15.4 Country-specific approvals and certifications ������������� 11
15.5 Extreme operating and fault conditions ������������������� 11
15.6 Details on energy consumption ������������������������������ 12
15.7 Data table �������������������������������������������������������� 12
GUARANTEE
ENVIRONMENT AND RECYCLING
SPECIAL INFORMATION
- The appliance may be used by children aged8
and older and persons with reduced physical,
sensory or mental capabilities or a lack of experience and know-how, provided that they are
supervised or they have been instructed on how
to use the appliance safely and have understood
the resulting risks. Children must never play with
the appliance. Children must never clean the appliance or perform user maintenance unless they
are supervised.
- When permanently connected to the power supply using a dedicated junction box, the appliance
must be able to be isolated from the mains power
supply by an isolator that disconnects all poles
with at least 3mm contact separation.
- The power cable may only be replaced (for example if damaged) by a qualified contractor authorised by the manufacturer, using an original spare
part.
- Secure the appliance as described in chapter "Installation/ Installation".
- Observe the maximum permissible pressure (see
chapter "Installation/ Specification/ Data table").
- Drain the appliance as described in chapter "Installation/ Maintenance/ Draining the appliance".
- The appliance is pressurised. During the heat-up
process, expansion water will drip from the safety
valve.
- Regularly activate the safety valve to prevent
it from becoming blocked, e.g. by limescale
deposits.
2 | SHC 10 | SHC 15 www.stiebel-eltron.com
OPERATION
General information
- Install a type-tested safety valve in the cold water
supply line. Depending on the supply pressure,
you may also need a pressure reducing valve.
- Size the drain pipe so that water can drain off unimpeded when the safety valve is fully opened.
- Fit the drain pipe of the safety valve with a constant downward slope and in a room free from
the risk of frost.
- The safety valve drain must remain open to the
atmosphere.
OPERATION
1. General information
The chapters "Special Information" and "Operation" are intended
for both the user and qualified contractors.
The chapter "Installation" is intended for qualified contractors.
Note
Read these instructions carefully before using the appliance and retain them for future reference.
Pass on the instructions to a new user if required.
1.1.3 Keywords
KEYWORDMeaning
DANGER Failure to observe this information will result in serious
WARNING Failure to observe this information may result in serious
CAUTION Failure to observe this information may result in non-seri-
injury or death.
injury or death.
ous or minor injury.
1.2 Other symbols in this documentation
Note
General information is identified by the adjacent symbol.
Read these texts carefully.
SymbolMeaning
!
This symbol indicates that you have to do something. The ac-
tion you need to take is described step by step.
Material losses
(appliance damage, consequential losses and environmental pollution)
Appliance disposal
1.3 Units of measurement
Note
All measurements are given in mm unless stated otherwise.
ENGLISH
1.1 Safety instructions
1.1.1 Structure of safety instructions
KEYWORD Type of risk
!
Here, possible consequences are listed that may result
from failure to observe the safety instructions.
Steps to prevent the risk are listed.
1.1.2 Symbols, type of risk
SymbolType of risk
!
Injury
Electrocution
Burns
(burns, scalding)
2. Safety
2.1 Intended use
This sealed unvented (pressurised) appliance is intended for heating domestic hot water. The appliance can supply one or more
draw-off points.
This appliance is intended for domestic use. It can be used safely
by untrained persons. The appliance can also be used in a non-domestic environment, e.g. in a small business, as long as it is used
in the same way.
Any other use beyond that described shall be deemed inappropriate. Observation of these instructions and of instructions for any
accessories used is also part of the correct use of this appliance.
www.stiebel-eltron.com SHC 10 | SHC 15 | 3
OPERATION
Appliance description
2.2 General safety instructions
WARNING Burns
During operation, the tap and safety valve can reach
temperatures in excess of 60°C.
There is a risk of scalding at outlet temperatures in excess of 43°C.
WARNING Injury
!
The temperature selector should only be removed by a
qualified contractor.
WARNING Injury
!
The appliance may be used by children aged 8 and older
and persons with reduced physical, sensory or mental
capabilities or a lack of experience and know-how, provided that they are supervised or they have been instructed on how to use the appliance safely and have
understood the resulting risks. Children must never play
with the appliance. Children must never clean the appliance or perform user maintenance unless they are
supervised.
