Supermicro FatTwin F617H6-FTL+, FatTwin F617H6-FTPTL+, FatTwin F627G2-FTPT+, FatTwin F627G2-FT+, FatTwin F627G2-F73+ User Manual

...
®
SUPER
USER'S MANUAL
Revision 1.1a
FatTwin
F617H6-FTL+
F617H6-FTPTL+
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at
www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See
www.dtsc.ca.gov/hazardouswaste/perchlorate
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
Revision 1.1a Release Date: January 23, 2015
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2015 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
iii
Preface
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the FatTwin™ F617H6-FTL+/FTPTL+. Installation and maintainance should be performed by experienced technicians only .
The FatTwin F617H6-FTL+/FTPTL+ is a high-end server based on the F414IS-R1K62B 4U rackmount chassis and a dual processor X9DRFF-7G+/7TG+ serverboard. All models have four serverboard nodes each with an IPMI LAN port and twelve (12) 3.5" fi xed HDD drives and two (2) 2.5" optional fi xed HHD drives each per node. The F617H6-FTPTL+ server uses 10-Gigabit LAN ports whereas the F617H6-FTL+ server uses Gigabit LAN ports.
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the server system and describes the main features of the X9DRFF-7G+/7TG+ serverboards and the F414IS-R1K62B chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the FatTwin F617H6-FTL+/FTPTL+ into a rack and check out the server confi guration prior to powering up the system. If your server was ordered without processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the FatTwin F617H6-FTL+/FTPTL+.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X9DRFF-7G+/7TG+ serverboards, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi guring the serverboard.
FatTwin F617H6-FTL+/FTPTL+ User's Manual
iv
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the F414IS-R1K62B server chassis. You should follow the procedures given in this chapter when installing, removing or reconfi guring SATA or peripheral drives and when replacing system power supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes Appendix B: System Specifi cations
v
FatTwin F617H6-FTL+/FTPTL+ User's Manual
Notes
vi
Table of Contents
Chapter 1 Introduction
1-1 Overview .........................................................................................................1-1
1-2 Serverboard Features .....................................................................................1-2
Processors ......................................................................................................1-2
Memory ...........................................................................................................1-2
Onboard SAS .................................................................................................. 1-2
Onboard Serial ATA ........................................................................................1-3
PCI Expansion Slots ....................................................................................... 1-3
I/O Ports ..........................................................................................................1-3
Graphics Controller ......................................................................................... 1-3
Nuvoton WPCM450 Controller .......................................................................1-3
WPCM450R DDR2 Memory Interface ....................................................... 1-4
WPCM450R PCI System Interface ............................................................ 1-4
Other Features Supported by the WPCM BMC Controller ........................ 1-4
SATA Drive Power ........................................................................................... 1-5
Super I/O ......................................................................................................... 1-5
1-3 Server Chassis Features ................................................................................1-5
System Power ................................................................................................. 1-5
SAS/SATA Subsystem .....................................................................................1-5
I/O Ports ..........................................................................................................1-5
Cooling System ............................................................................................... 1-6
Air Shrouds ..................................................................................................... 1-6
Mounting Rails ................................................................................................ 1-6
1-4 Advanced Power Management ....................................................................... 1-6
Intel® Intelligent Power Node Manager (NM) .................................................1-6
Manageability Engine (ME) ............................................................................. 1-6
1-5 Contacting Supermicro ....................................................................................1-8
1-6 Fat Twin: System Notes .................................................................................. 1-9
Nodes ..............................................................................................................1-9
System Power ................................................................................................. 1-9
SAS/SATA Backplane/Drives .......................................................................... 1-9
Chapter 2 Server Installation
2-1 Overview .........................................................................................................2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup ......................................................................................... 2-1
2-4 Warnings and Precautions .............................................................................. 2-2
FatTwin F617H6-FTL+/FTPTL+ User's Manual
vii
Choosing a Setup Location .............................................................................2-2
Rack Precautions ............................................................................................ 2-2
Server Precautions ..........................................................................................2-2
Rack Mounting Considerations ....................................................................... 2-3
