STIEBEL ELTRON SHC 10, SHC 10 GB Eltron, SHC 15 Stiebel, SHC 15 GB Eltron Operation And Installation

OPERATION AND INSTALLATION UTILISATION ET INSTALLATION GEBRUIK EN INSTALLATIE OBSLUHA A INSTALACE
OBSŁUGA I INSTALACJA
ЭКСПЛУАТАЦИЯ И УСТАНОВКА
Sealed unvented (pressurised) small water heater | Petit chauffe-eau ECS (sous pression) | Gesloten (drukvaste), kleine warmwaterboiler | | Malý tlakový zásobník teplé vody | Mały, ciśnieniowy, pojemnościowy ogrzewacz | Малогабаритный
накопительный водонагреватель закрытого типа (напорный)
» SHC 10 » SHC 10 GB Eltron » SHC 15 Stiebel » SHC 15 GB Eltron
CONTENTS | SPECIAL INFORMATION
SPECIAL INFORMATION
OPERATION
1. General information �����������������������������������������3
1.1 Safety instructions ����������������������������������������������� 3
1.2 Other symbols in this documentation ����������������������� 3
1.3 Units of measurement ������������������������������������������ 3
2. Safety ���������������������������������������������������������� 3
2.1 Intended use ������������������������������������������������������ 3
2.2 General safety instructions ������������������������������������ 4
2.3 Test symbols ������������������������������������������������������ 4
3. Appliance description ���������������������������������������4
3.1 Settings ������������������������������������������������������������ 4
4. Cleaning, care and maintenance ���������������������������5
5. Troubleshooting ����������������������������������������������5
INSTALLATION
6. Safety ���������������������������������������������������������� 5
6.1 General safety instructions ������������������������������������ 5
6.2 Instructions, standards and regulations �������������������� 5
7. Appliance description ���������������������������������������5
7.1 Standard delivery ������������������������������������������������ 5
7.2 Accessories �������������������������������������������������������� 5
8. Preparations �������������������������������������������������� 6
8.1 Installation site ��������������������������������������������������� 6
9. Installation ���������������������������������������������������� 6
9.1 Appliance installation ������������������������������������������� 6
9.2 Safety valve installation ���������������������������������������� 6
9.3 Water connection ������������������������������������������������ 7
9.4 Power supply ����������������������������������������������������� 7
10. Commissioning �����������������������������������������������8
10.1 Initial start-up ���������������������������������������������������� 8
10.2 Recommissioning ������������������������������������������������ 8
11. Settings �������������������������������������������������������8
11.1 Setting the temperature limit ��������������������������������� 8
12. Shutdown �����������������������������������������������������8
13. Troubleshooting ����������������������������������������������8
13.1 Activate high limit safety cut-out ����������������������������� 9
14. Maintenance ��������������������������������������������������9
14.1 Checking the safety valve �������������������������������������� 9
14.2 Draining the appliance ����������������������������������������� 9
14.3 Opening the appliance ������������������������������������������ 9
14.4 Removing the flanged immersion heater and temperature controller/ high limit safety cut-out �������� 9
14.5 Checking the protective anode and replacing if necessary ��������������������������������������������������������� 10
14.6 Fitting the flanged immersion heater and temperature controller/ high limit safety cut-out ������� 10
14.7 Descaling the appliance ��������������������������������������� 10
14.8 Replacing the power cable ����������������������������������� 10
14.9 Checking the earth conductor �������������������������������� 10
15. Specification ������������������������������������������������ 11
15.1 Dimensions and connections ��������������������������������� 11
15.2 Wiring diagram ������������������������������������������������� 11
15.3 Heat-up diagram ������������������������������������������������ 11
15.4 Country-specific approvals and certifications ������������� 11
15.5 Extreme operating and fault conditions ������������������� 11
15.6 Details on energy consumption ������������������������������ 12
15.7 Data table �������������������������������������������������������� 12
GUARANTEE
ENVIRONMENT AND RECYCLING
SPECIAL INFORMATION
- The appliance may be used by children aged8 and older and persons with reduced physical, sensory or mental capabilities or a lack of ex­perience and know-how, provided that they are supervised or they have been instructed on how to use the appliance safely and have understood the resulting risks. Children must never play with the appliance. Children must never clean the ap­pliance or perform user maintenance unless they are supervised.
