Features and specications are subject to change at any
time without notice. Visit subzero.com/specs for the most
up-to-date information.
Important Note
To ensure this product is installed and operated as safely
and efciently as possible, take note of the following types
of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION indicates a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specied.
IMPORTANT NOTE: Save these instructions for the local
electrical inspector.
2 | Sub-Zero Customer Care 800.222.7820
PRO REFRIGERATION
Product Information
Important product information, including the model and
serial number, are listed on the product rating plate. The
rating plate is located inside the cabinet, attached to the left
interior wall of the bottom drawer. Refer to the illustration
below.
If service is necessary, contact Sub-Zero Factory Certied
Service with the model and serial number. For the name
of the nearest Sub-Zero Factory Certied Service or for
questions regarding the installation, visit the contact
and support section of our website, subzero.com, or call
Sub-Zero Customer Care at 800-222-7820.
RATING
PLATE
Tools and Materials
• Screwdrivers—standard, Phillips, Torx, and hex.
• Power drill.
• Drill bits (masonry bits required for concrete installation).
• Standard Allen wrench set.
• Standard socket and wrench set.
• 2' and 4' levels.
• Tubing cutter.
1
• 3' of
• Saddle valve.
• Material to protect home, ooring, and cabinetry during
/4" OD copper, braided stainless steel, or PEX
tubing.
installation.
Rating plate location
subzero.com | 3
SITE PREPARATION
NOTE:
SIDE
Opening Dimensions
STANDARD | FLUSH INSTALLATION
H
OPENING
HEIGHT
D
OPENING
DEPTH
TOP VIEW
W
OPENING WIDTH
31/2" (89)
FINISHED
RETURN
W
31/2" (89)
FINISHED
RETURN
W
FRAMELESS
CABINETRY
FRAMED
CABINETRY
3
/4" (19)
TYPICAL
3
/4" (19)
TYPICAL
FILLER
VIEW
31/2" (89) finished returns will be visible and should be finished to match cabinetry.
For ush installations, the face frame will be ush with surrounding cabinetry.
NOTE:
SIDE
SITE PREPARATION
Opening Dimensions
DUAL STANDARD | FLUSH INSTALLATION
H
OPENING
HEIGHT
D
OPENING
DEPTH
TOP VIEW
W
OPENING WIDTH
31/2" (89)
FINISHED
RETURN
W
31/2" (89)
FINISHED
RETURN
W
FRAMELESS
CABINETRY
FRAMED
CABINETRY
3
/4" (19)
TYPICAL
3
/4" (19)
TYPICAL
FILLER
VIEW
31/2" (89) finished returns will be visible and should be finished to match cabinetry.
DUAL STANDARD OPENING W
HD
FRONT VIEW
Two 36" Models711/2" (1816)833/4" (2127)24" (610)
For standard installations, the face frame will extend 2" (51)
beyond cabinetry. A dual installation kit is required for this
installation.
DUAL FLUSH OPENING
WHD
Two 36" Models72" (1829)841/8" (2137)26" (660)
For ush installations, the face frame will be ush with surrounding cabinetry. A dual installation kit is required for this
installation.
subzero.com | 5
SITE PREPARATION
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply within the shaded area shown
in the illustration below. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
The outlet must be checked by a qualied electrician
to be sure it is wired with the correct polarity. Verify the
outlet is properly grounded.
WARNING
Do not locate multiple portable socket-outlets, power
strip, or portable power supplies at the rear of the
appliance.
Plumbing Requirements
Installation must comply with all applicable plumbing codes.
Locate the water supply line within the shaded area shown
in the illustration below. Connect the water supply line to the
house supply with an easily accessible shut-off valve. Do
not use self-piercing valves. The water supply line must not
interfere with the installation of the anti-tip bracket.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
to the unit at all times. In this application, the water ltration
system must be bypassed by removing the lter. A copper
line is not recommended for this application.