Ambient Operating Temperature ................................................................ 2-3
Reduced Airfl ow ......................................................................................... 2-3
Mechanical Loading ...................................................................................2-3
Circuit Overloading ..................................................................................... 2-3
Reliable Ground ......................................................................................... 2-4
2-5 Rack Mounting Instructions .............................................................................2-4
Identifying the Sections of the Rack Rails ...................................................... 2-4
Adjusting the Rails .......................................................................................... 2-4
Locking Tabs ...................................................................................................2-5
Installing the Rails on a Rack ......................................................................... 2-6
Chassis Installation ......................................................................................... 2-7
2-6 Checking the Serverboard Setup ....................................................................2-8
2-7 Checking the Drive Bay Setup ........................................................................2-9
Chapter 3 System Interface
3-1 Overview .........................................................................................................3-1
3-3 F414IS Front I/O Control Panel ...................................................................... 3-1
3-4 Control Panel LEDs ........................................................................................3-2
Chapter 4 Standardized Warning Statements for AC Systems
4-1 About Standardized Warning Statements ....................................................... 4-1
Warning Defi nition ........................................................................................... 4-1
Installation Instructions ....................................................................................4-4
Circuit Breaker ................................................................................................ 4-5
Power Disconnection Warning ........................................................................ 4-6
Equipment Installation ..................................................................................... 4-8
Restricted Area ................................................................................................ 4-9
Battery Handling ............................................................................................4-10
Redundant Power Supplies ..........................................................................4-12
Backplane Voltage ........................................................................................ 4-13
Comply with Local and National Electrical Codes ........................................ 4-14
Product Disposal ........................................................................................... 4-15
Hot Swap Fan Warning .................................................................................4-16
Power Cable and AC Adapter ...................................................................... 4-18
Table of Contents
viii
Chapter 5 Advanced Motherboard Setup
5-1 Handling the Motherboard ..............................................................................5-1
Precautions .....................................................................................................5-1
Unpacking .......................................................................................................5-1
5-2 Connecting Cables .......................................................................................... 5-2
Connecting SATA Power Cables .....................................................................5-2
Connecting Data Cables ................................................................................. 5-2
5-3 Control Panel Connectors and I/O Ports ........................................................ 5-2
5-4 Processor and Heatsink Installation................................................................5-3
Installing a CPU Heatsink ............................................................................... 5-7
Removing the Heatsink ................................................................................... 5-7
5-5 Installing Memory ............................................................................................5-8
Removing Memory Modules ........................................................................... 5-9
Memory Support ..............................................................................................5-9
5-6 Serverboard Details ...................................................................................... 5-16
5-7 Connector Defi nitions .................................................................................... 5-19
5-8 Jumper Settings ............................................................................................ 5-23
Explanation of Jumpers ................................................................................5-23
5-9 Onboard Indicators ........................................................................................5-25
5-10 Serial ATA Connections ................................................................................. 5-27
5-11 Installing Drivers ............................................................................................5-28
SuperDoctor III .............................................................................................. 5-29
5-12 Serverboard Battery ......................................................................................5-31
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices ..................................................................................6-1
Precautions .....................................................................................................6-1
Unpacking .......................................................................................................6-1
6-2 Control Panel ..................................................................................................6-2
6-3 Removing the Power Cord ..............................................................................6-3
