The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license.
Any use or reproduction of this product is not allowed, except as expressly permitted by the terms
of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the manufacturer’s instruction manual, may cause harmful interference
with radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to the
State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0a
Release Date: February 20, 2013
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the SuperServer 6016T-6F. Installation and maintainance should be performed by experienced technicians only.
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the
server system and describes the main features of the X8DT6-F serverboard and
the SC815TQ-563CB chassis.
Preface
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 6016T-6F into
a rack and check out the server confi guration prior to powering up the system. If
your server was ordered without processor and memory components, this chapter
will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 6016T-6F.
iii
SUPERSERVER 6016T-6F User's Manual
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X8DT6-F serverboard, including the
locations and functions of connections, headers and jumpers. Refer to this chapter
when adding or removing processors or main memory and when reconfi guring the
serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC815TQ-563CB server chassis.
You should follow the procedures given in this chapter when installing, removing
or reconfi guring SAS/SATA or peripheral drives and when replacing system power
supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility.
Appendix A BIOS Error Beep Codes
Appendix B Installing Windows
Appendix C System Specifi cations
viii
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The SuperServer 6016T-6F is a high-end server comprised of two main subsystems: the SC815TQ-563CB 1U server chassis and the X8DT6-F dual processor
serverboard. Please refer to our web site for information on operating systems that
have been certifi ed for use with the system (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have
been included with the 6016T-6F, as listed below:
• Two passive CPU heatsinks (SNK-P0037P)
• One slim DVD-ROM drive (DVM-TEAC-DVD-SBT)
• Four counter-rotating fans (FAN-0086L4)
• One air shroud (MCP-310-18002-0N)
• One riser card for PCI-E x8 expansion card (CSE-RR1U-E8)
• SAS/SATA Accessories
One SAS/SATA backplane (BPN-SAS-815TQ)
One iPass to 4-connector SATA cable (CBL-0176L-01)
Four drive carriers (MCP-220-00024-0B)
• One rackmount kit (CSE-PT51)
• One CD containing drivers and utilities
• SuperServer 6016T-6F User's Manual
Note: a complete list of safety warnings is provided on the Supermicro web site at
The SuperServer 6016T-6F is built around the X8DT6-F, a dual processor
serverboard based on the Intel IOH-36D + ICH10R chipset and designed to provide
maximum performance. Below are the main features of the X8DT6-F. (See Figure
1-1 for a block diagram of the chipset).
Processors
The X8DT6-F supports single or dual Intel® Xeon 5600/5500 Series processors.
Please refer to the serverboard description pages on our web site for a complete
listing of supported processors (www.supermicro.com).
Memory
The X8DT6-F has twelve DIMM slots that can support up to 192 GB of ECC registered DDR3-1333/1066/800 or up to 48 GB of ECC unbuffered DDR3-1333/1066/800
SDRAM. Memory mirroring is supported. See Chapter 5 for details.
SAS
An LSI 2008 SAS controller is integrated into the serverboard to support eight SAS2
ports, which are RAID 0, 1 and 10 capable. The SAS drives are hot-swappable
units. SAS RAID 5 is also supported with the AOC-SAS2-RAID5-KEY (optional)
installed on the serverboard.
Note: The operati ng system yo u use must h ave R AID su ppor t to e nable t he hotswap capability and RAI D function of the SAS drives.
Serial ATA
A Serial ATA controller is integrated into the ICH10R (South Bridge) portion of the
IOH-36D chipset to provide a six-port 3 Gb/s SATA subsystem, which is RAID 0, 1,
10 and 5 supported. The SATA drives are hot-swappable units.
Note: The operati ng system yo u use must h ave R AID su ppor t to e nable t he hotswap cap abilit y and RA ID func tion of the S ATA drive s. RAI D 5 require s the use
of an iButton.
PCI Expansion Slots
The X8DT6-F has three PCI-Express 2.0 x8 slots, one PCI-Express 2.0 x4 slot and
one PCI-Express x4 slot. For the 6016T-6F server, one PCI-Express x8 add-on card
is supported with the use of a riser card (included).
1-2
Chapter 1: Introduction
Onboard Controllers/Ports
A fl oppy drive connector is included on the serverboard. The color-coded I/O ports
include one COM port (an additional COM header is located on the serverboard),
a VGA (monitor) port, two USB 2.0 ports (additional USB headers are included on
the serverboard), PS/2 mouse and keyboard ports, two gigabit Ethernet ports and
a dedicated IPMI LAN port.
Graphics Controller
The X8DT6-F features an integrated Matrox G200eW video controller. The G200eW
is a 2D/3D/video accelerator chip with a 128-bit core.
Other Features
Other onboard features that promote system health include onboard voltage monitors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU
overheat sensors, virus protection and BIOS rescue.
