SUB-ZERO®is a registered trademark of Sub-Zero, Inc.
As you follow these instruc tions, you will notice WARNING and CAUTION symbols. This blocked information is impor tant for the safe and efficient installation of Sub-Zero equipment. There are two types of potential hazards that may occur during installation.
Another footnote we would like to identify is IMPORTANT NOTE: This highlights informa­tion that is especially relevant to a problem­free installation.
signals a situation where minor injury or product damage may occur if you do not follow instructions.
states a hazard that may cause serious injury or death if precautions are not followed.
CONTENTS
Installation Recommendations 5
Installation Specifications 6
Installation Instructions 9
Installation Checklist 22
Service Information 23
Features and specifications indicated herein and on the website are subject to change at any time without notice. Check our website, subzero.com, for the most up-to-date specifications.
5
TOOLS AND MATERIALS REQUIRED
The following is a list of tools and materials that should be available for proper installation.
Phillips screwdriver set
Slotted screwdriver set
1.2 m of 6,35 mm copper tubing and saddle valve for the water line—part #4200880 (do not use self-piercing valves)
Copper tubing cutter
Level—.6 m and 1.2 m recommended
Appliance dolly able to support 227 kg and adequate help to handle the weight of the unit
Various sized pliers
Wrench set
Allen wrench set
11 mm hex bolt nut driver
Crescent wrenches
Drill and assorted drill bits
Masonite, plywood, 3,175 mm pressed fiberboard, cardboard or other suitable material to protect finished flooring
Appropriate materials to cover and protect the home and its furnishings during installation
INSTALLATION
RECOMMENDATIONS
The importance of the installation of the Sub-Zero Integrated unit cannot be overem­phasized. Installation should be done by a qualified installer.
Before you begin the installation process, it is recommended that you read this entire Installation Instructions book. There are key details that you should take special care to observe during the installation. By reading these instructions carefully, you will make the installation process easier, problem-free and, most importantly, safe.
Any questions or problems about the installation should be directed to your Sub-Zero dealer. You can also visit our website at subzero.com.
SITE PREPARATION
Make sure that the finished rough opening where the Integrated unit is to be installed is properly prepared. Refer to the Overall Dimensions and Installation illustrations for your specific model on the following pages. Make sure that the rough opening dimensions, door and drawer clearances, electrical service and plumbing are correct for the model you are about to install.
Be sure that the plumber, electrician and cabinet installer have this information before finishing work is completed.
IMPORTANT NOTE:
The inside edges of the rough opening, as well as the sides and a portion of the backside of the decorative panels will need to be finished, as they will be exposed when the doors are open.
INTEGRATED INSTALLATION RECOMMENDATIONS
6
INTEGRATED INSTALLATION SPECIFICATIONS
INSTALLATION
Models ICB700TR, ICB700TFI and ICB700TCI
Models without an ice maker will not require the water line connection.
OVERALL DIMENSIONS
Models ICB700TR, ICB700TFI and ICB700TCI
TALL UNITS
686 mm Wide Units
Model ICB700TR
All Refrigerator
Model ICB700TFI
All Freezer with Ice Maker
Model ICB700TCI
Refrigerator | Freezer with Ice Maker
SPECIFICATIONS
Overall Dimensions
Width 686 mm Height 2032 mm Depth 610 mm
Finished Opening
Width 686 mm Height 2032 mm Depth 635 mm*
*The depth of the unit is 610 mm from the front of the unit to its back. Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 635 mm.
686
13
mm
(UNIT DIMENSION) (UNIT DIMENSION)
10
mm
337 mm
MOUNTING DETAIL
260 mm
518 mm
+
_
13 mm
ADJUSTMENT IN LEVELING LEGS
*
mm
356 mm
DOOR
MOUNTING
DETAIL
DRAWER
FRONT VIEW SIDE VIEW
21
mm
876
mm*
TOP OF ROUGH
OPENING
1995 mm*
2032 mm*
*PLACEMENT OF THE
ANTI-TIP BRACKET
SHOULD BE 610 mm
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
248 mm
102 mm
635 mm
610
mm
DOOR/ DRAWER
90˚ DOOR OPENING
DOOR/ DRAWER PANEL THICKNESS NOT INCLUDED – DIMENSION WILL VARY WITH INSTALLATION
*
TOP VIEW TOP VIEW
ANTI-TIP
38
BRACKET*
mm
343 mm 343 mm
394 mm
WATER LINE
BOTTOM ENTRY
LOCATION
686 mm
W
229 mm
CLOSED
90˚
152 mm
686 mm
38 mm
610 mm
mm*
648
mm*
TOP VIEW
DOOR/ DRAWER
CLOSED
495
MAXIMUM DOOR OPENING
WATER LINE
SIDE ENTRY
LOCATIONS
635 mm
105˚
657 mm
ANTI-TIP
BRACKET
117 mm*
686 mm
38 mm
LOCATE ELECTRICAL WITHIN
SHADED AREA
LOCATE WATER LINE
(REAR ENTRY) WITHIN
SHADED AREA
W
19
mm
76
mm
2032
mm
114 mm
mm
6
ANTI-TIP
BRACKET
E
330 mm 229 mm
64 mm
394 mm
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
E
W
SIDE VIEWFRONT VIEW
ANTI-TIP
BRACKET
WATER LINE
SIDE ENTRY
LOCATION
7
INTEGRATED INSTALLATION SPECIFICATIONS
ANTI-TIP
BRACKET*
*PLACEMENT OF THE
ANTI-TIP BRACKET
SHOULD BE 610 mm
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
635 mm
914 mm
2032
mm
686 mm
635 mm
WATER LINE
BOTTOM ENTRY
LOCATION
WATER LINE
SIDE ENTRY
LOCATIONS
38
mm
38 mm
686 mm
38 mm
508 mm
343 mm
457 mm
ANTI-TIP
BRACKET
457 mm
152 mm
TOP VIEW TOP VIEW
SIDE VIEW FRONT VIEW
WATER LINE
SIDE ENTRY
LOCATION
ANTI-TIP
BRACKET
64 mm
508 mm
19
mm
76
mm
445 mm 343 mm
ANTI-TIP
BRACKET
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
114 mm
6
mm
LOCATE WATER LINE
(REAR ENTRY) WITHIN
SHADED AREA
LOCATE ELECTRICAL WITHIN
SHADED AREA
E
W
E
W
W
INSTALLATION
Models ICB736TR and ICB736TCI
Models without an ice maker will not require the water line connection.
