![](/html/08/089d/089dd9d8081393e2ad0dd92ea38b41de80c5f98fe4d58ebad460646a6e6a4046/bg1.png)
䢇 This product is not a safety sensor. Its use is not
intended or designed to protect life and prevent body
injury or property damage from dangerous parts of
machinery. It is a normal pressure detection sensor.
䢇 In case this sensor is used within Japan, SI unit most
be used since use of pressure units in Japan is
restricted to SI units.
Gauge pressure
0 to
ⳮ101.3kPa 0 to 100.0kPa 0 to 1.000MPa
5.1 to
ⳮ101.3kPa ⳮ5.0 to 100.0kPa ⳮ0.050 to 1.000MPa
490kPa 1.47MPa
Non-corrosive gas
kgf/cm
2
, bar, psi, mmHg, inHg kgf/cm2, bar, psi
12 to 24V DC % Ripple P-P 10% or less
50mA or less
<Asian, North American (Standard NPN output • Flat • IP67 types)>
NPN open-collector transistor
• Maximum sink current: 100mA
•
Applied voltage: 30V DC or less (between comparative output and 0V)
• Residual voltage: 1V or less (at 100mA sink current)
0.4V or less (at 16mA sink current)
Equipped with 4 types of modes: hysteresis mode, window comparator mode, dual output mode, automatic sensitivity
setting mode (selectable by key operation)
1 digit (However, variable in hysteresis mode and 2 digits when using psi unit)
Within
Ⳳ0.2% F.S.Ⳳ1 digit
2.5ms or less
Incorporated
Output voltage: 1 to 5V (over rated pressure range)
Zero-point: within 1VⳲ5% F.S.
Span: within 4V
Ⳳ5% F.S.
Linearity: within
Ⳳ1% F.S.
Output impedance: 1kΩ approx.
3
1
/2 digit red LED display (Sampling rate: 4 times/sec. approx.)
5.1 to
ⳮ101.3kPa ⳮ5.0 to 100.0kPa ⳮ0.050 to 1.000MPa
LED bar display in steps of 10% F.S. approx.
Orange LED (lights up when Comparative Output 1 is ON)
Green LED (lights up when Comparative Output 2 is ON)
Standard • Flat • Light weight types: IP40 (IEC), IP67 type: IP67 (IEC)
ⳮ10 toⳭ50⬚C (No dew condensation or icing allowed), Storage: ⳮ10 toⳭ60⬚C
35 to 85% RH, Storage: 35 to 85% RH
Over ambient temperature range
ⳮ10 toⳭ50⬚C: withinⳲ1% F.S. of detected pressure at 20⬚C
Standard • Flat • IP67 types: Rc (PT)
1
/8 female thread, Light weight type: M5 female thread
Standard type: NPTF
1
/8 female thread, Flat • IP67 types: NPT
1
1
/8 female thread
Flat • IP67 types: G (PF)
1
/8 female thread
Front case: ABS, Rear case: PPS (glass fiber reinforced), Display surface: Acrylic
Pressure port attachment: Die-cast zinc alloy [Light weight type: POM (glass fiber reinforced), pressure port is brass (nickel plated)]
Front cover (IP67 type only): Polycarbonate
0.15mm
2
5-core oil resistant cabtyre cable, 2m long (IP67 type: 5m long)
Extension up to total 100m is possible with 0.3mm
2
, or more, cable.
Standard type: 95g approx., Flat type: 120g approx., IP67 type: 370g approx., Light weight type: 70g approx.
Hexagon-socket-head plug for pressure port: 1 No. (Standard type only), Pressure unit label: 1 No.
5
1
Pressure
Output voltage (V)
High pressure
(Positive pressure type)
High vacuum
(Vacuum pressure type)
INSTRUCTION MANUAL
LED Display • Digital Pressure Sensor
DP2 Series
For use outside Japan
Thank you very much for using SUNX sensors. Please read
this Instruction Manual carefully and thoroughly for the
correct and optimum use of this sensor. Kindly keep this
manual in a convenient place for quick reference.