6-4 Removing Nodes from the Chassis ................................................................ 6-3
6-5 Removing the Node Cover..............................................................................6-4
6-6 Installing and Removing Hard Drives ............................................................. 6-5
Replacing Fixed 3.5" Hard Drives ...................................................................6-6
6-7 Node Confi guration .........................................................................................6-7
6-8 Removing and Installing the Backplane ..........................................................6-8
Removing the Backplane ................................................................................ 6-8
6-9 Power Adapter Board Replacement ..............................................................6-10
6-10 Installing the Motherboard ............................................................................6-11
Compatible Motherboards ..............................................................................6-11
FatTwin F617H6-FTL+/FTPTL+ User's Manual
Permanent and Optional Standoffs ................................................................6-11
6-11 Installing Expansion Cards ...........................................................................6-13
PCIE Slot Setup ............................................................................................ 6-13
Installing a Low-Profi le Expansion Card ....................................................... 6-14
Installation Complete .....................................................................................6-15
6-12 Replacing Exhaust Fans ............................................................................... 6-16
6-13 Replacing the Power Supply .........................................................................6-18
Power Supply Replacement ..........................................................................6-19
Chapter 7 BIOS
7-1 Introduction ...................................................................................................... 7-1
Starting BIOS Setup Utility ..............................................................................7-1
How To Change the Confi guration Data ......................................................... 7-2
Starting the Setup Utility ................................................................................. 7-2
7-2 Main Setup ...................................................................................................... 7-2
7-3 Advanced Setup Confi gurations...................................................................... 7-3
7-4 Event Logs .................................................................................................... 7-23
7-5 IPMI ............................................................................................................... 7-25
7-6 Boot ............................................................................................................... 7-27
7-7 Secur ity ......................................................................................................... 7-28
7-8 Save & Exit ................................................................................................... 7-29
Appendix A System Specifi cations
ix
Table of Contents
x
Notes
FatTwin F617H6-FTL+/FTPTL+ User's Manual
Chapter 1
Introduction
1-1 Overview
The FatTwin F617H6-FTL+/FTPTL+ is a high-end server comprised of two main subsystems: the F414IS-R1K62B 4U server chassis and the X9DRFF-7G+/7TG+ dual processor serverboard in four hot-swap nodes. Please refer to our web site for information on operating systems that have been certifi ed for use with the system (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have been included with the FatTwin F617H6-FTL+/FTPTL+ server, as listed below:
Four (4) 1U passive front CPU heat sinks (SNK-P0047PSC)
Four (4) 1U passive CPU heat sinks for MB w/ narrow ILM (SNK-P0047PS)
Four (4) power adapter boards (BPN-ADP-F418L-O-P)
Power Cables:
Four (4) 8pin to 2x2pin (50cm) and 2 SATA power connectors (46cm) and (16cm) 18AWG power cables (CBL-PWEX-0511-01) Four (4) 8 pin to 2 2x2(50/60-cm) and 2 SATA (26+16-cm) 18AWG power cables (CPL-PWEX-0485-01)
SAS/SATA Backplane and accessories:
Four (4) backplanes for twelve (12) 3.5" HDD ( BPN-SAS-816T-A3-O-P) Eight (8) 1U Hadroop backplanes for thirty-two (32) 3.5" HDD (BPN-SAS-816T-A4-O-P) Twelve (12) 21-cm 30AWG SATA S-S cables (CBL-0473L) Eight (8) 29-cm 30AWG SATA S-S cables (CBL-0483L) Twelve (12) 81-cm 30AWG SATA S-S cables (CBL-0481L) Eight (8) 29-cm 30AWG SATA S-S cables (CBL-0483L) Sixteen (16) 55-cm 30AWG SATA S-S cables (CBL-0484L)
Riser Cards:
Four (4) 1U LHS FatTwin PCI-E x8 riser cards with (RSC-R1UFF-E8-O-P) Four (4) PCI-E x4 riser cards (RSC-R1UFF-E8R-O-P)
One (1) F418/F424 rail set (MCP-290-41803-0N)
Chapter 1: Introduction
1-1
1-2
FatTwin F617H6-FTL+/FTPTL+ User's Manual
Note: If you are using the optional PWS-2K02P-1R power supply you will need to use the C13 to C14 size 14AWG wire power cord set for the rack.
Note: For your system to work properly, please follow the links below to download all necessary drivers/utilities and the user’s manual for your server.
Supermicro product manuals: http://www.supermicro.com/support/manuals/
Product drivers and utilities: ftp://ftp.supermicro.com
Product safety information:
http://super-dev/about/policies/safety_information.cfm
If you have any questions, please contact our support team at:
support@supermicor.com
1-2 Serverboard Features
At the heart of the FatTwin F617H6-FTL+/FTPTL+ lies the X9DRFF-7G+/7TG+, a dual processor serverboard based on the Intel® C602 chipset. Below are the main features of the serverboard. (See Figure 1-1 for a block diagram of the chipset.)
Processors
The X9DRFF-7G+/7TG+ supports single or dual Intel® E5-2600 series processors in Socket R LGA 2011 sockets. Please refer to the serverboard description pages on our web site for a complete listing of supported processors (www.supermicro.com).
Memory
The X9DRFF-7G+/7TG+ has sixteen (16) memory sockets that can support up to 512 GB of ECC registered RDIMMs or up to 128 GB of unbuffered ECC/non-ECC UDIMMs in DDR3-1600/1333/1066/800 MHz speed, 1 GB, 2 GB, 4 GB, 8 GB, 16 GB or 32 GB size, and .at 1.35 or 1.5 voltages. Please refer to Chapter 5 for installing memory.
Note: For the latest CPU/memory updates, please refer to our website at
http://www.supermicro.com/products/motherboard.
