I N T E G R A T E D R E F R I G E R A T I O N
I N STA L L AT I O N I N S T RU C T I O N S
O N T E N T S
C
Installation Recommendations 3
Installation Specifications 4
Installation Instructions 7
Installation Checklist 18
Service Information 19
Features and specifications indicated herein and
on the website are subject to change at any time
without notice. Check our website, subzero.com,
for the most up-to-date specifications.
As you follow these instructions, you will
notice WARNING and CAUTION symbols.
This blocked information is important for the
safe and efficient installation of Sub-Zero
equipment. There are two types of potential
hazards that may occur during installation.
SUB-ZERO®is a registered trademark of Sub-Zero, Inc.
signals a situation where minor injury or
product damage may occur if you do not
follow instructions.
states a hazard that may cause serious
injury or death if precautions are not
followed.
Another footnote we would like to identify is
IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation.
I N T E G R AT E D I N S TA L L AT I O N R E C O M M E N D A T I O N S
I N S TA L L AT I O N
R E C O M M E N DAT I O N S
The importance of the installation of the
Sub-Zero Integrated unit cannot be overemphasized. Installation should be done by a
qualified installer.
Before you begin the installation process,
it is recommended that you read this entire
Installation Instructions book. There are key
details that you should take special care to
observe during the installation. By reading
these instructions carefully, you will make the
installation process easier, problem-free and,
most importantly, safe.
Any questions or problems about the
installation should be directed to your
Sub-Zero dealer or the Sub-Zero Customer
Service Department at 800-222-7820. You can
also visit our website at subzero.com.
S I T E P R E P A R A T I O N
Make sure that the finished rough opening
where the Integrated unit is to be installed is
properly prepared. Refer to the Overall
Dimensions and Installation illustrations for
your specific model on the following pages.
Make sure that the rough opening dimensions,
door and drawer clearances, electrical service
and plumbing are correct for the model you
are about to install.
Be sure that the plumber, electrician and
cabinet installer have this information before
finishing work is completed.
IMPORTANT NOTE:
The inside edges of the
rough opening, as well as the sides and a
portion of the backside of the decorative
panels will need to be finished, as they will be
exposed when the doors are open.
T O O L S A N D M A T E R I A L S R E Q U I R E D
The following is a list of tools and materials
that should be available for proper installation.
Phillips screwdriver set
Slotted screwdriver set
1
4' (1.2 m) of
/4" copper tubing and saddle
valve for the water line—part # 4200880
(do not use self-piercing valves)
Copper tubing cutter
Level—2' (.6 m) and 4' (1.2 m)
recommended
Appliance dolly able to support 500 lbs
(227 kg) and adequate help to handle the
weight of the unit
Various sized pliers
Wrench set
Allen wrench set
5
/16" hex bolt nut driver
Crescent wrenches
Drill and assorted drill bits
Masonite, plywood,1/8" pressed fiberboard,
cardboard or other suitable material to
protect finished flooring
Appropriate materials to cover and protect
the home and its furnishings during
installation
Dimensions in parentheses are in
millimeters unless otherwise specified.
