Supermicro SUPERSERVER 8044T-8R User Manual

SUPER
SUPERSERVER 8044T-8R
®
USER’S MANUAL
1.0
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
SUPERMICRO COMPUTER reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documenta­tion may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO COMPUTER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, THE VENDOR SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
Manual Revision 1.0
Release Date: December 28, 2006
Unless you request and receive written permission from SUPER MICRO COMPUTER, you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2006 by SUPER MICRO COMPUTER INC. All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the SuperServer 8044T-8R. In-
stallation and maintenance should be performed by experienced technicians only.
The SuperServer 8044T-8R is a high-end server based on the SC748TS-R1200P
chassis and the X6QT8, a high-end serverboard that supports four Dual-Core Intel
®
Xeon
7100 Series processors at a Front Side (System) Bus speed of 800/667 MHz
and up to 64 GB of registered ECC DDR2-400 SDRAM.
Preface
®
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the
server system and describes the main features of the X6QT8 serverboard and the
SC748TS-R1200P chassis, which comprise the SuperServer 8044T-8R.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 8044T-8R into
a rack and check out the server confi guration prior to powering up the system. If
your server was ordered without processor and memory components, this chapter
will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
iii
SUPERSERVER 8044T-8R User's Manual
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 8044T-8R.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X6QT8 serverboard, including the
locations and functions of connections, headers and jumpers. Refer to this chapter
when adding or removing processors or main memory and when reconfi guring the
serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC748TS-R1200P server chassis.
You should follow the procedures given in this chapter when installing, removing
or reconfi guring SCSI/SATA or peripheral drives and when replacing system power
supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa-
tion on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes
Appendix B: BIOS POST Checkpoint Codes
Appendix C: System Specifi cations
iv
Notes
Preface
v
SUPERSERVER 8044T-8R User's Manual
Table of Contents
Preface
About This Manual ...................................................................................................... iii
Manual Organization ................................................................................................... iii
Chapter 1: Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Serverboard Features ..................................................................................... 1-2
1-3 Server Chassis Features ................................................................................ 1-3
1-4 Contacting Supermicro ................................................................................... 1-6
Chapter 2: Server Installation
2-1 Overview ......................................................................................................... 2-1
2-2 Unpacking the System ................................................................................... 2-1
2-3 Preparing for Setup ........................................................................................ 2-1
2-4 Installing the System into a Rack ................................................................... 2-4
2-5 Checking the Serverboard Setup ................................................................... 2-8
2-6 Checking the Drive Bay Setup ....................................................................... 2-9
Chapter 3: System Interface
3-1 Overview ......................................................................................................... 3-1
3-2 Control Panel Buttons .................................................................................... 3-1
Reset ........................................................................................................ 3-1
Power ....................................................................................................... 3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
Power Fail ................................................................................................ 3-2
Overheat/Fan Fail .................................................................................... 3-2
NIC2 ......................................................................................................... 3-2
NIC1 ......................................................................................................... 3-2
HDD .......................................................................................................... 3-3
Power ....................................................................................................... 3-3
3-4 Drive Carrier LEDs ......................................................................................... 3-3
Chapter 4: System Safety
4-1 Electrical Safety Precautions .......................................................................... 4-1
4-2 General Safety Precautions ........................................................................... 4-2
4-3 ESD Precautions ............................................................................................ 4-3
4-4 Operating Precautions .................................................................................... 4-4
vi
Table of Contents
Chapter 5: Advanced Serverboard Setup
5-1 Handling the Serverboard .............................................................................. 5-1
5-2 Processor and Heatsink Installation ............................................................... 5-2
5-3 Connecting Cables ......................................................................................... 5-5
Connecting Data Cables .......................................................................... 5-5
Connecting Power Cables ....................................................................... 5-5
Connecting the Control Panel .................................................................. 5-6
5-4 I/O Ports ......................................................................................................... 5-7
5-5 Installing Memory ........................................................................................... 5-7
5-6 Adding PCI Cards ........................................................................................... 5-9
5-7 Serverboard Details ...................................................................................... 5-10
X6QT8 Layout ........................................................................................ 5-10
X6QT8 Quick Reference ........................................................................ 5-11
5-8 Connector Defi nitions ................................................................................... 5-12
ATX Power Connector ........................................................................... 5-12
Processor Power Connectors ................................................................ 5-12
NMI Button ............................................................................................. 5-12
