Sun Microsystems, Inc.
4150 Network Circle
Santa Clara, CA 95054 U.S.A.
650-960-1300
Part No. 816-3221-12
June 2004, Revision A
Submit comments about this document at: http://www.sun.com/hwdocs/feedback/
Copyright 2004Sun Microsystems, Inc., 4150 Network Circle, SantaClara, Ca.95054 U.S.A. All rights reserved.
This product or document is distributed under licenses restrictingits use,copying, distribution, and decompilation. No part of this product or
document maybe reproduced inany formby anymeans withoutprior writtenauthorization of Sun and its licensors, if any.Third-party
software, including font technology,is copyrightedand licensedfrom Sun suppliers.
Parts ofthe product may be derived from BerkeleyBSD systems,licensed from the University of California. UNIX is a registered trademarkin
the U.S.and othercountries, exclusivelylicensed through X/Open Company, Ltd.
Sun, SunMicrosystems, the Sun logo, docs.sun.com, OpenBoot, ShowMe How, Sun Blade, and Solaris are trademarks,registered trademarks,
or servicemarks ofSun Microsystems, Inc. in the U.S. and other countries.All SPARCtrademarks are usedunder licenseand are trademarksor
registered trademarks of SPARCInternational, Inc.in theU.S. andother countries.Products bearing SPARC trademarks are based upon an
architecture developed by Sun Microsystems, Inc.
The OPENLOOK andSun™ GraphicalUser Interfacewas developedby SunMicrosystems, Inc. for its users and licensees. Sun acknowledges
the pioneeringefforts of Xerox in researchingand developingthe conceptof visualor graphicaluser interfacesfor thecomputer industry. Sun
holds anon-exclusive licensefrom Xerox to the Xerox Graphical User Interface, which license also covers Sun’s licensees who implement OPEN
LOOK GUIsand otherwisecomply withSun’s writtenlicense agreements.
Federal Acquisitions:Commercial Software—Government Users Subject to Standard License Terms andConditions.
DOCUMENTATION IS PROVIDED “AS IS” AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT,
ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
Ce produit ou document est distribué avec des licences qui en restreignent l’utilisation, la copie, la distribution, et la décompilation. Aucune
partie dece produit ou document ne peut êtrereproduite sous aucune forme, par quelque moyen que ce soit, sans l’autorisation préalable et
écrite deSun etde sesbailleurs delicence, s’ily ena. Lelogiciel détenupar destiers, etqui comprend latechnologie relative aux polices de
caractères, est protégé par un copyright et licencié par des fournisseurs de Sun.
Des partiesde ceproduit pourront être dérivées des systèmes Berkeley BSD licenciés par l’Université de Californie. UNIX est une marque
déposée auxEtats-Unis etdans d’autres pays et licenciée exclusivement par X/Open Company, Ltd.
Sun, SunMicrosystems, le logo Sun, docs.sun.com, OpenBoot, ShowMe How, Sun Blade, et Solaris sont des marques defabrique oudes
marques déposées, ou marques de service, de Sun Microsystems, Inc. aux Etats-Unis et dans d’autrespays. Toutes les marques SPARC sont
utilisées souslicence etsont desmarques de fabrique ou des marques déposées de SPARC International, Inc.aux Etats-Uniset dansd’autres
pays. Lesproduits portant les marques SPARC sont baséssur unearchitecture développée par Sun Microsystems, Inc.
L’interfaced’utilisation graphiqueOPEN LOOKet Sun™a étédéveloppée parSun Microsystems, Inc.pour sesutilisateurs etlicenciés. Sun
reconnaît les efforts de pionniers de Xerox pour la recherche et le développement du concept des interfaces d’utilisation visuelle ou graphique
pour l’industriede l’informatique.Sun détientune licencenon exclusivede Xerox sur l’interface d’utilisation graphique Xerox, cette licence
couvrant égalementles licenciésde Sunqui mettenten placel’interface d’utilisationgraphique OPENLOOK etqui enoutre se conforment aux
licences écritesde Sun.
Achats fédéraux: logicielcommercial - Les utilisateurs gouvernementaux doivent respecter les conditions du contrat de licence standard.
LA DOCUMENTATION EST FOURNIE “EN L’ETAT” ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES
OU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PARLA LOI APPLICABLE, Y COMPRIS NOTAMMENT
TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE, A L’APTITUDE A UNE UTILISATION PARTICULIERE OU A
L’ABSENCE DE CONTREFAÇON.
