Sun Microsystems J4400 Replacement Manual

Sun Storage J4400 Array
Chassis Replacement Guide
Sun Microsystems, Inc. www.sun.com
Part No. 820-4601-10 April 2008, Revision A
Submit comments about this document at: http://www.sun.com/hwdocs/feedback
Copyright 2008Sun Microsystems,Inc., 4150Network Circle, Santa Clara,California 95054,U.S.A. Allrights reserved. Sun Microsystems,Inc. hasintellectual property rights relatingto technologythat isdescribed inthis document.In particular, andwithout
limitation, theseintellectual propertyrights mayinclude oneor more of theU.S. patentslisted athttp://www.sun.com/patents and oneor more additionalpatents orpending patentapplications inthe U.S.and inother countries.
This documentand theproduct towhich itpertains are distributed underlicenses restrictingtheir use,copying, distribution,and decompilation. Nopart ofthe productor ofthis documentmay bereproducedin anyform byany meanswithout priorwritten authorizationof Sun andits licensors,if any.
Third-party software, including fonttechnology, is copyrightedand licensedfrom Sun suppliers. Parts ofthe productmay bederived from Berkeley BSDsystems, licensedfrom theUniversity ofCalifornia. UNIXis aregisteredtrademark in
the U.S.and inother countries,exclusively licensedthrough X/OpenCompany, Ltd. Sun, SunMicrosystems, theSun logo,AnswerBook2, docs.sun.com,and Solarisare trademarks or registered trademarksof SunMicrosystems,
Inc. inthe U.S.and inother countries. All SPARC trademarksare usedunder licenseand are trademarks orregistered trademarks of SPARCInternational, Inc.in theU.S. andin other
countries. Productsbearing SPARC trademarksare based upon an architecturedeveloped bySun Microsystems,Inc. The OPENLOOK andSun™ GraphicalUser Interfacewas developedby SunMicrosystems, Inc.for itsusers andlicensees. Sunacknowledges
the pioneeringefforts ofXerox in researchingand developingthe conceptof visualor graphicaluser interfacesfor thecomputer industry. Sun holds anon-exclusive licensefrom Xerox to theXerox GraphicalUser Interface,which licensealso coversSun’s licenseeswho implementOPEN LOOK GUIsand otherwisecomply withSun’s writtenlicense agreements.
U.S. GovernmentRights—Commercial use.Government usersare subject to the Sun Microsystems, Inc.standard licenseagreement and applicable provisionsof theFAR and itssupplements.
DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANYIMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FORA PARTICULAR PURPOSEOR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
Copyright 2008Sun Microsystems,Inc., 4150Network Circle, Santa Clara,Californie 95054,Etats-Unis. Tous droitsréservés. Sun Microsystems,Inc. ales droits de propriétéintellectuels relatants à latechnologie quiest décritdans cedocument. Enparticulier,et sansla
limitation, cesdroits depropriété intellectuels peuvent inclure unou plusdes brevetsaméricains énumérésà http://www.sun.com/patents et un oules brevetsplus supplémentaires ou lesapplications debrevet enattente dansles Etats-Uniset dansles autres pays.
Ce produitou documentest protégé par uncopyright etdistribué avecdes licencesqui enrestreignentl’utilisation, lacopie, ladistribution, etla décompilation. Aucunepartie dece produitou documentne peutêtre reproduite sousaucune forme,par quelquemoyen quece soit,sans l’autorisation préalableet écritede Sunet deses bailleursde licence,s’il yen a.
Le logicieldétenu pardes tiers,et quicomprend latechnologie relative aux policesde caractères,est protégé par uncopyright etlicencié pardes fournisseurs deSun.
Des partiesde ceproduit pourront être dérivéesdes systèmesBerkeley BSDlicenciés parl’Université deCalifornie. UNIXest unemarque déposée auxEtats-Unis etdans d’autrespays etlicenciée exclusivementpar X/OpenCompany, Ltd.
Sun, SunMicrosystems, lelogo Sun,AnswerBook2, docs.sun.com,et Solarissont desmarques de fabriqueou des marques déposéesde Sun Microsystems, Inc.aux Etats-Uniset dansd’autres pays.
Toutes les marquesSPARC sont utiliséessous licenceet sontdes marquesde fabrique ou des marquesdéposées deSPARCInternational, Inc. aux Etats-Uniset dansd’autres pays.Les produits portant lesmarques SPARC sontbasés surune architecture développée parSun Microsystems, Inc.
L’interfaced’utilisation graphiqueOPEN LOOKet Sun™a étédéveloppée parSun Microsystems, Inc. pourses utilisateurset licenciés.Sun reconnaît lesefforts de pionniers de Xeroxpour larecherche et le développement du concept des interfaces d’utilisation visuelle ou graphique pour l’industriede l’informatique.Sun détientune licensenon exclusivede Xeroxsur l’interfaced’utilisation graphiqueXerox,cette licence couvrant égalementles licenciéesde Sunqui mettenten placel’interface d’utilisation graphiqueOPEN LOOKet quien outrese conforment aux licencesécrites deSun.
LA DOCUMENTATION EST FOURNIE "EN L’ÉTAT" ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONTFORMELLEMENT EXCLUES,DANS LAMESURE AUTORISEEPAR LA LOIAPPLICABLE, YCOMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE, A L’APTITUDE A UNE UTILISATION PARTICULIERE OU A L’ABSENCE DE CONTREFAÇON.
Please

