Studer MBC 12-06/1, MBC 12-15/1, MBC 24-03/1, MBC 24-08/1, MBC 24-32/1 User Manual

517/MBC User manual (En-Fr-De-Sp) 1 / 2
BATTERY CHARGER MBC
Description
This charger is made for all t ypes of lead­acid chargeable batteries, including Gel­batteries. It i s a ful ly automatic charger with an UI charging characteristic. The charger can permanently be conne cted to the battery without the risk of overcharging. When the battery is fully charged the charger automatically switches over to the floating charging (yellow and green LED lit, 13.8/2 7.6 V). This will continue until the charger is switched off. The c harger automatically starts the mains charging mode after a mains-break (yellow L ED lit 14.4/28.8 V). The charger is waterproof (IP65).
Concerned models
Range Battery Voltage
MBC 12-06/1
12 Vdc
MBC 12-15/1
MBC 24-03/1
24 Vdc
MBC 24-08/1
MBC 24-32/1
Dimensions
Range l x w x h [mm]
MBC 12-06/1 155 x 80 x 36 MBC 12-15/1 195 x 100 x 47 MBC 24-03/1 155 x 80 x 36 MBC 24-08/1 195 x 100 x 47 MBC 24-32/1 245 x 157 x 47
Installation
The charger can simply be placed in any position on a clean and dry s urface using 4 screws or bolts. Connect the red wire to the positive battery terminal and the black wire to the negati ve battery termi nal. Connect the mains cable to a 230/115 Vac mains voltage outlet.
Trouble shooting
Check the mains powers to the
charger
Check the “car fuse” on the charger’s
battery cable
If the charger still doesn’t work, please
contact your dealer
STUDER Innotec MBC – User Manual
517/MBC User manual (En–Fr–De–Sp) 2 / 2
Technical specifications
Parameters
Mains
1-phase 230 V (100-260 V) 40-60 Hz. At 110 V mains voltage the charging current is approximately 40 % of the nominal power.
Consumption standby on mains side
30 mA (50 mA for the MBC 24-32/1)
Efficiency >85 % (>90 % for the MBC 24-32/1)
Secondary fuse “Car fuse” protection against reverse polarity on connected battery.
Short circuit proof Without blowing the secondary fuse
Standby consumption on battery side
<2 mA (<0.1 mA for the MBC 24-32/1)
Mains charging
Yellow LED lit (14.4/28.8 V). Maximum 20 hours charging time. Switch to maintenance charging when current is ~5 % of rated current.
Floating charging Yellow and green LED lit. Battery is fully charged (13.8/27.6 V)
After mains break
Charger starts at 14.4/28.8 V, without battery or load the charger starts at 13.8/27.6 V
Protection class IP65 (waterproof)
Safety class
Class 1 for the MBC 12-15/1; MBC 24-08/1; MBC 24-32/1
Class 2 (no earth in the mains cable) for the MBC 12-06/1; MBC 24­03/1
Operation temperature -25 °C to +50 °C
Temperature protection Switches off at 60 °C and starts again at 50 °C
Information
In accordance with the following EN-norms:
EN60 335-1, EN60 335-2-29, EN 55 014, 55104, EN60 555-2, EN 60555-3. Swedish SS433077 (Vibration).
Warning
Batteries can generate explosive gases – avoid open flames or sparks. It is not allowed modifying the mains cable!
Loading...