Studer D19 MasterSync Operating Instructions Manual

Studer D19 MasterSync
Sync Generator/Distributor
Operating Instructions
MasterSync
D19 SERIES
INTERN
POWER
REFERENCE SAMPLING RATE
ND
48 K
32 K
INTERN
EXTERN
48 K
44.1 K
AES / EBU
VIDEO WCLK
44.1 K
WARN FAIL
Prepared and edited by: STUDER Professional Audio AG Technical Documentation Althardstrasse 30 CH-8105 Regensdorf - Switzerland
STUDER is a registered trade mark of STUDER Professional Audio AG, Regensdorf
Copyright by STUDER Professional Audio AG
Printed in Switzerland
Order no. 10.27.4501 (Ed. 0900)
Subject to change
SAFETY / SECURITE / SICHERHEIT
I
To reduce the risk of electric shock, do not remove covers (or back). No user-serviceable parts inside. Refer servicing to qualified service personnel.
Afin de prévenir un choc électrique, ne pas enlever les couvercles (où l’arrière) de l’appareil. Il ne se trouve à l’intérieur aucune pièce pouvant être réparée par l’usager.
Um die Gefahr eines elektrischen Schlages zu vermeiden, ent­fernen Sie keine Geräteabdeckungen (oder die Rückwand). Überlassen Sie Wartung und Reparatur qualifiziertem Fachper­sonal.
This symbol is intended to alert the user to presence of uninsulated “dangerous voltage” within the apparatus that may be of sufficient magnitude to constitute a risk of electric shock to a person.
Ce symbole indique à l'utilisateur qu'il existent à l'intérieur de l'ap­pareil des “tensions dangereuses”. Ces tensions élevées entrainent un risque de choc électrique en cas de contact.
Dieses Symbol deutet dem Anwender an, dass im Geräteinnern die Gefahr der Berührung von “gefährlicher Spannung” besteht. Die Grösse der Spannung kann zu einem elektrischen Schlag führen.
This symbol is intended to alert the user to the presence of important instructions for operating and maintenance in the enclo­sed documentation.
Ce symbole indique à l’utilisateur que la documentation jointe con­tient d'importantes instructions concernant le fonctionnement et la maintenance.
Dieses Symbol deutet dem Anwender an, dass die beigelegte Do­kumentation wichtige Hinweise für Betrieb und Wartung enthält.
CAUTION: Lithium battery. Danger of explosion by incorrect handling. Re-
place by battery of the same make and type only.
ATTENTION: Pile au lithium. Danger d'explosion en cas de manipulation incor-
recte. Ne remplacer que par un modèle de même type.
ACHTUNG: Explosionsgefahr bei unsachgemässem Auswechseln der Lithium-
batterie. Nur durch den selben Typ ersetzen.
ADVARSEL: Lithiumbatterei. Eksplosinsfare. Udskinftning ma kun foretages af
en sagkyndig of som beskrevet i servicemanualen (DK).
SAFETY / SECURITE / SICHERHEIT
II
FIRST AID
(in case of electric shock)
1. Separate the person as quickly as possible from the electric power source:
• by switching off the equipment
• or by unplugging or disconnec­ting the mains cable
• pushing the person away from the power source by using dry in­sulating material (such as wood or plastic).
After having sustained an elec-
tric shock, always consult a doctor.
WARNING!
DO NOT TOUCH THE PERSON OR HIS CLOTHING BEFORE THE POWER IS TURNED OFF, OTHERWISE YOU STAND THE RISK OF SUSTAINING AN ELECTRIC SHOCK AS WELL!
2. If the person is unconscious:
• check the pulse,
• reanimate the person if respirati­on is poor,
• lay the body down, turn it to one side, call for a doctor immed­iately.
PREMIERS SECOURS
(en cas d'électrocution)
1. Si la personne est dans l'impos­sibilité de se libérer:
• Couper l'interrupteur principal
• Couper le courant
• Repousser la personne de l'appa­reil à l'aide d'un objet en matière non conductrice (matière pla­stique ou bois)
Après une électrocution, toujours
consulter un médecin.
