INSTALLATION INSTRUCTIONS FOR BLOWER KIT
MODEL FAB-1100
GENERAL INFORMATION
The FAB-1100 forced air blower kit consists of a 105 CFM dual
blower assembly.
The blower supplies air delivery at 105 CFM at 0" H2O static pressure,
90 CFM at 0.2" H2O static pressure. The maximum operating static
pressure is 0.38" H2O.
The FAB-1100 has been tested and certified by CSA.
Always check local building codes. The installation must comply with
local regulations as well as the National Electric Code.
Failure to follow these instructions could cause a fireplace malfunction resulting in possible injury and/or property damage.
PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
PRELIMINARY INSPECTION
P/N 903249
REV. E 11/2004
Figure 1
FORCED AIR BLOWER KIT
FAB-1100
Magnets
Blower
in Position
Magnets
Make Entry where No Obstructions are Present.
Outlet
Plenums
Remove the blower kit from the carton and check for any damage.
Check inventory: blower assembly, sleeved power cord and installation instructions.
INSTALLING THE BLOWER
Step 1. In most appliances the FAB-1100 blower is simply posi-
tioned against the appliance back wall, with the magnets engaging
the sheetmetal rear wall to secure the blower in place. Generally
access to this location is gained by the opening (or removal) of the
appliance lower compartment door of louvers
Step 2. The blower is properly positioned when it is centered against
the appliance rear wall with the outlet plenums pointed upwards
(
Figure 2
appliance base. Ensure that the blower is positioned against the
appliance back wall. Some appliances are fitted with a blower shield
preventing access to the back wall of the appliance. In this case
remove the shield, place the blower, complete its installation, then
replace the shield.
Step 3. Route the blower sleeved power cord to a switched, standard
grounded three pronged outlet mounted on the appliance internal "J"
box cover plate prewired at the time of appliance installation (see page
2 of this document,
with hot appliance surfaces. Operate the FAB-1100 from the switch
controlling power to the appliance junction box.
). Ensure that the blower base is firmly seated on the
Figure 3
). Ensure power cord minimizes contact
Figure 1
.
Blower
Base
FAB-1100
Blower
Figure 2
Note: The FAB-1100 may also be used with the PureHeat appliance and
the CGI-BAY and GI-3821 gas inserts. For use with the PureHeat and
CGI-BAY appliances follow the instructions in their installation documents and those found in the PHEXK and CBEK kits respectively. The
FAB-1100 is installed in the GI-3821 in accordance with instructions
provided with that appliance.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
1
Blower Plug
ON/OFF Wall Switch
}
120Vac
60Hz
Junction Box
Figure 3
APPLIANCE WIRING
Most appliances are fitted with an electrical "J" box that can be
accessed from outside of the appliance outer wrapper at the time of
installation. The following general instructions apply.
WARNING: DO NOT CONFUSE BLOWER 120 VAC 60HZ
WIRING CIRCUIT WITH THE APPLIANCE LOW VOLTAGE
(MILLIVOLT) OPERATING CIRCUIT.
CAUTION: ELECTRICAL CONNECTIONS SHOULD ONLY BE PERFORMED BY A QUALIFIED, LICENSED ELECTRICIAN. MAIN POWER
SUPPLY MUST BE TURNED OFF BEFORE CONNECTING FANS TO
MAIN ELECTRICAL POWER SUPPLY OR PERFORMING SERVICE.
Step 1. Remove the external "J" box cover by removing the hex-head
screw. The receptacle should be wired into an electrical circuit
during the framing of the appliance.
The “J” box cover has a 7/8" (22mm) diameter knockout hole for
connection of a conduit bushing.
Step 2. Wire with minimum 600 C wire in accordance with prevailing
codes. The blower draws 1 amp at 120 Vac 60Hz.
CAUTION: MAIN POWER SUPPLY MUST BE TURNED OFF BEFORE
EXTERNAL WIRING IS PERFORMED.
Factory Supplied
Not Supplied with Blower Kit
Step 3. Connect the ground wire to the ground screw located on the
inside of the “J” box or on the “J” box plate.
Step 4. Replace the “J” box cover back onto the side access opening
and secure with the hex head screw.
Step 5. Connect the wall switch (not provided with blower kit) to the
supply wires in the wall receptacle box (
Figure 4
).
Wall Box
To Blower
Neutral
Switch Plate
White
Supply
Black Black
Switch
Figure 4
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.