Please
Recycle
Contents
Regulatory Compliance Statementsv
Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu CPU Module
Installation Guide1
Installation Kit Contents1
Rules for Installing Cu CPU Modules2
Sun Blade 1000 Workstation Configuration Rules3
Sun Blade 2000 Workstation Configuration Rules3
Identifying Cu CPU Modules3
Identifying a CPU Module3
OpenBoot PROM and Software Requirements for UltraSPARC III Cu CPU
Modules5
Installing the UltraSPARC III Cu CPU Module5
Verifying Software and Hardware Compatibility5
Preparing for Installation6
Powering Off the Workstation6
Verifying Power Off7
Removing the Access Panel9
Attaching the Disposable Antistatic Wrist Strap11
CPU Module Positions in the Workstation12
Removing a CPU Module13
iii
Installing a New CPU Module17
Finishing the Installation25
Where to Find More Information26
ivSun Blade 1000 and Sun Blade 2000 UltraSPARCTM III Cu Module Installation Guide • June 2004
Regulatory Compliance Statements
Your Sun product is marked to indicate its compliance class:
•Federal Communications Commission (FCC) — USA
•Industry Canada Equipment Standard for Digital Equipment (ICES-003) - Canada
•Voluntary Control Council for Interference (VCCI) — Japan
•Bureau of Standards Metrology and Inspection (BSMI) — Taiwan
Please read the appropriate section that corresponds to the marking on your Sun product before attempting to install the
product.
FCC Class A Notice
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if it is
not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required
to correct the interference at his own expense.
Shielded Cables: Connections between the workstation and peripherals must be made using shielded cables to comply
with FCC radio frequency emission limits. Networking connections can be made using unshielded twisted-pair (UTP) cables.
Modifications: Any modifications made to this device that are not approved by Sun Microsystems, Inc. may void the
authority granted to the user by the FCC to operate this equipment.
FCC Class B Notice
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced radio/television technician for help.
Shielded Cables: Connections between the workstation and peripherals must be made using shielded cables in order to
maintain compliance with FCC radio frequency emission limits. Networking connections can be made using unshielded
twisted pair (UTP) cables.
Modifications: Any modifications made to this device that are not approved by Sun Microsystems, Inc. may void the
authority granted to the user by the FCC to operate this equipment.
v
ICES-003 Class A Notice - Avis NMB-003, Classe A
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
ICES-003 Class B Notice - Avis NMB-003, Classe B
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
viSun Blade 1000 and Sun Blade 2000 UltraSPARCTM III Cu Module Installation Guide • June 2004
BSMI Class A Notice
The following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliance
label.
vii
viiiSun Blade 1000 and Sun Blade 2000 UltraSPARCTM III Cu Module Installation Guide • June 2004
Sun Blade 1000 and Sun Blade 2000
UltraSPARC III Cu CPU Module
Installation Guide
This document describes how to remove or install an UltraSPARC®III Cu CPU
module for the Sun Blade™ 1000 or Sun Blade 2000 workstation. The following
topics are discussed:
■ “Installation Kit Contents” on page 1
■ “Rules for Installing Cu CPU Modules” on page 2
■ “Identifying Cu CPU Modules” on page 3
■ “OpenBoot PROM and Software Requirements for UltraSPARC III Cu CPU
Modules” on page 5
■ “Installing the UltraSPARC III Cu CPU Module” on page 5
■ “Where to Find More Information” on page 26
Note – To install an UltraSPARC III 600, 750, or 900 MHz non Cu CPU module in a
Sun Blade 1000 workstation, see the Sun Blade 1000 UltraSPARC III Module
Installation Instructions, 816-0416-11.
Installation Kit Contents
Your UltraSPARC III Cu CPU module installation kit contains:
■ UltraSPARC III Cu CPU module
■ CPU torque tool
■ Disposable antistatic wrist strap
1
■ Antistatic mat
■ The UltraSPARC Cu CPU Module Installation Guide Roadmap, 816-2721, which
describes other documents you may need.
Rules for Installing Cu CPU Modules
You should verify which CPU modules are installed in your workstation before you
purchase or install new CPU modules.
Note – UltraSPARC III Cu CPU modules are marked “USIII Cu,” “USIII Cu-A,”
“USIII Cu-B,” or “USIII Cu-C” (FIGURE 1).
Processor type
Cu = copper process
- C
Processor version
and speed: C = 1.2 GHz
FIGURE 1Label on a 1.200 GHz UltraSPARC III Cu CPU Module
2Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu Module Installation Guide • June 2004
Sun Blade 1000 Workstation Configuration Rules
■ You can install UltraSPARC III Cu modules into a Sun Blade 1000 workstation.