Power LED ............................................................................................. 5-12
HDD LED ............................................................................................... 5-13
NIC1 LED ............................................................................................... 5-13
NIC2 LED ............................................................................................... 5-13
Overheat/Fan Fail LED .......................................................................... 5-13
Power Fail LED ...................................................................................... 5-14
Reset Button .......................................................................................... 5-14
Power Button .......................................................................................... 5-14
Universal Serial Bus Ports (USB0/1) ..................................................... 5-14
Universal Serial Bus Headers ................................................................ 5-15
Serial Ports ............................................................................................. 5-15
Fan Headers .......................................................................................... 5-15
Chassis Intrusion .................................................................................... 5-15
Power LED/Speaker ............................................................................... 5-16
ATX PS/2 Keyboard and Mouse Ports .................................................. 5-16
Overheat LED ........................................................................................ 5-16
Wake-On-LAN ........................................................................................ 5-16
Wake-On-Ring ........................................................................................ 5-17
SMBUS ................................................................................................... 5-17
PS_SMBUS ............................................................................................ 5-17
Alarm Reset ........................................................................................... 5-17
LAN1/2 Ethernet Ports ........................................................................... 5-18
vii
SUPERSERVER 8044T-8R User's Manual
Compact Flash Card PWR (Master) ...................................................... 5-18
Compact Flash Card PWR (Slave) ........................................................ 5-18
5-9 Jumper Settings ............................................................................................ 5-19
Explanation of Jumpers ......................................................................... 5-19
CMOS Clear ........................................................................................... 5-19
VGA Enable/Disable ............................................................................... 5-19
3rd Power Supply Fail Detect Enable/Disable ....................................... 5-20
LAN Enable/Disable ............................................................................... 5-20
Watch Dog Enable/Disable .................................................................... 5-20
Front Side Bus Speed Select ................................................................ 5-21
5-10 Onboard Indicators ....................................................................................... 5-21
LAN1/LAN2 LEDs .................................................................................. 5-21
5-11 Floppy, IDE and SATA Drive Connections ................................................... 5-22
Floppy Connector ................................................................................... 5-22
IDE Connectors ...................................................................................... 5-23
SATA Ports ............................................................................................. 5-23
Chapter 6: Advanced Chassis Setup
6-1 Static-Sensitive Devices ................................................................................. 6-1
6-2 Control Panel .................................................................................................. 6-3
6-3 System Fans ................................................................................................... 6-4
Fan Failure ............................................................................................... 6-4
Replacing Chassis Fans .......................................................................... 6-4
6-4 Drive Bay Installation ...................................................................................... 6-6
SCSI Drives .............................................................................................. 6-6
Installing Components into the 5.25" Drive Bays .................................... 6-8
6-5 Power Supply ................................................................................................. 6-9
Power Supply Failure ............................................................................... 6-9
Removing/Replacing the Power Supply ................................................... 6-9
Chapter 7: BIOS
7-1 Introduction ..................................................................................................... 7-1
7-2 Main Setup ..................................................................................................... 7-2
7-3 Advanced Settings .......................................................................................... 7-3
7-4 Boot Settings ................................................................................................ 7-16
7-5 Security Settings ........................................................................................... 7-18
7-6 Exit Options .................................................................................................. 7-19
viii
Table of Contents
Appendices:
Appendix A: BIOS Error Beep Codes ...................................................................... A-1
Appendix B: BIOS POST Checkpoint Codes .......................................................... B-1
Appendix C: System Specifi cations ........................................................................ C-1
ix
S
UPERSERVER 8044T-8R User's Manual
Notes
x
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The SuperServer 8044T-8R is a high-end server that is comprised of two main
subsystems: the SC748TS-R1200P 4U/tower server chassis and the X6QT8 quad
Intel Xeon processor serverboard. Please refer to our web site for information on
operating systems that have been certifi ed for use with the SuperServer 8044T-8R
(www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have
been included with the SuperServer 8044T-8R, as listed below:
Three (3) 8-cm hot-swap exhaust fans (FAN-0081)
Three (3) 9-cm hot-swap chassis fans (FAN-0090)
One (1) air shroud (CSE-PT0125)
Four (4) CPU passive heatsinks (SNK-P0029P)
One (1) slim fl oppy drive (FPD-PNSC-W1.44MB)
One (1) fl oppy cable (CBL-0051L)
One (1) I/O shield (CSE-PT55L)
SCSI Accessories
One (1) SCSI backplane (CSE-SCA-016)
One (1) SCSI cable (CBL-0063L)
One (1) 5-drive mobile rack (CSE-M35S)
Three (3) dummy drives w/ rails (CSE-PT36)
Rackmount hardware kit (MCP-290-00001-00)
One (1) SuperServer 8044T-8R User's Manual
Note: a "B" following a part number (8044T-8RB) indicates black.
