled.
Hot Plug
Set this item to Enabled to enable hot-plugging. The options are Enabled and Disabled.
RAID Mode
The following items are displayed when RAID Mode is selected:
SATA Port0~Port5
This item displays the information detected on the installed SATA drives on the particular SATA port.
7-12
Chapter 7: BIOS
Hot Plug
Set this item to Enabled to enable hot-plugging. The options are Enabled and Disabled.
PCIe/PCI/PnP Confi guration
This feature allows the user to set the PCI/PnP confi gurations for the following items:
PCI ROM Priority
In case of multiple Option ROMs (Legacy and EFI-compatible), this feature specifi es what ROM to launch. The options are Legacy ROM and EFI Compatible ROM.
PCI Latency Timer
This feature sets the latency Timer of each PCI device installed on a PCI bus. Select 64 to set the PCI latency to 64 PCI clock cycles. The options are 32 PCI Bus Clocks, 64 PCI Bus Clocks, 96 PCI Bus Clocks, 128 PCI Bus Clocks, 160 PCI Bus Clocks, 192 PCI Bus Clocks, 224 PCI Bus Clocks and 248 PCI Bus Clocks.
PCIX Slots 1, 2, 3 and PCI-E Slots 4, 5, 6 OPROM
Use this feature to enable or disable PCI slot Option ROMs. The options are Dis­abled and Enabled.
Onboard LAN Option ROM Select
This feature selects whether to load the iSCSI or PXE onboard LAN option ROM. The options are iSCSI and PXE.
Load Onboard LAN1 Option ROM/Load Onboard LAN2 Option ROM
This feature is to enable or disable the onboard option ROMs. The options are
Disabled and Enabled.
Boot Graphics Adapter Priority
This option allows the user to specify which graphics controller to be used as the pri­mary boot device. The options are Slot 6 VGA, Other Slot VGA and Onboard VGA.
Load SAS Option ROM
This feature selects whether to load the SAS option ROM. The options Enabled and Disabled.
7-13
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Super IO Device Confi guration
Serial Port 1 / Serial Port 2
Select Enabled to enable the onboard serial port. The options are Enabled and Disabled.
Serial Port1 Settings/ Serial Port2 Settings
This option specifi es the base I/O port address and the Interrupt Request address of Serial Port 1 and Serial Port 2. Select Disabled to prevent the serial port from accessing any system resources. When this option is set to Disabled, the serial port physically becomes unavailable. Select 3F8/IRQ4 to allow the serial port to use 3F8 as its I/O port address and IRQ 4 for the interrupt address.
The options for Serial Port1 are: Auto, IO=3F8h; IRQ=4; IO=3F8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12; IO=2F8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12; IO=3E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12; IO=2E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12; The options for Serial Port2 are: Auto, IO=2F8h; IRQ=3; IO=3F8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12; IO=2F8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12; IO=3E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12; IO=2E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12;
Serial Port 2 Mode
Use this feature to confi gure Serial Port 2 mode. The options are Normal, IrDA and ASK IR. IrDA (Infrared Data) is an industry standard for remote control devices. ASK IR (Amplitude Shifted Keying Infrared) is a protocol compatible with Sharp® branded PDAs and other infrared devices.
PS/2 KB/MS WakeUp
This feature is used to awaken the system from Standby mode by a PS/2 mouse click or PS/2 keyboard keystroke. The options are S1 (OS Control), S5 (OS Con­trol), Force Enable, and Force Disable.
7-14
Chapter 7: BIOS
Remote Access Confi guration
COM1/COM2/SOL Console Redirection
Use this feature to enable console redirection for COM0 and COM1 ports. The op­tions are Enabled and Disabled. The default for all ports are Disabled.
Console Redirection Settings
Confi gure the following options for the Console Redirection Settings. The most common settings are set as default:
Terminal Type : Select ANSI, VT100, VT100+, or VT-UTF8 Bits per Second (BPS): 9600, 19200, 57600, or 115200 Data Bits: 8 or 7 Parity: None, Even, Odd, Mark, or Space Stop Bits: 1 or 2 Flow Control: None or Hardware RTS/CTS Recorder Mode: Disabled or Enabled Resolution 100x31: Disabled or Enabled Legacy OS Redirection Resolution: 80x24 or 80x25
Serial Port for Out-of-Band Management / Windows Emergency Management Services (EMS)
Use this feature to enable console redirection. The options are Enabled and Dis­abled. The default is Disabled.
