2 Installation and Operating Instructions (Original Instructions)
Light Drainage Pump Type ABS Robusta 200 and 300
Light Drainage Pump Type ABS Robusta
200 300
Symbols used in this booklet:
Non-compliance may result in personal
m
c
NOTE:
Symbols directly on the unit itself must be carefully
observed and must be maintained in a legible
condition, e.g. direction of rotation arrow and
nameplate.
injury.
Presence of dangerous voltage.
Important information for particular
attention.
Safety
(Extracted from VDMA-Standard sheet 24292)*
This unit can be used by children aged 8
years and above, and persons with reduced
physical, sensory, or mental capabilities,
or lack of experience and knowledge,
when they have been given supervision
or instruction concerning the safe use of
the device and understand the hazards
involved. Children must not play with the
appliance. Cleaning and user maintenance
should not be performed by children without
supervision.
To avoid injury when the pump is in
operation, do not handle the impeller
m
These operating instructions contain basic
information on erection, operating and maintenance
and should be followed carefully. For this reason
it is essential that these instructions are carefully
read before erection or commissioning by both the
installation crew as well as those responsible for
operation or maintenance. The operating instructions
should always be readily available at the location of
the unit.
In addition to following the safety regulations of a
general nature listed under these main headings, it
is also essential that the special safety instructions
given under other headings be observed.
The safety instruction listed in this operating manual,
the existing National Regulations for safety, as well
as any internal operating or safety regulations which
apply in the user’s own premises must be observed.
screen or place ngers near the suction
hole if the suction ring is removed.
The general and specic health and safety guidelines
are described in detail in the “Safety Instructions for
Sulzer Products Type ABS” booklet. If anything is not
clear or you have any questions as to safety make
certain to contact the manufacturer Sulzer.
Dangers which could arise due to nonobservance of safety instructions
The non-observance of the safety instructions can
lead to both danger to personnel and also to possible
harm to the environment or the unit itself. Nonobservance of the safety instructions can invalidate
the rights of the user to any compensation or redress.
In detail, non-observance can for example result in
the following dangers:
- Failure of important functions of the unit/installation
- Danger to personnel by electrical, mechanical or
chemical inuences
- Danger to the environment by leakage of
dangerous substances
NOTE: Carry out work in a safety conscious
manner.
Safety regulations for the owner/operator
All dangers due to electricity must be avoided (for
details consult the Regulations of your local Electricity
Supply Company).
Safety regulations for maintenance,
inspection and installation work
The user of the unit should ensure that all
maintenance, inspection or installation work is carried
out by authorised and qualied skilled personnel. The
user must also make certain that they have carefully
studied the operating instructions. In principle all
work on the unit should only be carried out while
it is stationary. Pumps or units, used for pumping
of uids which could be injurious to health must be
decontaminated. After completion of the work all
safety and protective devices must be retted and a
check should be made that they are fully functional.
Before starting up again, the points listed under the
section “Commissioning” should be complied with.
Unilateral modication and spare parts
manufacturing
Modications or changes to the unit/installation
should only be carried out after consultations with the
manufacturer. Original spare parts and accessories
authorised by the manufacturer are essential for
compliance with safety requirements. The use of
other parts can invalidate any claims for warranty or
compensation.
Sulzer reserves the right to alter specications due to technical developments.
Page 3
Installation and Operating Instructions (Original Instructions) 3
Light Drainage Pump Type ABS Robusta 200 and 300
Unproven usage
The operating safety of the unit is only guaranteed
provided that the unit is used in accordance with the
operating and safety instructions. The limit values
given in the technical data sheet should under no
circumstance be exceeded.
These installation and operation instructions do not
supersede or exclude the following of generally valid
regulation and standards.
*VDMA=Verband Deutscher Maschinen- und
Anlagebau e.V. (German Machinery Manufacturers
Association).
End of life units can be returned to
Sulzer or recycled in accordance with
local regulations.
Transport
During transport the unit should not be dropped or
thrown.
The unit should never be raised or
c
A handle is provided for transport. If necessary, it is
possible to suspend the pump by attaching a rope or
chain to the handle.
lowered by the power cable.
m
This product is only suitable for
removing clear and dirty water up to a
water temperature of 40 °C or up to a
maximum of 60 °C during short-term
operation.
If the system is fed water from products
such as washing machines, then the
maximum water temperature could be
exceeded if the device is not equipped
with discharge cooling or if this is not
switched on, e.g. in order to save energy.
This may cause damage to the pump
or the pumping system. In such case
Sulzer will not accept any guarantee or
warranty claim.
If necessary, contact the manufacturer
of the device or devices provided for
connection (e.g. washing machines) to
obtain information on how to switch on
discharge cooling.
Our systems are checked in accordance
with EN 12050 LGA and conform to the
current standards.
Also note that the maximum inlet
temperature to the public sewer system
is 35 °C and that you must ensure that
the water is cooled accordingly.
Application
The submersible wastewater pumps of the Robusta
series are reliable quality products designed for the
following applications:
- Pumping of clear water.
- Pumping of rain water.
- Pumping of waste-water with a maximum solids
content of 0.5%
The pump must not be used in an
c
explosive or ammable environment or
for pumping ammable liquids.
NOTE: As with all electrical devices, this
product may fail due to operating
errors, absence of mains voltage,
or even a technical defect. Such a
failure may result in the medium or
water escaping. If damage may occur
due to such failures, measures are
required to avoid damage arising.
In this respect, taking account of
the conditions in question, use of
an emergency generator, provision
of an additional and appropriately
connected second unit, and
particularly the use of an off-grid
alarm system, are to be considered.