OVERALL DIMENSIONS
Models ICB736TR and ICB736TCI
TALL UNITS
914 mm Wide Units
Model ICB736TR
All Refrigerator
Model ICB736TCI
Refrigerator | Freezer with Ice Maker
SPECIFICATIONS
Overall Dimensions
Width 914 mm Height 2032 mm Depth 610 mm
Finished Opening
Width 914 mm Height 2032 mm Depth 635 mm*
*The depth of the unit is 610 mm from the front of the unit to its back. Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 635 mm.
914 mm
(UNIT DIMENSION) (UNIT DIMENSION)
DOOR MOUNTING
DETAIL
10
mm
mm
337 mm
13
260 mm
518 mm
DRAWER MOUNTING
DETAIL
FRONT VIEW SIDE VIEW
+
_
13 mm
ADJUSTMENT IN LEVELING LEGS
*
356 mm
610
102 mm
mm
90˚ DOOR OPENING
DOOR/ DRAWER PANEL THICKNESS NOT INCLUDED – DIMENSION WILL VARY WITH INSTALLATION
*
33
mm
876
mm*
TOP OF ROUGH
OPENING
1976 mm*
2032
mm*
248 mm
DOOR/ DRAWER
CLOSED
90˚
610 mm
mm*
TOP VIEW
DOOR/ DRAWER
CLOSED
495
mm*876
886 mm
MAXIMUM DOOR OPENING
105˚
178
mm*
8
INTEGRATED INSTALLATION SPECIFICATIONS
ANTI-TIP
BRACKET*
*PLACEMENT OF THE
ANTI-TIP BRACKET
SHOULD BE 610 mm
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
635 mm
686 mm
876 mm
686
mm
635
mm
WATER LINE
BOTTOM ENTRY
LOCATION
WATER LINE
SIDE ENTRY
LOCATIONS
38
mm
38 mm
686 mm
38 mm
394 mm
229 mm
343 mm 343 mm
ANTI-TIP
BRACKET
152 mm
TOP VIEW TOP VIEW
SIDE VIEW FRONT VIEW
WATER LINE
SIDE ENTRY
LOCATION
ANTI-TIP
BRACKET
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
114 mm
64 mm
394 mm
19
mm
76
mm
6
mm
330 mm 229 mm
ANTI-TIP
BRACKET
LOCATE WATER LINE
(REAR ENTRY) WITHIN
SHADED AREA
LOCATE ELECTRICAL WITHIN
SHADED AREA
E
W
E
W
W
INSTALLATION
Models ICB700BR, ICB700BFI and ICB700BCI
Models without an ice maker will not require the water line connection.
OVERALL DIMENSIONS
Models ICB700BR, ICB700BFI and ICB700BCI
BASE UNITS
Model ICB700BR
All Refrigerator
Model ICB700BFI
All Freezer with Ice Maker
Model ICB700BCI
Refrigerator | Freezer with Ice Maker
SPECIFICATIONS
Overall Dimensions
Width 686 mm Height 876 mm Depth 610 mm
Finished Opening
Width 686 mm Height 876 mm Depth 635 mm*
*The depth of the unit is 610 mm from the front of the unit to its back. Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 635 mm.
686
mm
(UNIT DIMENSION) (UNIT DIMENSION)
DRAWER
MOUNTING DETAIL
876
mm*
FRONT VIEW SIDE VIEW
+
_
ADJUSTMENT IN LEVELING LEGS
13
mm
mm
518 mm
10
337 mm
260 mm
13 mm
*
248 mm
102 mm
610 mm
610 mm
DRAWER CLOSED
495
mm*
657 mm
DRAWER PANEL THICKNESS NOT INCLUDED
*
TOP VIEW
9
INTEGRATED INSTALLATION INSTRUCTIONS
ELECTRICAL REQUIREMENTS
A 220-240 V AC, 50/60 Hz, 10 amp circuit breaker and electrical supply are required. A separate service, servicing only this appliance, is required.
All Integrated models are equipped with a power supply cord with a 3-prong grounding plug, which must be plugged into a mating 3-prong ground ing-type wall recep tacle. Follow all local codes and ordinances when installing the receptacle. For location of the electrical supply, refer to the Installation illustration for your unit on pages 6–8.
IMPORTANT NOTE:
A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
IMPORTANT NOTE:
The Integrated line is equipped with an appliance inlet type device. This allows easy replacement of the power cord. The appliance inlet is located on top of the unit on the compressor shroud. When replacing the power cord make sure that the replacement cord is rated HO5VV-F3G1.0 or equivalent to ensure safe operation of the appliance.
Do not use an extension cord or two­prong adapter. Electrical ground is required on this appliance. Do not remove the power supply cord ground prong.
The outlet must be checked by a qualified electrician to be sure that it is wired with the correct polarity. Verify that the outlet provides 220-240 V AC and is properly grounded.
Always shut power off at the circuit breaker before performing any installa­tion, service or maintenance.
10
INTEGRATED INSTALLATION SPECIFICATIONS
PLUMBING REQUIREMENTS
For Integrated models with an automatic ice maker, rough in the water supply line. Connect the 6,35 mm water line from the ice maker water valve to the copper water supply. Use an easily accessible shut-off valve between the water supply and the unit. This shut-off valve should not be installed behind the unit. Do not use self-piercing valves. A saddle valve kit (part #4200880) is avail able from your Sub­Zero dealer.
The Installation illustrations on pages 6–8 show the precise placement of the water line. When routing through the side walls, you must place the water line within 13 mm of the floor and as close as possible to the back wall.
The line must be routed around the anti-tip bracket so it clears the bracket and the leveling feet of the unit. Refer to the top view in the Installation illustration for your unit on pages 6–8. Regardless of the routing, allow for 686 mm of excess water line to remain outside the wall or floor for easy connection to the unit.
IMPORTANT NOTE:
Do not route the water supply line in front of the compressor tray. The tray must be slid forward for service.
A line filter is required when water conditions have a high sediment content. The ice maker operates on water pressure of 1.4 bar to
6.9 bar.
A reverse osmosis system can be used, provided there is a consistent water pressure of 1.4 bar to 6.9 bar supplied to the water valve at all times.
IMPORTANT NOTE:
In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently.
ACCESSORIES
Optional acces­sories are available through your Sub-Zero dealer. To obtain local dealer information, visit our website, subzero.com.
11
INTEGRATED INSTALLATION INSTRUCTIONS
PANEL CONSIDERATIONS
DOOR AND DRAWER PANELS
To install door and drawer panels, refer to the instructions under Panel Installation on page
18. You should check panel dimensions and placement before proceeding with installation of the Integrated unit. If you have questions, contact your Sub-Zero dealer or cabinet supplier. Instructions regarding sizing of the panels are provided in the Sub-Zero Design Guide.