ATTENTION!
NE JAMAIS TOUCHER UNE PERSONNE QUI EST SOUS TENSION, SOUS PEINE DE SUBIR EGALEMENT UNE ELECTROCUTION.
2. En cas de perte de connaissance de la personne électrocutée:
• Controller le pouls
• Si nécessaire, pratiquer la respi­ration artificielle
• Placer l'accidenté sur le flanc et consulter un médecin.
ERSTE HILFE
(bei Stromunfällen)
1. Bei einem Stromunfall die be­troffene Person so rasch wie möglich vom Strom trennen:
• Ausschalten des Gerätes
• Ziehen oder Unterbrechen der Netzzuleitung
• Betroffene Person mit isoliertem Material (Holz, Kunststoff) von der Gefahrenquelle wegstossen
Nach einem Stromunfall sollte
immer ein Arzt aufgesucht wer­den.
ACHTUNG!
EINE UNTER SPANNUNG STE­HENDE PERSON DARF NICHT BERÜHRT WERDEN. SIE KÖN­NEN DABEI SELBST ELEKTRI­SIERT WERDEN!
2. Bei Bewusstlosigkeit des Verun­fallten:
• Puls kontrollieren,
• bei ausgesetzter Atmung künst­lich beatmen,
• Seitenlagerung des Verunfallten vornehmen und Arzt verstän­digen.
SICHERHEIT / SAFETY
III
Installation
Vor der Installation des Gerätes müssen die hier aufge­führten und auch die weiter in dieser Anleitung mit bezeichneten Hinweise gelesen und während der Installation und des Betriebes beachtet werden. Untersuchen Sie das Gerät und sein Zubehör auf allfälli­ge Transportschäden. Ein Gerät, das mechanische Beschädigung aufweist oder in welches Flüssigkeit oder Gegenstände eingedrungen sind, darf nicht ans Netz angeschlossen oder muss sofort durch Ziehen des Netzsteckers vom Netz getrennt wer­den. Das Öffnen und Instandsetzen des Gerätes darf nur von Fachpersonal unter Einhaltung der geltenden Vor­schriften durchgeführt werden.
Falls dem Gerät kein konfektioniertes Netzkabel beiliegt, muss dieses durch eine Fachperson unter Verwendung der mitgelieferten Kabel-Gerätedose IEC320/C13 oder IEC320/C19 und unter Berücksichti­gung der einschlägigen, im geweiligen Lande geltenden Bestimmungen angefertigt werden; siehe unten. Vor Anschluss des Netzkabels an die Netzsteckdose muss überprüft werden, ob die Stromversorgungs- und Anschlusswerte des Gerätes (Netzspannung, Netz­frequenz) innerhalb der erlaubten Toleranzen liegen. Die im Gerät eingesetzten Sicherungen müssen den am Gerät angebrachten Angaben entsprechen. Ein Gerät mit einem dreipoligen Gerätestecker (Gerät der Schutzklasse I) muss an eine dreipolige Netzsteckdose angeschlossen und somit das Gerätegehäuse mit dem Schutzleiter der Netzinstallation verbunden werden (Für Dänemark gelten Starkstrombestimmungen, Abschnitt
107).
Installation
Before you install the equipment, please read and adhere to the following recommendations and all sections of these instructions marked with .
Check the equipment for any transport damage.
A unit that is mechanically damaged or which has been penetrated by liquids or foreign objects must not be con­nected to the AC power outlet or must be immediately disconnected by unplugging the power cable. Repairs must only be performed by trained personnel in accor­dance with the applicable regulations.
Should the equipment be delivered without a matching mains cable, the latter has to be prepared by a trained person using the attached female plug (IEC320/C13 or IEC320/C19) with respect to the applicable regulations in your country - see diagram below.