1
SPECIFICATIONS
Type of pressure
Rated pressure range
Set pressure range
Pressure withstandability
Applicable fluid
Selectable units
Supply voltage
Current consumption
Comparative outputs
Comparative Output 1
Comparative Output 2
Output modes
Hysteresis
Repeatability
Response time
Short-circuit protection
Analog voltage output
Display
Displayable pressure range
Analog bar display
Comparative Output 1
Comparative Output 2
Protection
Ambient temperature
Ambient humidity
Temperature characteristics
Asian
North American
European
Material
Cable
Cable extension
Weight
Accessories
Operation
indicators
Pressure
port
<North American (Standard PNP output type), European>
PNP open-collector transistor
• Maximum source current: 100mA
•
Applied voltage: 30V DC or less (between comparative output and ⳭV)
• Residual voltage: 2V or less (at 100mA source current)
Ⳮ10
ⳮ15
Type
Asian
North American (Note)
European
Vacuum pressure Positive pressure
ⳮ101kPa type 100kPa type 1MPa type
Standard Flat IP67
Light weight
Standard Flat IP67 Standard Flat IP67
DP2-20 DP2-60 DP2-80 DP2-21 DP2-41 DP2-61 DP2-22 DP2-42 DP2-62
DP2-20F(-P)
DP2-40N DP2-60N
DP2-21F(-P)
DP2-41N DP2-61N
DP2-22F(-P)
DP2-42N DP2-62N
DP2-40E DP2-60E DP2-41E DP2-61E DP2-42E DP2-62E
Item
Model No.
2
CAUTIONS
DP2 series is designed for use with non-corrosive gas.
It cannot be used for liquid or corrosive gas.
䢇 Use within the rated pressure range.
䢇 Do not apply pressure exceeding the pressure
withstandability value. The diaphragm will get damaged and
correct operation shall not be maintained.
䢇 Make sure to carry out the wiring in the power supply off
condition.
䢇 Take care that wrong wiring will damage the sensor.
䢇 Verify that the supply voltage variation is within the rating.
䢇 If power is supplied from a commercial switching regulator,
ensure that the frame ground (F.G.) terminal of the power
supply is connected to an actual ground.
䢇 In case noise generating equipment (switching regulator,
inverter motor, etc.) is used in the vicinity of this sensor,
connect the frame ground (F.G.) terminal of the equipment to
an actual ground.
䢇 Do not use during the initial transient time (0.5 sec.) after the
power supply is switched on.
䢇
Do not run the wires together with high-voltage lines or power
lines or put them in the same raceway. This can cause malfunction due to induction.
䢇 Cable extension, using 0.3mm2, or more, cable, should be
100m or less overall.
䢇 Avoid use of standard type, flat type and light weight type of
sensor in places where steam and dust is excessive.
䢇 Take care that the sensor does not come in direct contact
with water, oil, grease, or organic solvents, such as, thinner,
etc.
䢇 Do not insert wires, etc, into the pressure port. The
diaphragm will get damaged and correct operation shall not
be maintained.
䢇 Do not operate the keys with pointed or sharp objects.
3
SETTING OF PRESSURE LEAD
DIRECTION AND PIPING
Standard type
䢇 Setting of pressure lead direction
• The pressure lead direc-
tion can be changed by
dismantling the pressure
port attachment and
changing the mounting
direction. The tightening
torque of the hexagonsocket-head bolt (length
9mm or less) should be
0.29N䡠m or less.
Note: Please make sure to close any unused pressure port with
the hexagon-socket-head plug supplied as accessory.
Flat type, Light weight type
䢇 Setting of pressure lead direction
• The pressure lead direction can be changed by dismantling
the pressure port attachment and changing the mounting
direction. The tightening torque of the hexagon-socket-head
bolt (length 9mm or less) should be 0.29N䡠m or less.
䢇 Piping
•
When connecting a coupling to the pressure port,
hold the pressure port
attachment with a 16mm
(Light weight type: 10mm)
spanner and make sure that
the tightening torque is
9.8N䡠m or less (Light weight
type: 1.47N䡠m or less). Also, in order to prevent any leakage,
wind a sealing tape on the coupling when connecting.