IMPORTANT NOTE:
A portion of the backside of the decorative panels will need to be finished, as they will be exposed when the doors are open.
SIDE PANELS
Side panels for integrated models are not attached to the unit. You must securely fasten the panels to adjacent cabinets and floor.
Panels should be fastened to the floor and walls using ’L’ brackets (hardware not provided). To help you move the unit into place, rout out an area in the floor so the ’L’ bracket will sit flush with the floor level. Brackets and screws are provided for mounting the unit to adjoining cabinets and side panels. On the tall units, there are four side mounting clips on each side and on the base units, there are two per side. Side panels must be a minimum of 19 mm thick.
IMPORTANT NOTE:
For installations where you are not attaching to a side wall or you are installing two Integrated units together, you must remove the clips before moving the unit into place. After removing the clips, replace the screws in the holes and discard the clips.
Optional components are necessary for anchoring two Integrated units together. Refer to Dual Installations on page 21. Optional components are available through your Sub-Zero dealer. To obtain local dealer infor­mation, visit our website, subzero.com.
PANEL DESIGN
Additional panel design information can be found in the Sub-Zero Design Guide. Check our website at subzero.com.
12
UNPACKING AND MOVING
Uncrate the unit, remove its wood base and discard the shipping bolts that hold the wood base to the bottom of the unit. Remove all packing materials and tape.
IMPORTANT NOTE:
Do not discard the kickplate/grille, anti-tip bracket and hardware. These items will be needed for the installation.
Retract the front leveling legs to allow you to move the unit more easily during installation. You will extend the leveling legs when the unit is in its final position to reduce the possibility of the unit tipping forward.
Use an appliance dolly to move the Integrated unit. Position the dolly at the side of the unit to prevent damage to finished surfaces. Secure the door and/or drawers so they do not open while moving the unit.
ANTI-TIP BRACKET
INSTALLATION
An anti-tip bracket and hardware is provided with the Integrated unit. The anti-tip bracket must be installed on a solid base.
If you are installing the unit in a space deeper than 610 mm, be sure to locate the anti-tip bracket so that it engages the unit properly. It is important that the anti-tip bracket is placed 610 mm from the front of the unit without panels, to the the back of the anti-tip bracket. Refer to illustrations 1 and 2 below and note that for 686 mm wide units dimension A is 343 mm, and 457 mm for 914 mm wide units.
INTEGRATED INSTALLATION INSTRUCTIONS
To prevent the unit from tipping forward and provide a stable installation, the unit must be secured in place with the anti-tip blocking bracket.
Before moving the Integrated unit into position, protect any finished flooring with appropriate materials.
13
ANTI-TIP BRACKET
INSTALLATION
WOOD FLOOR APPLICATIONS
Use the six #12 x 63,5 mm wood screws and the six #12 flat washers provided. Drill pilot holes 5 mm diameter maximum, and be sure that the screws penetrate through the flooring material and into the wall plate a minimum of 19 mm. Be sure that the screws hold tight. Refer to illustration 1 below.
CONCRETE FLOOR APPLICATIONS
Use the two #10 x 95,25 mm concrete wedge anchors, two #12 x 63,5 mm wood screws and two #12 flat washers provided. Be sure that the anchors and screws hold tight. Refer to illustration 2 below.
IMPORTANT NOTE:
In some installations the subflooring or finished floor may require angling the wood screws used to fasten the anti-tip bracket to the back wall. Refer to illustrations 1 and 2.
INTEGRATED INSTALLATION INSTRUCTIONS
Make sure that there are no electrical wires or plumbing in the area which the screws could penetrate.
Illus. 1 Illus. 2
SPECIFICATIONS
Dimension A
686 mm Wide Units 343 mm 914 mm Wide Units 457 mm
Finished Flooring
Underlayment
Wall Plate
Subflooring
WOOD FLOOR
Finished Flooring
Underlayment
38
mm
CONCRETE
min
FLOOR
Wall Plate
Subflooring
14
ANTI-TIP
BLOCKING BRACKET
INSTALL CONCRETE WEDGE ANCHORS
1)
Drill a 10 mm diameter hole any depth exceeding the minimum embedment. Clean the hole or continue drilling additional depth to accommodate drill fines. Use a carbide drill bit.
2)
Assemble the washer and nut flush with the end of anchor to protect threads. Drive the anchor through the material to be fastened until the washer is flush with the surface material.
3)
Expand the anchor by tightening the nut 3–5 turns past hand-tight position or to 25 foot-pounds (34N) of torque.
POSITION THE UNIT
IMPORTANT NOTE:
On base units, the top drawer has a control cable that needs to be disconnected before removing this drawer. Refer to illustration 3 below for placement and how to disconnect this fitting.
The drawers should be placed aside until you are ready for installation of the panels. Remove the decorative top and side molding pieces and the kickplate/grille.
IMPORTANT NOTE:
If two Integrated units are installed closer than 51 mm to one another, it is necessary to use the Sub-Zero dual installa­tion heater kit (ICBTTDUAL). Refer to Dual Installations on page 21 for additional informa­tion. The heater plate from this kit must be attached to the left side exterior of the right hand unit before the units are slid into position.
INTEGRATED INSTALLATION INSTRUCTIONS
Always wear safety glasses and use other necessary protective devices or apparel when installing or working with anchors.
Anchors are not recommended for use in lightweight masonry material such as block or brick, or for use in new concrete which has not had sufficient time to cure. The use of core drills is not recommended to drill holes for the anchors.
Illus. 3
Before moving the Integrated unit into position, secure the door closed and remove the drawers.
ACCESSORIES
Optional acces­sories are available through your Sub-Zero dealer. To obtain local dealer information, visit our website, subzero.com.
15
Pre-level the unit before moving into position. This is to allow the unit to engage the anti-tip bracket properly.
Slide the unit into position, making sure the anti-tip bracket is engaged properly. Screw the front leveling legs out approximately 5 mm to make any future adjustments easier.
IMPORTANT NOTE:
When the Integrated unit is installed, the anti-tip bracket will be posi­tioned just below the engaging bracket on the unit. It is not necessary to raise the unit up so that it locks into the anti-tip bracket, but the unit must be in alignment with the anti-tip bracket.
IMPORTANT NOTE:
The floor under the Integrated unit must be at the same level as the surrounding finished floor to allow the compressor tray to be slid forward for service.
Illus. 4 Illus. 5
INTEGRATED INSTALLATION INSTRUCTIONS
Unit
On/Off
Shut off the power to the electrical outlet.