Contents

Replacing a J4400 Array Chassis 1
Prerequisites 1
Verifying a Chassis Failure 1
ESD Precautions 2
Removing a Chassis 2
Installing the New Chassis 9
Installing CRUs Into a New Chassis 11
Completing the Chassis Installation 14
Related Documentation 15
iii
iv Sun Storage J4400 Array Chassis Replacement Guide • April 2008

Replacing a J4400 Array Chassis

This document describes replacement procedures for the Sun Storage J4400 Array chassis.
Caution – Only trained service personnel should remove the covers on this
equipment.
This product is intended for restricted access whereby access is controlled through the use of a means of security (for example, key, lock, tool, badge access), and personnel authorized for access have been instructed on the reasons for the restrictions and any precautions that need to be taken.

Prerequisites

Before you start to replace a failed chassis, you must:
Back up all data stored on the array.
Stop all system I/O to the array.
Verify that the failed chassis is ready to be removed.
Prepare the work site and observe all “ESD Precautions” on page 2.
Remove all power from the chassis and chassis components.

Verifying a Chassis Failure

To determine that a chassis has failed, check the following:
The array System Power/Status LED (front) is amber.
1
The audible alarm is sounding.
All of the component fault LEDs are green.
Disk drive ID/Status LEDs (front) are green
SIM Power LED (back) is green
Power supply module LEDs (back) are green
Note – A steady amber LED on any component indicates a problem with that
component.

ESD Precautions

Observe the following electrostatic discharge (ESD) precautions:
Remove all plastic, vinyl, and foam material from the work area.
Wear an antistatic wrist strap at all times when handling any CRU.
Before handling any CRU, discharge any static electricity by touching a grounded
surface.
After removing a CRU from the cabinet, immediately place it on an antistatic mat.
Handle any card that is part of a CRU by its edges only and avoid touching the
components or circuitry.
Do not slide a CRU over any surface.
Limit body movement (which builds up static electricity) during the removal and
replacement of a CRU.