Hexagon-sockethead bolts
2-"4.3mm mounting holes
Pressure port
Pressure port attachment
Main body
16mm
(light weight type: 10mm)
spanner
Hexagonsockethead bolts
Main body
Pressure port
attachment
Hexagon-sockethead plug
Pressure
ports
䢇 Piping
• When connecting a
hexagon-socket-head plug
or coupling to the pressure
port, hold the hexagonal
part of the pressure port
with a 12mm spanner and
make sure that the
tightening torque is 9.8N䡠m
or less. Also, in order to prevent any leakage, wind a sealing
tape on the coupling when connecting.
However, sealing tape is not required for North American type
using NPTF 1/8 coupling. (Sealing tape is required if NPT1/8
coupling is used.)
IP67 type
䢇 Piping for pressure measurement inlet port
• When connecting a coupling to the pressure measurement
inlet port, hold the pressure port attachment with a spanner
and make sure that the tightening torque is 9.8N䡠m or less.
Also, in order to prevent any leakage, wind a sealing tape on
the coupling when connecting.
䢇 Piping for atmospheric pressure inlet port
• If there is a possibility of
water entering into the
sensor enclosure through
the atmospheric pressure
inlet port, connect a tube to
the atmospheric pressure
inlet port through a M5
coupling and extend the
other end of the tube to a
safe place. In this case,
ensure that this end of the
tube does not get clogged.
䢇 Fitting of front cover
• Insert the bosses on the front cover into the guide holes at
the bottom of the pressure port attachment, and push in the
direction of the arrow to fit the hook.
When removing the front cover, release the hook first.
Atmospheric
pressure inlet port
Pressure measurement
inlet port
Tube
M5 coupling
Safe place,
where there is no
exposure to water
()
For use outside Japan
Note: Model Nos. of North American standard type having the suffix ‘-P’ are PNP output type.
MJE-DP2 No.0580-05
![](/html/08/089d/089dd9d8081393e2ad0dd92ea38b41de80c5f98fe4d58ebad460646a6e6a4046/bg2.png)
4
MOUNTING OF STANDARD TYPE SENSOR
䢇 A sensor mounting bracket MS-DPX and MS-DPX-4
(optional) may be used.
When mounting the sensor with the sensor mounting bracket,
etc., the tightening torque should be 1.2N·m or less.
䢇 Panel mounting bracket MS-DPX-2 (optional) and a front
protection cover DPX-04 (optional) are also available.
5
I/O CIRCUIT DIAGRAM
NPN output type
Tr2
Tr1
1kΩ
100mA max.
100mA max.
Users’ circuitInternal circuit
(Blue) 0V
(White) Comparative Output 2
(Black) Comparative Output 1
(Gray) Analog
voltage output
(Brown)
ⳭV
Color code
Load
Load
ZD2
ZD3
ZD1
D
12 to 24V DC
%
Ⳮ
ⳮ
Sensor circuit
Ⳮ10
ⳮ15
(Note)
Sensor mounting bracket
MS-DPX (optional)
M4 (length 6mm) pan head screw
(attached with MS-DPX)
Spring washer
(attached with MS-DPX)
D
P
2
-
2
0
–
1
0
1
.
3
k
P
a
O
U
T
2
O
U
T
1
M
O
D
E
0
A
D
J
Panel mounting bracket
MS-DPX-2 (optional)
(Suitable for 1 to 3.2mm thick panel)
D
P
2
2
0
–
1
0
1
.
3
k
P
a
O
U
T
2
O
U
T
1
M
O
D
E
0
-
A
D
J
Front protection cover
DPX-04 (optional)
Symbols…D: Reverse supply polarity protection diode
Z
D1, ZD2, ZD3: Surge absorption zener diode
Tr
1, Tr2: NPN output transistor
Note: The analog voltage output is not incorporated with a short-circuit
protection circuit. Do not directly connect a power supply or a
capacitive load. When using the analog voltage output, take
care to connect external equipment of proper input impedance.
Also, when a cable extension is used, voltage drop due to cable
resistance should be taken into account.