1-1
S
UPERSERVER 8044T-8R User's Manual
1-2 Serverboard Features
At the heart of the SuperServer 8044T-8R lies the X6QT8, a quad processor
serverboard based on the Intel E8501 chipset. Below are the main features of the
X6QT8. (See Figure 1-1 for a block diagram of the E8501 chipset).
Processors
The X6QT8 supports four 604-pin Intel Xeon 7100 Series processors at a FSB
speed of 800/667 MHz. Please refer to the serverboard description pages on our
web site for a complete listing of supported processors (www.supermicro.com).
Memory
The X6QT8 has sixteen 240-pin DIMM slots that can support up to 64 GB of ECC
DDR2-400 SDRAM. The memory operates in an interleaved confi guration and re-
quires requires modules of the same size and speed to be installed two at a time.
See Chapter 5 Section 5 for details.
Onboard SCSI
An onboard Adaptec AIC-7902W dual-channel SCSI controller in integrated into the
X6QT8, which supports eight 80-pin SCA Ultra320 SCSI hard drives. RAID 0, 1,
10 and JBOD are supported. The SCSI drives are connected to an SCA backplane
that provides power, bus termination and confi guration settings. The SCSI drives
are hot-swappable units. Note: HostRAID supports only four drives.
Serial ATA
A SATA controller is integrated into the South Bridge of the E8501 chipset to pro-
vide a two-port SATA subsystem, which is RAID 0, 1 and JBOD supported. The
SATA drives are hot-swappable units.
PCI Expansion Slots
The X6QT8 has six PCI expansion slots, which includes one PCI-Express x8 slot,
one PCI-Express x4 slot, three 64-bit 133 MHz PCI-X slots and one 64-bit 100 MHz
PCI-X slot. (The 100 MHz PCI-X slot supports Zero Channel RAID.)
1-2
Chapter 1: Introduction
Onboard Controllers/Ports
One fl oppy drive controller and two onboard ATA/100 controllers are provided to
support up to four IDE hard drives or ATAPI devices. The color-coded I/O ports
include one COM port (an additional COM header is located on the serverboard),
a VGA (monitor) port, two USB 2.0 ports, PS/2 mouse and keyboard ports and two
Gb Ethernet ports.
ATI Graphics Controller
The X6QT8 features an integrated ATI video controller based on the 16 MB ES1000
graphics chip. The ES1000 was designed specifi cally for servers, featuring low
power consumption, high reliability and superior longevity.
IPMI
IPMI (Intelligent Platform Management Interface) is a hardware-level interface speci-
fi cation that provides remote access, monitoring and administration for Supermicro
server platforms. IPMI allows server administrators to view a server’s hardware
status remotely, receive an alarm automatically if a failure occurs, and power cycle
a system that is non-responsive.
Other Features
Other onboard features that promote system health include onboard voltage moni-
tors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU
overheat sensors, virus protection and BIOS rescue.
1-3
S
UPERSERVER 8044T-8R User's Manual
1-3 Server Chassis Features
The following is a general outline of the main features of the SC748TS-R1200P
server chassis.
System Power
The SC748TS-R1200P features a redundant (two separate power modules) 1200W
high-effi ciency power supply with I
to replace a failed power supply without shutting down the system.
SCSI Subsystem
The SC748TS-R1200P chassis was designed to support fi ve dual-channel, hot-
swappable SCSI hard drives. The SCSI backplane provides SAF-TE functions
for the SCSI drives.
2
C. This power redundancy feature allows you
Front Control Panel
The control panel on the SuperServer 8044T-8R provides you with system monitor-
ing and control. LEDs indicate system power, HDD activity, network activity, system
overheat and power supply failure. A main power button and a system reset button
are also included. In addition, two USB ports have been incorporated into the front
of the chassis for convenient access.
I/O Backplane
The SC748TS-R1200P is an tower chassis that can also be used in a 4U rackmount
confi guration. The I/O backplane provides seven PCI expansion slots, one COM
port, a VGA port, two USB 2.0 ports, PS/2 mouse and keyboard ports and two Gb
Ethernet ports.