Before connecting the equipment to the AC power outlet, check that the local line voltage matches the equipment rating (voltage, frequency) within the admissible toleran­ce. The equipment fuses must be rated in accordance with the specifications on the equipment.
Equipment supplied with a 3-pole appliance inlet (equip­ment conforming to protection class I) must be connected to a 3-pole AC power outlet so that the equipment cabinet is connected to the protective earth conductor of the AC supply (for Denmark the Heavy Current Regulations, Section 107, are applicable).
Female plug (IEC320), view from contact side:
L live; brown National American Standard: Black N neutral; blue White PE protective earth; green and yellow green
Connecteur femelle (IEC320), vue de la face aux contacts:
L phase; brun Standard national américain: Noir N neutre; bleu Blanc PE terre protective; vert et jaune Vert
Ansicht auf Steckkontakte der Kabel-Gerätesteckdose (IEC320):
L Phase; braun USA-Standard: Schwarz N Nulleiter; blau Weiss PE Schutzleiter; gelb/grün grün
SICHERHEIT / SAFETY
IV
Zugentlastung für den Netzanschluss
Zum Verankern von Steckverbindungen ohne mechani­sche Verriegelung (z.B. IEC-Kaltgerätedosen) empfehlen wir die folgende Anordnung:
Vorgehen: Der mitgelieferte Kabelhalter ist selbstkle­bend. Bitte beachten Sie bei der Montage die folgenden Regeln:
1. Der Untergrund muss sauber, trocken und frei von Fett, Öl und anderen Verunreinigungen sein. Tempe­raturbereich für optimale Verklebung: 20...40° C.
2. Entfernen Sie die Schutzfolie auf der Rückseite des Kabelhalters und bringen sie ihn mit kräftigem Druck an der gewünschten Stelle an. Lassen sie ihn unbela­stet so lange wie möglich ruhen – die maximale Kle­bekraft ist erst nach rund 24 Stunden erreicht.
3. Die Stabilität des Kabelhalters wird erhöht, wenn Sie ihn zusätzlich verschrauben. Zu diesem Zweck liegen ihm eine selbstschneidende Schraube sowie eine M4­Schraube mit Mutter bei.
4. Legen Sie das Kabel gemäss Figur in den Halter ein und pressen Sie die Klemme kräftig auf, bis das Kabel fixiert ist.
Mains connector strain relief
For anchoring connectors without a mechanical lock (e.g. IEC mains connectors), we recommend the following arrangement:
Procedure: The cable clamp shipped with your unit is auto-adhesive. If mounting, please follow the rules be­low:
1. The surface to be adhered to must be clean, dry, and free from grease, oil or other contaminants. Best ap­plication temperature range is 20...40° C.
2. Remove the plastic protective backing from the rear side of the clamp and apply it firmly to the surface at the desired position. Allow as much time as possible for curing. The bond continues to develop for as long as 24 hours.
3. For improved stability, the clamp can be fixed with a screw. For this purpose, a self-tapping screw and an M4 bolt and nut are included.
4. Place the cable into the clamp as shown in the illus­tration above and firmly press down the internal top cover until the cable is fixed.
UMGEBUNGSBEDINGUNGEN / AMBIENT CONDITIONS
V
Lufttemperatur und Feuchtigkeit
Allgemein
Die Betriebstauglichkeit des Gerätes oder Systems ist unter folgenden Umgebungsbedingungen gewährleistet:
EN 60721-3-3, Set IE32, Wert 3K3.
Diese Norm umfasst einen umfassenden Katalog von Parame­tern; die wichtigsten davon sind: Umgebungstemperatur +5...+40 °C; rel. Luftfeuchtigkeit 5...85% – d.h. weder Kon­densation noch Eisbildung; abs. Luftfeuchtigkeit 1...25 g/m³; Temperatur-Änderungsrate < 0,5 °C/min. In den folgenden Abschnitten wird darauf näher eingegangen. Unter den genannten Bedingungen startet und arbeitet das Gerät oder System problemlos. Ausserhalb dieser Spezifikatio­nen möglicherweise auftretende Probleme sind in den folgen­den Abschnitten beschrieben.