These pumps should not be used for the pumping of:
-Faecal matter.
-Aggressive uids such as acids, lyes (caustic
soda) or salts.
-Flammable liquids such as petrol, oil or phenols.
The pumps conform to the EU machine directive. See
nameplate.
NOTE Leakage of lubricants could result
in pollution of the medium being
pumped.
Nameplate
We recommend that you record the data from the
standard nameplate on the pump in the corresponding
form below, and maintain it as a source of reference
for the ordering of spare parts, repeat orders and
general queries.
Always state the pump type, item no. and serial no. in
all communications.
1082-03
Typ
Nr SN
UN V Ph IN A HZ P1: kW
Qmax m
Insul. Cl.B m
Made in Ireland
Legend
TypPump type
Nr.Item number
SNSerial number
xx/xxxxProduction date (week/year)
U
nRated voltageV
PhNumber of phases
I
nRated currentA
HzFrequencyHz
P1Rated input powerkW
QmaxMax. owm
HmaxMax. headm
nSpeedr/min
Insul.Cl.Insulation class
IPProtection type
▽
3
/h Hmax m n 1/min
Sulzer Pump Solutions Ireland Ltd.
Wexford, Ireland
www.sulzer.com
Max submersible depthm
3
/h
Performance
Maximum total head: Robusta 200 = 6.3 m
Robusta 300 = 8.6 m
Commissioning
The manufacturer guarantees that a new pump
will not emit airborne noise in excess of 70 dB(A)
during normal operation, when either fully or partially
submerged.
Before commencing operations, the pump/pump
station should be examined and a function check
carried out. Particular attention should be paid to the
following:
- Check that the power cable and plug are
undamaged.
- Does the electrical connection comply with
regulations?
- Is the motor overload correctly set?
- Is the level control system operating correctly?
- Are the switch ON switch OFF levels correctly set?
The pump must not be run if it has been
m
m
c
c
c
NOTE Suitable earth leakage protection
partially dismantled.
In all installations, the power supply to
the Robusta pump must be via a residual
current device (e.g. RCD, ELCB, RCBO
etc.) with a rated residual operating
current not exceeding 30 mA. For
installations not having a xed residual
current device the pump must be
plugged into the power supply through a
portable version of the device.
In the case of Class I (EN 60335)
submersible pumps such as the Robusta
series, all accessible metal parts are
connected to the earth lead. Before
operation a qualied person should
check that the earth lead is correctly
connected.
Robusta pumps must not be operated
in places where a person could be
immersed or in contact with the
pumped medium, either intentionally or
accidentally, e.g. swimming pool, garden
pond, fountain, ooded area.
Pumps for use in swimming pools where
people are present must only use
Class III (EN 60335) pumps with a
voltage not greater than 12 V.
devices are available from electrical
suppliers. Please consult your
electrician.
Page 5
Installation and Operating Instructions (Original Instructions) 5
Light Drainage Pump Type ABS Robusta 200 and 300
Service and maintenance
Before any work is started, check that
c
c
Regular inspection and preventive maintenance will
ensure more reliable operation. The pump should be
inspected every six months, but more frequently if the
operating conditions are difcult.
However, should a fault occur, do not attempt to
improvise but call on your Sulzer Service Centre.
This applies particularly in the case where the unit
is continually switched off by the current overload in
the control panel, or by the thermal sensors of the
thermo-control-system.
For a complete overhaul of the pump, please get in
touch with an authorized Sulzer workshop or your
Sulzer dealer.
If the pump is taken out of service, in order to prevent
deposition of soil or other materials the pump should
be cleaned by pumping clear water.
If there are leaves or brous matter in the medium
being pumped we recommend that the inlet screen be
cleaned from time to time.
Rotate the inlet screen clockwise to remove it, and
anti-clockwise to lock it back into place.
the pump is isolated from the power
supply and cannot be energized.
To avoid danger, if the power cable is
damaged it must be replaced by the
manufacturer or its service agent or a
similarly qualied person.
Electrical connections
The pump must be connected to terminals or starting
equipment installed at a level at which the pump
cannot be ooded.
All electrical equipment must always be
c
c
Check that the mains voltage, frequency, starting
equipment, and method of starting agree with the
particulars stamped on the motor nameplate.
The unit should be protected by a correctly
dimensioned slow blow fuse (suitable for the rated
power of the pump). We recommend the use of an
overload relay. The electrical installation shall be
inspected by an authorized electrician.
earthed (grounded). This applies to the
pump and to any monitoring equipment.
The electrical installation must conform
to national and local regulations.
TS-version:
- Remove the oat housing from the pump by
pressing it in at its sides at its lower end and pulling
it free from the motor housing.
- Remove the oat from the oat housing.
- Clean all parts.
- Ret the oat and oat housing.
- When pressing on the oat housing it is necessary
that the change-over switch “HAND AUTOMATIC”
is in the lower position.
- Press the selector switch upwards and check the
pump at setting “HAND”.
KS-version:
- Clean oat
Page 6
6 Installation and Operating Instructions (Original Instructions)
Light Drainage Pump Type ABS Robusta 200 and 300
Robusta assembly
2
1
1083-02
3
6
4
5
7
1. Non-return valve3. HAND / AUTO selector switch5. Float housing7. Suction ring (see tting
2. Discharge line connection4. Level control oat6. Inlet screen
instructions page 7)
Page 7
Installation and Operating Instructions (Original Instructions) 7
Light Drainage Pump Type ABS Robusta 200 and 300
Suction ring
When tted into the impeller screen allows pumping down to 3 mm (manual operation only).
To avoid personal injury, or damage to the pump, disconnect it from the power supply before