3
TOP OF
ROUGH
OPENING
789/16"*
(1995)
3
4
1
/2"
*
(
876)
14"(
356)
13
/16"
(21)
93/4"
(248)
4
"
(102)
80"*
(
2032)
27"
(
686)
24"
(
610)
*
1
/2" (
13)
+
_
A
DJUSTMENT IN LEVELING LEGS
FRONT VIEW
SIDE VIEW
(UNIT DIMENSION) (UNIT DIMENSION)
3
/8"
(
10)
131/4"
(
337)
1
/2"
(
13)
101/4"
(260)
203/8"
(518)
DOOR
MOUNTING
D
ETAIL
DRAWER
M
OUNTING DETAIL
105˚
90˚
90˚ DOOR OPENING
DOOR/ DRAWER
CLOSED
MAXIMUM DOOR OPENING
*
DOOR/ DRAWER PANEL THICKNESS NOT INCLUDED – DIMENSION WILL VARY WITH INSTALLATION
DOOR/ DRAWER
CLOSED
191/2"*
(495)25
1
/2"*
(648)
24"
(610)
257/8" (657)
45/8"*(117)
TOP VIEW
25"
(635)
27"
(686)
80"
(2032)
27"
(686)
25"
(635)
ANTI-TIP
BRACKET*
WATER LINE
BOTTOM ENTRY
LOCATION
WATER LINE
SIDE ENTRY
LOCATIONS
11/2"
(38)
11/2"
(38)
27"
(686)
11/2"
(38)
151/2"
(
394)
9"
(
229)
131/2"
(
343)
131/2"
(
343)
ANTI-TIP
BRACKET
6"
(152)
TOP VIEW TOP VIEW
SIDE VIEWFRONT VIEW
WATER LINE
SIDE ENTRY
LOCATION
ANTI-TIP
BRACKET
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
41/2"
(114)
21/2" (64)
151/2" (394)
3
/4"
(19)
3"
(76)
1
/4"
(6)
13" (330) 9"
(229)
ANTI-TIP
BRACKET
LOCATEWATER LINE
(REAR ENTRY) WITHIN
SHADED AREA
LOCATE ELECTRICAL WITHIN
SHADED AREA – ORIENT GROUND
PRONG TO RIGHT AS SHOWN
*PLACEMENT OF THE
ANTI-TIP BRACKET
SHOULD BE 24" (610)
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
T A L L U N I T S
27" (686) Wide Units
Mode l 700TR
All Refrigerator
Mode l 700TF
All Freezer
Mode l 700TFI
All Freezer
with Ice Maker
Mode l 700TC
Refrigerator | Freezer
Mode l 700TCI
Refrigerator | Freezer
with Ice Maker
I N T E G R AT E D I N S TA L L AT I O N S P E C I F I C A T I O N S
O V E R A L L D I M E N S I O N S
Models 700TR, 700TF(I ) and 700TC(I )
S P E C I F I C A T I O N S
Overall Dimensions
Width 27" (686)
Height 80" (2032)
Depth 24" (610)
Finished Opening
Width 27" (686)
Height 80" (2032)
Depth 25" (635)*
*The depth of the unit
is 24" (610) from the
front of the unit to its
I N S T A L L A T I O N
Models 700TR, 700TF(I ) and 700TC(I )
Models without an ice maker will not
require the water line connection.
back. Your design may
necessitate moving the
unit back or cabinets
forward to achieve a
flush fit. This will
require a minimum
rough opening depth
of 25" (635).
4
I N T E G R AT E D I N S T A L L AT I O N S P E C I F I C AT I O N S
D
OOR MOUNTING
DETAIL
D
RAWER MOUNTING
DETAIL
T
OP OF
ROUGH
OPENING
77
1
3
/16"*
(1976)
341/2"*
(
876)
3
/8"
(10)
131/4"
(
337)
1
/2"
(
13)
101/4"
(260)
203/8"
(
518)
1
4"
(
356)
15/16"
(33)
93/4"
(
248)
4"
(102)
80"*
(2032)
36"
(
914)
24"
(
610)
FRONT VIEW
SIDE VIEW
(UNIT DIMENSION) (UNIT DIMENSION)
*
1
/2" (13)
+
_
ADJUSTMENT IN LEVELING LEGS
1
05˚
90˚
90˚ DOOR OPENING
D
OOR/ DRAWER
C
LOSED
MAXIMUM DOOR OPENING
D
OOR/ DRAWER
C
LOSED
1
9
1
/2"
*
(
495)
341/2"*
(876)
24"
(610)
347/8" (
886)
7"*
(
178)
*
D
OOR/ DRAWER PANEL THICKNESS NOT INCLUDED – DIMENSION WILL VARY WITH INSTALLATION
TOP VIEW
A
NTI-TIP
BRACKET*
*PLACEMENT OF THE
ANTI-TIP BRACKET
SHOULD BE 24" (610)
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
25"
(635)
36"
(914)
80"
(2032)
27"
(686)
25"
(635)
WATER LINE
BOTTOM ENTRY
LOCATION
WATER LINE
SIDE ENTRY
LOCATIONS
11/2"
(
38)
11/2"
(38)
27"
(686)
11/2"
(38)
20" (508) 131/2"
(
343)
18" (
457)
ANTI-TIP
BRACKET
18" (
457)
6"
(152)
TOP VIEW TOP VIEW
SIDE VIEW FRONT VIEW
WATER LINE
SIDE ENTRY
LOCATION
ANTI-TIP
BRACKET
21/2" (64)
20" (508)
3
/4"
(19)
3"
(76)
171/2" (445) 131/2"
(343)
ANTI-TIP
BRACKET
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
41/2"
(114)
1
/4"
(6)
LOCATEWATER LINE
(REAR ENTRY) WITHIN
SHADED AREA
LOCATE ELECTRICAL WITHIN
SHADED AREA – ORIENT GROUND
PRONG TO RIGHT AS SHOWN
O V E R A L L D I M E N S I O N S
Models 736TR and 736TC(I )
T A L L U N I T S
36" (914) Wide Units
Mode l 736TR
All Refrigerator
Mode l 736TC
Refrigerator | Freezer
Mode l 736TCI
Refrigerator | Freezer
with Ice Maker
S P E C I F I C A T I O N S
Overall Dimensions
Width 36" (914)
Height 80" (2032)
Depth 24" (610)
I N S T A L L A T I O N
Models 736TR and 736TC(I )
Models without an ice maker
will not require the water line
connection.