Onboard SAS
An LSI 2308 SAS controller provides eight SAS2 ports. The SAS drives are connected to a backplane that provides power, bus termination and confi guration settings. RA ID 0, 1, and 10 are suppo rte d.
Note: The operating system you use must have RAID support to enable the hotswap c apabil ity an d R AID fu ncti on of the SA S drive s.
1-3
Chapter 1: Introduction
Onboard Serial ATA
A SATA controller is integrated into the chipset to provide a twelve-port SATA subsystem. Two of the por ts suppor t SATA 3. 0 (RAID 0 an d 1) a nd ten suppor t SATA 2. 0 (R AID 0, 1, 5 and 10). See Chapte r 5 for deta ils.
Note: The operating system you use must have RAID support to enable the hotswap c apabil ity an d RA ID fu nctio n of the SATA drives.
PCI Expansion Slots
Each node in the the FatTwin F617H6-FTL+/FTPTL+ has 1x PCI-E 3.0 x8 low-profi le and 1x PCI-E 2.0 x4 low-profi le expansion slots. Two riser cards are provided for each node for use with these expansion slots.
I/O Ports
The color-coded I/O ports located at the front of each node in the server include a VGA (monitor) port, two USB 2.0 ports, two 1 Gb Ethernet ports (X9DRFF-7G+) or two 10 Gb Ethernet ports (X9DRFF-7TG+) and one dedicated IPMI LAN port.
Note: For IPMI Confi guration Instructions, please refer to the Embedded IPMI Configuration User's Guide available @ http://www.supermicro.com/support/
manuals/.
Graphics Controller
The X9DRFF-7G+/7TG+ features an integrated Matrox G200ew, 16 MB DDR2 graphics controller.
Nuvoton WPCM450 Controller
Note: The term "IPMI controller" and the term "BMC controller" can be used
interchangeably in this section. The Nuvoton WPCM450R Controller, a Baseboard Management Controller (BMC),
supports 2D/VGA-compatible Graphic Cores with PCI interface, creating multi-media virtualization via Keyboard/Video/Mouse Redirection (KVMR). The WPCM450R Controller is ideal for remote system management.
The WPCM450R Controller interfaces with the host system via PCI connections to communicate with the graphics cores. It supports USB 2.0 and 1.1 for remote keyboard/mouse/virtual media emulation. It also provides LPC interface support to control Super IO functions. The WPCM450R Controller is connected to the network via an external Ethernet PHY module or shared NCSI connections.
1-4
FatTwin F617H6-FTL+/FTPTL+ User's Manual
The WPCM450R communicates with onboard components via six SMBus interfaces, PECI (Platform Environment Control Interface) buses, and General Purpose I/O ports.
WPCM450R DDR2 Memory Interface
The WPCM450R supports a 16-bit DDR2 memory module with a speed of up to 220 MHz. For best signal integrity, the WPCM450R provides point-to-point connection.
WPCM450R PCI System Interface
The WPCM450R provides 32-bit, 33 MHz 3.3V PCI interface, which is compliant with the PCI Local Bus Specifi cation Rev. 2.3. The PCI system interface connects to the onboard PCI Bridge used by the graphics controller.
Other Features Supported by the WPCM BMC Controller
The WPCM450R supports the following features:
IPMI 2.0
Serial over LAN
KVM over LAN
LAN Alerting-SNMP Trap
Event Log
X-Bus parallel interface for I/O expansion
Multiple ADC inputs, Analog and Digital Video outputs
SPI Flash Host BIOS and rmware bootstrap program supported
Reduced Media Independent Interface (RMII)
OS (Operating System) Independency
Provides remote Hardware Health Monitoring via IPMI. Key features
Provides Network Management Security via remote access/console redirection.
Supports the following Management tools: IPMIView, CLI (Command Line
Interface)
RMCP+ protocol supported
Note: For more information on IPMI confi guration, please refer to the IPMI User's Guide posted on our website at http://www.supermicro.com/support/manuals/.
1-5
Chapter 1: Introduction
SATA Drive Power
Please connect the onboard power cables (four each CBL-0511L and CBL-0485L) from each node's serverboard to the SATA backplane board in the node tray in order to provide power to the drives.
Super I/O
The Super I/O provides functions that comply with ACPI (Advanced Confi guration and Power Interface), which includes support of legacy and ACPI power management through an SMI or SCI function pin. It also features auto power management to reduce power consumption.