Console Redirection Settings
Confi gure the following options for the Console Redirection Settings. The most common settings are set as default:
Out-of-Band Mgmt Port: COM1, COM2, SOL
Terminal Type : Select ANSI, VT100, VT100+, or VT-UTF8 Bits per Second (BPS): 9600, 19200, 57600, or 115200 Flow Control: None, Hardware RTS/CTS, Software Xon/Xoff Data Bits: 8 or 7 Parity: None, Even, Odd, Mark, or Space Stop Bits: 1 or 2
7-15
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Hardware Health Confi guration
Fan Speed Control Mode
This feature allows the user to decide how the system controls the speeds of the onboard fans. The CPU temperature and the fan speed are correlative. When the CPU on-die temperature increases, the fan speed will also increase for effective system cooling. Select "Full Speed" to allow the onboard fans to run at full speed (of 100% Pulse Width Modulation Duty Cycle) for maximum cooling. This setting is recommended for special system confi guration or debugging. Select "Standard" for the onboard fans to run at 50% of the Initial PWM Cycle in order to balance the needs between system cooling and power saving. This setting is recommended for regular systems with normal hardware confi gurations. Select "Optimal" for the onboard fans to run at 30% of the Initial PWM Cycle for best power effi ciency and maximum quietness. The options are Full Speed (@100% of PWM Cycle), Standard (@50% of PWM Cycle), and Optimal (@30% of PWM Cycle).
CPU Temperature Display Mode
This feature displays the CPU temperature detected by DTS (i.e., +34 perature status in text ("Low", "Medium" or "High"). The options are Text Mode or DTS.
CPU Temperature
If Text Mode is selected, the CPU Temperature Display Mode will show the CPU temperature status as follows:
Low – This level is considered as the ‘normal’ operating state. The CPU temperature is well below the CPU ‘Temperature Tolerance’. The mother­board fans and CPU will run normally as confi gured in the BIOS (Fan Speed Control).
User intervention: No action required. Medium – The processor is running warmer. This is a ‘precautionary’ level
and generally means that there may be factors contributing to this condition, but the CPU is still within its normal operating state and below the CPU ‘Temperature Tolerance’. The motherboard fans and CPU will run normally as confi gured in the BIOS. The fans may adjust to a faster speed depending on the Fan Speed Control settings.
o
C) or tem-
User intervention: No action is required. However, consider checking the CPU fans and the chassis ventilation for blockage.
7-16
Chapter 7: BIOS
High – The processor is running hot. This is a ‘caution’ level since the CPU’s ‘Temperature Tolerance’ has been reached (or has been exceeded) and may activate an overheat alarm:
The information provided above is for your reference only. For more information on thermal management, please refer to Intel’s Web site at www.Intel.com.
System Temperature / Peripheral Temperature
This feature displays the system and peripheral device temperatures, as detected by the motherboard sensors.
Fan1 ~ Fan5 Speed
This feature displays the fan speed readings from fan interfaces Fan1 through Fan4 and FanA.
12V, VDIMM, 5VCC, CPU VTT, AVCC, 3.3VCC, VSB, VBAT
This feature displays the current voltages of the above voltage monitors.
ACPI Confi guration
Use this feature to confi gure Advanced Confi guration and Power Interface (ACPI) power management settings for your system.
High Precision Event Timers
Select Enabled to activate the High Performance Event Timer (HPET) that produces periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does in synchronizing multimedia streams, providing smooth playback and reducing the de­pendency on other timestamp calculation devices, such as an x86 RDTSC Instruc­tion embedded in the CPU. The High Performance Event Timer is used to replace the 8254 Programmable Interval Timer. The options are Enabled and Disabled.
Suspend Mode
This setting allows you to confi gure the ACPI (Advanced Confi guration and Power Interface) sleep state for your system when it is in the Suspend mode. The options are Suspend Disabled, and S1 (POS).
WHEA Support
This feature Enables the Windows Hardware Error Architecture (WHEA) support for the Windows 2008 operating system (and later versions). The options are Enabled and Disabled.