1-3 Server Chassis Features
The following is a general outline of the main features of the SC815TQ-563CB
server chassis. Details on the chassis and on servicing procedures can be found
in Chapter 6.
System Power
The SC815TQ-563CB features a single 560W power supply module. The system
must be shut down when replacing or removing this power supply module.
SAS/SATA Subsystem
The SC815TQ-563CB supports up to four SAS or SATA drives. These drives are
hot-swappable units and are connected to a backplane that provides power and
control.
Note: The operating system you use must have RAID support to enable the hotswap capability of the SAS/SATA drives.
Front Control Panel
The control panel on the SuperServer 6016T-6F provides you with system monitoring and control. LEDs indicate system power, HDD activity, network activity (two)
and overheat/fan fail. A main power button and a system reset button are also
included.
1-3
SUPERSERVER 6016T-6F User's Manual
I/O Backplane
The SC815TQ-563CB is an extended ATX form factor chassis that is designed to
be used in a 1U rackmount confi guration. The I/O backplane provides one COM
port, a VGA port, two USB 2.0 ports, PS/2 mouse and keyboard ports, two gigabit
Ethernet ports and one dedicated IPMI LAN port.
Cooling System
The SC815TQ-563CB chassis has an innovative cooling design that features four
sets of 4-cm counter-rotating fans located in the middle section of the chassis. There
is a "Fan Speed Control Mode" setting in BIOS that allows chassis fan speed to
be determined by system temperature. The power supply module also includes a
cooling fan.
1-4
Chapter 1: Introduction
Figure 1-1. Intel IOH-36D/ICH10R Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
#4
x16 Slot
PCI-E x16/8
Ports#0~3
Ports#4~7
#1-2
#1-1
DDR3
LAN#2
82576EB
SAS
LSI 2008
B3
Option
LAN#1
82576EB
BMC WPCM450
#1-6
#1-5
#1-4
#1-3
800/1066/1333
(Optional)
Port
#7
Port
PCI-E x4
#8
PCI-E x4
#6
PCI-E x8
#5
PCI-E x8
PCI-E x8
SPEC
#2
PCI-33
#3
PCI-33
#1
VRDVRD
6 PHASE6 PHASE
PCI-E x16
PCI-E x4
PCI-E x8
PCI 33MHz
CPU #2
PCI-E x8
LANE 1/2/3/4
LANE5
LANE6
QPI
Ports
Ports
#1-2
Ports
#5-6
SPI
#7-10
Ports
QPI
Intel
IOH-36D
#3-4
Port
DMI
Intel ICH10R
QPI
#0
ESI
W83627
CPU #1
PCIE x4
SIO
HG
3.0 Gb/S
USB 2.0
LPC
TPM
#0-4
#0-3
#0-2
#0-1
DDR3
800/1066/1333
SATA
USB
#0-5
#0-6
1-5
MS
KB
COM1
COM2
SUPERSERVER 6016T-6F User's Manual
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel:+1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site:
This chapter provides a quick setup checklist to get your SuperServer 6016T-6F up
and running. Following these steps in the order given should enable you to have
the system operational within a minimum amount of time. This quick setup assumes
that your system has come to you with the processors and memory preinstalled. If
your system is not already fully integrated with a serverboard, processors, system
memory etc., please turn to the chapter or section noted in each step for details on
installing specifi c components.
2-2 Unpacking the System
You should inspect the box the SuperServer 6016T-6F was shipped in and note
if it was damaged in any way. If the server itself shows damage you should fi le a
damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the 6016T-6F. It should
be situated in a clean, dust-free area that is well ventilated. Avoid areas where
heat, electrical noise and electromagnetic fi elds are generated. You will also need
it placed near a grounded power outlet. Be sure to read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 6016T-6F was shipped in should include two sets of rail
assemblies, two rail mounting brackets and the mounting screws you will need to
install the system into the rack. Follow the steps in the order given to complete
the installation process in a minimum amount of time. Please read this section in
its entirety before you begin the installation procedure outlined in the sections that
follow.
2-1
SUPERSERVER 6016T-6F User's Manual
Choosing a Setup Location
• Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for suffi cient airfl ow and ease in servicing.This product is for
installation only in a Restricted Access Location (dedicated equipment rooms,
service closets and the like).
• This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
2-4 Warnings and Precautions
Rack Precautions
• Ensure that the leveling jacks on the bottom of the rack are fully extended to
the fl oor with the full weight of the rack resting on them.
• In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
• Always make sure the rack is stable before extending a component from the
rack.
• You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
Server Precautions
• Review the electrical and general safety precautions in Chapter 4.
• Determine the placement of each component in the rack before you install the
rails.
• Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
• Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
2-2
Chapter 2: Server Installation
• Allow the hot plug SAS/SATA drives and power supply modules to cool before
touching them.
• Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
2-3
SUPERSERVER 6016T-6F User's Manual
2-5 Installing the System into a Rack
This section provides information on installing the 6016T-6F into a rack unit with
the rack rails provided. If the system has already been mounted into a rack, you
can skip ahead to Sections 2-5 and 2-6.
There are a variety of rack units on the market, which may mean the assembly
procedure will differ slightly. Y ou should also refer to the installation instructions that
came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies in the rack mounting kit. Each
assembly consists of two sections: an inner fi xed chassis rail that secures directly
to the server chassis and an outer fi xed rack rail that secures directly to the rack
itself (see Figure 2-1). Two pairs of short brackets to be used on the front side of
the outer rails are also included.
Installing the Inner Rails
Both the left and right side inner rails have been pre-attached to the chassis. Proceed to the next step.
Figure 2-1. Identifying the Sections of the Rack Rails
(right side rail shown)
2-4
Chapter 2: Server Installation
Installing the Outer Rails
Begin by measuring the distance from the front rail to the rear rail of the rack. Attach
a short bracket to the front side of the right outer rail and a long bracket to the rear
side of the right outer rail. Adjust both the short and long brackets to the proper
distance so that the rail can fi t snugly into the rack. Secure the short bracket to the
front side of the outer rail with two screws and the long bracket to the rear side of
the outer rail with three screws. Repeat these steps for the left outer rail.
Locking Tabs: Both chassis rails have a locking tab, which serves two functions.
The fi rst is to lock the server into place when installed and pushed fully into the
rack, which is its normal position. Secondly, these tabs also lock the server in place
when fully extended from the rack. This prevents the server from coming completely
out of the rack when you pull it out for servicing.
Figure 2-2. Installing the Rack Rails
Warning! To prevent bodily injury when mounting or servicing this unit in a
rack, you must take special precautions to ensure that the system remains
stable. The following guidelines are provided to ensure your safety:
• This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
• When mounting this unit in a partially fi lled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
2-5
SUPERSERVER 6016T-6F User's Manual
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack. Do this by lining up the rear of the chassis
rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping
the pressure even on both sides (you may have to depress the locking tabs when
inserting). See Figure 2-3.
When the server has been pushed completely into the rack, you should hear the
locking tabs "click".
Figure 2-3. Installing the Server into a Rack
Warning: do not pick up the server with the front handles. They are de-
signed to pull the system from a rack only.
2-6
Chapter 2: Server Installation
Installing the Server into a Telco Rack
To install the 6016T-6F into a Telco type rack, use two L-shaped brackets on either
side of the chassis (four total). First, determine how far follow the server will extend
out the front of the rack. Larger chassis should be positioned to balance the weight
between front and back. If a bezel is included on your server, remove it. Then attach the two front brackets to each side of the chassis, then the two rear brackets
positioned with just enough space to accommodate the width of the telco rack. Finish
by sliding the chassis into the rack and tightening the brackets to the rack.
Figure 2-4. Installing the Server into a Telco Rack
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the fl oor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.
2-7
SUPERSERVER 6016T-6F User's Manual
2-6 Checking the Serverboard Setup
After you install the 6016T-6F in the rack, you will need to open the top cover to
make sure the serverboard is properly installed and all the connections have been
made.
Accessing the Inside of the System
1. First, grasp the two handles on either side and pull the system straight out
until it locks (you will hear a "click").
2. Depress the two buttons on the top of the chassis to release the top cover
(1).
3. Push the cover away from you (toward the rear of the chassis) until it stops
(2). You can then lift the top cover from the chassis to gain full access to the
inside of the server. See Figure 2-5.
4. To remove the system from the rack completely, depress the locking tabs in
the chassis rails (push the right-side tab down and the left-side tab up) to
continue to pull the system out past the locked position.
Checking the Components
1. You may have one or two processors already installed in the serverboard.
Each processor needs its own heatsink. See Chapter 5 for instructions on
processor and heatsink installation.
2. Your server system may have come with system memory already installed.
Make sure all DIMMs are fully seated in their slots. For details on adding
system memory, refer to Chapter 5.
3. If desired, you can install add-on cards to the system. See Chapter 5 for
details on installing PCI add-on cards.
4. Make sure all power and data cables are properly connected and not blocking
the chassis airfl ow. See Chapter 5 for details on cable connections.
2-8
Chapter 2: Server Installation
Figure 2-5. Accessing the Inside of the System
2-7 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the SAS/SATA
drives and backplane have been properly installed and all connections have been
made.
Checking the Drives
1. All drives are accessable from the front of the server. The SAS/SATA disk
drives can be installed and removed from the front of the chassis without
removing the top chassis cover.
