WARNING: If the information in these instructions is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a quali
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
AVERTISSEMENT
UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
AVERTISSEMENT: Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire
au minimum le risque d’incindie ou d’explosion ou
pour éviter tout dommage matériel, toute blessure
ou la mort.
- Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où vous
-
trouvez.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR
tation ultérieure.
: Conservez cette notice pour consul-
- L’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par
le fournisseur de gaz.
Page 2
CONGRATULATIONS!
GENERAL INFORMATION
In selecting this Superior direct-vent gas appliance you have chosen the finest and most
dependable fireplace to be found anywhere. It's a beautiful, prestigious alternative to a
wood burning fireplace. Welcome to a family of tens of thousands of satisfied Superior
fireplace owners.
Please carefully read and follow all of the instructions found in this manual. Please pay
special attention to the safety instructions provided in this manual. The care and operation instructions included here will assure that you have many years of dependable and
enjoyable service from your Superior fireplace.
Replacement Parts List .....................Page 24
This manual is part of a set of two supporting
this product. Refer to manual 700,031M for
Installation Instructions.
INTRODUCTION
The fireplace models covered in this manual
are direct-vent sealed combustion gas fireplace
heaters designed for residential application.
These direct-vent appliances operate with the
combustion chamber completely isolated from
the indoor environment.
All air for combustion is brought in from the
outside and exhaust gases are vented through
the same direct-vent, co-axial (intake/exhaust)
vent system.
The Millivolt appliances have a millivolt gas
control valve with piezo ignition system. If any
optional accessories which require electrical
power are being installed, the electrical power
must be provided at the time of appliance
installation.
The Electronic appliances have an electronic
intermittent pilot system. External electrical
power is required to operate these appliances.
These appliances comply with National Safety
Standards and are tested and listed by OMNITest Laboratories, Inc. (Report No.116-F-32-5)
to ANSI Z21.88b (in Canada, CSA-2.33b), and
CAN/CGA-2.17-M91 in both USA and Canada,
as vented gas fireplace heaters.
The Installation must conform to local codes
or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA
54-latest edition, or the Natural Gas and
Propane Installation Code, CSA B149.1-latest
edition. The appliance, when installed, must
be electrically grounded in accordance with
local codes or, in the absence of local codes,
the latest edition of the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical Code,
CSA C22.1 - latest editions.
WARNING
Children and adults should be
alerted to the hazards of high
surface temperature and should
stay away to avoid burns or
clothing ignition.
AVERTISSEMENT
Les enfants et les adultes
devraient être infor-més des
dangers que posent les températures de surface élevées et se
tenir à distance afin d’éviter des
brûlures ou que leurs vêtements
ne s’enflamment.
WARNING
Clothing or other flammable
material should not be placed
on or near the appliance.
AVERTISSEMENT
On ne devrait pas placer de
vêtements ni d’autres matières
inflammables sur l’appareil ni
à proximité.
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause injury
or property damage. Refer to
this manual. For assistance or
additional information consult
a qualified installer, service
agency or the gas supplier.
DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE
OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE
WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT.
2
Page 3
Note: Installation and repair should be
done by a qualified service person. The
appliance should be inspected before use
and at least annually by a professional
service person. More frequent cleaning
may be required due to excessive lint from
carpeting, bedding material, etcetera. It
is imperative that control compartments,
burners and circulating air passageways
of the appliance be kept clean. See maintenance instructions on Page 8.
Remarque : L’installation et la réparation devrait être confiées à un technicien
qualifié. L’appareil devrait faire l’objet
d’une inspection par un technicien professionnel avant d’être utilisé et au moins
une fois l’an par la suite. Des nettoyages
plus fréquents peuvent être nécessaires si
les tapis, la literie, et cetera produisent
une quantité importante de pous-sière.
Il est essentiel que les compartiments
abritant les commandes, les brûleurs
et les conduits de circulation d’air de
l’appareil soient tenus propres.
Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect
the appliance and to replace any part of
the control system and any gas control
which has been under water.
Ne pas utiliser cet appareil s’il a été
plongé, même partiellement, dans
l’eau. Appeler un technicien qualifié
pour inspecter l’appareil et remplacer
toute partie du système de commande
et toute commande qui a été plongée
dans l’eau.
Only trim kit(s) supplied by the manufacturer shall be used in the installation of
this appliance.
Seules les trousses de garniture fournies
par le fabricant doivent être utilisées pour
l’installation de cet appareil.
Provide adequate clearances around
air openings and adequate accessibility
clearance for service and proper operation. Never obstruct the front openings
of the appliance.
Due to high temperatures the appliance
should be located out of traffic and away
from furniture and draperies. Locate
furniture and window coverings accordingly.
En raison des températures élevées,
l’appareil devrait être installé dans un
endroit où il y a peu de circulation et loin
du mobilier et des tentures.
The vent termination is hot while in
operation and for a period of time following the use of the fireplace. Young
children should be carefully supervised
when they are in the same area as a
hot termination. To prevent contact with
hot surfaces, we recommend the use of
a termination guard. See Page 15 for
ordering information.
These fireplaces are designed as supplemental heaters. Therefore, it is advisable
to have an alternate primary heat source
when installed in a dwelling.
These appliances are designed to operate
on natural gas or propane gas only. The
use of other fuels or combination of fuels
will degrade the performance of this system
and may be dangerous.
These appliances must not be connected to
a chimney or flue serving a separate solid
fuel burning appliance.
Carbon Monoxide Poisoning: Early signs
of carbon monoxide poisoning are similar to the flu with headaches, dizziness
and/or nausea. If you have these signs,
obtain fresh air immediately. Turn off the
gas supply to the appliance and have it
serviced by a qualified professional, as
it may not be operating correctly. Some
people are more affected by carbon
monoxide than others. These include
pregnant women, people with heart or
lung disease or anemia, those under
the influence of alcohol, and those at
high altitudes.
WARNING
These fireplaces are vented
gas appliances. Do not burn
wood or other material in these
appliances.
WARNING
Failure to comply with the installation and operating instructions
provided will result in an improperly installed and operating
appliance, voiding its warranty.
Any change to this appliance
and/or its operating controls is
dangerous. Improper installation or use of this appliance can
cause serious injury or death
from fire, burns, explosion or
carbon monoxide poisoning.
WARNING
This appliance is only for use with
the type of gas indicated on rating
plate. This appliance is not convertible for use with other gases,
unless a certified kit is used.
AVERTISSEMENT
Cet appareil doit être utilisé
uniquement avec les types de
gaz indiqués sur la plaque signalétique. Ne pas l'utiliser avec
d'autres gaz sauf si un kit de
conversion certifié est installé.
WARNING
Hot while in operation. Do not
touch. Severe Burns may result.
Keep children, clothing furniture,
gasoline and other liquids having
flammable vapors away.
AVERTISSEMENT
L’appareil est chaud lorsqu’il fonctionne. Ne pas toucher l’appareil.
Risque de brûlures graves.
Surveiller les enfants. Garder
les vêtements, les meubles,
l’essence ou autres liquides
produisant des vapeur inflammables loin de l’appareil.
3
Page 4
Millivolt Models - BTU Input
Millivolt models come standard with the manually-modulated gas valve; flame appearance and
heat output can be controlled at the gas valve.
The BTU Input for millivolt models is shown
in Table 1:
Input (BTU) Manually-Modulated Gas
Valves (millivolt models)
ModelsFuel TypeInput Rate
(BTU / HR)
SSDVST
SSDVPF
Natural or
Propane Gas
37,500 high
30,000 low
Table 1
Electronic Models -
Electronic models have a fixed rate gas valve.
The BTU Input for electronic models is shown
in Table 2:
Input (BTU) - Fixed Rate
(electronic models)
ModelsFuel TypeInput Rate
(BTU / HR)
SSDVST
SSDVPF
Natural or
Propane Gas
37,500
Table 2
Gas Pressure -
Tables 3 and 4 show the appliances' gas
pressure requirements.
Inlet Gas Supply Pressure
(all models)
Fuel #MinimumMaximum
Natural Gas
Propane
5.0" WC
(1.24 kPa)
11.0" WC
(2.74 kPa)
10.5" WC
(2.61 kPa)
13.0" WC
(3.23 kPa)
Table 3
Test gauge connections are provided on the
front of the millivolt gas control valve, identified IN for the inlet and OUT for the manifold
side (see Figure 3 on Page 6). A 1/8" NPT Test
gauge connection is provided at the inlet and
outlet (manifold) ports on the electronic gas
control valve (see Figure 4 on Page 6).
These appliances must be isolated
from the gas supply piping system (by
closing their individual manual shut-off
valve) during any pressure testing of
the gas supply piping system at test
pressures equal to or less than 1/2 psig
(3.5 kPa).
These appliances and their individual
shut-off valves must be disconnected
from the gas supply piping system during any pressure testing of that system
at pressures greater than 1/2 psig (3.5
kPa).
Orifice Sizes - Sea Level to High Altitude
(All Models)
These appliances are tested and approved for
installation at elevations of 0-4500 feet (0-1372
meters) above sea level using the standard
burner orifice sizes (marked with an "*" in Table
5). For elevations above 4500 feet, contact your
gas supplier or qualified service technician.
Deration - At higher elevations, the amount
of BTU fuel value delivered must be reduced
by either:
• Using gas that has been derated by the gas
company.