7-17
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Network Stack
Use this feature to enable or disable the network stach (PXE and UEFI). The op­tions are Disabled and Enabled.
ME Subsystem
Use this feature to disable or enable the ME (Management Engine) Subsystem. This section also displays the current status of the ME Subsystem. The options are Disabled and Enabled.
7-18
Chapter 7: BIOS
7-4 Event Logs
Smbios Event Log
Change this item to enable or disable all features of the Smbios Event Logging during boot. The options are Enabled and Disabled.
Runtime Error Logging Support Change this item to enable or disable runtime error logging. The options are En-
abled and Disabled.
PCI Error Logging Support
Change this item to enable or disable runtime error logging. The options are En­abled and Disabled.
Memory Correction Error Threshold
Change this item to defi ne the system's memory correction error threshold. Directly enter a numeric value, default is 10.
Erase Event Log
This option erases all logged events. The options are No, Yes, Next reset and Yes, Every reset.
When Log is Full
This option automatically clears the Event Log memory of all messages when it is full. The options are Do Nothing and Erase Immediately.
7-19
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
MECI
The Multiple Event Count Increment (MECI) counter counts the number of oc­curences a duplicate event must happen before the MECI counter is incremented. This is a numeric value.
METW
The Multiple Event Time Window (METW) defi nes number of minutes must pass between duplicate log events before MECI is incremented. This is in minutes, from 0 to 99.
7-5 IPMI
Intelligent Platform Management Interface (IPMI) is a set of common interfaces that IT administrators can use to monitor system health and to manage the system as a whole. For more information on the IPMI specifi cations, please visit Intel's website at www.intel.com.
BMC Support
This feature enables or disables the installed Baseboard Management Controller (BMC) on the motherboard. The options are Enabled and Disabled.
Wait For BMC
If enabled, the system will wait for a BMC response after the AC power is turned on. It takes around 30 seconds to initialize Host to BMC interfaces. The options are Disabled and Enabled.
7-20
Chapter 7: BIOS
BMC Self Test Log
This feature logs any BMC messages returned during a BMC self-test. It shows the total number of entries and will allow the viewing of each event by scrolling down.
Erase Log - Select Yes, On every reset or No. When Log is Full - Select Clear Log or Do Not Log Anymore.
System Event Log
This feature is used to change the Sytem Event Log (SEL) confi guration.
SEL Components - Change this item to enable or disable all features of System Event Logging. The options are Enabled and Disabled. When Enabled, the following can be confi gured:
Erase SEL - This option erases all logged SEL events. The options are No, Yes, On Next reset and Yes, On Every reset.
When SEL Full
This option automatically clears the System Event Log memory of all messages when it is full. The options are Do Nothing and Erase Immediately.
Log EFI Status Codes
This option enables or disables the logging of Extensible Firmware Interface (EFI) status codes. The options are Disabled, Both, Error Code and Progress Code.
BMC Network Con guration
Set this feature to confi gure the IPMI LAN adapter with a network address.
Confi guration Source
This feature selects whether the IP address, Subnet Mask and Gateway Address are automatically assigned by the network's DHCP server (Dynamic Host and Con­ guration Protocol) "Dynamic" or manually entered by the user "Static". If Static is selected, the IP Address, Subnet Mask and Gateway Address must be manually entered below. When Dynamic is selected, all the options below are automatically assigned to the system by itself or by an external DHCP server.
The options are Unspeci ed, Static, Dynamic-obtained by BMC, Dynamic-Loaded by BIOS, and Dynamic-BMC running other Protocol. The following items are dis­played when Static is selected:
Station IP Address - Enter the IP address for this machine. This should be in decimal and in dotted quad form (i.e., 192.168.10.253). The value of each three­digit number separated by dots should not exceed 255.
7-21
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Subnet Mask - Subnet masks tell the network which subnet this machine be­longs to. The value of each three-digit number separated by dots should not exceed 255.
Station MAC Address - MAC addresses are 6 two-digit hexadecimal numbers (Base 16, 0 ~ 9, A, B, C, D, E, F) separated by dots (i.e., 00.30.48.D0.D4.60).
Router IP Address - Enter the Gateway or Router address this machine will use (i.e., 192.168.10.1).