PNP output type
Users’ circuitInternal circuit
Color code
100mA max.
100mA max.
ZD1
ZD2
ZD3
Tr1
Load
Load
(Brown)ⳭV
(White) Comparative Output 2
(Black) Comparative Output 1
(Gray) Analog
voltage output (Note)
(Blue) 0V
12 to 24V DC
%
Ⳮ
ⳮ
Tr2
D
Sensor circuit
1kΩ
Ⳮ10
ⳮ15
Symbols…D: Reverse supply polarity protection diode
Z
D1, ZD2, ZD3: Surge absorption zener diode
Tr
1, Tr2: PNP output transistor
Note: The analog voltage output is not incorporated with a short-circuit
protection circuit. Do not directly connect a power supply or a
capacitive load. When using the analog voltage output, take
care to connect external equipment of proper input impedance.
Also, when a cable extension is used, voltage drop due to cable
resistance should be taken into account.
6
FUNCTIONAL DESCRIPTION OF
OPERATION PANEL
DP2-20
–101.3kPa
OUT2OUT1
MODE
0-ADJ
1
2
3
6
4
5
06H0129
Description Function
1
2
3
4
5
6
31/2 digit LED
display (Red)
Comparative Output 1
operation indicator
(Orange)
Comparative Output 2
operation indicator
(Green)
Increment key
()
Decrement key
()
Mode selection key
()
Displays measured pressure, settings, error messages and key-protect status.
Lights up when Comparative Output 1 is ON.
Lights up when Comparative Output 2 is ON.
• In the initial setting mode, pressing the
key changes the settable digit.
• In the Set Value 1, 2 modes, pressing
the key changes the set value to the
high pressure side in case of positive
pressure type sensor and to the high
vacuum side in case of vacuum pressure
type sensor.
•
In the sensing mode, if the key is pressed
continuously for 4 sec. or more, the display
shows peak hold value.
• In the initial setting mode, pressing the
key changes the set conditions.
• In the Set Value 1, 2 modes, pressing
the key changes the set value to the
low pressure side in case of positive
pressure type sensor and to the low
vacuum side in case of vacuum pressure
type sensor.
•
In the sensing mode, if the key is pressed
continuously for 4 sec. or more, the display
shows bottom hold value.
• Pressing the key changes the selected mode to
sensing mode, Set Value 1 (P1) set mode and Set
Value 2 (P2) set mode.
• In the sensing mode, if the key is pressed continuously for about 3 sec., key-protect can be
set/released.
• In the sensing mode, if the mode selection key is
pressed while pressing the increment key ( ) , the
initial setting mode is obtained.
In the sensing mode, if both the keys are pressed
simultaneously, zero-point adjustment is done.
7
ERROR MESSAGES
䢇 When an error occurs, take the following corrective action.
Error message Cause Corrective action
Overcurrent due to shortcircuit.
Pressure is being applied
during zero-point adjustment.
Positive
pressure
type
Vacuum
pressure
type
Positive
pressure
type
Vacuum
pressure
type
Applied pressure exceeds
the upper limit of displayable pressure range.
Applied pressure exceeds
the lower limit of displayable pressure range.
Applied pressure exceeds
the lower limit of displayable pressure range.
Applied pressure exceeds
the upper limit of displayable pressure range
.
Switch off the power supply
and check the load.
Applied pressure should be
brought within the rated
pressure range.
Applied pressure at the
pressure port should be
brought to atmospheric
pressure and zero-point
adjustment should be done
again.
8
ANALOG BAR DISPLAY
䢇
Pressure changes are displayed in an analog fashion by using LED bars.
Hence, any sudden changes in pressure can be detected at a glance.
䢇
The analog bar display shows the measured pressure, irrespective
of the pressure unit, in steps of 10% F.S. approx.
• Please refer to SETTING
2
Initial setting for the
procedure to change to analog bar display.