• Changing the burner orifice to a smaller size
as regulated by the local authorities having
jurisdiction and by the (USA) National Fuel
Gas Code NFPA 54/ANSI Z223.1 - latest
edition or, in Canada, the CAN/CSA-B149.1
codes - latest edition.
Burner Orifice Sizes
Elevation 0-4500 feet ( 0-1372 meters)
Model
Series
SSDVST
SSDVPF
Table 5
Nat.Gas
drill size (inches)
#44 (.086")
* Standard size installed at factory
** Standard size in LP conversion kit
• Part /Cat. Number
60J80 •
*
Propane
drill size (inches)
#55 (.052")
19L52 •
**
Burn-in Period
During the first few fires of this appliance there
will be some odor due to the curing of the
paint and burning off of lubricants used in the
manufacturing process. Depending on your
use, the burn-in period may take a few hours
or a few days.
KEEP YOUR HOUSE WELL VENTILATED
DURING THE CURING PROCESS. THE ODOR
AND HAZE EMITTED DURING THE CURING
PROCESS CAN BE QUITE NOTICEABLE AND
MAY SET OFF A SMOKE DETECTOR.
If an optional blower is installed, Do Not turn
it on during the Burn-In period.
A white film may develop on the glass front
during the first few fires as part of the curing
process. The glass should be kept clean during
the first two weeks of use to prevent the film from
baking on (making it very difficult to remove).
See Cleaning Glass on Page 8.
Manifold Gas Supply Pressure
(all models)
Fuel #Low
(millivolt only)
Natural
Gas
Propane
(Lo) 2.2" WC
(.55 kPa)
(Lo) 6.3" WC
(1.57 kPa)
High
(Hi) 3.5" WC
(.87 kPa)
(Hi) 10.0" WC
(2.49 kPa)
Table 4
4
Install the appliance according to the regulations
of the local authorities having jurisdiction and,
in the USA, the National Fuel Gas Code NFPA
54 / ANSI Z223.1 - latest edition or, in Canada,
the CAN/CSA-B149.1 - latest edition.
NOTE: Flame appearance will diminish 4% per
thousand feet.
NOTE: Each model has two burners and 2
Orifices.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 5
OPERATION AND CARE OF YOUR APPLIANCE
WARNING
Young children should be carefully supervised when they are in the
same room as the appliance. Toddlers, young children and others
may be susceptible to accidental contact burns. A physical barrier is
recommended if there are at risk individuals in the house. To restrict
access to a fireplace or stove, install an adjustable safety gate to keep
toddlers, young children and other at risk individuals out of the room
and away from hot surfaces.
On millivolt systems, the piezo igniter, HI/LO
flame adjustment knob, and pilot and main gas
OFF/PILOT/ON control knob are located below
the glass panel enclosure. The gas valve for
electronic systems is also located below the
glass enclosure panel. See Figure 1.
Reinstalling Control Compartment Door:
To reinstall, insert the hook catches on each
side of the door into the corresponding slots
in the control compartment opening, then
gently push forward and slide down until it
locks in place.
AVERTISSEMENT
Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trouvent dans la même pièce que l’appareil. Les tout petits, les jeunes enfants
ou les adultes peuvent subir des brûlures s’ils viennent en contact avec
la surface chaude. Il est recommandé d’installer une barrière physique
si des personnes à risques habitent la maison. Pour empêcher l’accès
à un foyer ou à un poêle, installez une barrière de sécurité; cette mesure
empêchera les tout petits, les jeunes enfants et toute autre personne à
risque d’avoir accès à la pièce et aux surfaces chaudes.
Control Compartment Access
Glass Door is Above
Control Compartment
Latch for
Glass Door
HI/LO (flame height
control knob)
Optional OFF/ON
Switch Can be
Installed Here
OFF/PILOT/ON (gas control knob)
Gas Shut-Off
Gas Flex-Line
Piezo Igniter
Gas Valve
The standard controls for appliance operation
are located behind the lower louvered control
compartment door located below the appliance
front glass enclosure panel (see Figure 1).
Optional control switches are also available (see
Page 14 - Rocker Switch, Remote Wall Switch,
Remote Control, Unit Mounted Rocker Switch
or Wall Thermostat).
Operation of millivolt and electronic gas control systems are different. Before lighting and
operating your appliance determine if you have
a millivolt or electronic appliance. Familiarize
yourself with the gas control valve that your
appliance uses. Refer to Figure 2 for access
to the gas control valve.
Millivolt Appliances - Appliances with
Millivolt systems will be fitted with the gas
control valve shown in Figure 3 on Page
6.
Electronic Appliances - Appliances with
electronic systems will be fitted with the
electronic valve shown in Figure 4 on Page
6.
Millivolt Appliances
Figure 1
OPENING CONTROL
COMPARTMENT DOOR
Control Valve
Figure 2
Lift the Lower Control
Compartment Door
up and pull out to
remove.
Hook Catch
Out
Up
Lower Control
Compartment Door
Gas Controls/Control Compartment
Access
The gas controls can be found behind the control
compartment access door.
NOTE: The top louvered panel and the bottom
louvered control compartment door will remove
and install the same way as follows:
Removing Control Compartment Door:
Open the door by gently lifting it upward until
the hook catches on both sides clear the locating
slots. Then pull door out to remove.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
To light millivolt appliances refer to Figure
1. Detailed lighting instructions are found on
Pages 17 and 18. Millivolt appliance lighting
instructions may also be found on the pull out
lighting instruction labels attached to the gas
control valve.
Once the pilot is lit, the main burner may be
turned ON and OFF using a wall switch, remote
control, optional on unit rocker switch (FRS), or
wall thermostat. To operate: Toggle the switch
between its ON and OFF positions.
If your millivolt appliance is equipped with an
optional remote switch kit (wall switch, remote
control, rocker switch, or wall thermostat) and
the pilot is lit, the appliance main burner may be
turned on and off using the optional switch.
Note: To prevent excessive resistance in burner
circuit (which can cause burner operation
problems), only one burner control switch
should be wired to valve.
5
Page 6
F
F
O
N
I
P
S
I
NO
L
O
R
T
N
O
C
G
I
N
T
I
ER
H
I
L
O
W
H
TPT
HT
P
T
P
I
L
O
T
P
I
L
O
T
O
N
it
O
F
F
IN
OUT
Electronic Appliances -
To light electronic appliances refer to detailed
lighting instructions found on Pages 19 and
20. Electronic appliance lighting instructions
may also be found on the pull out lighting
instruction labels attached to the gas control
valve.
Once the pilot is lit, if your electronic appliance is
equipped with an optional burner control switch
kit the appliance main burner may be turned on
and off using the optional switch (See optional
accessories on Page 14 - Wall Switch, Wall
Thermostat Or Remote Control Receiver).
All Millivolt appliances are equipped with a
variable gas control valve. Flame height for
these models may be adjusted through a range
between fixed low and high settings while the
appliance is in operation. Adjust the flame
height as desired after lighting the appliance
by rotating the variable adjustment control
knob (HI/LO) located on the front of the valve
(refer to Figure 3).
Manifold Pressure
ON / OFF Switch
Port
Inlet
Pressure
Port
Electronic Gas
Control Valve
Figure 4 - Honeywell Electronic Gas Valve
6
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 7
La chimenea caliente causará quemaduras graves
Nunca permita que los niños
toquen el vidrio ni otras
partes de la chimenea
ADVERTENCIA
Un foyer chaud peut causer
de graves brûlures
Ne laissez jamais un enfant
toucher à la vitre ou à toutes
autres parties du foyer
A
VE
R
TISSEMENT
Hot Fireplace Will Cause
Severe Burns
Never Allow Children to
Touch Glass or other Fire-
place Parts
WARNING
Hot Fireplace Will Cause
Severe Burns
Never Allow Children to
Touch Glass or other Fireplace Parts
WARNING
HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS
ATTACHING SAFETY IN OPERATION WARNINGS
Your fireplace has been furnished with safety instruction labels that are to be affixed to the operation and
control point of the fireplace. A safety instruction
label should be affixed to the wall switch plate where
the fireplace is turned on and off (See Figure A) or
wall thermostat (See Figure B) and if used on the
remote control handheld transmitter (Figure C).
The warnings should already have been put in place
when the fireplace initial set-up was completed.
If they are not affixed at these spots, locate the
multi-lingual adhesive labels provided with these
instructions and proceed as follows:
1. Locate the wall switch or wall thermostat that
controls the fireplace (verify the switch operates
the fireplace by turning it on and off). Clean the
wall switch plate or wall thermostat thoroughly
to remove any dust and oils. Affix the label to
the surface of the plate of the wall switch that
controls the fireplace (Figure A) or the wall
thermostat (Figure B). Choose the language
primarily spoken in the home.
2. If a remote control is used to control the fireplace,
locate the transmitter and clean it thoroughly
to remove any dust and oils. Affix the label to
the surface of handheld transmitter (Figure C).
Choose the language primarily spoken in the
home.
3. If you are unable to locate the labels, please call
Lennox Hearth Products or your nearest Lennox
Hearth Products dealer to receive additional
safety instruction labels free of charge.
Cat. No. H8024 Replacement Label Kit
LENNOX HEARTH PRODUCTS
1-800-9-LENNOX
Note: English is red text on clear label. French and
Spanish are white text on black label.