However, both modules must be identical UltraSPARC III Cu modules. If the
module types are mixed (not identical), the workstation will not boot.
■ Always install the first CPU module into CPU slot 0 (connectors J0501 and J0601).
■ If you install a second CPU module, install it into CPU slot 1 (connectors J0701
and J0801).
Sun Blade 2000 Workstation Configuration Rules
■ The Sun Blade 2000 workstation only operates with UltraSPARC III Cu CPU
modules.
■ If two Cu CPUs are installed, they must be identical speeds. For example, two
1.200 GHz Cu-C modules, or two 900 MHz Cu modules.
Identifying Cu CPU Modules
Identifying a CPU Module
There are three ways to identify a CPU module:
■ Type the correct prtdiag command in a terminal window.
■ Inspect the CPU module for an UltraSPARC III Cu label
■ Check the part number label. (This method requires you to remove the module
from the workstation and is not recommended unless absolutely necessary.)
Software Method
In a terminal window, type one of these commands:
/usr/platform/SUNW,Sun-Blade-1000/sbin/prtdiag
The system displays CPU information similar to
Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu CPU Module Installation Guide3
CODE EXAMPLE 1.
CODE EXAMPLE 1Identifying a Workstation CPU Using prtdiag
% /usr/platform/SUNW,Sun-Blade-1000/sbin/prtdiag
==================================== CPUs ====================================
E$ CPU CPU Temperature
CPU Freq Size Implementation Mask Die Amb. Location
Note – The 1.050 GHz CPU appears as 1056 MHz. UltraSPARC-III+ indicates a Cu
module.
Module Label Method
All Cu CPU modules have an UltraSPARC III Cu label on the front of the CPU
module. See
FIGURE 1 and TABLE 1.
A part number label is also affixed to the printed circuit board of every CPU module.
Note – Avoid removing modules just to check the part number. First use the
prtdiag command or verify Cu modules by reading the label on the UltraSPARC III
Cu module.
TABLE 1CPU Module Part Number, Speed, and Type
Part Number
PrefixCPU Module Speed and TypeCPU LabelSystem
501-6002xxxxxx900 MHz UltraSPARC III CuUSIII Cu
501-6299xxxxxx1.015 GHz UltraSPARC III CuUSIII Cu-A
501-6395xxxxxx1.015 GHz UltraSPARC III CuUSIII Cu-A
501-6254xxxxxx1.050 GHz UltraSPARC III CuUSIII Cu-B
501-6396xxxxxx1.050 GHz UltraSPARC III CuUSIII Cu-B
501-6485xxxxxx1.200 GHz UltraSPARC III CuUSIII Cu-CSun Blade 2000
Sun Blade 1000
Sun Blade 2000
4Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu Module Installation Guide • June 2004
OpenBoot PROM and Software
Requirements for UltraSPARC III Cu
CPU Modules
You may need to upgrade your workstation’s OpenBoot™ PROM firmware, the
Solaris operating environment (OE) and related patches.
software versions necessary for installing Cu CPU modules.
TABLE 2Minimum OpenBoot PROM and Solaris Operating Environment
Sun Blade 1000Sun Blade 2000
TABLE 2 lists the minimum
Solaris Operating
Environment
OpenBoot PROM (OBP)
Solaris Patches
Note – Always check the Sun web site for the latest compatible operating
environment, firmware, and software updates for your workstation.
Installing the UltraSPARC III Cu CPU
Module
Before installing an UltraSPARC III Cu CPU module, verify the hardware and
software compatibility as described in the next section.
Solaris 8 10/01Solaris 8 02/02Solaris 8
HW 12/02
4.4.44.5.104.5.214.5.21
Obtain the latest patches for your Solaris operating environment at:
http://www.sunsolve.sun.com
Solaris 9 12/02
Verifying Software and Hardware Compatibility
1. Verify that the CPUs you intend to install are compatible.
See “Rules for Installing Cu CPU Modules” on page 2
Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu CPU Module Installation Guide5
2. Verify that the correct version of OpenBoot PROM firmware is installed on your
workstation (
Type the following command in a terminal window:
/usr/platform/sun4u/sbin/prtdiag -v
3. Verify that the correct version of the Solaris operating environment is installed on
your workstation (
Type the following command in a terminal window:
more /etc/release
4. Download the latest patches for your version of the Solaris operating
environment.
TABLE 2).
