Features and specications are subject to change at any
time without notice.
Throughout this guide, dimensions may vary by ± 3 mm.
Page 3
PRO REFRIGERATION
PRO Refrigeration
Freshness nds unmistakable expression with Sub-Zero
PRO Refrigeration. A monument to food preservation—
equal parts sculpted metal design statement and culinary
secret weapon. Its vast interior, like its bold exterior, is
crafted of stainless steel. Available in 914 mm and 1219 mm
widths, with a glass or solid door, and may be either built in
or freestanding.
PRO MODELS
ICBPRO3650
ICBPRO3650G
ICBPRO4850
ICBPRO4850G
subzero.com | 3
Page 4
SPECIFICATIONS
Overall Dimensions
914 mm MODEL
914 mm
HEIGHT DIMENSIONS ± 13 mm
606
mm
1070
mm
775
mm
660
mm
2134
mm
657 mm
102 mm
767 mm
660
mm
Model ICBPRO3650 / ICBPRO3650G
4 | English
60 mm
949
mm
SPECIFICATIONS
INTERIOR CAPACITYLL
ICBPRO3650521122
ICBPRO3650G521122
SHIPPING WEIGHTKG
ICBPRO3650286
ICBPRO3650G295
Page 5
SPECIFICATIONS
Overall Dimensions
1219 mm MODEL
606
mm
660
mm
1219 mm
HEIGHT DIMENSIONS ± 13 mm
1070
mm
775
mm
533
mm
2134
mm
102 mm
606
mm
781
mm
657 mm
767 mm
368
mm
Model ICBPRO4850 / ICBPRO4850G
60 mm
SPECIFICATIONS
INTERIOR CAPACITYLL
ICBPRO4850530331
ICBPRO4850G530331
SHIPPING WEIGHTKG
ICBPRO4850390
ICBPRO4850G399
subzero.com | 5
Page 6
SPECIFICATIONS
NOTE: 89 mm finished retur
SIDE
Opening Dimensions
STANDARD | FLUSH INSTALLATION
D
OPENING
DEPTH
89 mm
FINISHED
RETURN
19 mm
TYPICAL
VIEW
H
OPENING
HEIGHT
TOP VIEW
W
OPENING WIDTH
FRONT VIEW
W
89 mm
FINISHED
RETURN
W
FRAMELESS
CABINETRY
FRAMED
CABINETRY
19 mm
TYPICAL
FILLER
STANDARD OPENING W
914 mm Model902 mm2127 mm610 mm
1219 mm Model1206 mm2127 mm610 mm
For standard installations, the face frame will extend 51 mm
beyond cabinetry.
6 | English
ns will be visible and should be finished to match cabinetry.
HD
FLUSH OPENING
WHD
914 mm Model914 mm2137 mm660 mm
1219 mm Model1219 mm2137 mm660 mm
For ush installations, the face frame will be ush with surrounding cabinetry.
Page 7
SPECIFICATIONS
NOTE: 89 mm finished retur
SIDE
Opening Dimensions
DUAL STANDARD | FLUSH INSTALLATION
D
OPENING
DEPTH
89 mm
FINISHED
RETURN
19 mm
TYPICAL
VIEW
H
OPENING
HEIGHT
TOP VIEW
W
OPENING WIDTH
FRONT VIEW
W
89 mm
FINISHED
RETURN
W
FRAMELESS
CABINETRY
FRAMED
CABINETRY
19 mm
TYPICAL
FILLER
DUAL STANDARD OPENING W
Two 914 mm Models1816 mm2127 mm610 mm
For standard installations, the face frame will extend 51 mm
beyond cabinetry. A dual installation kit is required for this
installation.
ns will be visible and should be finished to match cabinetry.
HD
DUAL FLUSH OPENING
WHD
Two 914 mm Models1829 mm2137 mm660 mm
For ush installations, the face frame will be ush with surrounding cabinetry. A dual installation kit is required for this
installation.
subzero.com | 7
Page 8
SPECIFICATIONS
Electrical Requirements
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
International models from the factory designed without a
transformer require a 220-240 V AC, 50/60 Hz electrical
supply, fused at the correct rating for the unit. If required
by local or national codes, the power cord can be easily
replaced using the power inlet device.
Locate the electrical supply within the shaded area shown
in the illustration below. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Power Supply220-240 V AC, 50/60 Hz
Circuit Breaker10 amp
Receptaclegrounding-type (earthed)
Plumbing Requirements
Installation must comply with all applicable plumbing codes.
Locate the water supply line within the shaded area shown
in the illustration below. Connect the water supply line to the
house supply with an easily accessible shut-off valve. Do
not use self-piercing valves. The water supply line must not
interfere with the installation of the anti-tip bracket.
A reverse osmosis system can be used provided there
is constant water pressure of 2.4–8.3 bar supplied to the
unit at all times. A copper line is not recommended for this
application.
PLUMBING REQUIREMENTS
Water Supply 6.4 mm OD copper line,
braided stainless steel, or PEX tubing
Water Pressure2.4–8.3 bar
Excess Water Line for Connection.9 m
RIGHT SIDE
OF OPENING
178
E
mm
152
mm
1918 mm
FROM FLOOR
RIGHT SIDE
OF OPENING
Electrical supply location
132
152
mm
mm
76 mm
AREA EXTENDS 13 mm
FORWARD ON FLOOR
Water supply location
8 | English
Page 9
SPECIFICATIONS
Standard Handles
Optional stainless steel pro handles are avail able through
an authorized Sub-Zero dealer. Refer to the chart below for
standard handle lengths for PRO models.
HANDLE LENGTH
Door703 mm703 mm
Refrigerator Drawer665 mm506 mm
Freezer Drawer665 mm294 mm
914 mm MODEL 1219 mm MODEL
subzero.com | 9
Page 10
Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf &
Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries.
All other trademarks are property of their respective owners in the United States and other countries.
10 | English
Page 11
Sub-Zero International Limited Warranty
FOR RESIDENTIAL USE
FULL TWO YEAR WARRANTY*
For two years from the date of original installation, this Sub-Zero product warranty covers all parts and
labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Sub-Zero under the above warranty must be
performed by Sub-Zero factory certied service, unless otherwise specied by Sub-Zero, Inc. Service will
be provided during normal business hours.
FULL FIVE YEAR SEALED SYSTEM WARRANTY
For ve years from the date of original installation, this Sub-Zero product warranty covers all parts and
labor to repair or replace, under normal residential use, these parts that prove to be defective in materials
or workmanship: compressor, condenser, evaporator, drier and all connecting tubing. All service provided
by Sub-Zero under the above warranty must be performed by Sub-Zero factory certied service, unless
otherwise specied by Sub-Zero, Inc. Service will be provided during normal business hours.
For more information regarding your Sub-Zero product warranty, contact your authorized Sub-Zero dealer.
Warranties must comply to all country, state, city, local and or ordinance.
*Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited
60-day parts and labor warranty for cosmetic defects.
*Replacement water lters and air purication cartridges are not covered by the product warranty.
Page 12
SUBZERO.COM
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.