APPOSITION DES MISES EN GARDE RELATIVES
À LA SÉCURITÉ D’UTILISATION
Votre foyer a été livré avec des étiquettes de sécurité qui
doivent être collées à côté des dispositifs de contrôle
du foyer. Une étiquette de sécurité doit être collée sur
la plaque de l’interrupteur contrôlant l’allumage du
foyer (voir Figure A) ou sur le thermostat mural (voir Figure B) et, le cas échéant, sur le boîtier de la télé-
commande (Figure C). Les mises en garde auraient dû
être collées au moment de l’installation initiale du foyer.
Si ce n’est pas le cas, prenez les étiquettes adhésives
multilingues fournies avec ces instructions et procédez
comme suit:
1. Repérez l’interrupteur ou le thermostat mural
qui contrôle le foyer (vérifiez que l’interrupteur
contrôle le fonctionnement du foyer en le faisant
basculer de Marche à Arrêt, et vice-versa). Nettoyez
soigneusement la plaque murale de l’interrupteur
ou le thermostat mural pour éliminer la poussière
et les traces de graisse ou d’huile. Collez l’étiquette
sur la surface de la plaque de l’interrupteur mural
qui contrôle le foyer (Figure A) ou du thermostat
mural (Figure B). Choisissez la langue qui est
principalement parlée dans la résidence du
propriétaire.
2. Si une télécommande est utilisée pour contrôler
le foyer, nettoyez la soigneusement pour éliminer
la poussière et les traces de graisse ou d’huile.
Collez l’étiquette sur le boîtier de la télécommande
(Figure C). Choisissez la langue qui est principale-
ment parlée dans la résidence du propriétaire.
3. Si vous ne trouvez pas les étiquettes, veuillez
appeler Lennox Hearth Products ou votre distributeur Lennox Hearth Products local pour recevoir
gratuitement des étiquettes supplémentaires.
Étiquettes de remplacement, n° cat. H8024
LENNOX HEARTH PRODUCTS
1-800-9-LENNOX
Remarque : Le texte anglais est rouge sur un support
transparent. Le texte français et espagnol est blanc
sur un support noir.
COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD
EN OPERACIóN
Su chimenea incluye etiquetas de instrucciones
de seguridad que deben colocarse en el punto de
operación y control de la chimenea. Se debe colocar
una etiqueta de instrucciones de seguridad en la placa
del interruptor de pared desde el cual se enciende y se
apaga la chimenea (ver la Figura A) o en el termostato
de pared (ver la Figura B) y en el transmisor de control
remoto (Figura C) si se usa. Las advertencias ya deben
haberse colocado cuando se completó la instalación
inicial de la chimenea. Si no están colocadas en estos
lugares, encuentre las etiquetas adhesivas multilingües
proporcionadas con estas instrucciones y prosiga de
la siguiente manera:
1. Identifique el interruptor o el termostato de pared
que controla la chimenea (verifique que el interruptor
opera la chimenea encendiéndola y apagándola).
Limpie bien la placa del interruptor o el termostato de
pared para quitar el polvo y aceite. Pegue la etiqueta
en la superficie de la placa del interruptor que controla
la chimenea (Figura A) o en el termostato de pared
(Figura B). Seleccione el idioma que más se habla
en la casa.
2. Si se usa un control remoto para controlar la
chimenea, encuentre el transmisor y límpielo bien
para quitar el polvo y aceite. Pegue la etiqueta en la
superficie del transmisor (Figura C). Seleccione el
idioma que más se habla en la casa.
3. Si no puede encontrar las etiquetas, sírvase llamar
a Lennox Hearth Products o al distribuidor de
Lennox Hearth Products más cercano para recibir
etiquetas de instrucciones de seguridad adicionales
gratuitas.
Juego de etiquetas de repuesto - Nº de cat. H8024
LENNOX HEARTH PRODUCTS
1-800-9-LENNOX
Nota: La etiqueta en inglés es transparente con texto
rojo. Las etiquetas en francés y español son negras
con texto blanco.
Un foyer chaud peut causer
de graves brûlures
Ne laissez jamais un enfant
toucher à la vitre ou à toutes
autres parties du foyer
Figure A
DIAGRAMMES DES ÉTIQUETTES DE SÉCURITÉ / DIAGRAMAS DE ETIQUETAS DE SEGURIDAD / SAFETY LABEL DIAGRAMS
AVERTISSEMENT
ADVERTENCIA
La chimenea caliente
causará quemaduras graves
Nunca permita que los niños
toquen el vidrio ni otras
partes de la chimenea
Figure B
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure C
7
Page 8
MAINTENANCE
(See Maintenance Schedule, Page 21)
Refer to the maintenance schedule for maintenance tasks, procedures, frequency and
by whom they should be performed. Always
verify proper operation of the appliance after
servicing.
WARNING
Turn off gas and electrical power
to the fireplace and allow it to
cool before cleaning or servicing
the appliance.
CAUTION: Wear gloves and safety
glasses for protection while doing
required maintenance.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adéquatement une fois l'entretien terminé.
Always turn off gas to the pilot (millivolt
appliances) before cleaning. Before relighting, refer to the lighting instructions
in this manual. Instructions are also found
on a pull-out panel located in the control
compartment.
Inspect Venting System
The appliance and venting system should be
thoroughly inspected before initial use and
at least annually by a qualified service technician (inspection should include ensuring that
exhaust or intake passages are unobstructed
and vent components are properly assembled
and not damaged). Homeowner must contact
a qualified service technician at once if any
abnormal condition is observed.
If the venting system is disassembled for any
reason, a qualified service technician should
follow vent installation instructions for proper
reassembly and proper sealing of the venting
system components. However, more frequent
periodic inspections and cleanings should be
performed by the homeowner.
Cleaning Glass
(see Front Glass Enclosure Panel, Removal and
Installation on Page 9).
Note: Clean glass after first two weeks of opera-
tion (after Burn-In period is over) and then only
when necessary and when the fireplace is cool.
Wipe surface with clean, dampened, soft cloth.
Follow with a dry, soft towel as desired. Take
care not to scratch the glass surface.
IMPORTANT: Do not use abrasive cleaners on glass. Never clean the glass when
it is hot.
The viewing glass should be cleaned periodically to remove any build-up caused from the
following:
• During start-up, it is normal for condensa
tion to form on the inside of the glass (this
condensation and fog will usually disappear
in a few minutes). The moisture can cause
lint, dust and other airborne particles to cling
to the glass surface.
• Initial curing of the high temperature paint
and burning off of lubricants used in the
manufacturing process may result in a film
on the glass.
• A white coating may form on the glass as
a result of impurities and minerals in the
fuel.
It is recommended that the glass be cleaned
two or three times during each heating season,
depending on the circumstances present. The
following cleaning solutions are approved for
use to clean glass:
• Non-ammonia based household cleaner
• 50%-50% mix of white vinegar and water
• Gas fireplace/stove glass cleaner
Inspect Glass Gasket - Visually inspect the
gasket on the backside of the glass enclosure
panels. The gasket surface must be clean, free
of irregularities and seated firmly.
Clean Control Compartment
Keep control compartment clean by vacuuming
or brushing at least twice a year. More frequent
cleaning may be required due to excessive lint
from carpeting, bedding materials, etc. It is
important that control compartments, burners
and circulating air passageways of the appliance
be kept clean.
Clean Logs And Burner
Carefully remove the logs (use care when handling the fiber logs, as they become quite fragile
after curing). Vacuum out any foreign matter
(lint, carbon, etc.) on the burner. Ensure the
burner ports are “open.” Remove any carbon
deposits from the under side of the logs using
a vacuum cleaner, or a soft bristled brush (i.e.
paint brush).
Replacing Logs
If the logs become damaged by accident or
improper handling and need replacement,
use only the proper replacement logs from
manufacturer (see Page 24 for ordering
information).
Re-Install Embers, Logs and Volcanic Stone
Carefully follow placement instructions on
Page 10. All logs should fit onto corresponding pins and/or log stoppers. This will ensure
a proper flame and safe combustion.
Inspect Wiring
Refer to wiring diagrams on Page 13.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring
errors can cause improper and dangerous
operation. Verify proper operation after
servicing.
ATTENTION: Au moment de l'entretien
des commandes, étiquetez tous les fils
avant de les débrancher. Des erreurs
de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux.
Inspect and clean all wire connections. Ensure
that there is no melting or damage. Inspection
should include:
• Terminals at the Valve
• OFF/ON Switch
• (Optional Control Switch) Wall Thermostat,
Remote Control or Remote Wall Switch Kit
Inspect Burner Flame Appearance
Ensure that the burner flame appearance
resembles the flame shown in Figures 7 and
10 and as described in Flame Appearance and
Sooting on Page 11. The Homeowner must
contact a qualified service technician at once
if any abnormal condition is observed.
Small Area Paint Touch-up
Only use a factory supplied paint kit for
touch-ups. Paint is available at your local
authorized LHP dealer. Never attempt to paint
a hot fireplace.
If the surface later becomes stained or marred,
it may be lightly sanded and touched up with
spray paint.
Note: Improper positioning of logs can create
carbon build-up and will alter the performance
8
of the appliance.
Page 9
Front Glass Enclosure Panel, Removal
and Installation
WARNING
• Do not attempt to substitute the
materials used on this door,
or replace cracked or broken
glass.
• Handle this glass with extreme
care! Glass is susceptible to
damage – Do not scratch or
handle roughly while reinstalling the glass door frame.
• The glass door of this appli-
ance must only be replaced
as a complete unit as provided
by the manufacturer. Do not
attempt to replace broken,
cracked or chipped glass separately.