Umgebungstemperatur
Geräte und Systeme von Studer sind allgemein für einen Um­gebungstemperaturbereich (d.h. Temperatur der eintretenden Kühlluft) von +5...+40 °C ausgelegt. Bei Installation in einem Schrank muss der vorgesehene Luftdurchsatz und dadurch die Konvektionskühlung gewährleistet sein. Folgende Tatsachen sind dabei zu berücksichtigen:
1. Die zulässige Umgebungstemperatur für den Betrieb der Halbleiter-Bauelemente beträgt 0 °C bis +70 °C (commercial temperature range for operation).
2. Der Luftdurchsatz der Anlage muss gewährleisten, dass die austretende Kühlluft ständig kühler ist als 70 °C.
3. Die mittlere Erwärmung der Kühlluft soll 20 K betragen, die maximale Erwärmung an den heissen Komponenten darf somit um weitere 10 K höher liegen.
4. Zum Abführen einer Verlustleistung von 1 kW bei dieser zulässigen mittleren Erwärmung ist eine Luftmenge von 2,65 m³/min notwendig. Beispiel: Für ein Rack mit einer Leistungsaufnahme P = 800 W ist eine Kühlluftmenge von 0,8 * 2,65 m³/min nötig, entspre- chend 2,12 m³/min.
5. Soll die Kühlfunktion der Anlage (z.B. auch bei Lüfter­Ausfall oder Bestrahlung durch Spotlampen) überwacht wer­den, so ist die Temperatur der Abluft unmittelbar oberhalb der Einschübe an mehreren Stellen im Rack zu messen; die An­sprechtemperatur der Sensoren soll 65 bis 70 °C betragen.
Reif und Tau
Das unversiegelte System (Steckerpartien, Halbleiteranschlüs­se) verträgt zwar leichte Eisbildung (Reif). Mit blossem Auge sichtbare Betauung führt jedoch bereits zu Funktionsstörungen. In der Praxis kann mit einem zuverlässigen Betrieb der Geräte bereits im Temperaturbereich ab –15 °C gerechnet werden, wenn für die Inbetriebnahme des kalten Systems die folgende allgemeine Regel beachtet wird: Wird die Luft im System abgekühlt, so steigt ihre relative Feuchtigkeit an. Erreicht diese 100%, kommt es zu Nieder­schlag, meist in der Grenzschicht zwischen der Luft und einer kühleren Oberfläche, und somit zur Bildung von Eis oder Tau an empfindlichen Systemstellen (Kontakte, IC-Anschlüsse etc.). Ein störungsfreier Betrieb mit interner Betauung, unabhängig von der Temperatur, ist nicht gewährleistet.
Air temperature and humidity
General
Normal operation of the unit or system is warranted under the following ambient conditions defined by:
EN 60721-3-3, set IE32, value 3K3.
This standard consists of an extensive catalogue of parameters, the most important of which are: ambient temperature +5... +40° C, relative humidity 5...85% – i.e. no formation of con­densation or ice; absolute humidity 1...25 g/m³; rate of tem­perature change < 0,5 °C/min. These parameters are dealt with in the following paragraphs. Under these conditions the unit or system starts and works without any problem. Beyond these specifications, possible problems are described in the following sections.
Ambient temperature
Units and systems by Studer are generally designed for an ambient temperature range (i.e. temperature of the incoming air) of +5...+40 °C. When rack mounting the units, the intended air flow and herewith adequate cooling must be provided. The following facts must be considered:
1. The admissible ambient temperature range for operation of the semiconductor components is 0 °C to +70 °C (commercial temperature range for operation).