Cooling System
Three 9-cm hot-swap system cooling fans located in the middle section of the
chassis and three 8-cm hot-swap exhaust fans are used to cool the system. An air
shroud channels the airfl ow from the system fans to effi ciently cool the processors
and DIMMs. Each power supply module also include a cooling fan.
1-4
Chapter 1: Introduction
Figure 1-1. Intel E8501 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
133 MHz PCI-X (Slot 4)
133 MHz PCI-X (Slot 3)
PCI-Express x8 (Slot 6 )
PCI-Express x4 (Slot 5 )
133 MHz PCI-X (Slot 2)
100 MHz PCI-X (Slot 1)
SCSI
AIC-7902W
Intel 7100 Series
CPU #1
ADD R
CTRL
Intel 7100 Series
CPU #2
Gb LAN
PXH #2
PXH #1
ATA100
SATA
Ports (2)
USB 2.0
DATA
ADDR/DATA/CTRL
ADDR/DATA/CTRL
E8501
(North Bridge)
ICH5R
(South Bridge)
Intel 7100 Series
CPU #3
ADD R
CTRL
Intel 7100 Series
CPU #4
DDR2-400
DDR2-400
DDR2-400
DDR2-400
32-bit PCI
bus
ES1000
ATI
DATA
DIMM A7
DIMM B7
DIMM A8
DIMM B8
DIMM A5
DIMM B5
DIMM A6
DIMM B6
DIMM A1
DIMM B1
DIMM A2
DIMM B2
DIMM A3
DIMM B3
DIMM A4
DIMM B4
Kybrd/
Mouse
LPC
I/O
Floppy
1-5
BMC BIOS
COM1/
COM2
Monitor
H/W
S
UPERSERVER 8044T-8R User's Manual
1-4 Contacting Supermicro
Headquarters
Address: SuperMicro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com
Europe
Address: SuperMicro Computer B.V. Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information) support@supermicro.nl (Technical Support) rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: SuperMicro, Taiwan 4F, No. 232-1, Liancheng Rd. Chung-Ho 235, Taipei, Taiwan, R.O.C. Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Web Site: www.supermicro.com.tw Technical Support: Email: support@supermicro.com.tw Tel: 886-2-8228-1366, ext.132 or 139
1-6
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your 8044T-8R up and running.
Following these steps in the order given should enable you to have the system
operational within a minimum amount of time. This quick setup assumes that your
system has come to you with the processors and memory preinstalled. If your sys-
tem is not already fully integrated with a serverboard, processors, system memory
etc., please turn to the chapter or section noted in each step for details on installing
specifi c components. The 8044T-8R may be employed either as a tower or mounted
in a rack as a 4U rackmount chassis. If using it as a tower unit, please read the
Server Precautions in the next section and then skip ahead to Section 2-5.
2-2 Unpacking the System
You should inspect the box the system was shipped in and note if it was damaged
in any way. If the server itself shows damage you should fi le a damage claim with
the carrier who delivered it.
Decide on a suitable location for the 8044T-8R. It should be situated in a clean,
dust-free area that is well ventilated. Avoid areas where heat, electrical noise
and electromagnetic fi elds are generated. You will also need it placed near a
grounded power outlet. Be sure to read the Rack and Server Precautions in the
next section.
2-3 Preparing for Setup
The box the system was shipped in may include two sets of rail assemblies, two
rail mounting brackets and mounting screws needed for installing the system into a
rack (optional kit). Follow the steps in the order given to complete the installation
process in a minimum amount of time. Please read this section in its entirety before
you begin the installation procedure outlined in the sections that follow.
2-1
S
UPERSERVER 8044T-8R User's Manual
Choosing a Setup Location
- Leave enough clearance in front of the system to enable you to open the front
door completely (~25 inches).
- Leave approximately 30 inches of clearance in the back of the system to allow for
suffi cient airfl ow and ease in servicing.
-This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets and the like).
!
Warnings and Precautions!
!
Rack Precautions
- Ensure that the leveling jacks on the bottom of the rack are fully extended to the
fl oor with the full weight of the rack resting on them.
- In single rack installation, stabilizers should be attached to the rack.
- In multiple rack installations, the racks should be coupled together.
- Always make sure the rack is stable before extending a component from the
rack.
- You should extend only one component at a time - extending two or more simul-
taneously may cause the rack to become unstable.
Server Precautions
- Review the electrical and general safety precautions in Chapter 4.
- Determine the placement of each component in the rack before you install the
rails.
- Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
- Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power
failure.
-
Allow the hot plug SCSI drives and power supply units to cool before touching
them.
