Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is
a poison you cannot see or smell.
(California Proposition 65)(CPSC 16 CFR Part 1407)
WARNING:
The engine exhaust from this product contains
chemicals known to the State of California to
cause cancer, birth defects or other reproductive
harm.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Only use OUTSIDE and
far away from windows,
doors, and vents.
(California only)
AIR INDEX
To show compliance with California emission regulations, a hangtag has been provided
displaying the Air Index level and durability period of this engine.
The Air Index level defines how clean an engine’s exhaust is over a period of time. A bar
graph scaled from “0” (most clean) to “10” (least clean) is used to show an engine’s Air Index
level. A lower Air Index level represents cleaner exhaust from an engine.
The period of time (in hours) that the Air Index level is measured is known as the durability
period. Depending on the size of the engine, a selection of time periods can be used to
measure the Air Index level (see below).
Descriptive TermApplicable to Emissions Durability Period
Moderate - 50 hours (engine from 0 to 80 cc)
125 hours (engine greater than 80 cc)
Intermediate-125 hours (engine from 0 to 80 cc)
250 hours (engine greater than 80 cc)
Extended-300 hours (engine from 0 to 80 cc)
500 hours (engine greater than 80 cc)
1000 hours (225 cc and greater)
Notice : This hangtag must remain on this engine or piece of equipment, and only be
removed by the ultimate purchaser before operation.
Notice : FEDERAL EMISSION COMPONENT DEFECT WARRANTY and CALIFORNIA EMISSION CONTROL
WARRANTY are applicable to only those engines/ generators complied with EPA (Environmental
Protection Agency) and CARB (California Air Resources Board) emission regulations in the U.S.A.
Notice : To the engines/generators exported to and used in the countries other than the U.S.A., warranty service
shall be performed by the distributor in each country in
engine/generator warranty policy as applicable.
accordance with the standard SUBARU
FOREWORD
Thank you very much for purchasing a SUBARU GENERATOR.
This manual covers operation and maintenance of the SUBARU GENERATOR.
This SUBARU GENERATOR can be used for general electrical equipments, appliances, lamps, tools
as an AC power source. With regards to DC application, the terminals are used only for charging 12
volt battery.
Never use this generator for any other purposes.
Please take a moment to familiarize yourself with the proper operation and maintenance procedures in
order to maximize the safe and efficient use of this product.
Keep this owner’s manual at hand, so that you can refer to it at any time.
Due to constant efforts to improve our products, certain procedures and specifications are subject to
change without notice.
When ordering spare parts, always give us the SERIAL NUMBER (SER No.) of your Product.
Please fill in the following blanks after checking the production number on your product.
(Location of label is different depending on the product model.)
Please make sure you review each precaution carefully.
Pay special attention to statement preceded by the following words.
DANGER
ENGLISHFRANÇAISEESPAÑOL
WARNING
CAUTION
WARNING
Do not operate the generator near gasoline or gaseous fuel because of the potential
danger of explosion or fire.
Do not fill the fuel tank with fuel while the engine is running. Do not smoke or use open
flame near the fuel tank. Be careful not to spill fuel during refueling.
If fuel is spilt, wipe it off and let dry before starting the engine.
WARNING
Do not place in flammables near the generator.
Be careful not to place fuel, matches, gunpowder, oily cloths, straw, trash, or any other in flammables near the
generator.
WARNING
Do not operate the generator inside a room, cave, tunnel, or other insufficiently
ventilated area.
Always operate it in a well-ventilated area, otherwise the engine may become
overheated, and the poisonous carbon monoxide gas, an odorless, colorless, poison
gas, contained in the exhaust gas will endanger human lives.
Operate generator only outdoors and far from open windows, doors, ventilation intakes
and other openings.
Keep the generator at least 1 meter (3 feet) away , including overhead, from any
structure or building use.
“DANGER” indicates a possibility of death or serious injury if instructions
are not followed.
“WARNING” indicates a strong possibility of severe personal injury or loss of
life if instructions are not followed.
“CAUTION” indicates a possibility of personal injury or equipment damage
if instructions are not followed.
1m
1m
WARNING
Do not enclose the generator nor cover it with a box.
The generator has a built-in forced air cooling system, and may become overheated if it is enclosed.
If generator has been covered to protect it from the weather during non use, be sure to remove it and keep it well away
from the area during generator use.
WARNING
Operate the generator on a level surface.
It is not necessary to prepare a special foundation for the generator.
However, the generator will vibrate on an irregular surface, so choose a level place without surface irregularities.
If the generator is tilted or moved during operation, fuel may spill and / or the generator may tip over, causing a
hazardous situation.
Proper lubrication cannot be expected if the generator is operated on a steep incline or slope. In such a case, piston
seizure may occur even if the oil is above the upper level.
WARNING
Pay attention to the wiring or extension cords from the generator to the connected device.
If the wire is under the generator or in contact with a vibrating part, it may break and possibly cause a
fire, generator burnout, or electric shock hazard.
Replace damaged or worn cords immediately.
WARNING
Do not operate in rain, in wet or damp conditions, or with wet hands.
The operator may suffer severe electric shock if the generator is wet due to rain or snow.
-
-
1
WARNING
If wet, wipe and dry it well before starting. Do not pour water directly over the generator, nor wash it with water.
WARNING
Be extremely careful that all necessary electrical grounding procedures are followed during each and every use.
Failure to do so can be fatal.
WARNING
Do not contact the generator to a commercial power line. Connection to a commercial power line may
short circuit the generator and ruin it or cause electric shock hazard.
Use the transfer switch for connecting to domestic circuit.