Removing a Chassis

Caution – You must remove power from the chassis that needs to be replaced
before starting this procedure. All interconnected trays will be disrupted during this procedure. Powering off one J4400 Array tray causes loss of access to other interconnected trays.
1. From the back of the cabinet, locate the chassis (also referred to as a tray) that is
being replaced (see “Verifying a Chassis Failure” on page 1).
2. Disconnect the power cord from each power supply (see
2 Sun Storage J4400 Array Chassis Replacement Guide • April 2008
FIGURE 1):
a. Remove the power cord tie strap from each power cord.
Power Cord
Connection from Host or SIM Link IN to Management Host
b. Disconnect each power cord from its power supply connector (see
FIGURE 1 Removing the Power Cable and Mini-SAS Cables
Connection Between Tray 0 and Tray 1
FIGURE 1).
Caution – For products with multiple power cords, all power cords must be
disconnected to completely remove power from the system.
3. Label each mini-SAS cable connection (see
FIGURE 1) for reconnection to the
same connectors on the replacement chassis. For example, “Tray 1, SIM Link Out to Tray 0, Host or SIM Link IN.”
4. Disconnect the labeled mini-SAS cables from each SIM board.
a. Grasp the metal body of the connector with one hand, and use your other
hand to firmly grasp and pull the tab.
b. Pull the tab gently toward the connector body, and, then with your other
hand, extract the connector from the bulkhead.
Replacing a J4400 Array Chassis 3
Caution – Do not twist the tab or pull it in any direction other than parallel with
the connector body. If the tab breaks, use a small sharp object (such as a fine-tipped screwdriver) to lift the metal spring at the top of the connector shell to unlatch it (see
FIGURE 1).
Caution – Electrical Shock Hazard. The power supplies in this equipment can
produce high energy hazards. Only instructed personnel with authorized access to this equipment can remove and replace modules in the system.
a. Loosen the two captive thumb screws on the power supply ejection levers
and swing the ejection levers fully outward to partially eject the power supply from the tray (see
FIGURE 2).
b. Pull the power supply out of the tray.
c. Place the power supply aside.
FIGURE 2 Removing a Power Supply
4 Sun Storage J4400 Array Chassis Replacement Guide • April 2008
5. Remove each SIM board from the chassis (see FIGURE 3).
Caution – Possible lose of configuration data. Label the SIM boards (SIM 0 and
SIM 1) as you remove them from the faulty chassis, and reinstall them in the new chassis in the same slot order to prevent possible loss of driver configuration data.
a. Loosen the captive thumb screws on the ejection levers and pull the
ejections levers out fully to partially eject the SIM board from the tray.
b. Pull the SIM board from chassis (see
FIGURE 3).
c. Place the SIM board aside in a static-free environment.
FIGURE 3 Removing a SIM Board From the Chassis
Replacing a J4400 Array Chassis 5
6. From the front of the cabinet, remove each disk drive and disk filler assembly
(see
FIGURE 4).
Caution – Potential loss of data access - Data might be lost if an active disk drive
is removed. If you remove an active disk drive accidentally, wait at least 30 seconds before reinserting it.
Caution – Potential loss of configuration information or data - Label each disk
drive with the slot from which it was removed, and reinstall each drive in the identical slot location in the replacement chassis.
a. Press the release button in and to the right to release the disk extraction
lever.
b. Swing the extraction lever fully out and to the right to partially extract the
disk drive from the tray.
c. Grasp the middle of the disk drive and pull it toward you to remove it from
the tray (see
FIGURE 4 Removing a Disk Drive or Disk Filler Assembly
FIGURE 4).
6 Sun Storage J4400 Array Chassis Replacement Guide • April 2008
d. Record the slot location on the outer drive casing. Use the same slot location
when installing each disk drive in the new chassis.
e. Store each disk drive in a static-free environment.
7. After you have removed all of the components from the chassis, remove the
chassis from the cabinet (see
FIGURE 6).
Caution – The empty weight of a chassis is 14 kg (32 lbs). You might need two
people to remove the chassis from the cabinet.
a. Remove the two system locking clips from the lower corners of the rear
chassis (see ). You can use a Phillips head screwdriver for leverage to help you pull out each clip. Set the clips aside.
FIGURE 5 Removing the System Locking Clips
J4400 Tray
Mounting Rail
Locking Clip
Locking Clip Installed
b. From the front of the cabinet, loosen the four captive screws, two on either
side of the tray.
Replacing a J4400 Array Chassis 7
c. Grasp each side of the chassis and pull it toward you, and remove it from the
cabinet (see
FIGURE 6 Removing the Failed Chassis From the Cabinet
FIGURE 6).
d. Package the failed chassis and return it to Sun, if instructed to do so, or
properly dispose of it.
8 Sun Storage J4400 Array Chassis Replacement Guide • April 2008

Installing the New Chassis

Caution – Follow all “ESD Precautions” on page 2 and use care when handling all
components.
1. From the front of the cabinet, slide the new chassis into the cabinet until the
front flanges of the chassis touch the vertical face of the cabinet (see
FIGURE 7 Installing the New Chassis in the Cabinet
FIGURE 7).
2. Tighten the captive screws on each side of the tray front to secure the chassis to the cabinet.
Replacing a J4400 Array Chassis 9
3. At the back of the cabinet, slide a system locking clip onto each lower corner of
the chassis (see
FIGURE 8). You can use a Phillips head screwdriver for leverage
to help you push in the clip.
FIGURE 8 Installing the System Locking Clips
J4400 Tray
Mounting Rail
Locking Clip
Locking Clip Installed
10 Sun Storage J4400 Array Chassis Replacement Guide • April 2008

Installing CRUs Into a New Chassis

1. From the front of the cabinet, install each disk drive and disk filler assembly into (see
Caution – Possible loss of configuration information or data - Reinstall each drive
into the identical slot location from which it was removed in the failed chassis, as defined by the notation written on the drive outer case when each drive was removed.
a. Unlatch and swing the extraction lever to its fully open position.
b. Align the disk component with the open slot and slide the drive into the tray
c. Press the extraction lever closed until it snaps in place on the disk front
FIGURE 9 Installing the Disk Drives and Filler Assemblies in New Chassis
FIGURE 9). For each disk drive and disk filler assembly:
until the extraction lever engages with the tray connectors and the lever begins to swing closed.
panel to seat the drive into the tray.
Replacing a J4400 Array Chassis 11
2. From the back of the cabinet, install the two SIM boards in the SIM slots (see
FIGURE 10).
Caution – Possible incorrect configuration or driver information - Reinstall the
SIM boards into the identical slot locations from which they were removed in the failed chassis.
For each SIM board:
a. Swing both extraction levers to the fully open position.
b. Align the SIM board with the open slot and slide it into the tray until it
engages with the tray connectors and the extraction levers begin to swing closed.
c. Simultaneously push both extraction levers toward the middle of the board
to seat it in the tray.
d. Tighten the extraction lever captive screws to secure the board.
FIGURE 10 Installing a SIM Board
12 Sun Storage J4400 Array Chassis Replacement Guide • April 2008
3. Install the two power supplies into the chassis slots (see FIGURE 11). For each power supply:
a. Swing both extraction levers to the fully open position.
b. Align the power supply with the open slot and slide it into the tray until it
engages with the tray connectors and the extraction levers begin to swing closed.
c. Simultaneously push both extraction levers toward the middle of the power
supply to seat it in the tray.
d. Tighten the extraction lever captive screws to secure the power supplies.
FIGURE 11 Installing a Power Supply
Replacing a J4400 Array Chassis 13