POSITION THE UNIT
Before moving the Integrated unit into position, tape down the water supply line for the ice maker so it will stay in place as you move the unit. Refer to the Installation illustration for your unit on pages 6–8 for placement of the water line.
IMPORTANT NOTE:
If for any reason the Integrated unit has been laid on its back or side, you must allow the unit to stand upright for a minimum of 24 hours before connecting power.
Plug the power supply cord into the 10 amp grounded electrical outlet. With power applied to the appliance, check for lighting and cooling before going any further. Press the key pad on the control panel. Refer to illustration 4 below for the location of the key pad for base units and illustration 5 for tall units. Once you are satisfied that the unit is operating properly, shut off power to the electrical outlet at the circuit breaker and proceed.
Unit
On/Off
16
MOLDING INSTALLATION
The decorative white molding strips for the side and top of the unit can be snapped into place. The top molding strip used on Integrated tall units, must be installed before the side molding can be attached. The top molding strip is held in place by double-sided velcro fasteners. Refer to illustration 8 below for positioning of the top molding.
Illustration 9 shows side molding installation for tall units. Installation of the side molding for base units is the same. For installations where units are side by side, refer to Dual Installations on page 21.
NOTE:
The molding strips may be painted to match the surrounding cabinetry, if you choose. Follow these easy steps:
Rough up the surface to be painted with fine grit sandpaper.
Wipe with alcohol to ensure that the surface is clean and dry.
Use an appliance or industrial grade, oil base, high gloss enamel paint.
INTEGRATED INSTALLATION INSTRUCTIONS
LEVEL THE UNIT
Level the Integrated unit by turning the front leveling legs clockwise to raise the unit, or counterclockwise to lower it. To assist you in adjusting the front leveling legs up or down, use a standard screwdriver blade and place it in the front leveling leg as shown in illustration 6 below.
The rear leveling legs are adjusted from the front of the base by turning the Phillips head screw. Refer to illustration 7.
IMPORTANT NOTE:
The rear leveling legs will only move 2 mm for every 18 revolutions on the Phillips head screw. Do not over torque. Use the lowest torque setting on any power screwdriver. Do not turn the rear leveling legs by hand. Damage will occur if you turn these legs.
Once the unit is leveled, secure the unit in place by using the side mounting clips and #8 x 12,7 mm screws provided.
To reduce the possibility of the unit tipping forward, the front leveling legs must be in contact with the floor.
Illus. 6 Illus. 7 Illus. 8
Illus. 9
Top Molding
17
In areas with water of high mineral content, the use of an in-line water filter is recom­mended. Make sure the filter is positioned and accessible for replacement when necessary.
IMPORTANT NOTE:
The ice maker will not fill with water immediately. Allow 24 hours for proper ice production. Let your customer know that the first container filled with ice should be discarded, as with any new connection there may be impurities in the ice from the water supply line.
WATER LINE CONNECTION
QUICK CONNECT WATER VALVE
For units with an ice maker, the quick connect water valve and PEX tubing are located on the right-hand side of the unit towards the bottom. Follow these instructions to connect the ice maker water line.
Attach the union fitting to the copper house water supply line. Pull the coiled gray PEX tubing with a red cap and captured metal nut toward the house water supply line. Remove and discard the red cap, then attach the tubing to the union with captured nut. Tighten all connections. Recoil the excess tubing under the unit. Refer to illustration 10 below.
IMPORTANT NOTE:
Turn on the water supply and check all fittings for leaks. Make certain the electrical harness is attached to the solenoid.
INTEGRATED INSTALLATION INSTRUCTIONS
PEX
Tubing
Illus. 10
Shut power off at the circuit breaker before making electrical connection to the solenoid, if required.
18
PANEL INSTALLATION
The integrated design uses custom wood or other decorative panels and handles provided by the customer. Stainless steel panels are available as sales accessories through your Sub-Zero dealer. To obtain local dealer infor­mation, visit our website, subzero.com.
Before beginning installation, check the panels for the proper fit and finish desired.
Door and drawer panels must be a minimum of 16 mm thick. The door panel cannot exceed 18 kg and each drawer panel must not exceed 5 kg for 686 mm wide units. For 914 mm wide units, the door panel weight limit is 24 kg and 7 kg for each drawer panel.
D-style pulls are recommended for handle hardware. Handles should be located on the opposite side from the hinge, centered on the cabinet door, and on the top center area of the drawer panel. Screw heads may have to be countersunk to ensure that the hardware does not interfere with the panels fitting flush with the unit's door or drawers.
It is recommended that the door panel of the tall unit be installed first and then the upper and lower drawer panels.
INTEGRATED INSTALLATION INSTRUCTIONS
PANEL REQUIREMENTS
Door and drawer panels must be a minimum of 16 mm thick.
The door panel cannot exceed 18 kg and each drawer panel must not exceed 5 kg for 686 mm wide units. For 914 mm wide units, the door panel weight limit is 24 kg and 7 kg for each drawer panel.
KICKPLATE/GRILLE INSTALLATION
Once your Integrated unit is secured, the kickplate/grille can be installed. There is some adjustment to the mounting assembly so that this decorative piece can fit flush with the surrounding area. Refer to illustration 11 below.
Turn power back on to the electrical outlet.
IMPORTANT NOTE:
The unit must be allowed to have ventilation through the fins of the kick­plate/grille. You may cover the solid area, but do not block the fins. The lower drawer panel may hang in front of the fins, but your base­board molding must not cover them.
IMPORTANT NOTE:
The kickplate/grille must be removed for servicing. The floor cannot interfere with removal.
NOTE:
The kickplate/grille can be painted another color, if you choose. Follow these easy steps:
Rough up the surface to be painted with fine grit sandpaper.
Wipe with alcohol to ensure that the surface is clean and dry.
Use an appliance or industrial grade, oil base, high gloss enamel paint.
Illus. 11
Illus. 12
Back Of Door Panel
Gap On Side Edges Will Vary According To Design
Bottom Of Template
Flush With Bottom
Of Door Panel
19
PANEL INSTALLATION
If you have questions, contact your Sub-Zero dealer or cabinet supplier. Additional panel information can be found in the Sub-Zero Design Guide.
DOOR PANEL INSTALLATION
Remove the two pieces of mounting hardware attached to the front of the door and set aside.
Place the door panel lying face down on a protected surface to ensure that the front is not scratched or damaged.
Position the plastic template provided flush with the lower edge of the door. Be sure you are following the exact location for the right­hand (RH) or left-hand (LH) door position. Refer to illustration 12 on page 18.