-
Always keep the rack's front door and all server panels and covers closed when
not servicing to maintain proper cooling.
2-2
Chapter 2: Server Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
2-3
S
UPERSERVER 8044T-8R User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the system into a rack unit. Rack
installation requires the use of the optional rackmount kit If the system has already
been mounted into a rack or if you are using it as a tower, you can skip ahead to
Sections 2-5 and 2-6. There are a variety of rack units on the market, which may
mean the assembly procedure will differ slightly. The following is a guideline for
installing the server into a rack with the rack rails provided in the rackmount kit.
You should also refer to the installation instructions that came with the rack unit
you are using.
Identifying the Sections of the Rack Rails
The optional rackmount kit (MCP-290-00001-00) includes two rack rail assemblies.
Each of these assemblies consist of two sections: an inner fi xed chassis rail that
secures to the chassis and an outer rack rail that secures directly to the rack itself.
The inner and outer rails must be detached from each other before installing.
To remove the inner chassis rail, pull it out as far as possible - you should hear a
"click" sound as a locking tab emerges from inside the rail assembly and locks the
inner rail. Depress the locking tab to pull the inner rail completely out. Do this for
both assemblies (one for each side).
Figure 2-1. Inner Fixed Chassis Rail
2-4
Chapter 2: Server Installation
Installing the Chassis Rails
You will need to remove the top bezel cover and the feet to add rack rails to the
chassis. First, remove the top and right covers (top and left covers when standing
as a tower chassis) by depressing the latch on the rear lip of the top (side if tower)
cover to release it - then push the cover off. Finally, unscrew the four feet and
remove them from the chassis (see Figure 2-2).
You can now attach rack rails to the top and bottom (now the sides) of the chassis.
First add the rack handles. Then position the inner chassis rail sections you just
removed along the side of the chassis making sure the screw holes line up. Note
that these two rails are left/right specifi c. Screw the rail securely to the side of the
chassis (see Figure 2-3). Repeat this procedure for the other rail on the other side
of the chassis. You will also need to attach the rail brackets when installing into a
telco rack.
Locking Tabs: The chassis rails have locking tabs that serve to lock the server into
place when installed and pushed fully into the rack, which is its normal position.
Figure 2-2. Preparing to Install the Chassis Rails
2-5
S
UPERSERVER 8044T-8R User's Manual
Figure 2-3. Installing the Rails to the Chassis
Installing the Rack Rails
Determine where you want to place the 8044T-8R in the rack. (See Rack and Server
Precautions in Section 2-3.) Position the fi xed rack rail/sliding rail guide assemblies
at the desired location in the rack, keeping the sliding rail guide facing the inside
of the rack. Screw the assembly securely to the rack using the brackets provided.
Attach the other assembly to the other side of the rack, making sure both are at
the exact same height and with the rail guides facing inward.
2-6
Chapter 2: Server Installation
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack. You should have two brackets in the rack
mount kit. Install these fi rst keeping in mind that they are left/right specifi c (marked
with "L" and "R"). Then, line up the rear of the chassis rails with the front of the
rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on
both sides (you may have to depress the locking tabs when inserting).
When the server has been pushed completely into the rack, you should hear the
locking tabs "click". Finish by inserting and tightening the thumbscrews that hold
the front of the server to the rack (see Figure 2-4).
Figure 2-4. Installing the Server into a Rack
2-7
S
UPERSERVER 8044T-8R User's Manual
2-5 Checking the Serverboard Setup
After setting up the the system, you will need to open the unit to make sure the
serverboard is properly installed and all the connections have been made.
1. Accessing the inside of the system (see Figure 2-5)
(If rack mounted, fi rst release the retention screws that secure the unit to the
rack. Grasp the two handles on either side and pull the unit straight out until it
locks (you will hear a "click").) There are two screws that secure the cover to
the chassis - remove these fi rst. Using the indentations on the side cover (see
Figure 2-5), push the cover to slide it off the chassis. You can then lift the cover
from the chassis to gain full access to the inside of the server.
2. Check the CPUs (processors)
You may have four processors already installed into the serverboard. Each
processor should have its own heatsink attached. See Chapter 5 for instructions
on processor installation.
3. Check the system memory
Your server may have come with system memory already installed. Make sure
all DIMMs are fully seated in their slots. For details on adding system memory,
refer to Chapter 5.
4. Installing add-on cards
If desired, you can install add-on cards to the system. See Chapter 5 for details
on installing PCI add-on cards.
