Sub-Zero 736TR Installation Guide

I N T E G R A T E D R E F R I G E R A T I O N
I N STA L L AT I O N I N S T RU C T I O N S
O N T E N T S
C
Installation Recommendations 3
Installation Specifications 4
Installation Instructions 7
Installation Checklist 18
Service Information 19
Features and specifications indicated herein and on the website are subject to change at any time without notice. Check our website, subzero.com, for the most up-to-date specifications.
As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Sub-Zero equipment. There are two types of potential hazards that may occur during installation.
SUB-ZERO®is a registered trademark of Sub-Zero, Inc.
signals a situation where minor injury or product damage may occur if you do not follow instructions.
states a hazard that may cause serious injury or death if precautions are not followed.
Another footnote we would like to identify is IMPORTANT NOTE: This highlights informa­tion that is especially relevant to a problem­free installation.
I N T E G R AT E D I N S TA L L AT I O N R E C O M M E N D A T I O N S
I N S TA L L AT I O N
R E C O M M E N DAT I O N S
The importance of the installation of the Sub-Zero Integrated unit cannot be overem­phasized. Installation should be done by a qualified installer.
Before you begin the installation process, it is recommended that you read this entire Installation Instructions book. There are key details that you should take special care to observe during the installation. By reading these instructions carefully, you will make the installation process easier, problem-free and, most importantly, safe.
Any questions or problems about the installation should be directed to your Sub-Zero dealer or the Sub-Zero Customer Service Department at 800-222-7820. You can also visit our website at subzero.com.
S I T E P R E P A R A T I O N
Make sure that the finished rough opening where the Integrated unit is to be installed is properly prepared. Refer to the Overall Dimensions and Installation illustrations for your specific model on the following pages. Make sure that the rough opening dimensions, door and drawer clearances, electrical service and plumbing are correct for the model you are about to install.
Be sure that the plumber, electrician and cabinet installer have this information before finishing work is completed.
IMPORTANT NOTE:
The inside edges of the rough opening, as well as the sides and a portion of the backside of the decorative panels will need to be finished, as they will be exposed when the doors are open.
T O O L S A N D M A T E R I A L S R E Q U I R E D
The following is a list of tools and materials that should be available for proper installation.
Phillips screwdriver set
Slotted screwdriver set
1
4' (1.2 m) of
/4" copper tubing and saddle valve for the water line—part # 4200880 (do not use self-piercing valves)
Copper tubing cutter
Level—2' (.6 m) and 4' (1.2 m) recommended
Appliance dolly able to support 500 lbs (227 kg) and adequate help to handle the weight of the unit
Various sized pliers
Wrench set
Allen wrench set
5
/16" hex bolt nut driver
Crescent wrenches
Drill and assorted drill bits
Masonite, plywood,1/8" pressed fiberboard, cardboard or other suitable material to protect finished flooring
Appropriate materials to cover and protect the home and its furnishings during installation
Dimensions in parentheses are in millimeters unless otherwise specified.
