SunX EQ-34, EQ-34-PN, EQ-34W User guide

Thank you very much for using SUNX products. Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product. Kindly keep this manual in a convenient
INSTRUCTION MANUAL
place for quick reference.
Photoelectric Sensor
Adjustable Range Reflective
EQ-30 Series
٨٨Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use products which meet
WARNING
1
SPECIFICATIONS
Item
Adjustable range (Note 2)
Sensing range
with white non-glossy paper at setting distance 2m
Hysteresis
Current consumption
Output
Output operation Short-circuit protection
Operation indicator
Automatic interference prevention function
Emitting element
Cable 0.3mm23-core cabtyre cable, 2m long
Notes: 1) The model No. with suffix '-J' stands for the connector type. (EQ-34W is excluded.)
standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
Type
Model No. (Note 1)
(e.g.) As for the connector type of EQ-34 'EQ-34-J' Use the mating cables as shown below.
CN-24-C2 (Straight type, 4-core, 2m) CN-24-C5 (Straight type, 4-core, 5m)
The model No. with suffix '-C5' stands for the 5m cable length type. (EQ-34-PN is excluded.) (e.g.) As for the 5m cable length type of EQ-34 'EQ-34-C5'
2)
The adjustable range stands for the maximum sensing range which can be set with the adjuster. The sensor can detect an object 0.1m, or more, away. However, the detectable area of the Near (Sub) type of the EQ-34W begins at 0.2m.
NPN output type PNP output type Two outputs type
EQ-34
NPN open-collector transistor
Maximum sink current: 100mAApplied voltage: 30V DC or less
Residual voltage: 1V or less
(between output and 0V)
(at 100mA sink current)
0.4V or less
(at 16mA sink current)
Switchable either Detection-ON or Detection-OFF
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition) (Note 4)Stability indicator
2-turn mechanical adjuster with pointerDistance adjuster
Incorporated (Two units of sensors can be mounted close together.)
-20to+55 (No dew condensation or icing allowed), Storage: -25 to +70Ambient temperature
Enclosure: Polyalylate and Polyethylene terephthalate, Lens: PolyalylateMaterial
Adjustable range reflective
EQ-34-PN
0.2 to 2m
0.1 to 2m
10% or less of operation distance
10 to 30V DC Ripple P-P 10% or lessSupply voltage
PNP open-collector transistor
Maximum source current: 100mAApplied voltage: 30V DC or less
Residual voltage: 1V or less
35 to 85% RH, Storage: 35 to 85% RHAmbient humidity
(between output and +V)
(at 100mA source current)
0.4V or less
(at 16mA source current)
Incorporated
2msorlessResponse time
IP67 (IEC)Protection
Infrared LED (modulated)
2-segment photodiodeReceiving element
150g approx.Weight
Adjusting screwdriver: 1pc.Accessory
CN-24L-C2 (Elbow type, 4-core, 2m) CN-24L-C5 (Elbow type, 4-core, 5m)
Non-detectable range
Far (Main): 0.2 to 2m Near (Sub): Refer to diagram in (Note 3)
Far (Main): 0.1 to 2m Near (Sub): 0.2 to 2m [with Near (Sub) distance for adjuster at max.]
<Far (Main) output, Near (Sub) output> NPN open-collector transistor
Maximum sink current: 100mAApplied voltage: 30V DC or less
Residual voltage: 1V or less
Far (Main) output: Red LED
[lights up when the Far (Main) output is ON]
Near (Sub) output: Red LED
[lights up when the Near (Sub) output is ON]
Far (Main): 2-turn mechanical ad­juster with pointer Near (Sub): Variable adjuster
0.3mm24-core cabtyre cable, 2m long
EQ-34W
90mA or less55mA or less50mA or less
(between output and 0V)
(at 100mA sink current)
(at 16mA sink current)
Actual sensing
0.1m range of the sensor
0.2m
Adjustable range
0.4V or less
2m
Sensing object
2
CAUTIONS
٨
٨
Take care that wrong wiring will damage the sensor.
٨
Verify that the supply voltage variation is within the rating.
٨
If power is supplied from a commercial switch­ing regulator, ensure that the frame ground (F.G.) terminal of the power supply is connect­ed to an actual ground. In case noise generating equipment (switching
٨
regulator, inverter motor, etc.) is used in the vicini­ty of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. Do not run the wires together with high-voltage
٨
lines or power lines or put them in the same race­way. This can cause malfunction due to induction. Extension up to total 100m, is possible with
٨
2
, or more, cable. However, in order to re-
0.3mm duce noise, make the wiring as short as possible. Do not use during the initial transient time
٨
(50ms) after the power supply is switched on. Take care that the sensor is not directly exposed
٨
to fluorescent lamp from a rapid-starter lamp, a high frequency lighting device or sunlight etc., as it may affect the sensing performance. Avoid dust, dirt, and steam. Do not use it in
٨
places having excessive vapor, dust, etc., or where it may come in direct contact with corrosive gas. Take care that the sensor does not come in di-
٨
rect contact with water, oil, grease, organic sol­vents, such as, thinner etc., or strong acid, and alkaline. Make sure that stress by forcible bend or pulling
٨
is not applied directly to the sensor cable joint. Since the cable end is not waterproof, do not
٨
use the sensor in the application where water may seep in from the cable end. When connecting the mating cable to the
٨
connector type sensor, the tightening torque should be 0.4Nmorless.