• Do not attempt to touch the
front enclosure glass with your
hands while the fireplace is in
use.
WARNING
Do not operate appliance with
the glass front removed, cracked
or broken.
AVERTISSEMENT
Ne pas utiliser l'appareil si le
panneau frontal en verre n'est
pas en place, est craqué ou
brisé.
WARNING
Any safety screen or guard
removed for servicing the appliance must be replaced prior to
operating the appliance.
AVERTISSEMENT
Tout écran ou protecteur retiré
pour permettre l’entretien de
l’appareil doit être remis en
place avant de mettre l’appareil
en marche.
Only doors certified with the appliance
shall be used.
Seules des portes certifiées pour cet
appareil doivent être utilisées.
CAUTION: DO NOT abuse glass door by
striking or slamming shut.
These are direct-vent appliances. They are
designed to operate only when the front glass
enclosure panels are installed. Generally the
front glass enclosure panel should not be removed except to gain access to the components
within the firebox.
Removing Glass Enclosure Panels
(see Figure 5)
1. Remove the top louver assembly the control
compartment louver assembly by lifting them
up, then pulling out (see Figure 2 on Page
5).
2. Locate the two (2) latches at the top of the
control compartment. To disengage the two
latches from the bottom vee-flange of the
glass enclosure panel, reach for the handles
located towards the back of the latches and
pull the handles down toward the front of
the appliance.
3. Swing the bottom of the door out and raise
it slightly to lift the top flange of the door
frame away from the appliance.
Installing Glass Enclosure Panels
(see Figure 5)
1. Visually inspect the gasket on the backside of
the panels. The gasket surface must be clean,
free of irregularities and seated firmly.
2. Position the glass enclosure panel in front
of the firebox opening at a 45 degree angle
and engage the top flange over the lip at the
top of the firebox opening.
3. Swing the glass enclosure panel down and
back. Ensure the gasket seats evenly as the
panel draws shut. Engage the Vee-flange at
the bottom of the panel with the latches and
close the latches to secure the panel.
4. Reinstall the lower control compartment
door (see Figure 2 on Page 5).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Top Flange on
Glass Door
Glass Door
Bottom Vee-flange
Glass Door
Glass Door Latch
Note: When installing the glass door, ensure the
spacing on both sides are equal.
Figure 5
INSTALLING OR REMOVING GLASS DOOR
INSTALLING LOG SET, VOLCANIC STONE
AND GLOWING EMBERS
Firebox Floor
WARNINGS
• DO NOT attempt to install the
logs until the appliance installation has been completed, the
gas line connected and tested
for leaks and the initial burner
operation has been checked
out.
• The size and position of the log
set was engineered to give the
appliance a safe, reliable and
attractive flame pattern. Any
attempt to use a different log
set in the fireplace will void
the warranty and will result in
incomplete combustion, sooting, and poor flame quality.
• Logs get very hot and will
remain hot up to one hour
after gas supply is turned off.
Handle only when logs are
cool. Turn off all electricity
to the appliance before you
install grate, volcanic stone,
embers and logs.
9
Page 10
FRONT OF FIREPLACE
REAR BURNER
FRONT BURNER
Outer Log
Notch Location
FIREBOX SUBFLOOR
Outer Log
Notch Location
Outer Log
Notch Location
Outer Log
Notch Location
Riser - Inner Log
Notch Location
LOG NOTCH LOCATION RELATIVE TO BURNER
Pilot Assembly
Riser - Inner Log
Notch Location
NOTE: INSTALL REAR BURNER FIRST,
THEN FRONT BURNER.
BURNER POSITIONING
REAR BURNER
FRONT BURNER
PILOT
BURNER
Note: The burners are not identical. Position them so
that the circular burner ports run as shown. Note
especially the vertical run of ports relative to the pilot
burner. Bracket A on the rear burner will interfere
with the pilot burner if an attempt is made to install
the rear burner in the front burner’s position.
BRACKET A
BURNER
PORTS
NOTE: INSTALL REAR BURNER FIRST,
THEN FRONT BURNER.
WARNINGS
• This appliance is not designed
to burn wood. Any attempt to
do so could cause irreparable
damage to appliance and prove
hazardous to your safety.
• If logs are not installed according to the log installation
instructions, flame impingement and improper combustion could occur and result in
soot and/or excessive production of carbon monoxide (CO),
a colorless, odorless, toxic
gas.
Burner / Grate Location Reference
(see Figures 8 and 9)
Note: If the burners have been removed for any
reason, rear burner must be installed before
front burner. See Figures 8 and 9.
Install the decorative volcanic stone and
glowing embers (rockwool):
Spread the decorative volcanic stone on the
simulated brick floor of the firebox around
the burners to simulate ashes. Maintain a 1/2
inch (13 mm) gap between the bottom of the
horizontal grate section and the top of the pile
of decorative volcanic stone. Place a few quarter-sized pieces of the glowing ember material
on the pan burner in front of the burned out
area on both sides of the log set. The glowing
embers may touch one another, but should not
overlap each other.
Install the unitized log set:
a. The bottom of the log set is notched to ac
commodate the pilot.
b. Place the log set so that the four inner
notches on the underside of the log set fit
over the four risers located on the burner
ends. See Figure 7. This procedure is
accomplished primarily by feel, as the log
set masks the burner risers as it is being
installed.
c. As a final check for correct log set placement,
check that the four outer notches on the
underside of the log set fit over the burner
tines as indicated in Figure 7.
Glowing Embers
Separate into Quarter
Size (separate) Pieces
Bag of Glowing
Embers (rockwool)
Figure 6
REFERENCE
Firebox Accessories / Parts
Cat. No.Model No.Description
88L53FGEBag of Glowing Embers
Bag of Decorative
80L42
FDVS
Volcanic Stone
-
Figure 8
Figure 9
Proper Burner Flame Appearance
10
Figure 7
Unitized Log Set
Volcanic Stone
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 11
BURNER ADJUSTMENTS
(QUALIFIED TECHNICIANS ONLY)
Flame Appearance and Sooting
Proper flame appearance is a flame which is
blue at the base and becomes yellowish-orange
in the body of the flame. When the appliance
is first lit, the entire flame may be blue and will
gradually turn yellowish-orange during the first
15 minutes of operation. After 15 minutes of
operation, if the flame is blue, or if the flame is
orange with evidence of sooting (black tip), the
air shutter opening may need to be adjusted.
If the air shutter openings are closed too far,
sooting may develop. Sooting is indicated by
black puffs developing at the tips of very long
orange flames. Sooting results in black deposits
forming on the logs, appliance inside surfaces
and on exterior surfaces adjacent to the vent
termination.
Sooting is caused by incomplete combustion in
the flames and lack of combustion air entering
the air shutter opening. To achieve a warm
yellowish-orange flame with an orange body
that does not soot, the shutter opening must be
adjusted between these two extremes.
Figure 10 - Burner Flame Appearance
Air Shutter Adjustment Guidelines
• If there is smoke or soot present, first check
the log set positioning to ensure that the
flames are not impinging on any of the logs.
If the log set is properly positioned and a
sooting condition still exists, then the air
shutter opening should be increased.
• The more offsets in the vent system, the larger
the air shutter opening will need to be.
• An appliance operated with the air shutter
opened too far, may have flames that appear
blue and transparent. These weak, blue and
transparent flames are termed anemic.
•
Propane models may exhibit flames which
candle or appear stringy. If this is present and
persists, adjust the air shutter to a more open
position, then operate the appliance for a few
more minutes to ensure that the flame normalizes and the flames do not appear sooty.
The following chart is provided to aid you in
achieving the correct air shutter adjustment
for your installation.
Air Shutter Adjustment Guidelines:
Amount of
Primary Air
If air shutter is
closed too far
If air shutter is
open too far
Flame
Color
Flame will
be orange
Flame will
be blue
Air Shutter
Adjustment
Air shutter
gap should be
increased
Air shutter
gap should be
decreased
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
11
Page 12
Air Shutter
Adjusting
Rod
Air Shutter
Adjusting
Arms
Orifice
Increase Shutter
Opening In This
Direction
Decrease Shutter
Opening In This
Direction
Air Shutter
Opening
Burner
Venturi
Tube
Burner Air Shutter Adjustment Procedure
WARNINGS
•Air shutter adjustment should
only be performed by a qualified professional service
technician.
•Ensure front glass panel are
in place and sealed during
adjustment.
CAUTIONS
•Soot will be produced if the
air shutter is closed too much.
Any damage due to carboning
resulting from improperly
setting the air shutter is not
covered under the warranty.
• The air shutter door and nearby
appliance surfaces are hot.
Exercise caution to avoid
injury while adjusting flame
appearance.
1. Locate adjustment rod and adjust air shutter
to the standard setting as shown in Figure
11 (adjustment rod is located in the lower
control area).
Note: Rotating the adjustment rod coun-
terclockwise decreases air and clockwise
increases air.
2. Light appliance (follow lighting procedure on
lighting label in control compartment or see
care and operation manual).
Allow the burner to operate for at least 15
3.
minutes while observing the flame continuously to ensure that the proper flame appearance has been achieved (see Figures 7 and
10). If the following conditions are present,
adjust accordingly.
• If flame appears weak or sooty, adjust
the air shutter, incrementally, to a more
open position until the proper flame
appearance is achieved.
If flame stays lowered blue, adjust the
•
air shutter, incrementally, to a more
closed position until the proper flame
appearance is achieved.