Router MAC Address - Enter the MAC address of the Router or Gateway (only if needed).
7-6 ISCSI
When sharing the iSCSI devices on this machine (iSCSI target), this section is used to enter the worldwide unique name of an iSCSI initiator. An iSCSI initiator application must be confi gured on the machine that will access the iSCSI drives in this machine.
Only IQN (iSCSI Qualifi ed Names) names are accepted. Please research RFC 3720 and RFC 3721 at the Internet Engineering Task Force website (IETF -- www. ietf.org) for more information on iSCSI.
7-22
7-7 Boot Settings
Chapter 7: BIOS
Use this fe ature to co nfi gure Boot Settings:
Boot Options Priority
This feature allows the user to specify which devices are boot devices and the order of priority from which the systems boots from during startup.
Boot Option #1, Boot option #2, Boot Option #3, etc The settings are Built-in EFI Shell, [any detected boot device] and Disabled.
Network Devices
This option sets the order of the legacy network devices detected by the motherboard..
Delete Boot Option
This feature allows the user to delete a previously defi ned boot device from which the systems boots from during startup.
Boot Option #1, Boot option #2, Boot Option #3, etc
The settings are Built-in EFI Shell, and [any pre defi ned boot device]
7-23
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
7-8 Security Settings
If the Administrator password is defi ned ONLY - this controls access to the BIOS setup ONLY.
If the User's password is defi ned ONLY - this password will need to be entered during each system startup or boot, and will also have Administrator rights in the setup.
Passwords must be at least 3 and up to 20 characters long.
Administrator Password
Press Enter to create a new, or change an existing Administrator password.
User Password:
Press Enter to create a new, or change an existing User password.
Boot Sector Virus Protection
When Enabled, the BIOS displays a warning when any program (or virus) issues a Disk Format command or attempts to write to the boot sector of the hard disk drive. The options are Enabled and Disabled.
7-24
7-9 Exit Options
Chapter 7: BIOS
Select the Exit tab from the BIOS Setup Utility screen to enter the Exit BIOS Setup screen.
Save Changes and Exit
When you have completed the system confi guration changes, select this option to leave the BIOS Setup Utility and reboot the computer, so the new system con­ guration parameters can take effect. Select Save Changes and Exit from the Exit menu and press <Enter>.
Discard Changes and Exit
Select this option to quit the BIOS Setup without making any permanent changes to the system confi guration, and reboot the computer. Select Discard Changes and Exit from the Exit menu and press <Enter>.
Discard Changes
Select this option and press <Enter> to discard all the changes and return to the AMI BIOS Utility Program.
Restore Defaults
To set this feature, select Restore Defaults from the Exit menu and press <Enter>. These are factory settings designed for maximum system stability, but not for maximum performance.
7-25
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Save As User Defaults
To set this feature, select Save as User Defaults from the Exit menu and press <En­ter>. This enables the user to save any changes to the BIOS setup for future use
Restore User Defaults
To set this feature, select Restore User Defaults from the Exit menu and press <En­ter>. Use this feature to retrieve user-defi ned settings that were saved previously.
Boot Override
Set this feature to override a previously defi ned boot device. The available devices will be listed below.
7-10 Main Confi guration Page
Port Confi guration Menu
Use this feature to confi gure network-related options.
Preboot Option ROM
This option enables or disables the Option ROM for the current port. When disabled, the preboot driver can be loaded from this location. The options are Enabled and Disabled.
7-26
Chapter 7: BIOS
Link Speed
This feature changes the link speed and duplex mode for the current port. The options are AutoNeg, 10 Mbps H alf, 10 Mbps Full, 10 0 Mbp s Half a nd 100 M bps Full.
Wake On LAN
This feature enables or disables the current port's Wake On LAN feature. When enabled, the system can be 'awaken' by sending a magic packet signal through the enabled LAN port. The options are Enabled and Disabled.
Port Confi guration Information
This section displays information on the following devices: Factory MAC address, Alternate MAC address, UEFI driver version, PCI
Bus:Device:Function, Chip Type, Adapter PBA and Link Status.
7-27
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Notes
7-28
Appendix A: POST Error Beep Codes
Appendix A
POST Error Beep Codes
During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur.