2. The air flow through the installation must provide that the outgoing air is always cooler than 70 °C.
3. Average heat increase of the cooling air shall be 20 K, allowing for an additional maximum 10 K increase at the hot components.
4. In order to dissipate 1 kW with this admissible average heat increase, an air flow of 2,65 m³/min is required.
Example: A rack dissipating P = 800 W requires an air flow of 0,8 * 2,65 m³/min which corresponds to 2,12 m³/min.
5. If the cooling function of the installation must be moni­tored (e.g. for fan failure or illumination with spot lamps), the outgoing air temperature must be measured directly above the modules at several places within the rack. The trigger tempera­ture of the sensors should be 65 to 70 °C.
Frost and dew
The unsealed system parts (connector areas and semiconductor pins) allow for a minute formation of ice or frost. However, formation of dew visible with the naked eye will already lead to malfunctions. In practice, reliable operation can be expected in a temperature range above –15 °C, if the following general rule is considered for putting the cold system into operation:
If the air within the system is cooled down, the relative humid­ity rises. If it reaches 100%, condensation will arise, usually in the boundary layer between the air and a cooler surface, to­gether with formation of ice or dew at sensitive areas of the system (contacts, IC pins, etc.). Once internal condensation occurs, troublefree operation cannot be guaranteed, independ­ent of temperature.
UMGEBUNGSBEDINGUNGEN / AMBIENT CONDITIONS
VI
Vor der Inbetriebnahme muss das System auf allfällige interne Betauung oder Eisbildung überprüft werden. Nur bei sehr leichter Eisbildung kann mit direkter Verdunstung (Sublimati­on) gerechnet werden; andernfalls muss das System im abge­schalteten Zustand gewärmt und getrocknet werden. Das System ohne feststellbare interne Eisbildung oder Betau­ung soll möglichst homogen (und somit langsam) mit eigener Wärmeleistung aufgewärmt werden; die Lufttemperatur der Umgebung soll ständig etwas tiefer als diejenige der Syste­mabluft sein. Ist es unumgänglich, das abgekühlte System sofort in warmer Umgebungsluft zu betreiben, so muss diese entfeuchtet sein. Die absolute Luftfeuchtigkeit muss dabei so tief sein, dass die relative Feuchtigkeit, bezogen auf die kälteste Oberfläche im System, immer unterhalb 100% bleibt. Es ist dafür zu sorgen, dass beim Abschalten des Systems die eingeschlossene Luft möglichst trocken ist (d.h. vor dem Ab­schalten im Winter den Raum mit kalter, trockener Luft belüf­ten und feuchte Gegenstände, z.B. Kleider, entfernen). Die Zusammenhänge sind im folgenden Klimatogramm er­sichtlich. Zum kontrollierten Verfahren gehören Thermometer und Hygrometer sowie ein Thermometer innerhalb des Sy­stems. Beispiel 1: Ein Ü-Wagen mit einer Innentemperatur von 20 °C und 40% relativer Luftfeuchtigkeit wird am Abend abgeschal­tet. Sinkt die Temperatur unter +5 °C, bildet sich Tau oder Eis. Beispiel 2: Ein Ü-Wagen wird morgens mit 20 °C warmer Luft von 40% relativer Luftfeuchtigkeit aufgewärmt. Auf Teilen, die kälter als +5 °C sind, bildet sich Tau oder Eis.
Before putting into operation, the system must be checked for internal formation of condensation or ice. Only with a minute formation of ice, direct evaporation (sublimation) may be ex­pected; otherwise the system must be heated and dried while switched off. A system without visible internal formation of ice or condensa­tion should be heated up with its own heat dissipation, as ho­mogeneously (and subsequently as slow) as possible; the ambi­ent temperature should then always be lower than the outgoing air. If it is absolutely necessary to operate the system immediately within warm ambient air, this air must be dehydrated. In such a case, the absolute humidity must be so low that the relative humidity, related to the coldest system surface, always remains below 100%. Ensure that the enclosed air is as dry as possible when powe­ring off (i.e. before switching off in winter, aerate the room with cold, dry air, and remove humid objects as clothes from the room). These relationships are visible from the following climatogram. For a controlled procedure, thermometer and hygrometer as well as a thermometer within the system will be required.