4. Leave the control knob (off/pilot/on) in the
ON position and the burner OFF/ON switch
OFF (and remote switches, if applicable).
When satisfied that the burner flame appear-
5.
ance is normal, close the lower control
compartment door then proceed to finish
the installation.
***Main Burner Factory Air Shutter
Opening Setting - All Models
Natural Gas
inches (mm)
* TWO 1/8 (3) Slots ** TWO 11/16 (17) Slots
Adjustment Rod Positions, viewed from above:
* Natural Gas - fully clockwise
** Propane- fully counter clockwise
***Settings are shown for each burner.
Note - Both air shutters open and close
simultaneously when the air shutter adjusting
rod is moved.
Burners are omitted in this view for clarity.
Propane Gas
inches (mm)
Figure 11
Millivolt Appliance Checkout
The pilot flame should be steady, not lifting
or floating. Flame should be blue in color with
traces of orange at the outer edge.
The top 3/8" (10 mm) at the pilot generator
(thermopile) and the top 1/8" minimum (tip)
of the quick drop out thermocouple should be
engulfed in the pilot flame. The flame should
project 1" (25 mm) beyond the hood at all three
ports (see Figure 12).
To light the burner, refer to the lighting instructions on Pages 17 and 18.
MILLIVOLT PILOT ASSEMBLY
Proper Pilot Flame Appearance
Hood
Thermocouple
Pilot
Nozzels
Thermopile
Igniter Rod
3/8" Min.
(9 mm)
Figure 12
Ref. Air shutter Patent:
U.S. Pat. 5,553,603
Electronic Appliance Checkout
To light the burner, refer to the lighting instructions on Pages 19 and 20. Ensure the igniter
lights the pilot. The pilot flame should engulf
the flame sensor as shown in Figure 13.
ELECTRONIC PILOT ASSEMBLY
Proper Pilot Flame Appearance
Proper Flame
Adjustment
Pilot
Nozzels
3/8" to 1/2"
(9 -13 mm)
Ground
Electrode
Flame Rod
Hot Surface
Igniter
Figure 13
12
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 13
WARRANTY
Relay Module C/W FBK-250 only. Plug blower
into J-Box receptacle for FBK-100 or FBK-200
application. See View A for J-Box wiring.
Optional Blower
*OFF/ON Switch
(Integral with
Gas Valve)
Honeywell
Electronic
Gas
Valve
120 VAC
Primary
Secondary
Optional Control Switch
Junction Box
Pilot Burner
Assembly
BL
BL
Field Wired
Factory
Wired
BK = BLACK BL = BLUE
R = RED W = WHITE
G = GREEN
BK
W
BK
BK
BL
R
GROUND
24 V
Transformer
View A
J-Box Wiring when
using unit mounted
relay module.
BK
W
G
C
A V
0 2
1
Igniter
Connector
* Leave the OFF/ON switch, which is
integral with the gas valve, in the ON
position.
**Optional Control Switches: Wall
Switch, Wall Thermostat or Remote
Control Receiver.
Notes:
1. If any of the original wire as supplied
must be replaced, use Type AWM 105°C
- 18 gage wire ONLY.
2. 120 VAC, 60 Hz - Less than 3 Amps.
Caution: label all wires prior to
disconnection when servicing controls.
Wiring errors can cause improper and
dangerous operation.
TH
TP
TH
TP
Your gas appliance is covered by a limited twenty
year warranty. You will find a copy of the warranty accompanying this manual. Please read
the warranty to be familiar with its coverage.
Retain this manual. File it with your other documents for future reference.
REPLACEMENT PARTS
A complete parts list is found at the end of
this manual. Use only parts supplied from the
manufacturer.
With proper care and maintenance, your appliance will provide many years of enjoyment. If
you should experience any problem, first refer
to the troubleshooting guide in this manual.
If problem persists, contact your LHP dealer
or distributor.
Normally, all parts should be ordered through
your LHP distributor or dealer. Parts will be
shipped at prevailing prices at time of order.
When ordering repair parts, always give the
following information:
1. The model number of the appliance.
2. The serial number of the appliance.
LHP
1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
visit us at www.Lennox.com
1-800-9-LENNOX
PRODUCT REFERENCE INFORMATION
3. The part number.
4.
The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any
questions concerning the installation or ap-
We recommend that you record the following
important information about your fireplace.
Please call LHP for the phone number of your
nearest LHP dealer who will answer your questions or address your concerns.
plication of this system, please contact your
dealer or distributor.
Your Fireplace's Model Number ___________________________________________
Your Fireplace's Serial Number ___________________________________________
The Date On Which Your Fireplace Was Installed ______________________________
The Type of Gas Your Fireplace Uses _______________________________________
Your Dealer's Name ___________________________________________________
WIRING DIAGRAMS
Wiring diagrams are provided here for reference
purposes only. This information is also provided
on schematics attached directly to the appliance
on a pullout panel located within the control
compartment.
If any of the original wire as
supplied must be replaced,
it must be replaced with
Type AWM105o C - 18
gage wire.
* Optional Kits Installed - OFF/ON wall switch, wall
thermostat or remote control receiver. Note: Turn the
appliance-mounted OFF/ON burner control switch to the
OFF position if any of these kits are installed.
Figure 14
Millivolt Wiring Diagram
Thermopile
Standard OFF/ON Switch
*Optional Switch
Schematic Representation Only
Field Wired
Factory
Wired
CAUTION: LABEL ALL WIRES
PRIOR TO DISCONNECTION WHEN
SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER
AND DANGEROUS APPLIANCE
OPERATION.
Figure 15
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
ATTENTION : AU MOMENT DE
L'ENTRETIEN DES COMMANDES,
ÉTIQUETEZ TOUS LES FILS AVANT
DE LES DÉBRANCHER. DES
ERREURS DE CÁBLAGE PEU-VENT
ENTRAÎNER UN FONCTIONNEMENT
INADÉQUAT ET DANGEREUX.
The wall thermostat kit provides temperature control
for optimum comfort.
Cat. No.Model No.Description
H4635
ModelShip
Wt.
(36.2 cu.ft).
(36.2 cu.ft).
(36.2 cu.ft).
(36.2 cu.ft).
Wall Thermostat, Millivolt
DWTKWall Thermostat Kit,
White
Ship.
Volume
Standard Remote Control System
The Model RCL (Standard) Remote Control System,
features a simplistic OFF/ON control function for the
fireplace. This model includes a hand-held transmitter,
a remote receiver with wall-mount cover plate and
all hardware required to install the unit. The remote
receiver can be wall or hearth mounted.
The transmitter has ON and OFF functions that are
activated by pressing either button on the face of
the transmitter. When a button on the transmitter
is pressed, a signal light illuminates briefly to verify
that a signal has been sent.
The Model RCL is designed to operate with all millivolt ignition systems, as well as electronic ignition
systems. It may be installed with use for either
natural gas or propane gas appliances. The RCL
offers ease of installation and allows you to execute
on-off commands to the fireplace effortlessly with
one simple motion.
The Model RCL comes complete with detailed operating instructions.
Remote Control Kit, Standard
Cat. No.Model No.Description
H0249
(ref. Form # 750,127M)
RCLRemote Control System
(Standard)
Deluxe Remote Control System
The Model RCL-T (Deluxe) Remote Control System
has all of the features of the standard system along
with an added easy to read LCD screen which presents
access to many enhancements, including; battery
power level indicator, timer, mode of operation,
thermostatic display including room temperature in
either metric of English units, flame indicator and
clock. Fully programmable, the Model RCL-T allows
for virtual command over nearly all operational and
temperature variables, using the hand held remote
control transmitter.
The Model RCL-T (Deluxe) remote control system
is installed in the same manner as the standard
system, may be operated with electronic and millivolt systems with either natural gas or propane gas.
The RCL-T comes complete with detailed operating
instructions.
Remote Control Kit, Deluxe
Cat. No.Model No.Description
H0251RCL-STATRemote Control System
(Deluxe)
(ref. Form # 750,129M)
Unit-Mountable Rocker Switch
This rocker switch kit can be installed directly in
the gas valve mounting bracket (millivolt gas valve
equipped fireplaces) to provide On/Off operation in
lieu of a wall switch.
Rocker Switch Kit
Cat. No.Model No.Description
80L41
(ref. Form # 750,037M)
FRSRocker Switch Kit
14
OFF/ON Wall Switch Kit
The OFF/ON wall switch kit may be used to control
the operation of the fireplace burner or blower. Install
the OFF/ON wall switch in a convenient location near
the fireplace.
White Wall Switch Kit
Cat. No.Model No.Description
85L87FWSKOFF/ON Wall Switch Kit
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Variable Speed Wall Switch
Provides variable speed control if optional blower
kit is purchased.
Variable Speed Wall Switch
Cat. No.Model No.Description
045571H
VSWSVariable Speed Switch
Page 15
ACCESSORY COMPONENTS (CONTINUED)
Note: Door & Trim Kits are for 1 side only
Eyebrow Hood Kits
Polished BrassBrushed StainlessWhere Used
Cat. #ModelCat. #Model
98K28EB24PB88L47EB24BS24"
96K68EB40PB88L50EB40BS40"
* These hood kits replace the standard hood that comes with
these fireplaces.
(ref. Form #504,142M)
Barrier Screen Panel Kits
Cat. No.Model No. Models Where Used
26M49HG40M
98K74HG24
(ref. Form # 750,101M)
40 inch Wide Glass Door
24 Inch Wide Glass Door
Barrier Screen Panel Kit
This easy to install optional screen panel installs
over the standard glass enclosure panel to prevent
contact with the hot glass surface. These screen
panels cannot be used in conjunction with the arch
door kits or door frame kits.
