Supermicro Supero A+ SERVER 1042G-TF User Manual

SUPER
®
USER’S MANUAL
Revision 1.0d
A+ SERVER 1042G-TF
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTW ARE, OR DA TA ST ORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0d Release Date: 14 July, 2011
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2011 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the A+ SERVER 1042G-TF. Installation and maintenance should be performed by experienced technicians only.
The A+ SERVER 1042G-TF is a 1U rackmount server based on the SC818TS-1400LPBP server chassis and the Super H8QGi+-F serverboards.
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the server system and describes the main features of the Super H8QGi+-F serverboard and the SC818TS-1400LPBP chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the A+ SER VER 1042G-TF into a rack and check out the server confi guration prior to powering up the system. If your server was ordered without the processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer to this chapter for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the A+ SERVER 1042G-TF.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the H8QGi+-F serverboard, including the locations and functions of connectors, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi guring the serverboard.
iii
Preface
A+ SERVER 1042G-TF User's Manual
iv
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC818TS-1400LPBP 1U rackmount server chassis. You should follow the procedures given in this chapter when installing, removing or reconfi guring SATA or peripheral drives and when replacing system power supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes Appendix B: Installing Windows Appendix C: System Specifi cations
v
Preface
Notes
vi
A+ SERVER 1042G-TF User's Manual
Table of Contents
Chapter 1 Introduction
1-1 Overview .........................................................................................................1-1
1-2 Serverboard Features .....................................................................................1-2
Processors ......................................................................................................1-2
Memory ...........................................................................................................1-2
Serial ATA ........................................................................................................ 1-2
PCI Expansion Slots .......................................................................................1-2
Ethernet Ports ................................................................................................. 1-2
Onboard Controllers/Ports .............................................................................. 1-2
Graphics Controller ......................................................................................... 1-3
Other Features ................................................................................................1-3
1-3 Server Chassis Features ................................................................................ 1-4
System Power ................................................................................................. 1-4
SATA Subsystem ............................................................................................. 1-4
Front Control Panel ......................................................................................... 1-4
Cooling System ...............................................................................................1-4
1-4 Contacting Supermicro ....................................................................................1-5
Chapter 2 Server Installation
2-1 Overview .........................................................................................................2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup ......................................................................................... 2-1
Choosing a Setup Location .............................................................................2-1
Rack Precautions ............................................................................................ 2-2
Server Precautions ..........................................................................................2-2
Rack Mounting Considerations ....................................................................... 2-3
Ambient Operating Temperature ................................................................ 2-3
Reduced Airfl ow ......................................................................................... 2-3
Mechanical Loading ................................................................................... 2-3
Circuit Overloading ..................................................................................... 2-3
Reliable Ground ......................................................................................... 2-3
2-4 Installing the System into a Rack ...................................................................2-4
Identifying the Sections of the Rack Rails ...................................................... 2-4
Installing the Inner Rail Extensions ................................................................ 2-5
Assembling the Outer Rails ............................................................................2-6
Installing the Outer Rails onto the Rack ......................................................... 2-7
Installing the Server into a Telco Rack ........................................................... 2-9
vii
Table of Contents
2-5 Checking the Serverboard Setup ..................................................................2-10
2-6 Checking the Drive Bay Setup .......................................................................2-11
Chapter 3 System Interface
3-1 Overview .........................................................................................................3-1
3-2 Control Panel Buttons ..................................................................................... 3-1
Reset ...............................................................................................................3-1
Power ..............................................................................................................3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
NIC2 ................................................................................................................3-2
NIC1 ................................................................................................................3-2
HDD ................................................................................................................. 3-2
Power ..............................................................................................................3-2
3-4 SATA Drive Carrier LEDs ................................................................................ 3-3
Chapter 4 System Safety
4-1 Electrical Safety Precautions ..........................................................................4-1