3
MOUNTING
٨ The tightening torque should be 0.8N㨯mor
less.
M4 nut
M4 (length 25mm) screw with washers
Sensor mounting bracket
MS-EQ3-2
(Optional)
٨ Care must be taken regarding the sensor
mounting direction with respect to the object's direction of movement.
Good
Good
No good
3)
The Near (Sub) distance adjustable range, L2, changes with the setting of the Far (Main) distance, L1, as shown in the table below.
EQ-34W Near (Sub) distance adjustable range
Near (Sub) distance adjustable range
2 (m)
L
4) Refer to ' STABILITY INDICATOR' for the details of the stability indicator.
6
2
1.5
1
0.5
0 0.5 1 1.5 2
Far (Main) setting distance L
Far (Main) setting distance L
1 (m)
EQ-34W
2m 1to2m
1.5m 0.85 to 1.5m 1m 0.65 to 1m
0.5m 0.35 to 0.5m
0.2m 0.2m
1
Near (Sub) distance adjustable range L
2
Sensing object
Sensing object
Sensing object
Do not make the sen­sordetectanobject in this direction be­cause it may cause unstable operation.
٨٨When detecting a specular object (aluminum or
copper foil, etc.) or an object having a glossy surface or coating, please take care that there are cases when the object may not be detected due to a small change in angle, wrinkles on the object surface, etc. When a specular body is present below the sensor, use the sensor by tiling it slightly up­wards to avoid wrong operation.
No good
Specular face
Good
Specular face
Tilt
٨٨If a specular body is present in the background,
wrong operation may be caused due to a small change in the angle of the background body. In that case, install the sensor at an inclination and confirm the operation with the actual sens­ing object. Some object may produce the dead zone right in front of the sensor.
4
I/O CIRCUIT DIAGRAMS
٨ NPN output type / EQ-34
Color code / Connector pin No.
D
of the connector type
(Brown / 1) +V
Load
Black / 4) Output
Sensor circuit
(
r
T
100mA max.
ZD
(Blue / 3) 0V
+
-
10 to 30V DC
Internal circuit Users' circuit
Symbols...D
: Reverse supply polarity protection diode
D
Z
: Surge absorption zener diode
Tr
: NPN output transistor
٨ PNP output type / EQ-34-PN
Color code / Connector pin No. of the connector type
(Brown / 1)+V
ZD
Sensor circuit
T
r
100mA max.
(Black / 4) Output
oad
L
(Blue/3)0V
+
-
10 to 30V DC
D
Internal circuit Users' circuit
Symbols...D
: Reverse supply polarity protection diode
D
Z
: Surge absorption zener diode
Tr
: PNP output transistor
٨ Two outputs type / EQ-34W
ZD1
ZD2
Color code
(Brown)+V
k) Far
(Blac
(Main)output
100mA max. e) Near (Sub) output
(Whit
(Blue)0V
2
3
0V
Load
100mA max.
1
+V
Output
Load
+
-
10 to 30V DC
D
T
r1
Tr2
Sensor circuit
Internal circuit Users' circuit
Symbols...D: , Reverse supply polarity protection diode
٨
D1,ZD2: Surge absorption zener diode
Z
r1,Tr2: NPN output transistor
T
Connector pin position of the connector type
Not connected
5
AUTOMATIC INTERFERENCE PREVENTION FUNCTION
٨ EQ-30 series is incorporated with automatic
interference prevention function. Up to two sets of sensors can be installed close together.
Close mounting of two sensors
6
STABILITY INDICATOR
٨
Since the EQ-30 series uses a 2-segment pho­todiode as its receiving element, and sensing is done based on the difference in the incident beam angle of the reflected beam from the sensing object, the output and the operation in­dicator operate according to the object distance. Further, the stability indicator shows the margin of the incident light intensity and not that of the object distance. Hence, the distance at which it lights up/off de­pends on the object reflectivity and is not at all related to the output operation. Do not use the sensor when the stability indicator is off (unsta­ble light received condition), since the sensing will be unstable.
Sensor
Setting distance
Sensing
Sensing
object
Output (operation indicator) (In case of Detection-ON)
Stability indicator (Black non-glossy paper)
Stability indicator (White non-glossy paper)
7
DISTANCE ADJUSTMENT
Unstable light received condition
Stable light received condition
Stable light received condition
Sensing
object
object
Stable dark condition
Unstable light received condition
Stable dark condition
ON (Lights up)
OFF (Turns off)
Lights up
Turns off
Lights up
Turns off
EQ-34, EQ-34-PN
٨ Top-view
Distance adjuster
Adjuster indicator
Shows how much the distance adjust­er is rotated.