IMPORTANT NOTE:
The template has two usable sides, one side for the door and one for the drawers. Make sure you use the proper holes and side. Remember you are viewing the door panel from the back side in illustration 12 on page 18.
Once you have located the proper position for the bracket, mark the pilot holes, remove the template and drill pilot holes for mounting the bracket. It is best to start with a few holes, position the bracket, drill the remaining pilot holes and then secure the mounting bracket with the #8 x 12,7 mm screws provided. Illus­tration 13 shows the mounting hardware location for door and drawer panels.
IMPORTANT NOTE:
Dimensions in illustration 13 are based on a 3 mm reveal. A reveal of up to 6 mm is possible, but panel dimensions need to be adjusted accordingly.
INTEGRATED INSTALLATION INSTRUCTIONS
Exercise caution when drilling holes for mounting hardware. This is especially critical with inset panels.
Illus. 13
1153 mm*
287 mm
606 mm* FOR 686 mm WIDE UNITS 835 mm* FOR 914 mm WIDE UNITS
135 mm
PANEL BRACKET POSITIONING
37 mm*
132 mm
32
mm
345 mm
LH DOOR SWINGRH DOOR SWING
570 mm
32
mm 214 mm
679 mm*
FOR 686 mm WIDE UNITS
908 mm* FOR 914 mm WIDE UNITS
VIEW FROM BACK OF PANELS
*DIMENSIONS MAY VARY
424
mm*
DRAWER PANEL INSTALLATION
Remove the mounting hardware provided and set aside. As with the door panel, you should work on the back side of each drawer panel and protect the fronts of these panels.
Position the top edge of the template flush with the top edge of each drawer. For the top drawer, there is only one location for the lower mounting bracket to be placed. However, the bottom drawer allows a second option, invert­ing the lower mounting bracket, depending on the height and thickness or detail of the panel. Refer to illustration 15 below.
Secure the template in place with tape or a small clamp and mark positions for the pilot holes. Remove the template and drill the pilot holes. Place the mounting brackets in the proper location with the tabbed bracket on top and ’L’ bracket on the bottom of the panel. Fasten brackets securely with the #8 x 12,7 mm screws provided. Refer to illustration 16 below. Illustration 13 on page 17 also shows the mounting hardware location for drawer panels.
20
INTEGRATED INSTALLATION INSTRUCTIONS
PANEL REQUIREMENTS
Door and drawer panels must be a minimum of 16 mm thick.
The door panel cannot exceed 18 kg and each drawer panel must not exceed 5 kg for 686 mm wide units. For 914 mm wide units, the door panel weight limit is 24 kg and 7 kg for each drawer panel.
PANEL INSTALLATION
Before attaching the door panel to the door, place two screws in the center of each mounting position, just enough that the slotted holes on the hinge side door panel bracket will slide under the heads. These positioning screws will support the door panel during installation and adjustment. Refer to illustra­tion 14 below.
Install the door panel by engaging the tabbed bracket to the handle side of the door first and then sliding the hinge side mounting bracket onto the positioning screws on the hinge side of the door. The panel can be adjusted 6 mm up and down and side to side.
Once the door panel is in place and adjusted correctly, attach the six remaining #10 x 12,7 mm screws to the hinge side mounting bracket and install the magnetic decorative caps as shown in illustration 14.
As the reveal between cabinets and the unit decreases, the potential exists for severe finger pinching if fingers are placed in the opening when the door is closing.
Illus. 14 Illus. 15 Illus. 16
Top Of Template
Flush With Top Of
Drawer Panel
Gap On Side Edges Will Vary According To Design
Back Of
Drawer Panel
21
PANEL INSTALLATION
To help with the placement of the drawer panels, examine the lower ’L’ bracket and panel to determine the slotted holes on the bracket that will be used. Then position screws into the lower portion of the drawer that correspond with these slots. Leave these screws out just enough that the slotted holes in the bracket will slide under the heads.
With the two mounting brackets in place, install the drawer panel by engaging the top tabbed bracket first, then slide the lower ’L’ bracket onto the positioning screws. Each drawer panel can be adjusted 6 mm up and down and side to side. Fasten all screws to the lower ’L’ bracket to secure the drawer panel. Refer to illustration 16 on page 20.
IMPORTANT NOTE:
Once drawer panels have been adjusted for proper spacing, be sure to reconnect the control cable on the base unit only after you have installed the drawer. Refer to illustration 3 on page 14.
DUAL INSTALLATIONS
When two Integrated units are installed closer than 51 mm to one another, it is necessary to use the Sub-Zero dual installation heater kit (ICBBBDUAL or ICBTTDUAL). The heater plate from this kit must be attached to the left side exterior of the right hand unit before the units are slid into position.
Contact your Sub-Zero dealer for the proper components and installation instructions.
90-DEGREE DOOR STOP
All Integrated tall units have a 90-degree door stop built into the hinge system. Use the blade edge of a standard screwdriver and rotate the brass cam in the center portion of the hinge until you reach the stop. You must make this adjustment to both the bottom and top hinge. Refer to illustration 17 below.
INTEGRATED INSTALLATION INSTRUCTIONS
Illus. 17
Exercise caution when drilling holes for mounting hardware. This is especially critical with inset panels.
ACCESSORIES
Optional acces­sories are available through your Sub-Zero dealer. To obtain local dealer information, visit our website, subzero.com.
22
INSTALLATION CHECKLIST
The importance of the installation of the Sub-Zero Integrated unit cannot be overemphasized. Proper installation is the responsibility of the selling dealer or installer.
IMPORTANT NOTE:
To ensure a safe and proper installation, the following checklist should be completed by the installer to ensure that no part of the installation has been overlooked.
Advise the homeowner to fill out and return all product registration forms. This will ensure that the customer information is in our database in the event service is required.
Any questions or problems about the installa­tion should be directed to your Sub-Zero dealer. You can also visit our website at subzero.com.
INSTALLATION CHECKLIST
INSTALLATION CHECKLIST
Has the anti-tip bracket been installed properly and is it making contact with the unit?
Is the unit level? Are all leveling legs making contact with the floor?
Is the power cord plugged into a properly grounded 3-prong outlet, which has been installed in accordance with all applicable electrical codes?
Is the water supply connected for units with an automatic ice maker? Have you checked for leaks?
Has the kickplate/grille been installed properly?
Are panels attached securely and properly aligned?
Has the door been aligned for proper appearance and operation?
Have all accessories been installed?
Have any installation or service problems been noted on the product registration card? Has the registration card been mailed in?