PLUMBING REQUIREMENTS
Water Supply
Pressure35–120 psi
Excess Line for Connection36" (914)
RIGHT SIDE
OF OPENING
(2.4–8.3 bar) supplied
1
/4" OD copper, braided
stainless steel, or PEX tubing
(2.4–8.3 bar)
WARNING
Do not use an extension cord, two-prong adapter, or
remove the power cord ground prong.
7"
E
(178)
6"
(152)
751/2" (1918)
FROM FLOOR
RIGHT SIDE
OF OPENING
Electrical supply location
6"
(152)
3" (76)
AREA EXTENDS
FORWARD ON FLOOR
Water supply location
53/16"
(132)
1
/2" (13)
6 | Sub-Zero Customer Care 800.222.7820
SITE PREPARATION
Preparation
Uncrate the unit, and inspect for damage. Remove the wood
base, and discard the shipping bolts and brackets. Remove
and recycle packing materials. Do not discard the kickplate,
anti-tip bracket, and hardware.
Completely retract the front leveling legs to allow the unit to
be moved into position. The front and rear leveling legs can
be adjusted from the front once the unit is in position.
Remove the drain pan from the base of the unit to avoid
damage and to allow for proper placement of the appliance
dolly.
The grille assembly should be removed prior to moving
the unit. To remove, rotate the bottom of the grille upward.
Disconnect the network cable, then remove the center
mounting screw. Loosen the three grille bolts from the grille,
then pull the grille forward. Refer to the illustrations below.
SCREW
Doors and drawers can be removed for ease of installation.
Door and drawer removal is not required. To remove a door,
refer to the illustration below. To remove a drawer, pull the
drawer out to full-extension. Apply forward pressure to
the front of the drawer slide, and pull up and back on the
drawer handle. Refer to the illustration below.
DRAWER
SLIDE
Door removal
Drawer removal
Lift grille
BOLT
CONNECTOR
Grille removal
subzero.com | 7
INSTALLATION
Anti-Tip Bracket
WARNING
To prevent the unit from tipping forward, the anti-tip
bracket must be installed.
Use the centerline locating holes to position the anti-tip
bracket in the center of the opening. The bracket must be
positioned 24"
back of the bracket. This depth will increase to 26"
(610) from the front of the opening to the
(660) for
a ush installation. Failure to properly position the anti-tip
bracket will prevent proper engagement.
Use all anti-tip bracket hardware as instructed for wood or
concrete oors.
IMPORTANT NOTE: For wood or concrete oor applications,
if the #12 screws do not hit a wall stud or wall plate, use the
#8 screws and #12 washers with the wall anchors.
IMPORTANT NOTE: In some installations the subooring or
nished oor may necessitate angling the screws used to
fasten the anti-tip bracket to the back wall.
ANTI-TIP HARDWARE
1Anti-tip bracket
1
12#12 x 2
3
12#12 at washers
3#8–18 x 1
3Nylon Zip-it
/2" pan head screws
3
/8"–16 x 33/4" wedge anchors
1
/4" truss head screws
®
wall anchors
WOOD FLOOR APPLICATION
After properly locating the anti-tip bracket in the opening,
3
drill pilot holes
/16" (5) diameter maximum in the wall studs
or wall plate. Use the #12 screws and washers to secure
the bracket. Verify the screws penetrate through the ooring
material and into the wall studs or wall plate a minimum of
3
/4" (19). Refer to the chart and illustration below.
CONCRETE FLOOR APPLICATION
After properly locating the anti-tip bracket in the opening,
3
drill pilot holes
or wall plate. Drill
a minimum of 1
washers to secure the bracket to the wall, and use the
/16" (5) diameter maximum in the wall studs
3
/8" (10) diameter holes into the concrete
1
/2" (38) deep. Use the #12 screws and
3
/8"
wedge anchors to secure the bracket to the oor. Verify the
screws penetrate the wall studs or wall plate a minimum of
3
/4" (19). Refer to the chart and illustration below.