1-3 Server Chassis Features
The following is a general outline of the main features of the F414IS server chassis.
System Power
The F414IS chassis model includes two high-effi ciency 94%+ Platinum certifi ed redundant 1620 Watt power supplies. In the unlikely event your power supply fails, replacement is simple and can be accomplished without tools.
SAS/SATA Subsystem
The F414IS supports up to twelve (12) fi xed SAS/SATA drives (plus two (2) optional
2.5" SATA drives) for each node for a total of fi fty-six (56) drives. The F414IS supports 3.5" and optional 2.5" hard drives. These drives are fi xed units and are connected to three backplanes (that provides power and control) per node.
Note: For more information, visit our Web site at: http://www.supermicro.com.
I/O Ports
The F414IS is an proprietary form factor chassis designed to be used in a 4U rackmount confi guration. The F414IS chassis provides two low-profi le add-on card slots, a VGA port, two USB 2.0 ports, one IPMI Ethernet port and two gigabit (F617H6-FTL+) or two 10G (F617H6-FTPTL+) Ethernet ports per node.
1-6
FatTwin F617H6-FTL+/FTPTL+ User's Manual
Cooling System
The F414IS chassis supports external exhaust fans that provide cooling for the system. The F617H6-FTL+/FTPTL+ server uses eight (8) 8-cm external system fans powered from either the backpane or the serverboards. When one of the motherboard nodes is removed, another motherboard will continue to operate the fans.
Air Shrouds
The F414IS chassis requires mylar air shrouds for each node to direct the airfl ow where cooling is needed. The air shroud will differ for different motherboards. If using a motherboard which is not the default in the chassis, refer to the optional parts in the Appendix of this manual, or the Supermicro Web site at www.supermicro.com to puchase the proper air shroud.
Mounting Rails
The F414IS includes a set of rails, and can be placed in a rack for secure storage and use. To setup your rack, follow the step-by-step instructions included in this manual.
1-4 Advanced Power Management
Intel® Intelligent Power Node Manager (NM)
The Intel® Intelligent Power Node Manager (IPNM) provides your system with real-time thermal control and power management for maximum energy effi ciency. Although IPNM Specifi cation Version 1.5 is supported by the BMC (Baseboard Management Controller), your system must also have IPNM-compatible Manageability Engine (ME) fi rmware installed to use this feature.
Manageability Engine (ME)
The Manageability Engine, which is an ARC controller embedded in the IOH (I/O Hub), provides Server Platform Services (SPS) to your system. The services provided by SPS are different from those proveded by the ME on client platforms.
1-7
Chapter 1: Introduction
Figure 1-1. Intel C602 Chipset:
System Block Diagram
Note: This is a general block diagram and may not exactly repre-
sent the features on your motherboard. See the previous pages for
the actual specifi cations of your motherboard. This block diagram is
intended for your reference only.
P0 P1
PE2PE1 DMI
DDR3 DIMM
CPU1
E5-2600 Series Processor
F
E
Rear (Fan Side)
#2
#1
DDR3 DIMM
#2
#1
PE3
Gen3 x8 (0~7)
Gen3 x16 x16 Gen3 x8
Gen3 x16 Gen3 x8 (8~15) Gen3 x8 (0~7)
Gen2 x4
VGA CONN
LAN
RJ45 RJ45
PHY RTL8201F
LAN
X540
SAS2308
AT25321
6/3/1.5
3/1.5
3/1.5
3/1.5
3/1.5
6/3/1.5
I350 (2 ports)
PCI-Ex16x16
Proprietary SLOT
PCI-Ex16
Proprietary SLOT
PCI-Ex8 SLOT
SAS
DDR3 DIMM
H
G
#2
#1
DDR3 DIMM
#2
#1
PCH C602
J1
J2
PCI-Ex8 SLOT
J3
PCI-Ex4 in x8 SLOT
J4
AHCI
SATA
USB
SPI
USB
LPCPCI-32bit
DMI
PEG2_5:7
PEG2_0:4
DDR3 DIMM
D
C
#2
#1
#2
#1
DDR3 DIMM
B
A
#2
#1
DDR3 DIMM
QPI
QPI
Gen2 x4
#2
#1
SAS2 #4
SAS2 #3
SAS2 #2
SAS2 #1
SAS2 #8
SAS2 #7
SAS2 #6
SAS2 #5
WPCM450
VGA BMC
DDR2
DDR3 DIMM
P1 P0
PE2PE1 DMI
CPU0
E5-2600 Series Processor
Front (I/O Side)
PE3
SATA2 #3
SATA2 #4
SATA2 #5
SATA2 #6
SATA3 #1
SATA3 #2
Type A
Single
Single
01 2
1-8
FatTwin F617H6-FTL+/FTPTL+ User's Manual
1-5 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support) Web Site:
www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support) Web Site:
www.supermicro.nl
Asia-Pacifi c
Address: Super Micro Computer, Inc.