Have stainless steel panels been inspected for any imperfections? This is to be done by the dealer or installer with the customer upon completion of the installation. NOTE: Classic, platinum and carbon stain­less steel panels are covered by a limited 60-day parts and labor warranty for cosmetic defects.
SERVICE INFORMATION
If service is necessary, maintain the quality built into your Sub-Zero unit by calling a Sub-Zero dealer.
When calling for service, you will need the model and serial number of your unit. Both numbers are listed on the product rating plate located inside the cabinet, to the left of the upper drawer.
23
If you are storing or disposing of your old refrigerator or freezer, please do it safely. Remove the doors or tightly secure the doors closed. Child entrapment accidents can be tragic.
CONTACT INFORMATION
Website: subzero.com
SERVICE INFORMATION
The information and images in this book are the copyright property of Sub-Zero, Inc. Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Sub-Zero, Inc.
©Sub-Zero, Inc. all rights reserved.
SUB-ZERO®es una marca comercial registrada de Sub-Zero, Inc.
A medida que siga estas instrucciones , encon­trará símbolos de PRECAUCI
ÓN y
ADVERTEN­CIA. Esta información es importante para instalar el equipo de Sub-Zero de forma segura y eficaz. Existen dos tipos de posibles riesgos que pueden producirse durante una instalación.
Otro tipo de información que deberá observar con atención es la que se incluye en NOTA IMPORTANTE: En esta nota se resalta la infor­mación que resulta especialmente importante para que la instalación se realice sin problemas.
indica una situación en la que se pueden sufrir heridas leves o provocar daños secundarios al producto si no se siguen las instrucciones.
indica peligro de que se produzcan heridas personales graves o incluso puede provocar la muerte si no se siguen las precauciones especificadas.
ÍNDICE
Recomendaciones de instalación 25
Especificaciones de la instalación 26
Instrucciones de instalación 29
Lista de comprobación de la instalación 42
Información de mantenimiento 43
Las características y especificaciones que se indican en esta guía y en la página Web están sujetas a cambios sin previo aviso. Visite nuestra página Web, www.sub-zero.com, para obtener las especifica­ciones más actualizadas.
25
HERRAMIENTAS Y MATERIALES NECESARIOS
A continuación se especifican las herramientas y los materiales necesarios para llevar a cabo la instalación de manera correcta.
Juego de destornilladores Phillips
Juego de destornilladores para tornillos ranurados
1,2 m de tubo de cobre de 6,35 mm y una válvula de montaje para el conducto de agua —pieza #4200880 (no utilice válvulas autoperforantes)
Instrumento especial para cortar el tubo de cobre
Se recomienda tener un nivel de 0,6 m y de 1,2 m
Unidad rodante para mover el aparato capaz de soportar 227 kg y personal para manejar el peso de la unidad
Alicates de varios tamaños
Juego de llaves
Juego de llaves Allen
Llave para tuercas hexagonales de 11 mm
Llaves ajustables (inglesas)
Taladro y varias brocas
Masonita, madera contrachapada, panel de fibra prensado de 3,175 mm, cartón u otro material adecuado para proteger el acabado del suelo
Materiales apropiados para cubrir y proteger el hogar y el mobiliario durante la instalación
RECOMENDACIONES
DE INSTALACIÓN
Debe tenerse en cuenta la importancia de la instalación de la unidad integrable de Sub­Zero. Sólo un instalador cualificado debe realizar la instalación.
Antes de comenzar el proceso de instalación, se recomienda que lea con detenimiento la guía de instrucciones de instalación. Durante la instalación, existe información importante a la que debe prestar especial atención. Si lee estas instrucciones con detenimiento, podrá llevar a cabo el proceso de instalación de forma fácil, sin problemas y, lo que es más importante, de forma segura.
Si tiene alguna pregunta o problema rela­cionado con la instalación, debe ponerse en contacto con su distribuidor de Sub-Zero. También puede visitar nuestra página Web www.sub-zero.com.
PREPARACIÓN DEL SITIO
Compruebe que la cavidad en la que se va a instalar la unidad integrable está preparada correctamente. Vea las ilustraciones Medidas totales e Instalación correspondientes a su modelo concreto en las páginas siguientes. Asegúrese de que las medidas de la cavidad, los espacios para la puerta y los cajones, la instalación eléctrica y de fontanería son correctas para el modelo que va a instalar.
Compruebe que el fontanero, el electricista y el montador de los muebles disponen de esta información antes de que finalice el trabajo de acabado.
NOTA IMPORTANTE:
Será necesario dejar acabados los bordes interiores de la cavidad, así como los laterales y una parte del lado trasero de los paneles decorativos, ya que estos elementos serán visibles al abrir las puertas.
RECOMENDACIONES DE INSTALACIÓN
INTEGRABLE
26
ESPECIFICACIONES DE INSTALACIÓN INTEGRABLE
INSTALACIÓN
Modelos ICB700TR, ICB700TFI e ICB700TCI
Los modelos que no dispongan de fabricador de cubitos de hielo no necesitan conexión de toma de agua.
MEDIDAS TOTALES
Modelos ICB700TR, ICB700TFI e ICB700TCI
UNIDADES ALTAS
Unidades con un ancho de 686 mm
Modelo ICB700TR
Todo frigorífico
Modelo ICB700TFI
Todo congelador con fabricador de cubitos de hielo
Modelo ICB700TCI
Frigorífico | Congelador con fabricador de cubitos de hielo
ESPECIFICA­CIONES
Medidas totales
Anchura 686 mm Altura 2.032 mm Fondo 610 mm
Cavidad acabada
Anchura 686 mm Altura 2.032 mm Fondo 635 mm*
*El fondo de la unidad mide 610 mm desde la parte delantera de la unidad a su parte trasera. Su diseño puede exigir que se mueva la unidad hacia atrás o los muebles hacia adelante para conseguir un ajuste de mueble empotrado. Será necesario un fondo de cavidad mínimo de 635 mm.
686 mm
(MEDIDAS DE LA UNIDAD) (MEDIDAS DE LA UNIDAD)
10
mm
337 mm
13
mm
260 mm
518 mm
AJUSTE DE ± 13 mm EN PATAS NIVELADORAS
*
356 mm
DETALLE DE
MONTAJE
DE PUERTA
DETALLE DE
MONTAJE DE CAJÓN
VISTA FRONTAL VISTA LATERAL
DE CAVIDAD
21
mm
1.995 mm*
876
mm*
PARTE
SUPERIOR
2.032 mm*
248 mm
*LA COLOCACIÓN DEL
SOPORTE ANTI-VUELCO
DEBE MEDIR 610 mm DESDE
LA PARTE DELANTERA DE LA UNIDAD SIN PANELES
A LA PARTE TRASERA
DE ESTE SOPORTE.