3
TOP OF ROUGH
OPENING
789/16"*
(1995)
3
4
1
/2"
*
(
876)
14"(
356)
13
/16"
(21)
93/4"
(248)
4
"
(102)
80"*
(
2032)
27"
(
686)
24"
(
610)
*
1
/2" (
13)
+
_
A
DJUSTMENT IN LEVELING LEGS
FRONT VIEW
SIDE VIEW
(UNIT DIMENSION) (UNIT DIMENSION)
3
/8"
(
10)
131/4"
(
337)
1
/2"
(
13)
101/4"
(260)
203/8"
(518)
DOOR
MOUNTING
D
ETAIL
DRAWER
M
OUNTING DETAIL
105˚
90˚
90˚ DOOR OPENING
DOOR/ DRAWER
CLOSED
MAXIMUM DOOR OPENING
*
DOOR/ DRAWER PANEL THICKNESS NOT INCLUDED – DIMENSION WILL VARY WITH INSTALLATION
DOOR/ DRAWER
CLOSED
191/2"*
(495)25
1
/2"*
(648)
24"
(610)
257/8" (657)
45/8"*(117)
TOP VIEW
25"
(635)
27"
(686)
80"
(2032)
27"
(686)
25"
(635)
ANTI-TIP
BRACKET*
WATER LINE
BOTTOM ENTRY
LOCATION
WATER LINE
SIDE ENTRY
LOCATIONS
11/2"
(38)
11/2"
(38)
27"
(686)
11/2"
(38)
151/2"
(
394)
9"
(
229)
131/2"
(
343)
131/2"
(
343)
ANTI-TIP
BRACKET
6"
(152)
TOP VIEW TOP VIEW
SIDE VIEWFRONT VIEW
WATER LINE
SIDE ENTRY
LOCATION
ANTI-TIP
BRACKET
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
41/2"
(114)
21/2" (64)
151/2" (394)
3
/4"
(19)
3"
(76)
1
/4"
(6)
13" (330) 9"
(229)
ANTI-TIP
BRACKET
LOCATEWATER LINE
(REAR ENTRY) WITHIN
SHADED AREA
LOCATE ELECTRICAL WITHIN
SHADED AREA – ORIENT GROUND
PRONG TO RIGHT AS SHOWN
*PLACEMENT OF THE
ANTI-TIP BRACKET
SHOULD BE 24" (610)
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
T A L L U N I T S
27" (686) Wide Units
Mode l 700TR
All Refrigerator
Mode l 700TF
All Freezer
Mode l 700TFI
All Freezer with Ice Maker
Mode l 700TC
Refrigerator | Freezer
Mode l 700TCI
Refrigerator | Freezer with Ice Maker
I N T E G R AT E D I N S TA L L AT I O N S P E C I F I C A T I O N S
O V E R A L L D I M E N S I O N S
Models 700TR, 700TF(I ) and 700TC(I )
S P E C I F I C A T I O N S
Overall Dimensions
Width 27" (686)
Height 80" (2032)
Depth 24" (610)
Finished Opening
Width 27" (686)
Height 80" (2032)
Depth 25" (635)*
*The depth of the unit is 24" (610) from the front of the unit to its
I N S T A L L A T I O N
Models 700TR, 700TF(I ) and 700TC(I )
Models without an ice maker will not require the water line connection.
back. Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635).
4
I N T E G R AT E D I N S T A L L AT I O N S P E C I F I C AT I O N S
D
OOR MOUNTING
DETAIL
D
RAWER MOUNTING
DETAIL
T
OP OF
ROUGH
OPENING
77
1
3
/16"*
(1976)
341/2"*
(
876)
3
/8"
(10)
131/4"
(
337)
1
/2"
(
13)
101/4"
(260)
203/8"
(
518)
1
4"
(
356)
15/16"
(33)
93/4"
(
248)
4"
(102)
80"*
(2032)
36"
(
914)
24"
(
610)
FRONT VIEW
SIDE VIEW
(UNIT DIMENSION) (UNIT DIMENSION)
*
1
/2" (13)
+
_
ADJUSTMENT IN LEVELING LEGS
1
05˚
90˚
90˚ DOOR OPENING
D
OOR/ DRAWER
C
LOSED
MAXIMUM DOOR OPENING
D
OOR/ DRAWER
C
LOSED
1
9
1
/2"
*
(
495)
341/2"*
(876)
24"
(610)
347/8" (
886)
7"*
(
178)
*
D
OOR/ DRAWER PANEL THICKNESS NOT INCLUDED – DIMENSION WILL VARY WITH INSTALLATION
TOP VIEW
A
NTI-TIP
BRACKET*
*PLACEMENT OF THE
ANTI-TIP BRACKET
SHOULD BE 24" (610)
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
25"
(635)
36"
(914)
80"
(2032)
27"
(686)
25"
(635)
WATER LINE
BOTTOM ENTRY
LOCATION
WATER LINE
SIDE ENTRY
LOCATIONS
11/2"
(
38)
11/2"
(38)
27"
(686)
11/2"
(38)
20" (508) 131/2"
(
343)
18" (
457)
ANTI-TIP
BRACKET
18" (
457)
6"
(152)
TOP VIEW TOP VIEW
SIDE VIEW FRONT VIEW
WATER LINE
SIDE ENTRY
LOCATION
ANTI-TIP
BRACKET
21/2" (64)
20" (508)
3
/4"
(19)
3"
(76)
171/2" (445) 131/2"
(343)
ANTI-TIP
BRACKET
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
41/2"
(114)
1
/4"
(6)
LOCATEWATER LINE
(REAR ENTRY) WITHIN
SHADED AREA
LOCATE ELECTRICAL WITHIN
SHADED AREA – ORIENT GROUND
PRONG TO RIGHT AS SHOWN
O V E R A L L D I M E N S I O N S
Models 736TR and 736TC(I )
T A L L U N I T S
36" (914) Wide Units
Mode l 736TR
All Refrigerator
Mode l 736TC
Refrigerator | Freezer
Mode l 736TCI
Refrigerator | Freezer with Ice Maker
S P E C I F I C A T I O N S
Overall Dimensions
Width 36" (914)
Height 80" (2032)
Depth 24" (610)
I N S T A L L A T I O N
Models 736TR and 736TC(I )
Models without an ice maker will not require the water line connection.