millimeters unless otherwise specified.
Finished Opening
Width 36" (914)
Height 80" (2032)
Depth 25" (635)*
*The depth of the unit
is 24" (610) from the
front of the unit to its
back. Your design may
necessitate moving the
unit back or cabinets
forward to achieve a
flush fit. This will
require a minimum
rough opening depth
of 25" (635).
5Dimensions in parentheses are in
DRAWER
M
OUNTING DETAIL
3
4
1
/2"
*
(876)
93/4"
(248)
4
"
(102)
F
RONT VIEW
S
IDE VIEW
3
/8"
(10)
131/4"
(
337)
1
/2"
(13)
101/4"
(
260)
203/8"
(
518)
27"
(686)
24"
(610)
(UNIT DIMENSION) (UNIT DIMENSION)
*
1
/2" (13)
+
_
ADJUSTMENT IN LEVELING LEGS
*
DRAWER PANEL THICKNESS NOT INCLUDED
D
RAWER CLOSED
191/2"*
(
495)
24"
(610)
2
5
7
/8" (657)
TOP VIEW
ANTI-TIP
B
RACKET*
*PLACEMENT OF THE
ANTI-TIP BRACKET
SHOULD BE 24" (610)
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
25"
(635)
27"
(686)
341/2"
(876)
27"
(686)
25"
(635)
WATER LINE
BOTTOM ENTRY
LOCATION
WATER LINE
SIDE ENTRY
LOCATIONS
11/2"
(38)
11/2"
(38)
27"
(686)
11/2"
(38)
151/2"
(394)
9"
(229)
131/2"
(
343)
131/2"
(
343)
A
NTI-TIP
BRACKET
6"
(
152)
TOP VIEW TOP VIEW
SIDE VIEW FRONT VIEW
WATER LINE
SIDE ENTRY
LOCATION
ANTI-TIP
BRACKET
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
41/2"
(114)
21/2" (64)
151/2" (394)
3
/4"
(19)
3"
(76)
1
/4"
(6)
13" (330) 9"
(229)
ANTI-TIP
BRACKET
LOCATEWATER LINE
(REAR ENTRY) WITHIN
SHADED AREA
LOCATE ELECTRICAL WITHIN
SHADED AREA – ORIENT GROUND
PRONG TO RIGHT AS SHOWN
B A S E U N I T S
Mode l 700BR
All Refrigerator
Mode l 700BF
All Freezer
Mode l 700BFI
All Freezer
ith Ice Maker
w
Mode l 700BC
Refrigerator | Freezer
Mode l 700BCI
Refrigerator | Freezer
with Ice Maker
S P E C I F I C A T I O N S
I N T E G R AT E D I N S T A L L AT I O N S P E C I F I C AT I O N S
O V E R A L L D I M E N S I O N S
Models 700BR, 700BF(I ) and 700BC(I)
Overall Dimensions
Width 27" (686)
Height 34
1
/2" (876)
Depth 24" (610)
Finished Opening
Width 27" (686)
Height 34
1
/2" (876)
Depth 25" (635)*
*The depth of the unit
is 24" (610) from the
front of the unit to its
back. Your design may
necessitate moving the
unit back or cabinets
forward to achieve a
flush fit. This will
require a minimum
rough opening depth
of 25" (635).
6
I N S T A L L A T I O N
Models 700BR, 700BF(I ) and 700BC(I)
Models without an ice maker
will not require the water line
connection.