To ensure this product is installed and operated as safely
and efciently as possible, take note of the following types
of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION indicates a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specied.
BUILT-IN REFRIGERATION
Product Information
Important product information including the model and
serial number are listed on the product rating plate. The
rating plate is located at the top frame of the unit, inside the
door. Refer to the illustration below.
If service is necessary, contact Sub-Zero factory certied
service with the model and serial number. For the name
of the nearest Sub-Zero factory certied service or for
questions regarding the installation, visit the contact & support section of our website, subzero.com or call Sub-Zero
customer care at 800-222-7820.
RATING
PLATE
Tools and Materials
• Screwdrivers—standard and Phillips.
• Power drill.
• Drill bits (masonry bits required for concrete installation).
• Torx drives—T-10, 15 and 20.
• Standard Allen wrench set.
• Standard socket and wrench set.
• 2' and 4' levels.
• Tubing cutter.
1
• 3' of
• Saddle valve.
• Material to protect home, ooring and cabinetry during
/4" OD copper, braided stainless steel or PEX
tubing.
installation.
Rating plate location.
subzero.com | 3
SITE PREPARATION
Opening Dimensions
STANDARD INSTALLATION
24" (610)
OPENING
DEPTH
TOP VIEW
24" (610)
OPENING DEPTH
833/4"
(2127)
OPENING
HEIGHT
A
OPENING WIDTH
FRONT VIEWSIDE VIEW
OPENING WIDTHA
1
BI-36R, BI-36RG, BI-36F 35
/2" (902)
BI-30U, BI-30UG291/2" (749)
BI-36U, BI-36UG, BI-36UFD351/2" (902)
BI-36S351/2" (902)
BI-42S, BI-42SID, BI-42SD411/2" (1054)
BI-48S, BI-48SID, BI-48SD471/2" (1206)
If two units are installed side by side, refer to page 6.
4 | Sub-Zero Customer Care 800.222.7820
11/4"
(32)
24"
(610)
OPENING
DEPTH
TO CLEAT
CLEAT
TOP VIEW
263/16"
(665)
FLUSH
INSET
DEPTH
23/16" (56)
3" (76)
typical
11/4"
(32)
24"
(610)
OPENING
DEPTH
TO CLEAT
CLEAT
TOP VIEW
263/16"
(665)
FLUSH
INSET
DEPTH
23/16" (56)
24" (610)
OPENING
DEPTH TO
CLEAT
11/4"
(32)
23/16" (56)
CLEAT
SHADED
AREA
MUST BE
FINISHED
3" typical
(76)
4" (102)
3"(76)
typical
SITE PREPARATION
Opening Dimensions
FLUSH INSET INSTALLATION
263/16"
FLUSH
INSET
DEPTH
1
/4"
(6)
CLEAT
(665)
24" (610)
DEPTH
TO CLEAT
23/16"
(56)
11/4"
(32)
TOP VIEW
UNIT WITH
3
/4" (19) PANEL
CLEAT
DETAIL A
SIDE VIEW
24" (610)
DEPTH TO CLEAT
263/16" (665)
FLUSH INSET DEPTH
23/16"
(56)
833/4"
(2127)
HEIGHT
TO CLEAT
84"
(2134)
FLUSH
INSET
HEIGHT
11/4"
(32)
A
WIDTH TO CLEAT
B
FLUSH INSET WIDTH
DETAIL B
FRONT VIEW
11/4"
(32)
Detail A
Detail B
OPENING WIDTH AB
1
BI-36R, BI-36RG, BI-36F 35
/2" (902)38" (965)
BI-30U, BI-30UG291/2" (749)32" (813)
BI-36U, BI-36UG, BI-36UFD351/2" (902)38" (965)
BI-36S351/2" (902)38" (965)
BI-42S, BI-42SID, BI-42SD411/2" (1054)44" (1118)
BI-48S, BI-48SID, BI-48SD471/2" (1206)50" (1270)
Dimensions assume a 3/4" (19) panel thickness. If two units
are installed side by side, refer to page 7.
subzero.com | 5
SITE PREPARATION
Opening Dimensions
DUAL STANDARD INSTALLATION
(610)
24"
OPENING
DEPTH
TOP VIEW
24" (610)
OPENING DEPTH
833/4"
(2127)
OPENING
HEIGHT
OPENING WIDTH
FRONT VIEWSIDE VIEW
OPENING WIDTHA
(762) Models 59
Two 30"
3
/4" (1518)
30" (762) and 36" (914) Models 653/4" (1670)
Two 36" (914) Models 713/4" (1822)
A
A dual installation kit will be required for this installation.
6 | Sub-Zero Customer Care 800.222.7820
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.