ANTI-TIP BRACKET PLACEMENT
36" Model173/4" (451)
48" Model233/4" (603)
A
CENTERLINE
LOCATING HOLES
Anti-tip bracket
8 | Sub-Zero Customer Care 800.222.7820
WALL PLATE
SUBFLOORING
Wood oor
A
WOOD FLOOR
A
FINISHED
FLOORING
A
WALL PLATE
SUBFLOORING
CONCRETE
FLOOR
Concrete oor
A
FINISHED
FLOORING
11/2"(38)
min
INSTALLATION
Anti-Tip Bracket
CONCRETE WEDGE ANCHOR INSTALLATION
1 Drill a
3
/8" (10) diameter hole any depth exceeding the
minimum embedment. Clean the hole or drill additional
depth to accommodate the drill nes.
2 Assemble the washer and nut ush with the end of
anchor to protect threads. Drive the anchor through the
material to be fastened until the washer is ush with the
surface material.
3 Expand the anchor by tightening the nut 3–5 turns past
hand-tight position or to 25 foot-pounds of torque.
WARNING
Verify there are no electrical wires or plumbing in the
area which the screws could penetrate.
CAUTION
Always wear safety glasses and use other necessary
protective devices or apparel when installing or working
with anchors.
Anchors are not recommended for use in lightweight
masonry material such as block or brick, or for use in
new concrete which has not had sufcient time to cure.
The use of core drills is not recommended to drill holes
for the anchors.
subzero.com | 9
INSTALLATION
Placement
CAUTION
Before moving the unit into position, secure doors and
drawers closed, and protect any nished ooring.
WARNING
When positioning the appliance, ensure the supply
cord is not trapped or damaged.
Use an appliance dolly to move the unit near the opening.
If the unit has been on its back or side, it must stand upright
for a minimum of 24 hours before connecting power.
Plug the power cord into the grounded outlet, and roll the
unit into position. Verify the anti-tip bracket is properly
engaged.
Water Line
Approximately 3' (.9 m) of 1/4" plastic tubing is connected to
the unit with a preassembled
under the unit. The water line tting connection kit, provided
with the unit, contains a
connection to the household water line.
Purge the water line prior to nal connection to the unit. This
will remove any debris that may be present in the tubing
from installing the new water line.
Place the sleeve and nut on the water line, and fasten to the
connection at the end of the tubing. Do not over tighten.
Check all water line ttings for leaks. Verify the drain pan
can be installed and removed without interference with the
water line.
IMPORTANT NOTE: If a reverse osmosis system is used, it
is recommended the water ltration system be bypassed by
removing the lter.
IMPORTANT NOTE: Water lines cannot be exposed to
freezing temperatures.
WARNING
Connect to potable water supply only.
1
/4" compression connection
1
/4" compression union tting for
10 | Sub-Zero Customer Care 800.222.7820
INSTALLATION
Alignment
LEVELING
Once the unit is in position, turn the front leveling legs
clockwise to adjust the height. The rear height adjustment
3
can be made from the front of the roller base. Using a
3
socket, turn the
/8" hex bolt clockwise to raise the unit or
/8"
counterclockwise to lower. Use the lowest torque setting
when using a power drill. Do not turn the rear leveling legs
by hand. Refer to the illustration below.
When the unit is properly leveled, door and drawer adjustments are less likely to be necessary.
IMPORTANT NOTE: Level the unit to the oor, not the sur-
rounding cabinetry. This could affect the operation of the
unit, such as door closing.
WARNING
To reduce the possibility of the unit tipping forward, the
front leveling legs must be in contact with the oor.
REAR
ADJUSTMENT
Leveling
FRONT
LEVELING LEG
subzero.com | 11
INSTALLATION
Alignment
DOOR ADJUSTMENT
The doors are adjustable in and out, up and down, and side
to side. In-and-out and up-and-down adjustments are made
on the door. Side-to-side adjustments are made on the
cabinet hinges. To make any adjustments, remove the door
and hinge pins. Refer to the illustration below.