INSTALACIÓN ELÉCTRICA EN
EL ÁREA SOMBREADA
INSTALACIÓN DE TUBERÍA
DE AGUA (ENTRADA TRASERA)
EN EL ÁREA SOMBREADA
E
W
330 mm 229 mm
114 mm
SOPORTE
ANTI-VUELCO
6
mm
64 mm
394 mm
NOTA: EL SOPORTE ANTI-VUELCO DEBE INSTALARSE PARA
EVITAR QUE LA UNIDAD SE INCLINE HACIA DELANTE
102 mm
635 mm
19
mm
610 mm
PUERTA/CAJÓN
CERRADO
90˚
APERTURA DE PUERTA A 90°
GROSOR DE PANEL DE PUERTA/CAJÓN NO INCLUIDO – LAS MEDIDAS VARIARÁN SEGÚN LA INSTALACIÓN
*
VISTA SUPERIOR VISTA SUPERIOR
SOPORTE
38
ANTI-VUELCO*
mm
343 mm 343 mm
394 mm
UBICACIÓN DE
ENTRADA INFERIOR
DE TUBERÍA DE AGUA
686 mm
76
mm
E
W
229 mm
152 mm
W
686 mm
38 mm
2.032 mm
610 mm
495
mm*
648
mm*
APERTURA MÁXIMA DE PUERTA
VISTA SUPERIOR
UBICACIONES DE
ENTRADA LATERAL
DE TUBERÍA DE AGUA
635 mm
ANTI-VUELCO
VISTA LATERALVISTA FRONTAL
PUERTA/CAJÓN
SOPORTE
ANTI-VUELCO
SOPORTE
CERRADO
105˚
657 mm
117 mm*
686 mm
38 mm
UBICACIÓN
DE ENTRADA
LATERAL DE
TUBERÍA DE AGUA
27
ESPECIFICACIONES DE INSTALACIÓN INTEGRABLE
SOPORTE
ANTI-VUELCO*
*LA COLOCACIÓN DEL
SOPORTE ANTI-VUELCO
DEBE MEDIR 610 mm DESDE
LA PARTE DELANTERA DE LA UNIDAD SIN PANELES
A LA PARTE TRASERA
DE ESTE SOPORTE.
635 mm
914 mm
2.032 mm
686 mm
635 mm
UBICACIÓN DE
ENTRADA INFERIOR
DE TUBERÍA DE AGUA
UBICACIONES DE
ENTRADA LATERAL
DE TUBERÍA DE AGUA
38
mm
38 mm
686 mm
38 m
508 mm
343 mm
457 mm
SOPORTE
ANTI-VUELCO
457 mm
152 mm
VISTA SUPERIOR VISTA SUPERIOR
VISTA LATERALVISTA FRONTAL
UBICACIÓN
DE ENTRADA
LATERAL
DE TUBERÍA
DE AGUA
SOPORTE
ANTI-VUELCO
64 mm
508 mm
19
mm
76
mm
445 mm 343 mm
SOPORTE
ANTI-VUELCO
NOTA: EL SOPORTE ANTI-VUELCO DEBE INSTALARSE PARA
EVITAR QUE LA UNIDAD SE INCLINE HACIA DELANTE
114 mm
6
mm
INSTALACIÓN DE TUBERÍA
DE AGUA (ENTRADA TRASERA)
EN EL ÁREA SOMBREADA
INSTALACIÓN ELÉCTRICA EN
EL ÁREA SOMBREADA
E
W
E
W
W
INSTALACIÓN
Modelos ICB736TR e ICB736TCI
Los modelos que no dispon­gan de fabricador de cubitos de hielo no necesitan conexión de toma de agua.
MEDIDAS TOTALES
Modelos ICB736TR e ICB736TCI
UNIDADES ALTAS
Unidades con un ancho de 914 mm
Modelo ICB736TR
Todo frigorífico
Modelo ICB736TCI
Frigorífico | Congelador con fabricador de cubitos de hielo
ESPECIFICA­CIONES
Medidas totales
Anchura 914 mm Altura 2.032 mm Fondo 610 mm
Cavidad acabada
Anchura 914 mm Altura 2.032 mm Fondo 635 mm*
*El fondo de la unidad mide 610 mm desde la parte delantera de la unidad a su parte trasera. Su diseño puede exigir que se mueva la unidad hacia atrás o los muebles hacia adelante para conseguir un ajuste de mueble empotrado. Será necesario un fondo de cavidad mínimo de 635 mm.
mm
(MEDIDAS DE LA UNIDAD) (MEDIDAS DE LA UNIDAD)
DETALLE DE MONTAJE
DE PUERTA
10
mm
mm
337 mm
13
260 mm
518 mm
DETALLE DE MONTAJE
DE CAJÓN
VISTA FRONTAL VISTA LATERAL
AJUSTE DE ± 13 mm EN PATAS NIVELADORAS
*
914
356 mm
33
mm
876
mm*
PARTE
SUPERIOR
DE CAVIDAD
2.032 mm*
1.976 mm*
248 mm
102 mm
610 mm
610 mm
PUERTA/CAJÓN
CERRADO
90˚
APERTURA DE
PUERTA A 90°
GROSOR DE PANEL DE PUERTA/CAJÓN NO INCLUIDO – LAS MEDIDAS VARIARÁN SEGÚN LA INSTALACIÓN
*
495
mm*876
mm*
VISTA SUPERIOR
PUERTA/CAJÓN
CERRADO
105˚
886 mm
APERTURA MÁXIMA DE PUERTA
178
mm*
28
ESPECIFICACIONES DE INSTALACIÓN INTEGRABLE
SOPORTE
ANTI-VUELCO*
*LA COLOCACIÓN DEL
SOPORTE ANTI-VUELCO
DEBE MEDIR 610 mm DESDE
LA PARTE DELANTERA DE LA UNIDAD SIN PANELES
A LA PARTE TRASERA
DE ESTE SOPORTE.