Operation indicator (Red)
Lights up when the output is ON.
NEAR
(2-turn)
The sensing range increases as it is turned clockwise.
Operation mode switch
FAR
L: Detection-ON D: Detection-OFF (Turn the switch fully.)
L
D
Stability indicator (Green)
Lights up under stable light received condition or stable dark condition.
٨ Adjusting procedure
Step
Turn the distance adjuster fully counter­clockwise to the minimum sensing range
Ԙ
position of 0.2m approx.
Place an object at the required distance from the sensor, turn the distance adjuster gradually clockwise, and find out point
ԙ
where the sensor changes to the light re­ceived condition.
Remove the object, turn the distance ad­juster further counterclockwise, and find out point where the sensor changes to the light received condition again with only the background.
Ԛ
When the sensor does not go to the light received condition even if the adjuster is fully turned clockwise, point is this ex­treme point in the range.
The optimum position to stably detect ob-
ԛ
jects is the center point between and .
Note: Use the accessory adjuster screwdriver to turn the distance
adjuster slowly. Turning with excessive force will cause dam­age the adjuster.
Description
Distance adjuster
NEAR
FAR
Turn fully
A
NEAR
FAR
A
B
NEAR
FAR
A
Optimum position
B
NEAR
FAR
EQ-34W
٨ Top-view
MAIN
STB
FAR
MODE
DL
Far (Main) distance adjuster (2-turn)
The sensing range increases as it is turned clockwise.
Operation mode switch
L: Detection-ON D: Detection-OFF (Turn the switch fully.)
Far (Main) output operation indicator (Red)
Lights up when the Far (Main) output is ON.
Far (Main) adjuster indicator
Shows how much the dis­tance adjuster is rotated.
Near (Sub) distance adjuster
The sensing range increas­es as it is turned clockwise.
Near (Sub) output operation indicator (Red)
Lights up when the Near (Sub) output is ON.
Stability indicator (Green)
Lights up under stable light received condition or stable dark condition.
NEAR
SUB
SUB MAIN
٨࡮Adjusting procedure
Far (Main) side
Step
Turn the Far (Main) distance adjuster fully counterclockwise to the minimum
Ԙ
sensing range position of 0.2m approx.
Place an object at the far place at the re­quired distance from the sensor, turn the Far (Main) distance adjuster gradually clock-
ԙ
wise, and find out point where the sensor changes to the light received condition.
Remove the object, turn the Far (Main) distance adjuster further clockwise, and find out point where the sensor changes to the light received condition again with only the background.
Ԛ
When the sensor does not go to the light received condition even if the ad­juster is fully turned clockwise, point is this extreme point in the range.
The optimum position to stably detect objects for the Far (Main) setting is the
ԛ
center point between and .
Description
Distance adjuster
NEAR
FAR
MAIN
Turn fully
A
NEAR
FAR
MAIN
A
NEAR
FAR
MAIN
B
A
Optimum
MAIN
position
FAR
B
NEAR
Near (Sub) side
Step
Turn the Near (Sub) distance adjuster fully counterclockwise to the minimum
Ԙ
sensing range point.
Place an object at the near position, at the required distance from the sensor, turn the Near (Sub) distance adjuster
ԙ
gradually clockwise, and find out point
where the sensor changes to the light
received condition.
Remove the object from the near posi­tion, and place the object for Far (Main) sensing at the sensing position. Turn the Near (Sub) distance adjuster further clockwise, and find out point where the sensor changes to the light received con-
Ԛ
dition again with only the background.
When the sensor does not go to the light received condition even if the ad­juster is fully turned clockwise, point is this extreme point in the range.
The optimum position to stably detect objects for the Near (Sub) setting is the
ԛ
center point between and .
Notes: 1)2)Use the accessory adjuster screwdriver to turn the dis-
tance adjuster slowly. Turning with excessive force will cause damage the adjuster. The Far (Main) distance adjustment should be done before the Near (Sub) distance adjustment. Take care that the Near (Sub) setting distance changes with change in the Far (Main) setting distance.
EQ-34W
Description
Near (Sub) setting distance
Near object Far object
Far (Main) output
In case of Detection-ON
Near (Sub) output
In case of Detection-OFF
Far (Main) distance adjustable range
(0.2 to 2m)
Near (Sub) distance adjustable range
Distance adjuster
SUB
Turn fully
SUB
SUB
SUB
Far (Main) setting distance
Near (Sub) dis­tance adjuster set at the maximum.
C
C
D
C
Optimum position
D
ON
OFF
ON
OFF
SUNX Limited
Head Office
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-(0)568-33-7211 FAX: +81-(0)568-33-2631
Overseas Sales Dept.
Phone: +81-(0)568-33-7861 FAX: +81-(0)568-33-8591
http://www.sunx.co.jp/
PRINTED IN JAPAN