4-2 General Safety Precautions ............................................................................ 4-2
4-3 ESD Precautions ............................................................................................. 4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5 Advanced Serverboard Setup
5-1 Handling the Serverboard ............................................................................... 5-1
Precautions .....................................................................................................5-1
Unpacking .......................................................................................................5-2
5-2 I/O Port and Control Panel Connections ........................................................5-2
Front Control Panel ......................................................................................... 5-3
5-3 Processor and Heatsink Installation................................................................5-3
Installing a Passive CPU Heatsink .................................................................5-6
Removing the Heatsink ................................................................................... 5-6
5-4 Installing Memory ............................................................................................5-7
DIMM Module Population Confi guration .................................................... 5-9
5-5 PCI Expansion Cards ....................................................................................5-10
5-6 Serverboard Details .......................................................................................5-11
H8QGi+-F Quick Reference .......................................................................... 5-12
5-7 Connector Defi nitions ................................................................................... 5-13
5-8 Jumper Settings ............................................................................................ 5-19
Explanation of Jumpers ................................................................................ 5-19
5-9 Onboard Indicators ........................................................................................5-21
5-10 SAS and SATA Drive Connections ............................................................... 5-22
5-11 Enabling SATA RAID ..................................................................................... 5-23
viii
A+ SERVER 1042G-TF User's Manual
Serial ATA (SATA).......................................................................................... 5-23
Installing the OS/SATA Driver .......................................................................5-23
Building a Driver Diskette .........................................................................5-23
Enabling SATA RAID in the BIOS ................................................................. 5-24
Using the Adaptec RAID Utility ..................................................................... 5-25
Installing the RAID Driver During OS Installation .........................................5-25
5-12 Installing Drivers ............................................................................................5-26
Supero Doctor III ........................................................................................... 5-27
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices ..................................................................................6-1
Precautions .....................................................................................................6-1
6-2 Control Panel ..................................................................................................6-2
6-3 System Cooling ...............................................................................................6-2
System Fan Failure ......................................................................................... 6-3
6-4 Drive Bay Installation/Removal ....................................................................... 6-4
Accessing the Drive Bays ............................................................................... 6-4
Peripheral Drive Installation ............................................................................ 6-7
6-5 Installing the Air Shroud ..................................................................................6-8
Checking the Air Flow ..................................................................................... 6-8
6-6 Power Supply ................................................................................................6-10
Power Supply Failure .................................................................................... 6-10
Chapter 7 BIOS
7-1 Introduction ......................................................................................................7-1
7-2 Main Menu ...................................................................................................... 7-2
7-3 Advanced Settings Menu ................................................................................ 7-2
7-4 Security Settings Menu ................................................................................. 7-12
7-5 Boot Settings Menu .......................................................................................7-13
7-6 Exit Menu ...................................................................................................... 7-14
Appendix A BIOS Error Beep Codes Appendix B Installing Windows
B-1 Installing Windows to a RAID System ............................................................B-1
B-2 Installing Windows to a Non-RAID System .................................................... B-2
Appendix C System Specifi cations
Chapter 1
Introduction
1-1 Overview
The A+ SERVER 1042G-TF is a 1U server comprised of the SC818TS-1400LPBP chassis and one H8QGi+-F serverboards. Please refer to our web site for information on operating systems that have been certifi ed for use with the server (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components may have been included with the system, as listed below.
One (1) mini-SATA to USB adapter for slim DVD (CDM-USATA-G-O-P)
One (1) slim SATA DVD kit (MCP-220-81502-0N)
Four (4) 1U passive CPU heatsinks for AMD Socket G34 (SNK-P0042P)
Six 4-cm counter-rotating fans (FAN-0111L4)
SATA Accessories: Three (3) hard drive carriers (MCP-220-00001-01) One (1) internal HDD backplane (BPN-SAS-818TQ) One (1) 40-cm 8pin to 8pin ribbon cable with tube SGPIO cable (CBL-0157L) Three (3) 48CM SATA round cable sets (CBL-0206L) One (1) 70-cm, internal USB cable for slim USB DVD-ROM (CBL-0341L)
One (1) PCI Express x16 riser card (RSC-RR1U-E16)
Rackmount kit (MCP-290-00062-0N)
One CD containing drivers and utilities
Chapter 1: Introduction
1-1
1-2
A+ SERVER 1042G-TF User's Manual
1-2 Serverboard Features
At the heart of the A+ SERVER 1042G-TF is one H8QGi+-F quad processor serverboard, which is based on the AMD SR5690/SP5100 chipset.
Below are the main features of the serverboards.
Processors
The H8QGi+-F supports four AMD Opteron 6100 series (AMD Socket G34) processors. Please refer to our web site for a complete listing of supported processors (www.supermicro.com).