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 235
Taiwan (R.O.C) Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3992 Email: support@supermicro.com.tw Web Site:
www.supermicro.com.tw
1-9
Chapter 1: Introduction
1-6 Fat Twin: System Notes
As a FatTwin confi guration, the FatTwin F617H6-FTL+/FTPTL+ is a unique server system. With four system boards incorporated into a single chassis acting as four separate nodes, there are several points you should keep in mind.
Nodes
Each of the four serverboards act as a separate node in the system. As independant nodes, each may be powered off and on without affecting the others. In addition, each node is a hot-swappable unit that may be removed from the rear of the chassis. The nodes are connected to the server backplane by means of an adapter card.
Note: A guide pin is located between the upper and lower nodes on the inner chassis wall. This guide pin also acts as a “stop” when a node is fully installed. If too much force is used when inserting a node this pin may break off. Take care to slowly slide a node in until you hear the “click” of the locking tab seating itself.
System Power
Four high-effi ciency 94%+ Plus Platinum Level 1620 Watt power supplies are used to provide the power for all serverboards. Each serverboard however, can be shut down independently of the other with the power button on its own control panel.
SAS/SATA Backplane/Drives
As a system, the FatTwin F617H6-FTL+/FTPTL+ supports the use of up to fi fty- six (56) drives SAS/SATA drives. Each of the backplanes in the system logically connects the internal fi xed SAS/SATA drives to each node's backplane/serverboard. See Chapter 6 for the logical hard drive and node confi guration.
1-10
FatTwin F617H6-FTL+/FTPTL+ User's Manual
Notes
Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your FatTwin F617H6-FTL+/FTPTL+ up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a serverboard, processors, system memory etc., please turn to the chapter or section noted in each step for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the FatTwin F617H6-FTL+/FTPTL+ was shipped in and note if it was damaged in any way. If the server itself shows damage you should le a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the FatTwin F617H6-FTL+/FTPTL+. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fi elds are generated. You will also need it placed near a grounded power outlet. Read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the FatTwin F617H6-FTL+/FTPTL+ was shipped in should include two sets of rail assemblies, two rail mounting brackets and the mounting screws you will need to install the system into the rack. Follow the steps in the order given to complete the installation process in a minimum amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow.
2-2
FatTwin F617H6-FTL+/FTPTL+ User's Manual
2-4 Warnings and Precautions
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for suffi cient airfl ow and ease in servicing.
This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets and the like).
This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to
the fl oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the
rack.
You should extend only one component at a time - extending two or more
simultaneously may cause the rack to become unstable.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
Determine the placement of each component in the rack before you install the
rails.
Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power failure.
Allow any hot plug drives and power supply modules to cool before touching
them.
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
Chapter 2: Server Installation
2-3
Rack Mounting Considerations
Warning! To prevent bodily injury when mounting or servicing this unit in a
rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
When mounting this unit in a partially fi lled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
2-4
FatTwin F617H6-FTL+/FTPTL+ User's Manual
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).
2-5 Rack Mounting Instructions
This section provides information on installing the chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure will differ slightly from the instructions provided. You should also refer to the installation instructions that came with the rack unit you are using.
Note: This rail will fi t a rack between 26.5" and 36.4" deep. The SCF418 is not designed for installation into a Telco post-style rack unit.
Warning: Do not pick up the server with the front handles. They are
designed to pull the system from a rack only.
Stability Hazard: The rack stabilizing mechanism must be in place, or the rack must be bolted to the fl oor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over.
Warning: When initially installing the server to a rack, test that the rail locking tabs engage to prevent the server from being overextended. Have a rack lift in place as a precaution in case the test fails.
Warning: In any instance of pulling the system from the rack, always use a rack lift and follow all associated safety precautions.
