Subzero PRO Refrigeration Series, ICBPRO4850, ICBPRO3650, ICBPRO4850G, ICBPRO3650G Design Manual

Page 1
NEW PRO REFRIGERATION
DESIGN GUIDE
ICB REVISED 5/ 2019
Page 2
TABLE OF CONTENTS
3 PRO REFRIGERATION
6 OPENING DIMENSIONS
8 ELECTRICAL
8 PLUMBING
9 STANDARD HANDLES
11 SUB-ZERO WARRANTY
Features and specications are subject to change at any time without notice.
Throughout this guide, dimensions may vary by ± 3 mm.
Page 3
PRO REFRIGERATION
PRO Refrigeration
Freshness nds unmistakable expression with Sub-Zero PRO Refrigeration. A monument to food preservation— equal parts sculpted metal design statement and culinary secret weapon. Its vast interior, like its bold exterior, is crafted of stainless steel. Available in 914 mm and 1219 mm widths, with a glass or solid door, and may be either built in or freestanding.
PRO MODELS
ICBPRO3650
ICBPRO3650G
ICBPRO4850
ICBPRO4850G
subzero.com | 3
Page 4
SPECIFICATIONS
Overall Dimensions
914 mm MODEL
914 mm
HEIGHT DIMENSIONS ± 13 mm
606 mm
1070
mm
775 mm
660 mm
2134
mm
657 mm
102 mm
767 mm
660 mm
Model ICBPRO3650 / ICBPRO3650G
4 | English
60 mm
949 mm
SPECIFICATIONS
INTERIOR CAPACITY L L
ICBPRO3650 521 122 ICBPRO3650G 521 122
SHIPPING WEIGHT KG
ICBPRO3650 286 ICBPRO3650G 295
Page 5
SPECIFICATIONS
Overall Dimensions
1219 mm MODEL
606 mm
660 mm
1219 mm
HEIGHT DIMENSIONS ± 13 mm
1070
mm
775 mm
533 mm
2134
mm
102 mm
606 mm
781 mm
657 mm
767 mm
368 mm
Model ICBPRO4850 / ICBPRO4850G
60 mm
SPECIFICATIONS
INTERIOR CAPACITY L L
ICBPRO4850 530 331 ICBPRO4850G 530 331
SHIPPING WEIGHT KG
ICBPRO4850 390 ICBPRO4850G 399
subzero.com | 5
Page 6
SPECIFICATIONS
NOTE: 89 mm finished retur
SIDE
Opening Dimensions
STANDARD | FLUSH INSTALLATION
D
OPENING
DEPTH
89 mm
FINISHED
RETURN
19 mm
TYPICAL
VIEW
H
OPENING
HEIGHT
TOP VIEW
W
OPENING WIDTH
FRONT VIEW
W
89 mm
FINISHED
RETURN
W
FRAMELESS
CABINETRY
FRAMED
CABINETRY
19 mm
TYPICAL
FILLER
STANDARD OPENING W
914 mm Model 902 mm 2127 mm 610 mm
1219 mm Model 1206 mm 2127 mm 610 mm
For standard installations, the face frame will extend 51 mm beyond cabinetry.
6 | English
ns will be visible and should be finished to match cabinetry.
H D
FLUSH OPENING
W H D
914 mm Model 914 mm 2137 mm 660 mm
1219 mm Model 1219 mm 2137 mm 660 mm
For ush installations, the face frame will be ush with sur­rounding cabinetry.
Page 7
SPECIFICATIONS
NOTE: 89 mm finished retur
SIDE
Opening Dimensions
DUAL STANDARD | FLUSH INSTALLATION
D
OPENING
DEPTH
89 mm
FINISHED
RETURN
19 mm
TYPICAL
VIEW
H
OPENING
HEIGHT
TOP VIEW
W
OPENING WIDTH
FRONT VIEW
W
89 mm
FINISHED
RETURN
W
FRAMELESS
CABINETRY
FRAMED
CABINETRY
19 mm
TYPICAL
FILLER
DUAL STANDARD OPENING W
Two 914 mm Models 1816 mm 2127 mm 610 mm
For standard installations, the face frame will extend 51 mm beyond cabinetry. A dual installation kit is required for this installation.
ns will be visible and should be finished to match cabinetry.