- When permanently connected to the power sup­ply using a dedicated junction box, the appliance must be able to be isolated from the mains power supply by an isolator that disconnects all poles with at least 3mm contact separation.
- The power cable may only be replaced (for exam­ple if damaged) by a qualified contractor author­ised by the manufacturer, using an original spare part.
- Secure the appliance as described in chapter "In­stallation/ Installation".
- Observe the maximum permissible pressure (see chapter "Installation/ Specification/ Data table").
- Drain the appliance as described in chapter "In­stallation/ Maintenance/ Draining the appliance".
- The appliance is pressurised. During the heat-up process, expansion water will drip from the safety valve.
- Regularly activate the safety valve to prevent it from becoming blocked, e.g. by limescale deposits.
2 | SHC 10 | SHC 15 www.stiebel-eltron.com
OPERATION
General information
- Install a type-tested safety valve in the cold water supply line. Depending on the supply pressure, you may also need a pressure reducing valve.
- Size the drain pipe so that water can drain off un­impeded when the safety valve is fully opened.
- Fit the drain pipe of the safety valve with a con­stant downward slope and in a room free from the risk of frost.
- The safety valve drain must remain open to the atmosphere.
OPERATION
1. General information
The chapters "Special Information" and "Operation" are intended for both the user and qualified contractors.
The chapter "Installation" is intended for qualified contractors.
Note
Read these instructions carefully before using the appli­ance and retain them for future reference. Pass on the instructions to a new user if required.
1.1.3 Keywords
KEYWORD Meaning
DANGER Failure to observe this information will result in serious
WARNING Failure to observe this information may result in serious
CAUTION Failure to observe this information may result in non-seri-
injury or death.
injury or death.
ous or minor injury.
1.2 Other symbols in this documentation
Note
General information is identified by the adjacent symbol.
Read these texts carefully.
Symbol Meaning
!
This symbol indicates that you have to do something. The ac-
tion you need to take is described step by step.
Material losses (appliance damage, consequential losses and environmen­tal pollution)
Appliance disposal
1.3 Units of measurement
Note
All measurements are given in mm unless stated oth­erwise.
ENGLISH
1.1 Safety instructions
1.1.1 Structure of safety instructions
KEYWORD Type of risk
!
Here, possible consequences are listed that may result from failure to observe the safety instructions.
Steps to prevent the risk are listed.
1.1.2 Symbols, type of risk
Symbol Type of risk
!
Injury
Electrocution
Burns (burns, scalding)
2. Safety
2.1 Intended use
This sealed unvented (pressurised) appliance is intended for heat­ing domestic hot water. The appliance can supply one or more draw-off points.
This appliance is intended for domestic use. It can be used safely by untrained persons. The appliance can also be used in a non-do­mestic environment, e.g. in a small business, as long as it is used in the same way.
Any other use beyond that described shall be deemed inappropri­ate. Observation of these instructions and of instructions for any accessories used is also part of the correct use of this appliance.
www.stiebel-eltron.com SHC 10 | SHC 15 | 3
OPERATION
Appliance description
2.2 General safety instructions
WARNING Burns During operation, the tap and safety valve can reach temperatures in excess of 60°C. There is a risk of scalding at outlet temperatures in ex­cess of 43°C.
WARNING Injury
!
The temperature selector should only be removed by a qualified contractor.
WARNING Injury
!
The appliance may be used by children aged 8 and older and persons with reduced physical, sensory or mental capabilities or a lack of experience and know-how, pro­vided that they are supervised or they have been in­structed on how to use the appliance safely and have understood the resulting risks. Children must never play with the appliance. Children must never clean the ap­pliance or perform user maintenance unless they are supervised.
Where children or persons with limited physical, sensory or men­tal abilities are allowed to use this appliance, we recommend a permanent temperature limit. A qualified contractor can set this limit.
Material losses
!