Memory
The H8QGi+-F has thirty-two (32) single/dual/tri/quad channel DIMM slots supporting up to 128 GB of ECC/Non-ECC UDIMM or up to 512 GB of ECC RDIMM DDR3-1333/1066/800 SDRAM. See Chapter 5 Section 6 for more details on installing memory into the system.
Serial ATA
The Sout h Br idge (SP5100) of the ch ipset in clu des a Se ria l ATA contr olle r for si x 3 Gb/s SATA drives. The hot-swappable SATA drives are connected to a backplane that provides power, bus termination and confi guration settings. R AID 0 a nd 1 are supported. Refer to t he su ppo r t ar ea of ou r web si te for p roc e dure s on set t ing u p RAID on your system.
PCI Expansion Slots
The H8QGi+-F board has one PCI Express 2.0 x16 slot.
Ethernet Ports
An Intel® network controller is integrated into each of the serverboards to support two Gigabit LAN ports (100/1000Base-T/1000BaseTX, RJ45 output).
Onboard Controllers/Ports
Onboard I/O backpanel ports on the serverboard include one COM port, a VGA port, two USB ports, a dedicated IPMI LAN port and two Gigabit LAN (NIC) ports.
Chapter 1: Introduction
1-3
Graphics Controller
The H8QGi+-F features an integrated Matrox G200eW graphics chip, which includes 16 MB of DDR2 memory.
Other Features
Other onboard features that promote system health include voltage monitors, auto­switching voltage regulators, chassis and CPU overheat sensors, virus protection and BIOS rescue.
Figure 1-1. AMD SR5690/SP5100 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
G34-SOCKET #3
8x DIMM
8x DIMM
FWH
Keyboard/
Mouse
LPC SIO
W83527DHG-P
G34-SOCKET #2
VRM
G34-SOCKET #4
AMD
SR5690
#1
PCIE (X16)
H/W_MONITOR
W83795
HT Link
LPC BUS
9_FAN_CONN.
VRM
6x PORTS SATA_CONN
SATA
HT Link
HT Link
VRM VRM
HT Link
16/16-1GHz
HT Link
HT Link
8x DIMM
DDR3-1333/1066
USB
USB PORT
(0-5, 6)
SLOT#4
PCIE_(X16)
Intel
82576
PCIE (x4)
AMD
SP5100
Winbond
WPCM450
VGA
DDR3-1333/1066
DDR3-1333/1066
HT Link
CH A0,A1 B0,B1 C0,C1 D0,D1
8x DIMM
DDR3-1333/1066
CH A0,A1 B0,B1 C0,C1 D0,D1
G34-SOCKET #1
1-4
A+ SERVER 1042G-TF User's Manual
1-3 Server Chassis Features
System Power
The SC818TS-1400LPBP features a Gold Level 1400W high-effi ciency power supply. The AC power cord should be removed from the system before servicing or replacing the power supply. See Chapter 6 for details.
SATA Subsystem
The SC818TS-1400LPBP chassis i ncludes thre e 3.5" drive bays, wh ich may be used to hou se hot- swappab le SATA dri ves. R AID 0 a nd 1 are sup por ted.
Front Control Panel
The control panel provides a system monitoring and control interface. LEDs indicate system power, HDD activity, network activity, system overheat and power supply failure. A main power button and a system reset button are also included.
Cooling System
The SC818TS-1400LPBP has an innovative cooling design that includes four 4-cm counter-rotating PWM (Pulse Width Modulated) fans located in the middle section of the chassis. The power supply module also includes a cooling fan. All chassis and power supply fans operate continuously. An air shroud channels the airfl ow from the system fans to effi ciently cool the processors and memory. See note on the following page regarding fan control.
Chapter 1: Introduction
1-5
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support) Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd.
Chung-Ho 235, Taipei County
Taiwan, R.O.C. Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Web Site: www.supermicro.com.tw Technical Support: Email: support@supermicro.com.tw Tel: +886-(2) 8226-5990
1-6
A+ SERVER 1042G-TF User's Manual
Notes
Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your A+ SERVER up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a serverboard, processors, system memory etc., please turn to the chapter or section noted in each step for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the system was shipped in and note if it was damaged in any way. If the server itself shows damage you should fi le a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the server. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fi elds are generated. You will also need it placed near a grounded power outlet. Read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the server was shipped in should include two sets of rail assemblies, two rail mounting brackets and the mounting screws you will need to install the system into the rack. Follow the steps in the order given to complete the installation process in a minimum amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow.