Forced Air Blower Kits
Cat.
80L84
80L85FBK-200Blower, Variable Speed
80L86FBK-250Blower, Variable Speed
94L89
94L90
H0543
(ref. Form # 750,028M & 750,029M)
Model No.Description
No.
FBK-100Blower, Standard
(single speed)
(w/wall-mounted switch)
(w/unit-mounted switch)
FBK-100-36Blower, Standard, 36 Pack
FBK-200-36 Blower Kit - Variable Speed
with Wall Switch 36 Pack
FBK-250-36 Blower Kit - Variable Speed
with Thermo Snap Switch
36 Pack
Forced Air Kit
The FBK-100 blower provides constant velocity forced
air circulation. The FBK-200 assembly with variable
speed, wall-mountable switch provides variable speed
forced air circulation. The FBK-250 assembly with
variable speed unit-mountable switch, also provides
variable speed forced air circulation.
Polished Brass & Brushed Stainless Hood Kits
Attractive hoods are available in two styles. These hoods are designed to be fitted to the glass viewing sides
of the appliance. In addition to providing an aesthetically pleasing appearance to your appliance installation,
the hood reduces heat effects to decorative mantles and finish materials located above the fireplace opening.
The hood kit replaces the standard hood that comes with these appliances and snaps into place. These kits
can be retrofitted to previously installed appliances.
4 Piece Door Trim Kits
Polished BrassBrushed StainlessWhere Used
Cat. #ModelCat. #Model
26M83 4DFK40PB26M864DFK40BS40"
(ref. Form # 750,098M)
Door Frame Kits
A decorative door frame kit is available for use with these appliances. It is designed to attach directly to the
front face of the appliance at the four edges of the glass enclosure panel resulting in the appearance of a
picture frame.
* Assembled 8-Piece Louver Kits
Polished BrassBrushed StainlessWhere Used
Cat. #ModelCat. #Model
H1530LKE-600BH1531LKE-600BS
*H1526LK-600B*H1527LK-600BS
(ref. Form # 750,166M)
* Superior Nameplate Logo, 56L93, is not included.
24"
40"
Polished Brass and Brushed Stainless Louvers Kits
These kits include a top 4-louver assembly and a bottom 4-louver assembly. They provide a touch of elegance.
These kits can be retrofitted to previously installed appliances.
Termination Guard Kits
(all models)
Cat. No.Model No.Description
H58204.5HTSKTermination Shroud
87L02SV4.5HGSTermination Guard,
Deluxe
17M52SV4.5HGS-1Termination Guard,
Square
Termination Shroud
(ref. Form # 750,246M)
Deluxe Termination
(ref. Form # 750,055M)
Termination Guard Kits
The vent termination guards may be used to cover
the vent termination on the exterior of the home
to minimize exposure to the hot surface of the
termination.
Square Termination
(ref. Form # 750,109M)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
15
Page 16
P
A
I
N
T
ACCESSORY COMPONENTS (CONTINUED)
Arch Door Kit - Polished Brass
Cat. No. ModelWhere Used
80L95ADKE-60B24"
80L93ADK-6/60B40"
Arch Door Kit - Brushed Stainless Steel
Cat. No. ModelWhere Used
81L05ADKE-60P24"
81L03ADK-6/60P40"
(ref. Form # 750,021M)
Arch Door Kits
The arch door kits are easy to install and do not require hardware to attach them to the standard door frame.
The decorative arch kits can not be used in conjunction with the screen panel kit.
2- Piece Door Frame Kits
Polished BrassBrushed StainlessWhere Used
Cat. #ModelCat. #Model
26M94
19M89DTK-6B19M90DTK-6BS40"
(ref. Form # 750,098M)
DTKE-6B26M95DTKE-6BS24"
3 Piece Trim Kit (SSDVST only)
Cat. No. Model No.Description
96K22 TK40PB340" Polished Brass
H1816 TK40BS340" Brushed Stainless
H4823TK40C340" Black
(ref. Form # 750,147M)
2-Piece Door Trim Kits
These kits are designed to attach directly to the front face of the fireplace at the top and bottom edges of the
glass enclosure panel.
Touch-Up Paint Kits
(all models)
Cat. No.Model No.Description
90L73TPK-B Touch-Up Paint (Black)
(ref. Form # 750,050M)
Touch-Up Paint Kit
Repair of minor scratches and discoloration of the appliance painted surfaces may be accomplished with the
touch-up paint kit.
Radiant Panel Kits
Cat. #ModelWhere Used
80L79CFPKE60
80L77CFPK-6/60
(ref. Form # 750,030M)
24"
40"
4 Piece Trim Kit (SSDVST only)
Cat. No. Model No.Description
96K18TK40PB4
(ref. Form # 750,147M)
Decorative Firebox Accessories
Cat. No.Model No.Description
88L53FGE
80L42
(FDVS ref. Form #750,010M)
40” 4 Piece Finish Trim Kit,
Polished Brass
(all models)
Bag of Glowing Embers
(1 oz. rockwool)
FDVS
Bag of Decorative
Volcanic Stone
Bag of Glowing Embers
Bag of Volcanic Stone
Replacement ember materials or volcanic stone are
available for use with these appliances. Order kits as
part of the periodic maintenance of the appliance.
16
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 17
LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE
H
I
L
O
W
TPTH TPTH
P
I
L
O
T
P
I
L
O
T
O
N
it
O
F
F
OUT
IN
OFF
ON
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. This appliance has a pilot which must be lit with a piezo
igniter. When lighting the pilot, follow these instructions
exactly.
B. BEFORE
LIGHTING smell all around the appliance area for gas.
Ensure to smell next to the floor because some gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your
building.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Access the lower control compartment.
3. Turn OFF/ON switch to “OFF” (and remote wall switch, if
applicable).
4. Verify main line shut-off valve is open.
5. Push in gas control knob slightly and turn clockwise
to “OFF.”
SIT Millivolt Gas Valve
• Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire depart-
ment.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
do not try to repair it, call a qualified service technician. Force
or attempted repair may result in a fire or an explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
6. Wait five (5) minutes to clear out any gas. Then smell for gas, includ-
ing near the floor. If you smell gas, STOP! Follow “B” in the safety
information above (to the left) on this label. If you don’t smell gas, go
to the next step.
7. Push in gas control knob slightly and turn counterclockwise
to “PILOT.”
8. Push in control knob all the way and hold in. Immediately light the
pilot by triggering the spark igniter (pushing the button) until pilot
lights. Continue to hold the control knob in for about 1-1/2 minutes
after the pilot is lit. Release knob and it will pop back up. Pilot should
remain lit. If it goes out, repeat steps 5 through 8.
TP/TH
TP
TH
• If knob does not pop up when released, stop
and immediately call your service technician
or gas supplier.
Millivolt Pilot
• If pilot will not stay lit after several tries,
turn the control knob to “OFF” and call
your service technician or gas supplier.
9. Turn gas control knob counterclockwise
to “ON.”
BURNER
OFF/ON SWITCH
- LO / HI +
PIEZO
IGNITER
GAS CONTROL
KNOB
10. Close lower control compartment.
11.
If the appliance will not operate, follow the instructions "To Turn Off
Note: Knob cannot be turned from “PILOT” to “OFF”
Gas To Appliance" and call your service technician or gas supplier.
unless the knob is pushed in slightly. Do not force.
TO TURN OFF GAS TO APPLIANCE
1. Turn remote wall switch “OFF.” The pilot will remain lit for
normal service.
2. For complete shutdown, turn remote wall switch to “OFF.”
3. Access the lower control compartment.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
4. Depress gas control knob slightly and turn clockwise
to “OFF.” Do not force.
5. Close lower control compartment.
17
Page 18
INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT
H
I
L
O
W
TPTH TPTH
P
I
L
O
T
P
I
L
O
T
O
N
it
O
F
F
OUT
IN
OFF
ON
POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER
AVERTISSEMENT. QUICONQUE NE RESPECTE PAS À LA LETTRE LES INSTRUCTIONS DANS LA PRÉSENTE NOTICE RISQUE DE
DÉCLENCHER UN INCENDIE OU UNE EXPLOSION ENTRAÎNANT DES DOMMAGES, DES BLESSURES OU LA MORT.
A. Cet appareil est muni d’une veilleuse qui doit être allumée avec un
allumeur piézo-électrique. Lorsque vous allumez la veilleuse, suivre
exactement ces instructions.
B.AVANT L’ALLUMAGE: Avant d’allumer la veilleuse, reniflez tout autour
de l’appareil pour déceler une odeur de gaz. Reniflez près du plancher,
car certains gaz sont plus lourds que l’air et peuvent s’accumuler au
niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucun interrupteur ; ne pas vous servir des télépho
nes se trouvant dans le bâtiment.
INSTRUCTIONS D'ALLUMAGE
1. ARRÊTEZ ! Lisez les instructions de sécurité sur la portion supéri-
eure de cette étiquette..
2. Ouvrez le compartiment de contrôle du bas.
3. Tournez l’interrupteur mural à la position d’arrêt “OFF”.
4.
Ensurez-vous que la soupape d’arrêt de la canalisation principale est
ouverte.
5. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans
le sens des aiguilles d’une montre jusqu’à la position
d’arrêt “OFF”.