Completing the Chassis Installation

Caution – Possible incorrect configuration or loss of data - Reconnect all mini-SAS
cables to their original locations on each SIM board in the new chassis.
Power Cord
1. From the back of the cabinet (see
FIGURE 12), reconnect the country-specific
power cables into each of the power supply connectors.
2. Replace the power cord tie strap on each power cord.
3. Turn on power to both power supplies.
FIGURE 12 Reconnecting the Mini-SAS and Power Cables
Connection from Host or SIM Link IN to Management Host
14 Sun Storage J4400 Array Chassis Replacement Guide • April 2008
Connection Between Tray 0 and Tray 1
4. Check the status of the tray.
After the power-on sequence is complete, confirm the following:
The green OK/Power LEDs on each drive in the tray are steady on.
If all tray and drive OK/Power LEDs are steady green and the amber Service Required LEDs are off, the power-on sequence is complete and no faults have been detected.
The amber LED is blinking for any module.
Reseat the module to make sure that it is properly installed. If the LED is now green, the module is functioning properly. If the module remains blinking amber, contact Sun Customer Service Personnel.
The alarm shuts off after connecting the second power cord.
If an alarm sounds after plugging in the first power cord, the alarm will shut off once the second power cord is connected.

Related Documentation

For additional information about the Sun Storage J4400 Array chassis, see the following product documentation:
Application Title Part Number
Regulatory and safety information
Multilanguage safety information
Site planning information Sun Storage J4200/J4400 Array Site
Installation at a glance Sun Storage J4200 Array Setup Poster 820-3221-nn
Installation at a glance Sun Storage J4400 Array Setup Poster 820-4691-nn
Complete details of the hardware components, rail and tray installation, and cabling.
Late-breaking information not included in the information set
Sun StorageTek Regulatory and Safety Compliance Manual
Important Safety Information for Sun Hardware Systems
Preparation Guide
Sun Storage J4200/J4400 Array Hardware Installation Guide
Sun Storage J4200/J4400 Array Release Notes
Replacing a J4400 Array Chassis 15
96272, Revision A
816-7190-nn
820-3219-nn
820-3218-nn
820-3222-nn
Application Title Part Number
Installation and use of the management software using a GUI
Installation and use of the management software using a CLI
General operation and troubleshooting
Disk drive replacement procedures
SIM board replacement procedures
SIM board replacement procedures
Power supply replacement procedures
Fan replacement procedures Sun Storage J4200 Array Fan Replacement
Power supply and fan replacement procedures
Chassis replacement procedures
Chassis replacement procedures
Rail kit installation procedures
Sun StorageTek Common Array Manager User Guide for the J4000 Array Family
Sun StorageTek Common Array Manager CLI Guide for the J4000 Array Family
Sun Storage J4200/J4400 Array Overview 820-3223-nn
Sun Storage J4200/J4400 Array Disk Drive Replacement Guide
Sun Storage J4200 Array SIM Board Replacement Guide
Sun Storage J4400 Array SIM Board Replacement Guide
Sun Storage J4200 Array Power Supply Replacement Guide
Guide
Sun Storage J4400 Array Power Supply/Fan Replacement Guide
Sun Storage J4200 Chassis Replacement Guide
Sun Storage J4400 Chassis Replacement Guide
Sun Storage J4200/J4400 Array Rail Kit Installation Guide
820-3765-nn
820-4419-nn
820-3225-nn
820-3226-nn
820-4600-nn
820-3227-nn
820-3229-nn
820-3228-nn
820-4413-nn
820-4601-nn
820-3764-nn
Service Contact Information
If you need help installing or using this product in the United States, call 1-800-USA-4SUN(872-4786), or go to:
http://www.sun.com/service/contacting/index.xml
16 Sun Storage J4400 Array Chassis Replacement Guide • April 2008