Identifying the Sections of the Rack Rails
The chassis package includes two rail assemblies in the rack mounting kit. Each assembly consists of three sections: An inner chassis rail which secures directly to the chassis, an outer rail that secures to the rack, and a middle rail which extends from the outer rail. These assemblies are specifi cally designed for the left and right side of the chassis (see Figure 2-1).
Adjusting the Rails
Each rail assembly has an adjusting screw. loosening this screw allows you to adjust the length of the rail to fi t a variety of rack sizes.
Chapter 2: Server Installation
2-5
Figure 2-1: Identifying the Outer Rail and Inner Rails
(Left Rail Assembly Shown)
Inner Rail
This Side Faces
Outward
Adjusting Screw
Outer Rail
Locking Tab
Locking Tabs
Each inner rail has a locking tab. This tab locks the chassis into place when installed and pushed fully into the rack. These tabs also lock the chassis in place when fully extended from the rack. This prevents the server from coming completely out of the rack when when the chassis is pulled out for servicing.
2-6
FatTwin F617H6-FTL+/FTPTL+ User's Manual
Installing the Rails on a Rack
Installing the Rails
1. Adjust the length of both rails as described on the previous page.
2. Align the front section of the outer rail with the slots on the front post of the
rack. Secure the front of the outer rail to the rack with two screws.
3. Pull out the rear section of the outer rail, adjusting the length until it fi ts within
the posts of the rack.
4. Align the rear section of the rail with the slots on the rear post of the rack.
Secure the rear of the outer rail to the rear of the rack with two screws.
5. Repeat steps 1-4 for the remaining rail.
Figure 2-2: Attaching the Rails to a Rack
Chapter 2: Server Installation
2-7
Note: The fi gure above is for illustration purposes only. Always install servers to the bottom of the rack fi rst.
Figure 2-3: Installing into a Rack
Chassis Installation
Installing the Chassis into a Rack
1. Confi rm that the rails are correctly installed on the rack.
2. Align the bottom of the chassis with the bottom of the rails.
3. Insert the chassis into the rails, keeping the pressure even on both sides, pushing the chassis into the rack until it clicks into the locked position.
4. Secure the chassis handles to the front of the rack.
2-8
FatTwin F617H6-FTL+/FTPTL+ User's Manual
2-6 Checking the Serverboard Setup
After you install the SuperServer F617H6-FTL+/FTPTL+ in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made.
Accessing the inside of the System
Before operating the server for the rst time, it is important to remove the protective lm covering the top of the chassis, in order to allow for proper ventilation and
cooling.
Warning: Except for short periods of time, do NOT operate the server without the cover in place. The chassis cover must be in place to allow proper airfl ow and prevent overheating.
Checking the Components and Setup
1. You may have one or two processors already installed into the serverboard. Each processor needs its own heat sink. See Chapter 5 for instructions on processor and heat sink installation.
2. Your SuperServer F617H6-FTL+/FTPTL+ server system may have come with system memory already installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.
3. If desired, you can install add-on cards to the system. See Chapter 5 for details on installing PCI add-on cards.
4. Make sure all power and data cables are properly connected and not blocking the chassis airfl ow. Also make sure that no cables are positioned in front of the fans. See Chapter 5 for details on cable connections.
Chapter 2: Server Installation
2-9
2-7 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the SATA drives have been properly installed and all connections have been made.
Checking the Drives
1. For the F617H6-FTL+/FTPTL+ server, all hard drives are fi xed on the motherboard tray and can only be retrieved by removing the top cover.
2. Depending upon your system's confi guration, your system may have one or more drives already installed. If you need to install hard drives, please refer to Chapter 6.
Checking the Airfl ow
1. Make sure there are no objects to obstruct airfl ow in and out of the server. In addition, if you are using a front bezel, make sure the bezel's fi lter is replaced periodically.
2. Do not operate the server without drives or drive trays in the drive bays. Use only recommended server parts.
3. Make sure that no wires or foreign objects obstruct air fl ow through the chassis. Pull all excess cabling out of the airfl ow path or use shorter cables. The control panel LEDs inform you of the system status. See “Chapter 3 System Interface” for details on the LEDs and the control panel buttons.
Providing Power
1. Plug the power cord(s) from the power supply unit(s) into a high-quality power strip that offers protection from electrical noise and power surges. It is recommended that you use an uninterruptible power supply (UPS).
2. Depress the power on button on the front of the chassis.
2-10
FatTwin F617H6-FTL+/FTPTL+ User's Manual