SIT Vanne Gaz Millivolt
TP/TH
TP
TH
- LO / HI + (COMMANDE
DE TAILLE DE FLAMME)
Interrupteur
(OFF/ ON)
BOUTON DE RÉGLAGE DU GAZ
ALLUMEUR
• Appelez immédiatement votre fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur, appelez le service des
incendies.
C. Ne pousser ou tourner la manette d’admission du gaz qu’à la main. Ne
jamais employer d’outil à cette fin. Si la manette reste coincée, ne tentez pas de la réparer; appelez un technicien qualifié. Quiconque tente
de forcer la manette ou de la réparer peut provoquer une explosion ou
un incendie.
D. N’utilisez pas cet appareil s’il a été plongé dans l’eau, même partielle-
ment. Faites inspecter l’appareil par un technicien qualifié et remplacez
toute partie du système de contrôle et toute commande qui ont été
plongés dans l’eau.
8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé.
Allumez immédiatement la veilleuse en déclenchant l’allume-gaz
à étincelle (en poussant le bouton) jusqu’à ce que la veilleuse
s’enflamme. Continuez de tenir le bouton de réglage enfoncé
pendant environ 90 secondes après l’allumage de la veilleuse.
Relâchez le bouton et il sortira subitement. La veilleuse devrait
rester allumée. Si elle s’éteint, répétez les étapes 5 à 8 inclusivement.
• Si le bouton ne sort pas automatiquement après avoir été relâché,
arrêtez immédiatement et téléphonez à votre technicien de service
ou à votre fournisseur de gaz.
• Si la veilleuse refuse de rester allumée après plusieurs tentatives,
tournez le bouton de réglage jusqu’à sa position d’arrêt “OFF” et
téléphonez à votre technicien de service ou à votre fournisseur de
gaz.
9. Tournez le bouton de réglage du gaz en sens inverse des aiguilles
d’une montre jusqu’à sa position de marche “ON”.
10. Fermez le compartiment de contrôle du bas.
11. Si l’appareil ne fonctionne pas,
Millivolt Pilot
suivre les instructions intitulées
Remarque: Il est impossible de tourner le bouton de “PILOT” à “OFF” à
moins qu’il ne soit légèrement enfoncé. Ne le forcez pas.
6. Attendre cinq (5) minutes pour laisser échapper tout le gaz. Reniflez
“Pour fermer le gaz qui alimente
l’appareil” et appeler un technicien
ou le fournisseur de gaz.
tout autour de l’appareil, y compris près du plancher, pour déceler
une odeur de gaz. Si vous sentez une odeur de gaz, ARRÊTEZ !
Passez à l’étape B des instructions de sécurité sur la portion supérieure (à gauche) de cette étiquette. S’il n’y a pas d’odeur de gaz,
passez à l’étape suivante.
7. Enfoncez légèrement le bouton de réglage du gaz et tournez-le en
sens inverse des aiguilles d’une montre jusqu’à la position de veilleuse “PILOT”.
POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL
1. Tournez l’interrupteur mural à la position d’arrêt “OFF”. La veilleuse
restera allumée jusqu’au retour du service normal.
2. Pour une fermeture complète, tournez l’interrupteur mural à la posi-
18
tion d’arrêt “OFF”.
3. Ouvrez le compartiment de contrôle du bas.
REMARQUE : LES SCHÉMAS ET LES ILLUSTRATIONS NE SONT PAS À L’ÉCHELLE
4. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans
le sens des aiguilles d’une montre jusqu’à la position
d’arrêt “OFF”. Ne forcez pas le bouton.
5. Fermez le compartiment de contrôle du bas.
Page 19
OPERATING INSTRUCTIONS — ELECTRONIC
F
F
O
N
I
P
S
I
NO
L
O
R
T
N
O
C
G
I
N
T
I
ER
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. This appliance is equipped with an ignition device which
automatically lights the pilot. Do not try to light the pilot
by hand.
B.BEFORE OPERATING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone
in your building.
OPERATING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Turn remote wall switch to “OFF.”
3. Open lower control compartment door.
4. Verify main line shut-off valve is open.
5. Turn the OFF/ON switch to “OFF”. Do not force.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire depart-
ment.
C. If any portion of this appliance does not operate as the
instructions indicate, do not try to repair it, call a qualified
service technician. Do not use tools. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been under
water.
6. Wait five (5) minutes to clear out any gas. Then smell
for gas, including near the floor. If you smell gas, STOP!
Follow “B” in the safety information above (to the left) on
this label. If you don’t smell gas, go to the next step.
7. Turn the OFF/ON switch to “ON”. Do not force.
8. Turn “ON” all electrical power to appliance (remote wall
or appliance switch).
Honeywell Electronic Gas Control Valve
ON / OFF Switch
Front View
TO TURN OFF GAS TO APPLIANCE
1. For complete shut-down, turn remote wall switch to
“OFF.”
2. Open lower control compartment door.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
9. Close lower control compartment door.
10.If the appliance will not operate, follow the instructions
"To Turn Off Gas To Appliance" and call your service technician or gas supplier.
TO SHUT OFF
1. Turn off all electrical power to the appliance (remote wall
switch).
3. Turn the OFF/ON switch to “OFF”. Do not force.
4. Close the main line shut-off valve.
5. Close lower control compartment door.
19
Page 20
INSTRUCTIONS D’ALLUMAGE — ELECTRONIC
F
F
O
N
I
P
S
I
NO
L
O
R
T
N
O
C
G
I
N
T
I
ER
POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE
AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU
UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.
A. Cet appareil est muni d’un dispositif d’allumage qui allume
automatiquement la veilleuse. Ne tentez pas d’allumer la veilleuse manuellement.
B. AVANT DE FAIRE FONCTIONNER:
reniflez tout autour de
l’appareil pour déceler une odeur de gaz. Reniflez près du
plancher, car certains gaz sont plus lourds que l’air et peuvent
s’accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucun interrupteur; ne pas vous servir des
téléphones se trouvant dans le bâtiment.
INSTRUCTIONS D’ALLUMAGE
1. ARRÊTEZ ! Lisez les instructions de sécurité sur la portion
supérieure (à gauche) de cette étiquette.
2. Tournez l’interrupteur mural à la position d’arrêt “OFF”.
3. Ouvrez la porte du compartiment de contrôle du bas.
• Appelez immédiatement votre fournisseur de gaz depuis un
voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur, appelez le service
des incendies.
C. Si un élément de cette unité ne fonctionne pas tel que
décrit dans les instructions, n’essayez pas de le réparer,
appelez un technicien qualifié. N’utilisez-pas d’outils. Le
fait de forcer la manette ou de la réparer peut déclencher
une explosion ou un incendie.
D. N’utilisez pas cet appareil s’il a été plongé dans l’eau,
même partiellement. Faites inspecter l’appareil par un
technicien qualifié et remplacez toute partie du système
de contrôle et toute commande qui ont été plongés dans
l’eau.
6. Attendez cinq (5) minutes pour l’evacuation du gaz. Si vous
décelez une odeur de gaz ARRÊTEZ ! Retournez au point “B”
des consignes de sécurité au verso de cette plaque. Si vous ne
remarquez aucune odeur de gaz, passez à l’étape suivante.
7. Tournez la manette de réglage du gaz jusqu’à la position de
marche “ON”. Ne la forcez pas.
20
4. Assurez-vous que la soupape d’arrêt de la canalisation principale
est ouverte.
5. Tournez la manette de réglage du gaz à la position d’arrêt
“OFF”.
Honeywell Vanne Gaz Électronique
Interrupteur ON / OFF
Vue de face
COMMENT COUPER L’ADMISSION DE GAZ DE L’APPAREIL
1. Pour une fermeture complète, tournez l’interrupteur mural à la
position d’arrêt “OFF”.
2. Ouvrez la porte du compartiment de contrôle du bas.
REMARQUE : LES SCHÉMAS ET LES ILLUSTRATIONS NE SONT PAS À L’ÉCHELLE
8. Ouvrez le courant électrique (“ON”) qui alimente l’appareil
(interrupteur mural ou l'appareil).
9. Fermez la porte du compartiment de contrôle du bas.
10. Si l’appareil ne fonctionne pas, suivre les instructions intitulées
“Pour fermer le gaz qui alimente l’appareil” et appeler un technicien
ou le fournisseur de gaz.
POUR ÉTEINDRE L’APPAREIL
1. Coupez tout le courant électrique qui alimente l’appareil (inter-
rupteur mural).
3. Tournez la manette de réglage du gaz à la position d’arrêt “OFF”.
Ne la forcez pas.
4. Fermez la soupape d’arrêt de la canalisation principale.
5. Fermez la porte du compartiment de contrôle du bas.
Page 21
MAINTENANCE SCHEDULE
Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
Annually (Before the onset of the Burning Season)
MAINTENANCE TASKACCOMPLISHING PERSONPROCEDURE
Inspect/Clean Burner, Logs
and Controls
Check Flame Patterns and Flame
Height
Inspect/Clean Pilot and BurnerQualified Service Technician
Check Vent SystemQualified Service TechnicianInspect the vent system at the top and at the base (within the
Appliance CheckoutQualified Service TechnicianPerform the appropriate appliance checkout procedure detailed
Qualified Service TechnicianInspect valve and ensure it is properly operating. Check piping
for leaks. Vacuum the control compartment, fireplace logs and
burner area.