TABLE 2).
Note – You must install the correct Solaris operating environment and OpenBoot
PROM versions before installing the CPU, or the system will not boot.
Preparing for Installation
This section describes how to:
■ Power off the workstation
■ Remove the access panel
■ Attach an antistatic wrist strap
Note – If you are returning a used CPU module to Sun Microsystems, return the
used CPU module in the shipping box and packing materials that came with your
new or replacement CPU module.
Powering Off the Workstation
Caution – Before you turn off the power, save, back up, and close any open files.
Notify any affected users that you are powering off your workstation.
To power off the Workstation When the Solaris OE is Running
1. Save any open files or work in progress.
6Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu Module Installation Guide • June 2004
2. Press and release the keyboard sleep key or the front panel power switch
(
FIGURE 2).
3. From the menu displayed on the system monitor, select Shutdown.
To Power Off the Workstation When the System is at the ok
Prompt (OpenBoot PROM Interface)
1. Press and hold the front panel power switch for four seconds (FIGURE 2) to power
off the workstation.
This action forces an immediate power off of the workstation. Any unsaved data is
lost.
Verifying Power Off
Caution – Pressing the power switch does not remove all power from the
workstation. A trickle current remains in the power supply. To remove all power
from the workstation, disconnect the power cord.
FIGURE 2Workstation Power Switch
Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu CPU Module Installation Guide7
Power switch
1. Verify the following:
■ The backlit Sun Glogo on the front panel is off.
■ The workstation fans are not spinning.
2. Turn off power to the monitor and other external peripherals.
3. Disconnect the cables for any peripheral equipment.
4. Remove the lock block, if one is installed (
FIGURE 3).
If necessary, use a Phillips screwdriver to remove the screw and lock block.
FIGURE 3Removing the Lock Block
8Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu Module Installation Guide • June 2004
Lock block
Screw
Phillips
screwdriver
Removing the Access Panel
Note – If the power cord is connected, removal of the access panel activates the
workstation power interlock circuit. This safety mechanism prevents all DC voltages
(except +5 VDC standby power) from reaching any internal components.
1. Press down on the two depressions at the top of the access panel (
2. Tilt the top of the access panel about an inch (1.5 cm) away from the chassis.
3. Lift the access panel up.
4. Lift the access panel off.
FIGURE 4).
Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu CPU Module Installation Guide9
Depression(2)
Access panel
1
2
3
FIGURE 4Removing the Access Panel
4
10Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu Module Installation Guide • June 2004
Attaching the Disposable Antistatic Wrist Strap
Caution – Wear an antistatic wrist strap and use an antistatic mat when handling
Sun Blade 1000 and Sun Blade 2000 components. Before servicing or removing
workstation components, attach the strap to your wrist and then to a metal area on
the chassis. Then disconnect the power cord from the workstation and the wall
receptacle. This procedure equalizes all electrical potentials within the workstation.
1. Place the workstation on its side on a work surface, open side facing up (
FIGURE 5).
2. Unwrap the first two folds of the disposable antistatic wrist strap and wrap the
adhesive side firmly against your wrist.
3. Peel the liner from the copper foil at the opposite end of the wrist strap.
4. Attach the copper end of the wrist strap to the chassis (
FIGURE 5).
5. Disconnect the power cord.
Antistatic wrist strap
FIGURE 5Attaching the Antistatic Wrist Strap to the Chassis
Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu CPU Module Installation Guide11
Chassis
Power cord
CPU Module Positions in the Workstation
Caution – If the workstation has only one CPU, that CPU must be installed in CPU
processor slot 0 (connectors J0501 and J0601) See FIGURE 6.
The CPU modules are enclosed in a cooling shroud and secured to the shroud with
captive screws that must be torqued to specific values.
Note – Beginning in June 2004, CPU torque tools are not shipped in the Sun Blade
2000 workstation. The torque tools are shipped with the CPU modules.
Torque tool A
Torque tool B
CPU processor slot 0
Captive
FIGURE 6Location of CPU Processor Slot 0, Captive Screws, and Torque Tools
screw(2)
CPU processor slot 1
12Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu Module Installation Guide • June 2004
Removing a CPU Module
1. If necessary, place the workstation on its side on a work surface, open side facing
up (
FIGURE 6).
2. Remove torque tool A or torque tool B from the workstation or find the torque
tool in the new CPU module box.
3. If necessary, remove the filler panel (
FIGURE 7).
Squeeze the two tabs on the filler panel to release it from the cover for the CPU
shroud.