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for suffi cient airfl ow and ease in servicing.This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like).
2-2
A+ SERVER 1042G-TF User's Manual
!
!
Warnings and Precautions!
This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to the fl oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack. In multiple rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the rack.
You should extend only one component at a time - extending two or more si- multaneously may cause the rack to become unstable.
Rack-mounted equipment should not be used as a shelf or work space.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
Determine the placement of each component in the rack before you install the rails.
Install the heaviest server components on the bottom of the rack fi rst, and then work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from power surges, voltage spikes and to keep your system operating in case of a power failure.
Allow the hot plug SATA drives and power supply modules to cool before touch- ing them.
Always keep the rack's front door and all panels and components on the servers closed when not servicing to maintain proper cooling.
Chapter 2: Server Installation
2-3
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).
2-4
A+ SERVER 1042G-TF User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the SC818TS chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.
Note: This rail will t a rack between 26" and 33.5" deep.
Identifying the Sections of the Rack Rails
The chassis package includes two rack rail assemblies in the rack mounting kit. Each assembly consists of two sections: an inner fi xed chassis rail that secures directly to the server chassis and an outer fi xed rack rail that secures directly to the rack itself.
Figure 2-1. Identifying the Sections of the Rack Rails
Inner Rail
Extension:
attach to the
chassis
Outer Rails:
slide together,
then attach to
the front and rear
brackets
Inner Rail
(preattached to the
chassis)
Front and Rear
Brackets: attach
to the rack
Chapter 2: Server Installation
2-5
Figure 2-2. Installing the Inner Rails
Installing the Inner Rail Extensions
The SC818TS chassis includes a set of inner rack rails in two sections: inner rails (A) and inner rail extensions (B). The inner rails are preattached and do not interfere with normal use of the chassis if you decide not to install to a server rack. Attaching the inner rail extensions to to the inner rails stabilizes the chassis within the rack.
Installing the Inner Rail Extensions
Place the inner rail extensions (B) over the preattached inner rails (A) which 1. are attached to the side of the chassis. Align the hooks of the inner rail with the rail extension holes. Make sure the extension faces "outward" just like the inner rail.
Slide the extension toward the front of the chassis.2.
Secure the chassis with screws as illustrated.3.
Repeat steps 1-3 for the other inner rail extension.4.
1
1
1
2
1
3
2-6
A+ SERVER 1042G-TF User's Manual
Figure 2-3. Assembling the Outer Rails
Assembling the Outer Rails
Each outer rail is in two sections that must be assembled before mounting on to the rack.
Assembling the Outer Rails
Identify the left and right outer rails by examining the ends, which bend 1. outward.
Slide the front section of the outer rail (A), into the rear section of the outer 2. rail (B).
Secure to the
front of the rack
Secure to the
rear of the rack
Slide outer rails
together
Outer rail assembled
Assembling the sections
of the outer rail
1
A
1
B
Chapter 2: Server Installation
2-7
Figure 2-4. Installing the Outer Rails to the Rack
Installing the Outer Rails onto the Rack
Outer Rail Installation
Adjust the outer rails to the proper length so that the outer rail fi ts snugly 1. within the rack.
Align the holes on the front of the outer rail, with the holes on the front of the 2. rack (C) and secure with the screws provided.
Align the holes on the rear of the outer rail to the holes on the rack (D) and 3. secure with the screws provided.
Repeat the procedure with the second outer rail assembly.4.
1
C
1
D
2-8
A+ SERVER 1042G-TF User's Manual
Figure 2-5. Installing the Server into a Rack
Installing the Chassis into a Rack (Figure 2-5)
Confi rm that chassis includes the inner rails and rail extensions . Also, confi rm 1. that the outer rails are installed on the rack.
Line chassis rails with the front of the rack rails.2.
Slide the chassis rails into the rack rails, keeping the pressure even on both 3. sides (you may have to depress the locking tabs when inserting). When the server has been pushed completely into the rack, you should hear the locking tabs "click".
(Optional) Insert and tightening the thumbscrews that hold the front of the 4. server to the rack.
Chapter 2: Server Installation
2-9
Installing the Server into a Telco Rack
Optional brackets (p/n MCP-290-00016-0N) are needed to install the server to a telco (open type) rack.