In-and-Out and Up-and-Down Adjustment:
1 Place the door on a protected work surface, then loosen
the two upper hinge mounting screws.
2 Remove the two lower hinge mounting screws, then
remove the lower hinge.
3 Remove the positioning screw from the bottom of the
door, then use the adjustment pin to make up-and-down
and in-and-out adjustments. Refer to the illustration
1
below. Each vertical hole location adjusts the door
(1)
. The slotted holes allow for in-and-out adjustment.
4 Once the adjustments are made, install and tighten the
/32"
positioning screw.
Side-to-Side Adjustment:
1 Loosen the two mounting screws on the upper and/or
lower cabinet hinge. Refer to the illustration below.
2 Use the Allen wrench provided to rotate the adjustment
screw.
3 Verify the hinge is parallel to the side of the unit, then
tighten the mounting screws.
4 Install the hinge pins and door, then verify the door
alignment.
HINGE
SCREW
ADJUSTMENT
SCREW
Door removal
HINGE
PIN
DOOR HINGE
Door adjustment
POSITIONING
SCREW
ADJUSTMENT
PIN
Cabinet hinge adjustment
12 | Sub-Zero Customer Care 800.222.7820
INSTALLATION
Alignment
DRAWER ADJUSTMENT
Up-and-Down Adjustment:
1 Use a hex wrench to turn the up-and-down adjustment
screw counterclockwise to raise and clockwise to lower.
Refer to the illustration below.
Side-to-Side Adjustment:
1 Use a hex wrench to turn the adjustment screw. Refer to
the illustration below.
2 Both drawer slides must be adjusted equally to achieve
movement. For example, if the right slide adjustment
screw rotated clockwise, rotate the left slide screw
equally counterclockwise.
Tilt Adjustment:
1 Loosen the side and the bottom, center screws. Refer to
the illustration below.
2 Remove the screw from the corner of the drawer that is
out of adjustment.
Completion
ANCHORING
After the unit has been leveled and door and drawer adjustment completed, anchor the unit to the opening to ensure a
proper t and secure installation.
To Anchor the Unit:
1 Loosen the mounting bracket screws at the top of the
unit, then slide the mounting brackets to the side until
they contact the sides of the opening. Install additional
blocking if necessary. Refer to the illustration below.
2 Secure the brackets with the anchoring screws provided,
then tighten the mounting bracket screws.
ANCHORING
SCREWS
3 Move the drawer front in or out by hand.
4 Install the screw into the bottom of the drawer. Each hole
location adjusts the door in or out by
5 Tighten the side and bottom, center screws.
SIDE-TO-SIDE
ADJUSTMENT
UP-AND-DOWN
ADJUSTMENT
LOOSEN
Drawer adjustment
Drawer tilt adjustment
1
/32" (1).
REMOVE
LOOSEN
Anchoring
BRACKET SCREWS
subzero.com | 13
INSTALLATION
Completion
Install the grille assembly and check for proper t. Reconnect the network cable. Refer to page 6. Attach the network
cable to the grille using the cable ties provided.
Reinstall the drain pan and verify it is in the proper position.
Install the kickplate using the screws to attach it to the
brackets on the inside of each roller base. Refer to the illustration below. The kickplate must be removable for service.
The oor cannot interfere with removal.
Install the leg covers.
For initial start up, touch and hold
POWER on either
external touch display, located on the grille.
WATER FILTER BYPASS
If the water ltration system will not be used, it can be
bypassed by removing the water lter.
To Remove the Water Filter:
1 To access the water lter, rotate the bottom of the grille
upward.
2 To remove the lter, rotate counterclockwise one-quarter
turn, then pull out. Refer to the illustration below.
WATER FILTER
Kickplate installation
Water lter removal
14 | Sub-Zero Customer Care 800.222.7820
Loading...
+ 30 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.