Tab (2)
Filler panel
Cover for the CPU
shroud
FIGURE 7Removing the Filler Panel
4. Complete one of the following steps:
Your selection depends on whether you are replacing an existing UltraSPARC III Cu
CPU module or installing an additional UltraSPARC III Cu CPU module into an
unused CPU processor slot.
■ If you are replacing an existing module and have torque tool A, perform Step 5.
Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu CPU Module Installation Guide13
CPU shroud
■ If you are replacing an existing module and have torque tool B, perform Step 6.
■ If you are installing an additional CPU module, perform Step 7.
Torque tool A
Right captive screw
Left captive
screw
FIGURE 8Using Torque Tool A to Remove the CPU Module
5. To remove an existing CPU module using torque tool A:
a. Alternately rotate the left and right captive screws one turn counterclockwise
until the screws are free of the threaded inserts (
Caution – Do not touch the board for the CPU module or its components. Touch
only the captive screws and plastic top cover of the module to avoid damaging
module components by electrostatic discharge (FIGURE 11).
14Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu Module Installation Guide • June 2004
CPU module
Shroud
FIGURE 8).
b. Use both hands to lift the CPU module out of the shroud.
c. Place the CPU module on an antistatic mat with the heat sink on the top facing
up.
d. Proceed to “Installing a New CPU Module” on page 17.
6. To remove an existing CPU module using torque tool B:
a. Remove the cover for the CPU shroud (
Squeeze the two tabs to release the cover for the CPU shroud from the
motherboard.
Cover for the CPU shroud
FIGURE 9).
Tab(2)
FIGURE 9Removing the Cover for the CPU Shroud
Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu CPU Module Installation Guide15
b. Alternately rotate the left and right captive screws one turn counterclockwise
until the screws are free of the threaded inserts (
FIGURE 10).
Torque tool B
Right captive screw
Left captive
screw
FIGURE 10Using Torque Tool B to Remove the CPU Module
Caution – As you remove the module from the shroud, handle it only by its
captive screws. Do not touch the connectors on the bottom edge of the module or the
electrical components on the module. The connectors and the components for the
module are easily bent or damaged by improper handling and by electrostatic
discharge (FIGURE 11).
c. Use both hands to lift the CPU module out of the shroud.
d. Place the CPU module on an antistatic mat with the heat sink on the top facing
up.
16Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu Module Installation Guide • June 2004
7. Proceed to “Installing a New CPU Module” on page 17.
Installing a New CPU Module
Caution – Perform the procedures described in TABLE 3 when unpacking a new
CPU module from its packing carton.
TABLE 3CPU Module Handling Procedures
StepDescription
1Use proper ESD grounding techniques when handling components.
Wear an antistatic wrist strap and use an antistatic mat. Store ESDsensitive components in antistatic bags before placing them on any
surface.
2When you remove the CPU module from its packing carton, use
both hands to support the module along its sides. Do not grip the
module by the heat sink.
3As you remove the module from its antistatic bag, handle it only by
its captive screws. Do not touch the connectors on the bottom edge
of the module. The connectors for the module are easily bent or
damaged by improper handling.
4Do not remove the plastic cover from the CPU module connectors
until you are ready to install the module into the workstation.
5Before you install the module, carefully inspect the connector pins
to ensure that they are not damaged. Never attempt to install a
module that has bent or damaged connectors.
Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu CPU Module Installation Guide17
1. Remove the plastic cover from the CPU module connector (FIGURE 11).
Plastic top cover
Captive screw(2)
CPU module
connector(2)
Plastic cover
CPU module
FIGURE 11Removing the Plastic Cover From the CPU Module Connectors
2. Lower the CPU module into the CPU shroud until the captive screws are aligned
with the two threaded inserts (
FIGURE 12).
18Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu Module Installation Guide • June 2004
CPU module
1
2
CPU shroud
Captive
screw (2)
Threaded
inserts (2)
FIGURE 12Lowering the CPU Module Into the Threaded Inserts
3. Tighten both captive screws by hand until the screws contact the threaded inserts
of the CPU shroud.
Once the CPU module is seated, surface contact between the captive screws and the
threaded inserts of the shroud typically occurs in less than one turn of both left and
right captive screws.
Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu CPU Module Installation Guide19
4. Do one of the following:
a. If you have torque tool A, perform steps 10-16 (
b. If you have torque tool B, perform steps 5-9 and 14-16 (
5. Use torque tool B to rotate the left captive screw one turn clockwise (
FIGURE 6).
FIGURE 6).
FIGURE 13).