11
Analog bar display for positive pressure type sensor
Atm. pressure condition
Atm. pressure condition
High pressure condition
High vacuum condition
DP2-21
100kPa
OUT2OUT1
MODE
0-ADJ
DP2-21
100kPa
OUT2OUT1
MODE
0-ADJ
DP2-21
100kPa
OUT2OUT1
MODE
0-ADJ
06H0132
DP2-20
–101.3kPa
OUT2OUT1
MODE
0-ADJ
DP2-20
–101.3kPa
OUT2OUT1
MODE
0-ADJ
DP2-20
–101.3kPa
OUT2OUT1
MODE
0-ADJ
9
OUTPUT MODES & THEIR CHARACTERISTICS
Hysteresis mode ( )
䢇 The common hysteresis of the comparative outputs can be
set, as desired, with the set values.
Window comparator mode ( )
䢇
The comparative outputs can be turned ON or OFF by a pressure
which is within the pressure range set by Set Value 1 and Set Value 2.
Comparative
Output 1
Comparative
Output 2
ON
OFF
ON
OFF
0
Set Value 1 (P1) Set Value 2 (P2)
High pressure
(Positive pressure type)
High vacuum
(Vacuum pressure type)
Hysteresis
()
Hysteresis: 1 digit or more
2 digits or more when
using psi unit
Comparative
Output 1
Comparative
Output 2
ON
OFF
ON
OFF
0
Set Value 1 (P1)
Set Value 2 (P2)
High pressure
(Positive pressure type)
High vacuum
(Vacuum pressure type)
Hysteresis Hysteresis
Hysteresis: 1 digit
2 digits when
using psi unit
()
Comparative
Output 1
Comparative
Output 2
ON
OFF
ON
OFF
0
Set Value 1 (P1) Set Value 2 (P2)
High pressure
(Positive pressure type)
High vacuum
(Vacuum pressure type)
Hysteresis: 1 digit
2 digits when
using psi unit
Hysteresis
()
Dual output mode ( )
䢇 The outputs can be put to different use such as detection of
different kinds of objects, control function, alarm function etc.
Comparative
Output 1
Comparative
Output 2
ON
OFF
ON
OFF
0
Set Value 1 (P1) Set Value 2 (P2)
Set Value 3 (P3)
High pressure
(Positive pressure type)
High vacuum
(Vacuum pressure type)
Hysteresis
Hysteresis: 1 digit
2 digits when
using psi unit
()
Automatic sensitivity setting mode ( )
䢇 Using actual objects, if the pressure values for OK objects
and NG objects are input, then the sensor is automatically set
to the optimum pressure value (mid-value).
10
PRESSURE UNITS
䢇 The pressure unit can be selected as per customer’s
requirement.
䢇 In case of positive pressure type, the pressure unit can be
changed from International System of Units (SI) ‘kPa’ or
‘MPa’ to ‘kgf/cm
2
’, ‘bar’ or ‘psi’. In case of vacuum pressure
type, the pressure unit can be changed from International
System of Units (SI) ‘kPa’ to ‘kgf/cm
2
’, ‘bar’, ‘psi’, ‘mmHg’ or
‘inHg’.
•
When the pressure unit is changed, the set values and the
measured value are automatically converted.
• Please refer to SETTING
2
Initial setting for the
procedure to change the pressure unit.
11
inHg
kPa (Note)
kgf/cm
2
mmHg psi bar
: Positive pressure type: Vacuum pressure type
International System
of Units (SI)
• When operating in window comparator mode ( ) Set Value
1 (P1) and Set Value 2 (P2) should be set with a difference
of 3 digits or more. However, when the pressure unit is set
to ‘psi’, the difference should be 6 digits or more.
Note: MPa in case of DP2-22䡺, DP2-42䡺 and DP2-62䡺.
Analog bar display for vacuum pressure type sensor
Sensor mounting
bracket
MS-DPX-4 (optional)
M4 (length 6mm) pan head screw
(attached with MS-DPX-4)
Spring washer
(attached with MS-DPX-4)
Note: In case mounting brackets or screws other than the sensor
mounting bracket shown in the fiqure above are used, the length
of the screws inserted into the pressure port attachment should
be 5mm or less. If the length of the screws is longer than 5mm,
the sensor may be damaged.
<MS-DPX-4>
<
MS-DPX>