Example 1: An OB-van having an internal temperature of 20 °C and rel. humidity of 40% is switched off in the evening. If temperature falls below +5 °C, dew or ice will be forming. Example 2: An OB-van is heated up in the morning with air of 20 °C and a rel. humidity of 40%. On all parts being cooler than +5 °C, dew or ice will be forming.
WARTUNG / MAINTENANCE
VII
Wartung und Reparatur
Durch Entfernen von Gehäuseteilen, Abschirmungen etc. werden stromführende Teile freigelegt. Deshalb müssen u.a. die folgenden Grundsätze beachtet werden: Eingriffe in das Gerät dürfen nur von Fachpersonal unter Einhaltung der geltenden Vorschriften vorgenommen werden. Vor Entfernen von Gehäuseteilen muss das Gerät ausge­schaltet und vom Netz getrennt werden. Bei geöffnetem, vom Netz getrenntem Gerät dürfen Teile mit gefährlichen Ladungen (z. B. Kondensatoren, Bild­röhren) erst nach kontrollierter Entladung, heiße Bauteile (Leistungshalbleiter, Kühlkörper etc.) erst nach deren Abkühlen berührt werden.
Bei Wartungsarbeiten am geöffneten, unter Netz­spannung stehenden Gerät dürfen blanke Schaltungsteile und metallene Halbleitergehäuse weder direkt noch mit nichtisoliertem Werkzeug berührt werden. Zusätzliche Gefahren bestehen bei unsachgemässer Handhabung besonderer Komponenten:
Explosionsgefahr bei Lithiumzellen, Elektrolyt-Kon­densatoren und Leistungshalbleitern
Implosionsgefahr bei evakuierten Anzeigeeinheiten
Strahlungsgefahr bei Lasereinheiten (nichtioni- sierend), Bildröhren (ionisierend)
Verätzungsgefahr bei Anzeigeeinheiten (LCD) und Komponenten mit flüssigem Elektrolyt.
Solche Komponenten dürfen nur von ausgebildetem Fachpersonal mit den vorgeschriebenen Schutzmitteln (u.a. Schutzbrille, Handschuhe) gehandhabt werden.
Maintenance and Repair
The removal of housing parts, shields, etc. exposes ener­gized parts. For this reason the following precautions should be observed: Maintenance should only be performed by trained per­sonnel in accordance with the applicable regulations. The equipment should be switched off and disconnected from the AC power outlet before any housing parts are removed. Even if the equipment is disconnected from the power, parts with hazardous charges (e.g. capacitors, picture tubes) must not be touched until they have been properly discharged. Touch hot components (power semicon­ductors, heat sinks, etc.) only when cooled off.
If maintenance is performed on a unit that is opened and switched on, no uninsulated circuit components and me­tallic semiconductor housings must be touched neither with your bare hands nor with uninsulated tools. Certain components pose additional hazards:
Explosion hazard from lithium batteries, electrolytic capacitors and power semiconductors
Implosion hazard from evacuated display units
Radiation hazard from laser units (non-ionizing), pic­ture tubes (ionizing)
Caustic effect of display units (LCD) and such compo­nents containig liquid electrolyte.
Such components should only be handled by trained per­sonnel who are properly protected (e.g. safety goggles, gloves).
WARTUNG / MAINTENANCE
VIII
Elektrostatische Entladung (ESD) bei Wartung und Reparatur
ATTENTION:
ATTENTION:
ACHTUNG:
Viele ICs und andere Halbleiter sind empfindlich gegen elektrostatische Entladung (ESD). Unfachgerechte Be­handlung von Baugruppen mit solchen Komponenten bei Wartung und Reparatur kann deren Lebensdauer dra­stisch vermindern. Bei der Handhabung der ESD-empfindlichen Kompo­nenten sind u.a. folgende Regeln zu beachten:
• ESD-empfindliche Komponenten dürfen ausschliess­lich in dafür bestimmten und bezeichneten Ver­packungen gelagert und transportiert werden.