Caution – Do not use a torque tool from another Sun product. The Sun Blade 1000
and Sun Blade 2000 torque tools are designed specifically for your workstation.
6. Use torque tool B to rotate the right captive screw one turn clockwise (
FIGURE 13).
Torque tool B
Right captive screw
Left captive screw
FIGURE 13Alternately Rotating Left and Right Captive Screws One Turn Clockwise
Caution – If you under-torque the CPU module captive screws, the contact between
the CPU module and the motherboard connector might be insufficient and the
workstation might not boot. Over-torquing the CPU module captive screws might
cause severe damage to the module and a potential workstation failure.
20Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu Module Installation Guide • June 2004
7. Repeat Step 5 and Step 6 until the gap for torque tool B is 0.0 inches (0.0 mm) See
FIGURE 14.
Use the torque tool to tighten the left and right captive screws to the correct torque.
Always rotate the left captive screw one turn clockwise and then rotate the right
captive screw one turn clockwise. This assures that a uniform and even torque is
applied to the CPU module.
Torque tool B
0.0 inches
FIGURE 14Adjusting Torque Tool B Until the Gap is 0.0 Inches (0.0 mm).
0.0 mm
8. Return torque tool B to its green plastic holder, then return the holder to its
storage location in the hard drive bracket.
9. If necessary install the cover for the CPU shroud (
FIGURE 15).
Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu CPU Module Installation Guide21
Cover for the
CPU shroud
FIGURE 15Installing the Cover for the Shroud
10. Use torque tool A to rotate the left captive screw one turn clockwise (FIGURE 16).
If the torque tool clicks, stop. Do not attempt to torque the captive screw anymore.
11. Use torque tool A to rotate the right captive screw one turn clockwise (
FIGURE 16).
If the torque tool clicks, stop. Do not attempt to torque the captive screw anymore.
22Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu Module Installation Guide • June 2004
Torque tool A
Right captive screw
Left captive screw
FIGURE 16Alternately Rotating Left and Right Captive Screws One Turn Clockwise
12. Repeat steps 10 and 11 until torque tool A clicks (FIGURE 17).
Seating occurs when both captive screws are evenly torqued to 5 inch-lbs.
(58 grams-meter). Torque tool A clicks when this adjustment specification is
achieved.
Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu CPU Module Installation Guide23
Torque tool A
Click
Captive screw(2)
FIGURE 17Torque Tool A Clicks When the Captive Screws Are Correctly Torqued
13. Return torque tool A to its storage location in the workstation.
14. If necessary, reinstall the filler panel for the shroud.
Caution – To ensure proper workstation cooling, any unused CPU slot must contain
a filler panel for the shroud (FIGURE 7).
15. Detach the antistatic wrist strap, replace the access panel, plug in the power cord,
and power on the workstation.
16. Proceed to “Finishing the Installation” on page 25.
24Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu Module Installation Guide • June 2004
Finishing the Installation
1. Remove the antistatic wrist strap from the chassis.
2. Replace the access panel.
3. Install a lock block on the back panel of the workstation.
4. Reconnect any cables from external devices to the workstation.
5. Reconnect the workstation power cord.
6. Power on the workstation:
a. Turn on power to the monitor and to all external devices.
b. Press the power switch on the front panel and release it.
c. After several seconds, verify that the power-indicator LED on the power switch
is energized and listen to verify that the workstation fans are operating
(spinning).
7. The workstation should automatically recognize installation of the new CPU
module(s).
Note – Perform a reconfiguration boot (boot -r). If the workstation correctly
boots, the CPU module has been correctly installed.
If problems are encountered, verify proper POST operation. See Section 3.4
“Maximum and Minimum Levels of POST” in the Sun Blade 1000 and Sun Blade 2000Service Manual, 816-3217.
8. If you are returning a used CPU module to Sun Microsystems, return the used
CPU module in the shipping box and packing materials that came with your new
or replacement CPU module.
Sun Blade 1000 and Sun Blade 2000 UltraSPARC III Cu CPU Module Installation Guide25
Where to Find More Information
The Sun Blade 1000 and Sun Blade 2000 Service Manual is available from the following
sources:
■ The manual is shipped with new workstations in HTML and PDF formats on the
Sun Blade 1000 and Sun Blade 2000 Hardware Documentation CD (705-0073). The
HTML version of the manual on this CD also includes this CPU replacement
procedure as an animated ShowMe How™ multimedia procedure.
■ A PDF version of this manual is available at:
http://www.sun.com/documentation/