Where children or persons with limited physical, sensory or mental abilities are allowed to use this appliance, we recommend a
permanent temperature limit. A qualified contractor can set this
limit.
Material losses
!
The user should protect the appliance, the water pipes,
the safety valve and the tap against frost.
3. Appliance description
The appliance constantly keeps the water content available at the
preselected temperature. The appliance switches on automatically
as soon as its temperature falls below the set value.
Subject to season, varying cold water temperatures can result in
different maximum mixed water and outlet volumes.
Note
A qualified contractor can set a temperature limit on the
appliance (see "Installation/ Settings/ Setting the temperature limit").
Note
The appliance is under mains water pressure. The water
volume increases as the cylinder is being heated up. During this process, expansion water drips through the safety
valve. This is a necessary and normal process.
3.1 Settings
You can set any required DHW outlet temperature at the temperature selector. The heat-up indicator illuminates during the
heat-up process.
1
Material losses
!
If the drain pipe of the safety valve is sealed, expanding
water can lead to water damage.
Never close the drain pipe.
2.3 Test symbols
See type plate on the appliance.
2
D0000039370
1 Temperature selector
2 Heat-up indicator
Depending on the system, the actual temperatures may vary from
the set value.
* = Cold. On this setting, the appliance is protected from
frost. The tap, water lines and safety valve are not protected.
MAX = Highest selectable temperature
4 | SHC 10 | SHC 15 www.stiebel-eltron.com
OPERATION
Cleaning, care and maintenance
4. Cleaning, care and maintenance
Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
Check the taps regularly. Limescale deposits at the tap out-
lets can be removed using commercially available descaling
agents.
Regularly activate the safety valve to prevent it from becom-
ing blocked, e.g. by limescale deposits.
Have the protective anode checked by a qualified contractor
after the first 2years of operation. The qualified contractor
will then determine the intervals at which it must be checked
thereafter.
Almost every type of water will deposit limescale at high temperatures. This settles inside the appliance and affects both the performance and service life. The heating element should therefore
be descaled if necessary. A qualified contractor who is aware of
the local water quality will tell you when the next descaling is due.
5. Troubleshooting
ProblemCauseRemedy
The appliance does not
supply hot water.
No power at the
Water can only be
drawn at a reduced
rate.
Loud boiling noises inside the appliance.
Water drips from the
safety valve after
heat-up.
If you cannot remedy the fault, notify your qualified contractor.
To facilitate and speed up your enquiry, please provide the serial
number from the type plate. (000000):
The temperature
selector is set
to "*".
appliance.
The aerator in
the tap is scaled
up or dirty.
The appliance is
scaled up.
The safety valve
is scaled up or
dirty.
Switch the appliance ON by turning
the temperature selector.
Check the plug/ fuses in the fuse
box.
Descale / replace the aerator.
Have the appliance descaled by a
qualified contractor.
Switch the appliance off. Depressurise the appliance by disconnecting
it from the power and water supply.
Have the safety valve checked by a
qualified contractor.
INSTALLATION
6. Safety
Only a qualified contractor should carry out installation, commissioning, maintenance and repair of the appliance.
6.1 General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
6.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
7. Appliance description
The sealed unvented (pressurised) appliance is only suitable for
undersink installation. The appliance is intended for heating cold
water and to supply one or several draw-off points.
The appliance may only be installed with pressure taps in conjunction with a type-tested safety valve (see chapter “Installation/
Appliance description/ Standard delivery”).
The type-tested safety valve protects the appliance against unacceptable excess pressure.
The enamelled internal steel cylinder is equipped with a protective
anode. The protective anode protects the inner cylinder against
corrosion.
7.1 Standard delivery
The following are delivered with the appliance:
- Wall mounting bracket
ENGLISH
O-No.
F-No.
000000
0000 - 000000
SHC10 | SHC15Stiebel
- Two reducers from G1/2 to G3/8
D0000039382
SHC 10 GB Eltron | SHC 15 GB Eltron
- Two locking ring fittings G1/2x15
7.2 Accessories
SHC10 | SHC15Stiebel
- Safety assembly G1/2 (optional)
www.stiebel-eltron.com SHC 10 | SHC 15 | 5