The user should protect the appliance, the water pipes, the safety valve and the tap against frost.
3. Appliance description
The appliance constantly keeps the water content available at the preselected temperature. The appliance switches on automatically as soon as its temperature falls below the set value.
Subject to season, varying cold water temperatures can result in different maximum mixed water and outlet volumes.
Note
A qualified contractor can set a temperature limit on the appliance (see "Installation/ Settings/ Setting the tem­perature limit").
Note
The appliance is under mains water pressure. The water volume increases as the cylinder is being heated up. Dur­ing this process, expansion water drips through the safety valve. This is a necessary and normal process.
3.1 Settings
You can set any required DHW outlet temperature at the tem­perature selector. The heat-up indicator illuminates during the heat-up process.
1
Material losses
!
If the drain pipe of the safety valve is sealed, expanding water can lead to water damage.
Never close the drain pipe.
2.3 Test symbols
See type plate on the appliance.
2
D0000039370
1 Temperature selector 2 Heat-up indicator
Depending on the system, the actual temperatures may vary from the set value.
* = Cold. On this setting, the appliance is protected from
frost. The tap, water lines and safety valve are not pro­tected.
MAX = Highest selectable temperature
4 | SHC 10 | SHC 15 www.stiebel-eltron.com
OPERATION
Cleaning, care and maintenance
4. Cleaning, care and maintenance
Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
Check the taps regularly. Limescale deposits at the tap out-
lets can be removed using commercially available descaling agents.
Regularly activate the safety valve to prevent it from becom-
ing blocked, e.g. by limescale deposits.
Have the protective anode checked by a qualified contractor
after the first 2years of operation. The qualified contractor will then determine the intervals at which it must be checked thereafter.
Almost every type of water will deposit limescale at high temper­atures. This settles inside the appliance and affects both the per­formance and service life. The heating element should therefore be descaled if necessary. A qualified contractor who is aware of the local water quality will tell you when the next descaling is due.
5. Troubleshooting
Problem Cause Remedy
The appliance does not supply hot water.
No power at the
Water can only be drawn at a reduced rate.
Loud boiling noises in­side the appliance.
Water drips from the safety valve after heat-up.
If you cannot remedy the fault, notify your qualified contractor. To facilitate and speed up your enquiry, please provide the serial number from the type plate. (000000):
The temperature selector is set to "*".
appliance. The aerator in
the tap is scaled up or dirty.
The appliance is scaled up.
The safety valve is scaled up or dirty.
Switch the appliance ON by turning the temperature selector.
Check the plug/ fuses in the fuse box.
Descale / replace the aerator.
Have the appliance descaled by a qualified contractor.
Switch the appliance off. Depressur­ise the appliance by disconnecting it from the power and water supply. Have the safety valve checked by a qualified contractor.
INSTALLATION
6. Safety
Only a qualified contractor should carry out installation, commis­sioning, maintenance and repair of the appliance.
6.1 General safety instructions
We guarantee trouble-free function and operational reliability only if original accessories and spare parts intended for the appliance are used.
6.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations and instructions.
7. Appliance description
The sealed unvented (pressurised) appliance is only suitable for undersink installation. The appliance is intended for heating cold water and to supply one or several draw-off points.
The appliance may only be installed with pressure taps in con­junction with a type-tested safety valve (see chapter “Installation/ Appliance description/ Standard delivery”).
The type-tested safety valve protects the appliance against unac­ceptable excess pressure.
The enamelled internal steel cylinder is equipped with a protective anode. The protective anode protects the inner cylinder against corrosion.
7.1 Standard delivery
The following are delivered with the appliance:
- Wall mounting bracket
ENGLISH
O-No.
F-No.
000000
0000 - 000000
SHC10 | SHC15Stiebel
- Two reducers from G1/2 to G3/8
D0000039382
SHC 10 GB Eltron | SHC 15 GB Eltron
- Two locking ring fittings G1/2x15
7.2 Accessories
SHC10 | SHC15Stiebel
- Safety assembly G1/2 (optional)
www.stiebel-eltron.com SHC 10 | SHC 15 | 5