WARNING
No smoking while handling the battery. The battery emits flammable hydrogen gas,
which can explode if exposed to electric arcing or open flame.
Keep the area well-ventilated and keep open flames/sparks away when handling the battery.
WARNING
Engine becomes extremely hot during and for some time after operation.
Keep combustible materials well away from generator area.
Be very careful not to touch any parts of the hot engine especially the muffler area or serious
burns may result.
WARNING
Keep children and all bystanders at a safe distance from work areas.
WARNING
It is absolutely essential that you know the safe and proper use of the power tool or appliance that you intend to use.
All operators must read, understand and follow the tool/appliance owners manual. Tool and appliance applications and
limitations must be understood. Follow all directions given on labels and warnings. Keep all instruction manuals and
literature in a safe place for future reference.
WARNING
Use only "LISTED" extension cords.
When a tool or appliance is used outdoors, use only extension cords marked "For Outdoor Use". Extension cords,
when not in use should be stored in a dry and well ventilated area.
ENGLISHFRANÇAISEESPAÑOL
WARNING
Always switch off generator's AC circuit breaker and disconnect tools or appliances when not in use, before servicing,
adjusting, or installing accessories and attachments.
CAUTION
Make sure the engine is stopped before starting any maintenance, servicing or repair.
Make sure maintenance and repair of the generator set are performed by properly trained personnel only.
CAUTION
: PRECAUTIONS ON THE HANDLING OF THE WARNING LABEL
Warning labels are affixed to our engines with regard to particularly serious dangers.
When using the engines, please use them safely after carefully reading the instruction manual and understanding the
dangers.
Warning Label Exclusively for the United States and Canada
Specifications are subject to change without notice.
mL (cu.in.)
L (U.S.gal)
L (U.S.gal)
mm (in.)
Brush-less, self-exciting,
2-poles, single phase
169 (10.31) 211 (12.88) 265 (16.17)404 (24.65)
11.2 (3.0)22.0 (5.8
0.6 (0.16)1.0 (0.26)1.2 (0.32)
650 (25.6)
(815 (32.1))*1
70 (154.4)
(73 (161) )*2
+ 0.03
0
mm (0.0047
Note : Adjust the valve clearance while the engine is cold.
0.12
Brush, self-exciting,
2-poles, single phase
(875 (34.4) )*1
84.4 (186.1)
(87.4 (192.7))*2
+ 0.0012
0
in.)
710 (28.0)
93.5 (206.2)
(96.5 (212.8 ))*2
)
NOTE
*1: ( ) shows dimensions with Battery frame.
*2: ( ) shows dry weight with Electric starter.
-
-
3
3. COMPONENTS
RGX2900, RGX3600, RGX4800
Fuel strainer
(
Fuel valve
Recoil starter
handle
)
Recoil starter
Fuel tank
Tank cap
Fuel gauge
Oil drain plug
ENGLISHFRANÇAISEESPAÑOL
Control panel
Engine switch
Oil gauge (oil filler)
Spark plug cap
Muffler cover
Choke lever
Air cleaner
Exhaust outlet
-
-
4
RGX6500, RGX7500
ENGLISHFRANÇAISEESPAÑOL
Fuel strainer
(Fuel valve)
Recoil starter
handle
Recoil starter
Fuel tank
Tank cap
Fuel gauge
Control panel
Engine switch
Oil gauge (oil filler)
Oil drain plug
Choke lever
Muffler cover
Exhaust outlet
-
-
5
Spark plug cap
Air cleaner
CONTROL PANEL
RGX2900, RGX3600, RGX4800
(RGX4800)
(w/Starter motor)
Key switch
ENGLISHFRANÇAISEESPAÑOL
Engine
switch
AC receptacle 20A
AC receptacle 30A
DC output
terminal
DC circuit
breaker
AC receptacle 30A
Pilot lamp
Idel control switch
(RGX2900)(RGX3600)
AC
receptacle
20A
Pilot lamp
Hour meter
AC
receptacle
30A
AC receptacle 20A
Full power switch
AC breaker
Pilot lamp
Hour meter
AC circuit
breaker
Earth(ground
terminal
AC receptacle 30A
Full power switch
)
Hour
meter
AC circuit
breaker
DC output
terminal
DC circuit
breaker
AC circuit
breaker
Earth
(
ground
terminal
DC circuit
)
-
6
-
DC output
terminal
breaker
Idel control
switch
Earth
(
ground
terminal
)
RGX6500, RGX7500
ENGLISHFRANÇAISEESPAÑOL
(RGX6500, 7500 w/Starter motor)
Key switch
Engine switch
AC receptacle
30A
AC receptacle
20A
Idel control
switch
Full power
switch
Earth (ground)
terminal
Pilot lamp
AC receptacle
30A
Hour meter
AC circuit
breaker
DC circuit
breaker
DC output
terminal
-
-
7
4. PRE-OPERATION CHECKS
CHECK ENGINE OIL
Before checking or refilling oil, be sure
generator is located on stable and level
surface with engine stopped.
■
Remove oil filler cap and check the
engine oil level.
■
If oil level is below the lower level line,
refill with suitable oil (see table) to
upper level line. Do not screw in the oil
filler cap when checking oil level.
■
Change oil if contaminated.
(See "How-To" Maintenance.)
Use 4-stroke automotive detergent
oil of API service class SE or
higher grade (SG, SH or SJ is
recommended). SAE 10W-30
or 10W-40 is recommended for
general, all-temperature use. If
single viscosity oil is used, select
the appropriate viscosity for the
average temperature in your area.
Single grade
Multigrade
Ambient
temperature
-
-
8
5W
10W
20W
#20
10W
-
10W
#30
#40
30
-
40
Loading...