To install the server into a Telco type rack, use the two L-shaped brackets on either side of the chassis (four total). First, determine how far follow the server will extend out the front of the rack. Larger chassis should be positioned to balance the weight between front and back. If a bezel is included on your server, remove it. Then attach the two front brackets to each side of the chassis, then the two rear brackets positioned with just enough space to accommodate the width of the telco rack. Finish by sliding the chassis into the rack and tightening the brackets to the rack.
Figure 2-6. Installing the Server into a Telco Rack
2-10
A+ SERVER 1042G-TF User's Manual
2-5 Checking the Serverboard Setup
After you install the server in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made.
Removing the Chassis Cover (Figure 2-7)
Remove the three screws securing the top cover to the chassis.1.
Press both of the release tabs at the same time to release the cover 2.
Slide the cover toward the rear of the chassis.3.
Lift the cover up and off of the chassis.4.
Figure 2-7: Removing the Chassis Cover
Warning: Except for short periods of time, do NOT operate the server
without the cover in place. The chassis cover must be in place to allow proper airfl ow and prevent overheating.
!
1
1
1
1
1
3
1
4
1
2
1
2
1
1
Chapter 2: Server Installation
2-11
Checking the Components
You may have processors already installed to the serverboard. Each 1. processor needs its own heatsink. See Chapter 5 for instructions on processor and heatsink installation.
Your server system may have come with system memory already installed. 2. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.
If desired, you can install add-on cards to the system. See Chapter 5 for 3. details on installing PCI add-on cards.
Make sure all power and data cables are properly connected and not blocking 4. the chassis airfl ow. See Chapter 5 for details on cable connections. Also, check the air seals for damage. The air seals are located under the blower fan and beneath the frame cross section that separates the drive bay area from the serverboard area of the chassis.
2-6 Checking the Drive Bay Setup
Next, you should check to make sure the hard drives have been properly installed and all connections have been made.
Checking the Drives
You can add or remove hard drives from the drive carriers without having to 1. remove the top chassis cover.
If you need to remove or install hard drives, please refer to Chapter 6.2.
Checking the Airfl ow
Airfl ow is provided by 4-cm counter-rotating fans. The system component 1. layout was carefully designed to direct suffi cient cooling airfl ow to the components that generate the most heat.
Note that all power and data cables have been routed in such a way that they 2. do not block the airfl ow generated by the fans.
2-12
A+ SERVER 1042G-TF User's Manual
Providing Power
The last thing you must do is to provide input power to the system. Plug the 1. power cord from the power supply unit into a high-quality power strip that offers protection from electrical noise and power surges. It is recommended that you use an uninterruptible power supply (UPS).
Finish by depressing the power button on the chassis control panel.2.
Chapter 3: System Interface
3-1
Power
The main power button is used to apply or remove power from the power supply to the server system. Turning off system power with this button removes the main power but keeps standby power supplied to the system.
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi c components. There are also two buttons on the chassis control panel and an on/off switch on the power supply. This chapter explains the meanings of all LED indicators and the appropriate response you may need to take.
3-2 Control Panel Buttons
There are two push-buttons located on the front of the chassis: a reset button and a power on/off button.
Reset
Use the reset button to reboot the system.
3-2
A+ SERVER 1042G-TF User's Manual
2
1
NIC2
Indicates network activity on LAN2 when fl ashing .
3-3 Control Panel LEDs
The control panel located on the front of the SC818GTQ chassis has fi ve LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
NIC1
Indicates network activity on LAN1 when fl ashing .
HDD
This light i ndic ates SATA and/or DV D- ROM d rive ac tivit y when fl ashing.
Power
Indic ates power is bein g supplied to the sy stem's power supply u nits. This LED should normally be illuminated when the system is operating.
Chapter 3: System Interface
3-3
3-4 SATA Drive Carrier LEDs
Green: Each Ser i al ATA drive carr ie r ha s a gr ee n LED. Wh en i ll umi nate d, t hi s
green LED (on th e front of the SATA dr ive carrie r) in dicates drive ac tivity. A conne cti on to th e SATA back plane e nable s this LE D to blink o n and of f whe n that particular drive is being accessed. Please refer to Chapter 6 for instructions on replacing failed SATA drives.
Red:
The red LED to indicate an SATA drive failure. If one of the SATA drives
fail, you should be notifi ed by your system management software. Please refer to Chapter 6 for instructions on replacing failed SATA drives.
Loading...