millimeters unless otherwise specified.
Finished Opening
Width 36" (914)
Height 80" (2032)
Depth 25" (635)*
*The depth of the unit is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635).
5Dimensions in parentheses are in
DRAWER
M
OUNTING DETAIL
3
4
1
/2"
*
(876)
93/4"
(248)
4
"
(102)
F
RONT VIEW
S
IDE VIEW
3
/8"
(10)
131/4"
(
337)
1
/2"
(13)
101/4"
(
260)
203/8"
(
518)
27"
(686)
24"
(610)
(UNIT DIMENSION) (UNIT DIMENSION)
*
1
/2" (13)
+
_
ADJUSTMENT IN LEVELING LEGS
*
DRAWER PANEL THICKNESS NOT INCLUDED
D
RAWER CLOSED
191/2"*
(
495)
24"
(610)
2
5
7
/8" (657)
TOP VIEW
ANTI-TIP
B
RACKET*
*PLACEMENT OF THE
ANTI-TIP BRACKET
SHOULD BE 24" (610)
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
25"
(635)
27"
(686)
341/2"
(876)
27"
(686)
25"
(635)
WATER LINE
BOTTOM ENTRY
LOCATION
WATER LINE
SIDE ENTRY
LOCATIONS
11/2"
(38)
11/2"
(38)
27"
(686)
11/2"
(38)
151/2"
(394)
9"
(229)
131/2"
(
343)
131/2"
(
343)
A
NTI-TIP
BRACKET
6"
(
152)
TOP VIEW TOP VIEW
SIDE VIEW FRONT VIEW
WATER LINE
SIDE ENTRY
LOCATION
ANTI-TIP
BRACKET
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
41/2"
(114)
21/2" (64)
151/2" (394)
3
/4"
(19)
3"
(76)
1
/4"
(6)
13" (330) 9"
(229)
ANTI-TIP
BRACKET
LOCATEWATER LINE
(REAR ENTRY) WITHIN
SHADED AREA
LOCATE ELECTRICAL WITHIN
SHADED AREA – ORIENT GROUND
PRONG TO RIGHT AS SHOWN
B A S E U N I T S
Mode l 700BR
All Refrigerator
Mode l 700BF
All Freezer
Mode l 700BFI
All Freezer
ith Ice Maker
w
Mode l 700BC
Refrigerator | Freezer
Mode l 700BCI
Refrigerator | Freezer with Ice Maker
S P E C I F I C A T I O N S
I N T E G R AT E D I N S T A L L AT I O N S P E C I F I C AT I O N S
O V E R A L L D I M E N S I O N S
Models 700BR, 700BF(I ) and 700BC(I)
Overall Dimensions
Width 27" (686)
Height 34
1
/2" (876)
Depth 24" (610)
Finished Opening
Width 27" (686)
Height 34
1
/2" (876)
Depth 25" (635)*
*The depth of the unit is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635).
6
I N S T A L L A T I O N
Models 700BR, 700BF(I ) and 700BC(I)
Models without an ice maker will not require the water line connection.
Loading...
+ 14 hidden pages