Non-fatal errors are those which, in most cases, allow the system to continue with bootup. The error messages normally appear on the screen.
Fatal errors will not allow the system to continue to bootup. If a fatal error occurs, you should consult with your system manufacturer for possible repairs.
These fatal errors are usually communicated through a series of audible beeps. The numbers on the fatal error list correspond to the number of beeps for the cor­responding error.
POST Error Beep Codes
Beep Code/LED Error Message Description
1 beep Refresh Circuits have been reset.
(Ready to power up)
5 short beeps + 1 long beep
8 beeps Display memory
OH LED On System OH System Overheat
Memory error No memory detected in the
system Video adapter missing or with
read/write error
faulty memory
A-1
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Notes
A-2
Appendix B: UEFI BIOS Recovery
!
Appendix B
UEFI BIOS Recovery Instructions
Warning! Do not upgrade the BIOS unless your system has a BIOS-related
issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you need to update the BIOS, do not shut down or reset the system while the BIOS is updating to avoid possible boot failure.
B-1 An Overview to the UEFI BIOS
The Unifi ed Extensible Firmware Interface (UEFI) specifi cation provides a software- based interface between the operating system and the platform fi rmware in the pre-boot environment. The UEFI specifi cation supports an architecture-independent mechanism for add-on card initialization to allow the UEFI OS loader, which is stored in the add-on card, to boot up the system. UEFI offers a clean, hand-off control to a computer system at bootup.
B-2 How to Recover the UEFI BIOS Image (-the Main BIOS Block)
An AMIBIOS fl ash chip consists of a boot sector block and a main BIOS code block (a main BIOS image). The boot sector block contains critical BIOS codes, including memory detection and recovery codes for the user to fl ash a new BIOS image if the original BIOS image is corrupted. When the system power is on, the boot sector codes execute fi rst. Once it is completed, the main BIOS code will continue with system initialization and bootup.
Note: Follow the BIOS Recovery instructions below for BIOS recovery when the main BIOS block crashes. However, when the BIOS Boot sector crashes, you will need to send the motherboard back to Supermicro for RMA repair.
B-3 To Recover the Main BIOS Block Using a USB­Attached Device
This feature allows the user to recover a BIOS image using a USB-attached device without additional utilities used. A USB fl ash device such as a USB Flash Drive, or a USB CD/DVD ROM/RW device can be used for this purpose. However, a USB Hard Disk drive cannot be used for BIOS recovery at this time.
B-1
SUPERSERVER 5017R-MTF/5017R-MTRF User's Manual
Recovery
To perform UEFI BIOS recovery using a USB-attached device, follow the instruc­tions below.
1. Using a different machine, copy the "Super.ROM" binary image fi le into the disc Root "\" Directory of a USB device or a writeable CD/DVD.
Note: If you cannot locate the "Super.ROM" fi le in your driver disk, visit our website at www.supermicro.com to download the BIOS image into a USB fl ash device and rename it to "Super ROM" for BIOS recovery use.
2. Insert the USB device that contains the new BIOS image ("Super.Rom") into your USB drive and power on the system
3. While powering on the system, keep pressing <Ctrl> and <Home> simultane­ously on your PS2 or USB keyboard until your hear two short beeps. This may take from a few seconds to one minute.
4. After locating the new BIOS binary image, the system will enter the BIOS Recovery page as shown below.
Note: At this point, you may decide if you want to start with BIOS Recovery. If you decide to proceed with BIOS Recovery, follow the procedures below.
Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
Main Advanced Event Logs IPMI Boot Security Exit
WARNING! BIOS Recovery Mode has been detected
Flash Update Parameters
Reset NVRAM
Proceed with Flash Update
[Enabled]
Recovery
Set this to start ash update
 : Select Screen  : Select Item
Enter: Select +/- : Change Opt. F1 : General Help F2 : Previous Values F3 : Optimized Defaults F4 : Save & Exit ESC : Exit
Version 2.12.1211. Copyright (C) 2011 American Megatrends, Inc.
5. When the screen as shown above displays, using the arrow key, select the item- "Proceed with fl ash update" and press the <Enter> key. You will see the progress of BIOS Recovery as shown in the screen below.
Note: Do not interrupt the process of BIOS fl ashing until it is completed.
B-2
Loading...