5. Check all cable connections and airfl ow
Make sure all power and data cables are properly connected and not blocking
the chassis airfl ow. See Chapter 5 for details on cable connections.
2-8
Chapter 2: Server Installation
2-6 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the SCSI drives and
backplane have been properly installed and all connections have been made.
1. Accessing the drive bays
All drives can be accessed from the front of the server. For servicing the CD-
ROM, IDE hard drives and fl oppy drives, you will need to remove the top/left
chassis cover. The SCSI disk drives can be installed and removed from the front
of the chassis without removing any chassis covers.
2. Installing components into the 5.25" drive bays
To install components into the 5.25" drive bays, you must fi rst remove the top/
left chassis cover as described in the previous section. Refer to Chapter 6 for
details.
3. Installing CD-ROM and fl oppy disk drives
Refer to Chapter 6 if you need to install a CD-ROM and/or fl oppy disk drive to
the system.
4. Check the SCSI disk drives
Depending upon your system's confi guration, your system may have one or
more drives already installed. If you need to install SCSI drives, please refer to
Chapter 6.
5. Check the airfl ow
Airfl ow is provided by three 9-cm hot-swap chassis fans working in conjunction
with three 8-cm exhaust fans, which are located at the rear of the chassis. The
system component layout was carefully designed to promote suffi cient airfl ow
through the chassis. Also note that all power and data cables have been routed
in such a way that they do not block the airfl ow generated by the fans. Keep
this in mind when you reroute them after working on the system.
6. Supplying power to the system
The last thing you must do is to provide input power to the system. Plug the
power cords from the power supply modules into a high-quality power strip that
offers protection from electrical noise and power surges. It is recommended that
you use an uninterruptible power supply (UPS). Finally, depress the power on
button on the front of the chassis.
2-9
S
UPERSERVER 8044T-8R User's Manual
Figure 2-5. Accessing the Inside of the System
2-10
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the SCSI drive
carriers to keep you constantly informed of the overall status of the system as well
as the activity and health of specifi c components. There are also two buttons on
the chassis control panel. This chapter explains the meanings of all LED indica-
tors and the appropriate response you may need to take.
3-2 Control Panel Buttons
There are two push-buttons located on the front of the chassis. These are (in
order from left to right) a reset button and a power on/off button.
Reset:
Power: The main power switch is used to apply or remove power from the
power supply to the server system. Turning off system power with this button
removes the main power but keeps standby power supplied to the system.
Use the reset switch to reboot the system.
3-1
8044T-8R User's Manual
3-3 Control Panel LEDs
The control panel located on the front of the SC748TS-R1200P chassis has fi ve
LEDs. These LEDs provide you with critical information related to different parts
of the system. This section explains what each LED indicates when illuminated
and any corrective action you may need to take.
Power Fail: Indicates a power supply module has failed. This should be
accompanied by an audible alarm. A backup power supply module will take the
load and keep the system running but the failed module will need to be replaced.
Refer to Chapter 6 for details on replacing failed power supply modules. This LED
should be off when the system is operating normally.
Overheat/Fan Fail: When this LED fl ashes it indicates a fan failure. When
on continuously (on and not fl ashing) it indicates an overheat condition, which
may be caused by cables obstructing the airfl ow in the system or the ambient
room temperature being too warm. Check the routing of the cables and make
sure all fans are present and operating normally. You should also check to make
sure that the chassis covers are installed. Finally, verify that the heatsinks are
installed properly (see Chapter 5). This LED will remain fl ashing or on as long as
the overheat condition exists.
2
NIC2: Indicates network activity on LAN2 when fl ashing .
1
NIC1: Indicates network activity on LAN1 when fl ashing.
3-2
Chapter 3: System Interface
HDD: Indicates IDE channel activity. On the 8044T-8R, this light indicates
SCSI and/or CD-ROM drive activity when fl ashing.
Power: Indicates power is being supplied to the system's power supply
units. This LED should normally be illuminated when the system is operating.
3-4 Drive Carrier LEDs
SCSI Drives
Each SCSI drive carrier has two LEDs.
Green: When illuminated, the green LED on the front of the SCSI drive car-
rier indicates drive activity. A connection to the SCSI SCA backplane enables this
LED to blink on and off when that particular drive is being accessed.
Red: The SAF-TE compliant backplane activates the red LED to indicate a
drive failure. If one of the SCSI drives fail, you should be notifi ed by your system
management software. Please refer to Chapter 6 for instructions on replacing failed
SCSI drives.