H D
DUAL FLUSH OPENING
W H D
Two 914 mm Models 1829 mm 2137 mm 660 mm
For ush installations, the face frame will be ush with sur­rounding cabinetry. A dual installation kit is required for this installation.
subzero.com | 7
Page 8
SPECIFICATIONS
Electrical Requirements
Installation must comply with all applicable electrical codes and be properly grounded (earthed).
International models from the factory designed without a transformer require a 220-240 V AC, 50/60 Hz electrical supply, fused at the correct rating for the unit. If required by local or national codes, the power cord can be easily replaced using the power inlet device.
Locate the electrical supply within the shaded area shown in the illustration below. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
ELECTRICAL REQUIREMENTS
Power Supply 220-240 V AC, 50/60 Hz
Circuit Breaker 10 amp
Receptacle grounding-type (earthed)
Plumbing Requirements
Installation must comply with all applicable plumbing codes.
Locate the water supply line within the shaded area shown in the illustration below. Connect the water supply line to the house supply with an easily accessible shut-off valve. Do not use self-piercing valves. The water supply line must not interfere with the installation of the anti-tip bracket.
A reverse osmosis system can be used provided there is constant water pressure of 2.4–8.3 bar supplied to the unit at all times. A copper line is not recommended for this application.
PLUMBING REQUIREMENTS
Water Supply 6.4 mm OD copper line,
braided stainless steel, or PEX tubing
Water Pressure 2.4–8.3 bar
Excess Water Line for Connection .9 m
RIGHT SIDE
OF OPENING
178
E
mm
152 mm
1918 mm
FROM FLOOR
RIGHT SIDE
OF OPENING
Electrical supply location
132
152
mm
mm
76 mm
AREA EXTENDS 13 mm
FORWARD ON FLOOR
Water supply location
8 | English
Page 9
SPECIFICATIONS
Standard Handles
Optional stainless steel pro handles are avail able through an authorized Sub-Zero dealer. Refer to the chart below for standard handle lengths for PRO models.
HANDLE LENGTH
Door 703 mm 703 mm
Refrigerator Drawer 665 mm 506 mm
Freezer Drawer 665 mm 294 mm
914 mm MODEL 1219 mm MODEL
subzero.com | 9
Page 10
Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf & Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries. All other trademarks are property of their respective owners in the United States and other countries.
10 | English
Page 11
Sub-Zero International Limited Warranty
FOR RESIDENTIAL USE
FULL TWO YEAR WARRANTY*
For two years from the date of original installation, this Sub-Zero product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defec­tive in materials or workmanship. All service provided by Sub-Zero under the above warranty must be performed by Sub-Zero factory certied service, unless otherwise specied by Sub-Zero, Inc. Service will be provided during normal business hours.
FULL FIVE YEAR SEALED SYSTEM WARRANTY
For ve years from the date of original installation, this Sub-Zero product warranty covers all parts and labor to repair or replace, under normal residential use, these parts that prove to be defective in materials or workmanship: compressor, condenser, evaporator, drier and all connecting tubing. All service provided by Sub-Zero under the above warranty must be performed by Sub-Zero factory certied service, unless otherwise specied by Sub-Zero, Inc. Service will be provided during normal business hours.
For more information regarding your Sub-Zero product warranty, contact your authorized Sub-Zero dealer. Warranties must comply to all country, state, city, local and or ordinance.
*Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited 60-day parts and labor warranty for cosmetic defects.
*Replacement water lters and air purication cartridges are not covered by the product warranty.
Page 12
SUBZERO.COM