• Unverpackte, ESD-empfindliche Komponenten dürfen nur in dafür eingerichteten Schutzzonen (EPA, z.B. Gebiet für Feldservice, Reparatur- oder Serviceplatz) gehandhabt und nur von Personen berührt werden, die durch ein Handgelenkband mit Seriewiderstand mit dem Massepotential des Reparatur- oder Service­platzes verbunden sind. Das gewartete Gerät wie auch Werkzeug, Hilfsmittel, EPA-taugliche (elektrisch halb­leitende) Arbeits-, Ablage- und Bodenmatten müssen ebenfalls mit diesem Potential verbunden sein.
• Die Anschlüsse der ESD-empfindlichen Komponenten dürfen unkontrolliert weder mit elektrostatisch auflad­baren (Gefahr von Spannungsdurchschlag), noch mit metallischen Oberflächen (Schockentladungsgefahr) in Berührung kommen.
• Um undefinierte transiente Beanspruchung der Kom­ponenten und deren eventuelle Beschädigung durch unerlaubte Spannung oder Ausgleichsströme zu ver­meiden, dürfen elektrische Verbindungen nur am ab­geschalteten Gerät und nach dem Abbau allfälliger Kondensatorladungen hergestellt oder getrennt wer­den.
Electrostatic Discharge (ESD) during Maintenance and Repair
Observe precautions for handling devices sensitive to electrostatic discharge!
Respecter les précautions d’usage concernant la mani­pulation de composants sensibles à l’électricité statique!
Vorsichtsmassnahmen bei Handhabung elektrostatisch entladungsgefährdeter Bauelemente beachten!
Many ICs and semiconductors are sensitive to electrosta­tic discharge (ESD). The life of components containing such elements can be drastically reduced by improper handling during maintenance and repair work.
Please observe the following rules when handling ESD sensitive components:
• ESD sensitive components should only be stored and transported in the packing material specifically provi­ded for this purpose.
• Unpacked ESD sensitive components should only be handled in ESD protected areas (EPA, e.g. area for field service, repair or service bench) and only be tou­ched by persons who wear a wristlet that is connected to the ground potential of the repair or service bench by a series resistor. The equipment to be repaired or serviced and all tools, aids, as well as electrically se­miconducting work, storage and floor mats should also be connected to this ground potential.
• The terminals of ESD sensitive components must not come in uncontrolled contact with electrostatically chargeable (voltage puncture) or metallic surfaces (discharge shock hazard).
• To prevent undefined transient stress of the compo­nents and possible damage due to inadmissible volta­ges or compensation currents, electrical connections should only be established or separated when the equipment is switched off and after any capacitor charges have decayed.
WARTUNG / MAINTENANCE
IX
SMD-Bauelemente
Der Austausch von SMD-Bauelementen ist ausschliess­lich geübten Fachleuten vorbehalten. Für verwüstete Pla­tinen können keine Ersatzansprüche geltend gemacht werden. Beispiele für korrekte und falsche SMD­Lötverbindungen in der Abbildung weiter unten.
Bei Studer werden keine handelsüblichen SMD-Teile bewirtschaftet. Für Reparaturen sind die notwendigen Bauteile lokal zu beschaffen. Die Spezifikationen von Spezialbauteilen finden Sie in der Serviceanleitung.
SMD Components
SMDs should only be replaced by skilled specialists. No warranty claims will be accepted for circuit boards that have been ruined. Proper and improper SMD soldering joints are depicted below.
Studer does not keep any commercially available SMDs in stock. For repair the corresponding devices should be purchased locally. The specifications of special compo­nents can be found in the service manual.