Qualified Service Technician
Refer to Figure 10 on Page 11 and verify the flame pattern
and height displayed by the appliance conforms to the picture.
Flames must not impinge on the logs. Ensure flames are steady
(not lifting or floating).
Refer to Figures 12 and 13 on Page 12. Remove any surface
build-up on pilot and burner assembly. Wipe the pilot nozzles,
igniter/flame rod and hood. Ensure the pilot flame engulfs the
flame sensor as shown.
firebox) for signs of blockage or obstruction. Look for any signs
of dislocation or deterioration of the vent components. Note:
Excessive condensation can cause corrosion of caps, pipe &
fittings (excessive condensation can be caused by long lateral
runs, too many elbows and/or exterior portions of the system
being exposed to cold weather). Also inspect wall straps or
plumbers's tape to ensure it is secure and in place.
in this manual.
Replacing Glowing EmbersHomeowner/Qualified Service
Technician
Periodically (After the Burning Season)
Remove old ember materials (rockwool) and vacuum the ember
placement area. Place new embers as described on Page 10.
MAINTENANCE TASKACCOMPLISHING PERSONPROCEDURE
Clean Firebox InteriorHomeownerCarefully remove logs, embers (rockwool) and volcanic stone.
Vacuum out interior of the firebox. Clean firebox walls and log
grate. Replace logs, embers and volcanic stone as detailed in
this manual.
Check Flame Patterns and Flame
Height
Check Vent SystemHomeownerInspect the vent system at the top and at the base (within the
Clean Front Glass Enclosure PanelHomeownerClean as necessary following the directions provided in this
Homeowner
Refer to Figure 10 on Page 11 and verify the flame pattern
and height displayed by the appliance conforms to the picture.
Flames must not impinge on the logs.
firebox) for signs of blockage or obstruction. Look for any signs
of dislocation of the vent components.
manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS
WHILE HOT
.
21
Page 22
TROUBLESHOOTING THE MILLIVOLT CONTROL SYSTEM
Note: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and
wall switch, iff applicable), is in the “ON” position.
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
SYMPTOMPOSSIBLE CAUSESCORRECTIVE ACTION
1. Spark igniter will not light pilot after
repeated triggering of igniter button.
WARNING: if the pilot will not light
after 1 minute of attempting, wait
for at least 5 minutes for gas to
clear before attempting again.
2. Pilot will not stay lit after
carefully following the lighting
instructions.
3. Pilot burning, no gas to burner, Valve
knob “ON,” and the (standard) burner
OFF/ON switch is “ON." Read important note below.
IMPORTANT NOTE: If an optional
*remote switch is used for burner
operation, the unit-mounted burner
OFF/ON switch (if installed) must be
in the "OFF" position.
*Optional remote switch kits - wall
switch, wall thermostat or remote
control.
4. Frequent pilot/burner outage prob
lem.
-
A. Defective igniter
(no spark at electrode).
B. Defective or misaligned electrode at pilot
(spark at electrode).
C. Gas supply pressure errant.
D. Pilot orifice plugged.
A. Defective pilot generator
(thermocouple).
A. Wall switch or wires defective.
B. Thermopile may not be generating suf-
ficient millivolts.
C. Plugged burner orifice.
D. OFF/ON Switch & *Remote Switch are in
the "ON" position resulting in excessive
resistance.
A. Pilot flame may be too low or blowing (high)
causing the pilot/valve safety to drop out.
Check for spark at electrode and pilot; if no spark and
electrode wire is properly connected, replace igniter.
Using a match, light pilot. If pilot lights, turn off pilot
and trigger the igniter button again. If pilot lights, an
improper gas mixture caused the bad lighting and a
longer purge period is recommended. If pilot will not
light – check gap at electrode and pilot – should be
1/8" to have a strong spark. If gap does not measure
1/8", replace pilot (see Figure 12 on Page 12).
Check inlet gas pressure. It should be within the limits
as marked on the rating plate.
Clean or replace pilot orifice.
Check pilot flame, it must impinge on thermocouple
(see Figure 12 on Page 12). Clean and/or adjust pilot
for maximum flame impingement on thermocouple.
Ensure that the connection between the valve and
thermocouple are tight and secure.
Check wall switch and wires for proper connections.
Jumper wire across terminals at wall switch, if burner
comes on, replace defective wall switch. If okay, jumper
wires across wall switch wires at valve, if burner comes
on, wires are faulty or connections are bad.
Check thermopile with millivolt meter. Take reading
at thermopile terminals of gas valve. Should read
325 millivolts minimum with optional wall switch
“OFF.” Replace faulty thermopile if reading is below
specified minimum.
Check burner orifice for blockage and remove.
When turning on the burner using a *remote switch,
ensure that the standard OFF/ON switch is in the "OFF"
position. If both switches are in the ON position, it
may result in excessive resistance (& millivolt drainage) and the burner may not come on.
Clean and/or adjust pilot flame for maximum flame
impingement on thermocouple (see Figure 12 on
Page 12).
TROUBLESHOOTING GUIDE - ELECTRONIC IGNITION SYSTEM
SYMPTOMPOSSIBLE CAUSESCORRECTIVE ACTION
1. Burner will not light.A. Faulty Valve System.
B. “OFF/ON” or wall switch defective.
2. Burners come “ON,” then turns “OFF.”A. Burner orifice plugged.
22
B. Obstructed vent system.
See Below.
Disconnect the two black wires from the wire nuts.
Test switch(s) for continuity with a multimeter. If
continuity is not indicated, switch(s) is defective and
must be replaced.
Note: Before replacing “OFF/ON” switch, Ensure to
check wiring for loose connections or broken wires
and repair as needed.
Check main burner orifice(s) for blockage. Clean
or replace.
Check vent system for obstructions.
Page 23
1
2
2
121
TROUBLESHOOTING PROCEDURE - ELECTRONIC IGNITION SYSTEM
STARTCHECK
• Turn Off Gas Supply.
• Ensure Valve Switch Is In ON Position.
• Disconnect Control Harness.
• Set Thermostat To Call For Heat.
Insert A
End View of Control Harness Connector
• Check for proper voltage at control harness
(see insert A). Voltage
should be 24V between
thermostat or pressure
switch and 24V common
and 24V hot.
YES
• Plug control harness into
valve. Wait for internal check
delay.
NO
• Line voltage power
• Low voltage transformer
• Limit controller
• Thermostat
• Wiring
24 Volt Hot
24 Volt
Switched
Check For Damaged or Missing
Terminals in Connector
Insert B
Igniter Terminals
24 Volt
Common
• With pilot burner cable con-
• Igniter warms up and glows
red.
NO
nected, measure voltage at
valve HSI element output. 24V
nominal. (See insert B)
YES
YES• Replace igniter/flame rod
assembly.
YES
• Check that pilot gas is flowing. Wait
• Turn on gas supply.
• Pilot burner lights.
NO
to ensure pilot gas tubing is purged.
Recycle call for heat if necessary.
YES
• Measure voltage between 24V hot and
24V common leads to valve control.
Must measure at least 19.5 VAC with
igniter powered (see insert A). To
YES
identify proper lead, this check must
be done with the valve control connected and igniter powered.
YES
• Replace Pilot Assembly.
• Check that pilot flame makes good
contact with pilot burner flame rod.
• Main valve opens and main
burner lights.
• Check for good electrical connection
NO
through the pilot tubing.
• If both of the above are good, replace
igniter/flame rod assembly.
YES YES
• System Is okay.• Cycle thermostat off and back on.
NO
• Replace valve.
NO
• Replace valve.
• Check transformer and
NO
line volt supply.
Igniter will cycle off and
back on once during the 90
second ignition trial. All
voltage measurements must
When measuring voltage
at connections, use care
to ensure terminals are
not damaged.
• Main burner lights.
NO
• Replace valve.
be taken while the igniter is
powered.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
23
Page 24
REPLACEMENT PARTS LIST
MISC. COMPONENTS
Item Cat.No DescriptionQty.Where Used
1a98K95Hood, Black - 24 in.1SSDVPF
1b97K52Hood, Black - 40 in.2All Models
2aH3437Upper Louver Panel, Black
2bH3377Upper Louver Panel, Black
3aH3725Glass Enclosure Assembly
3bH3724Glass Enclosure Assembly
4aH3438
H3380* Lower Louver Panel, Black
4b
556L93Nameplate Logo (Brand)2All Models
669L62Log Set 1All Models
788L53Bag of Glowing Gas Embers 1All Models
880L42Bag of Decorative Volcanic
Contact an Authorized LHP dealer to obtain any of these parts. Never
use substitute materials. Use of non-approved parts can result in poor
performance and safety hazards.
24
WARNING
Failure to position the parts in accordance with these
diagrams or failure to use only parts specifically
approved with this appliance may result in property
damage or personal injury.
AVERTISSEMENT
Risque de dommages ou de blessures si les pièces
ne sont pas installées conformément à ces schémas
et ou si des pièces autres que celles spécifiquement
approuvées avec cet appareil sont utilisées.
Page 25
REPLACEMENT PARTS DIAGRAMS
Firebox
Cabinet
1a
2a
3a
4a
8
10a
10b
37
13a
31
30
13b
44
16
12
12
7
17
14
1b
3b
4b
5
2b
11
32
33
34
36
35
40
30
43
41
45
42
6
Note: Cabinet and Firebox
shown for reference only.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
25
Page 26
NOTES:
26
Page 27
NOTES:
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
27
Page 28
LHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor
for fireplace code information.