635 mm
686 mm
876 mm
686 mm
635 mm
UBICACIÓN DE
ENTRADA INFERIOR
DE TUBERÍA DE AGUA
UBICACIONES DE
ENTRADA LATERAL
DE TUBERÍA DE AGUA
38
mm
38 mm
686 mm
38 mm
394 mm
229 mm
343 mm 343 mm
SOPORTE
ANTI-VUELCO
152 mm
VISTA SUPERIOR VISTA SUPERIOR
VISTA LATERALVISTA FRONTAL
UBICACIÓN DE ENTRADA LATERAL DE
TUBERÍA DE AGUA
SOPORTE
ANTI-VUELCO
NOTA: EL SOPORTE ANTI-VUELCO DEBE INSTALARSE PARA
EVITAR QUE LA UNIDAD SE INCLINE HACIA DELANTE
114 mm
64 mm
394 mm
19
mm
76
mm
6
mm
330 mm 229 mm
SOPORTE
ANTI-VUELCO
INSTALACIÓN DE TUBERÍA
DE AGUA (ENTRADA TRASERA)
EN EL ÁREA SOMBREADA
INSTALACIÓN ELÉCTRICA EN
EL ÁREA SOMBREADA
E
W
E
W
W
INSTALACIÓN
Modelos ICB700BR, ICB700BFI e ICB700BCI
Los modelos que no dispongan de fabricador de cubitos de hielo no necesitan conexión de toma de agua.
MEDIDAS TOTALES
Modelos ICB700BR, ICB700BFI e ICB700BCI
UNIDADES BASE
Modelo ICB700BR
Todo frigorífico
Modelo ICB700BFI
Todo congelador
con fabricador de cubitos de hielo
Modelo ICB700BCI
Frigorífico | Congelador con fabricador de
cubitos de hielo
ESPECIFICA­CIONES
Medidas totales
Anchura 686 mm Altura 876 mm Fondo 610 mm
Cavidad acabada
Anchura 686 mm Altura 876 mm Fondo 635 mm*
*El fondo de la unidad mide 610 mm desde la parte delantera de la unidad a su parte trasera. Su diseño puede exigir que se mueva la unidad hacia atrás o los muebles hacia adelante para conseguir un ajuste de mueble empotrado. Será necesario un fondo de cavidad mínimo de 635 mm.
686
10
mm
337 mm
13
mm
260 mm
518 mm
AJUSTE DE ± 13 mm EN PATAS NIVELADORAS
*
mm
(MEDIDAS DE LA UNIDAD) (MEDIDAS DE LA UNIDAD)
DETALLE DE
MONTAJE DE CAJÓN
876
mm*
248 mm
102
VISTA FRONTAL VISTA LATERAL
mm
610
mm
610 mm
CAJÓN CERRADO
495
mm*
VISTA SUPERIOR
GROSOR DE PANEL DE CAJÓN NO INCLUIDO
*
657 mm
29
INSTRUCCIONES DE INSTALACIÓN INTEGRABLE
REQUISITOS ELÉCTRICOS
Es necesario que la red eléctrica y el cortacir­cuitos sean de 220-240 V CA, 50/60 hercios y 10 amperios. Se necesita una instalación independiente que alimente solamente a esta unidad.
Todos los modelos integrables vienen equipa­dos con un cable eléctrico con un enchufe de 3 clavijas con conexión a tierra que debe introducirse en un enchufe de pared de igual tipo con conexión a tierra. Debe cumplir todas las normativas nacionales vigentes sobre instalaciones eléctricas y enchufes. Para conocer la ubicación de la toma eléctrica, consulte la ilustración de la instalación corres­pondiente a su unidad en las páginas 26-28.
NOTA IMPORTANTE:
No se recomienda utilizar un interruptor de circuito de fallos de conexión a tierra (GFCI), ya que puede inte­rrumpir el funcionamiento de la unidad.
NOTA IMPORTANTE:
La gama de aparatos integrables está equipada con un dispositivo de entrada. Esto permite que el cable eléctrico se pueda cambiar de forma sencilla. El orificio de entrada de los aparatos está situado en la parte superior de la unidad en el protector del compre­sor. Para cambiar el cable eléctrico, es necesario asegurarse de que el cable nuevo está clasificado HO5VV-F3G1.0 o tiene una clasificación equiva­lente que garantiza el funcionamiento seguro del aparato.
No utilice alargadores ni adaptadores. Este aparato debe conectarse a tierra. No cambie nunca la clavija de conexión a tierra del cable de alimentación.
La toma de corriente debe ser revisada por un electricista cualificado para comprobar que la conexión se ha realizado con la polaridad correcta. Compruebe que la toma de corriente suministra 220-240 voltios y que está conectada a tierra de manera correcta.
Apague siempre la corriente eléctrica en el cuadro antes de realizar la instalación o las tareas de servicio o mantenimiento.
30
ESPECIFICACIONES DE INSTALACIÓN INTEGRABLE
REQUISITOS DE FONTANERÍA
En el caso de los modelos integrables con fabricador de cubitos de hielo automático, ubique la toma de agua. Conecte el conducto de agua de 6,35 mm desde la válvula del fabricador de cubitos de hielo hasta el tubo de cobre de la toma de agua. Utilice una conexión rápida o roscada de fácil acceso entre la toma de agua y la unidad. Esta válvula no debe instalarse detrás de la unidad. No utilice conexiones autoperforantes. Puede adquirir un equipo de conexión de montaje (pieza número #4200880) a través de su distribuidor de Sub-Zero.
Las ilustraciones sobre la instalación de las páginas 26-28 muestran la colocación exacta del conducto de agua. A la hora de canalizar el agua por las paredes laterales, es necesario colocar el conducto de agua a 13 mm del suelo y lo más cerca posible de la pared trasera.
Debe canalizarse alrededor del soporte antivuelco para que salve el soporte y las patas de nivelación de la unidad. Consulte la vista superior en la ilustración sobre la instalación correspondiente a su unidad en las páginas 26-28. Sea cual sea la canalización, deje un sobrante de 686 mm del conducto de agua fuera de la pared o el suelo para que sea fácil conectarlo a la unidad.
NOTA IMPORTANTE:
No canalice la toma de agua delante de la bandeja del compresor. Es necesario que esta bandeja se pueda deslizar para sacarla en caso de avería.
Es necesario un filtro en la toma para que no afecten al aparato los sedimentos que el agua puede arrastrar en ocasiones. El fabricador de cubitos de hielo funciona con presiones de agua entre 1,4 y 6,9 bar.
Se puede utilizar un sistema de ósmosis inver­tido, siempre y cuando se proporcione siempre a la válvula de agua una presión de agua constante de entre 1,4 y 6,9 bar.
NOTA IMPORTANTE:
En algunas ocasiones, es posible que el sistema de filtrado de agua por ósmosis invertida no sea capaz de man­tener la presión de agua mínima de forma constante.
ACCESORIOS
Podrá disponer de accesorios opcionales a través de su distribuidor de Sub-Zero. Para obtener la información del distribuidor más cercano, visite nuestra página Web www.sub­zero.com