2. A slim DVD-ROM drive should be preinstalled in your server. For servicing
the DVD-ROM drive, you will need to remove the top chassis cover. Refer to
Chapter 6 if you need to reinstall a DVD-ROM drive to the system.
3. Depending upon your system's confi guration, your system may have one
or more drives already installed. If you need to install SAS or SATA drives,
please refer to Chapter 6.
2-9
SUPERSERVER 6016T-6F User's Manual
Checking the Airfl ow
1. Airfl ow is provided by four sets of 4-cm fans (each set of fans consists of
two fans that are mounted back to back). The system component layout was
carefully designed to direct suffi cient cooling airfl ow to the components that
generate the most heat.
2. Note that all power and data cables have been routed in such a way that they
do not block the airfl ow generated by the fans.
Providing Power
1. The last thing you must do is to provide input power to the system. Plug the
power cords from the power supply modules into a high-quality power strip
that offers protection from electrical noise and power surges.
2. It is recommended that you use an uninterruptible power supply (UPS).
2-10
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the drive carriers to keep you constantly informed of the overall status of the system as well
as the activity and health of specifi c components. There are also two buttons on
the chassis control panel and an on/off switch on the power supply. This chapter
explains the meanings of all LED indicators and the appropriate response you may
need to take.
3-2 Control Panel Buttons
There are two push-buttons located on the front of the chassis: a reset button and
a power on/off button.
Reset
Use the reset button to reboot the system.
Power
The main power button is used to apply or remove power from the power supply
to the server system. Turning off system power with this button removes the main
power but keeps standby power supplied to the system.
3-1
SUPERSERVER 6016T-6F User's Manual
3-3 Control Panel LEDs
The co ntrol panel loc ated on the front o f the SC815TQ-563CB chassis ha s fi ve
LEDs. The se LEDs pr ovide you wi th crit ical in format ion relate d to dif ferent par ts
of the system . This section ex plains what each LED i ndicates when il luminated
and any co rrec tive ac tion yo u may need to t ake.
2
NIC2
Indicates network activity on LAN2 when fl ashing.
1
NIC1
Indicates network activity on LAN1 when fl ashing.
HDD
On the SuperServer 6016T-6F, this light indicates SAS/SATA and/or DVD-ROM
drive activity when fl ashing.
Power
Indicates power is being supplied to the system's power supply units. This LED
should normally be illuminated when the system is operating.
3-2
Chapter 3: System Interface
3-4 Hard Drive Carrier LEDs
Each hard drive carrier has two LEDs.
• Green: When illuminated, the green LED on the front of the drive carrier in-
dicates drive activity. A connection to the drive backplane enables this LED to
blink on and off when that particular drive is being accessed.
• Red: The red LED indicates two states. When blinking, it indicates the drive is
rebuilding. When solid, it indicates a drive failure. If a hard drive fails, you should
be notifi ed by your system management software. Please refer to Chapter 6 for
instructions on replacing failed hard drives.
3-3
SUPERSERVER 6016T-6F User's Manual
Notes
3-4
Chapter 4: Warning Statements for AC Systems
Chapter 4
Standardized Warning Statements for AC Systems
4-1 About Standardized Warning Statements
The following statements are industry standard warnings, provided to warn the user
of situations which have the potential for bodily injury. Should you have questions
or experience difficulty, contact Supermicro's Technical Support department
for assistance. Only certifi ed technicians should attempt to install or confi gure
components.
Read this appendix in its entirety before installing or confi guring components in the
Supermicro chassis.
These warnings may also be found on our web site at http://www.supermicro.com/
about/policies/safety_information.cfm.
Warning Defi nition
Warning!
This warning symbol means danger. You are in a situation that could cause bodily
injury. Before you work on any equipment, be aware of the hazards involved with
electrical circuitry and be familiar with standard practices for preventing accidents.
Warnung
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situation, die zu
Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den
Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung
vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen
Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten
Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
BEWAHREN SIE DIESE HINWEISE GUT AUF.
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes
de manipular cualquier equipo, considere los riesgos de la corriente eléctrica y
familiarícese con los procedimientos estándar de prevención de accidentes. Al
fi nal de cada advertencia encontrará el número que le ayudará a encontrar el texto
traducido en el apartado de traducciones que acompaña a este dispositivo.
GUARDE ESTAS INSTRUCCIONES.
IMPORTANTES INFORMATIONS DE SÉCURITÉ
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une
situation pouvant entraîner des blessures ou des dommages corporels. Avant
de travailler sur un équipement, soyez conscient des dangers liés aux circuits
électriques et familiarisez-vous avec les procédures couramment utilisées pour
éviter les accidents. Pour prendre connaissance des traductions des avertissements
fi gurant dans les consignes de sécurité traduites qui accompagnent cet appareil,
référez-vous au numéro de l'instruction situé à la fi n de chaque avertissement.