BEDIENUNG UND INSTALLATION
OPERATION AND INSTALLATION
UTILISATION ET INSTALLATION
BEDIENING EN INSTALLATIE
USO E INSTALLAZIONE
OBSLUHA A INSTALACE
OBSŁUGA I INSTALACJA
KÄYTTÖ JA ASENNUS
Durchlaufspeicher | Instantaneous water heating cylinder | Ballon à écoulement
libre| Doorstroomboilers | Scaldacqua con bollitore | Průtokový zásobník |
Zasobnik przepływowy | Läpivirtausvaraajat
» SBS 601 W
» SBS 801 W
» SBS 1001 W
» SBS 1501 W
» SBS 601 W SOL
» SBS 801 W SOL
» SBS 1001 W SOL
» SBS 1501 W SOL

Contents | Operation
General information
OPERATION
1. General information ��������������������������������������� 14
1.1 Document information ����������������������������������������� 14
1.2 Safety instructions ����������������������������������������������14
1.3 Other symbols in this documentation ���������������������� 14
1.4 Units of measurement ����������������������������������������� 15
2. Safety �������������������������������������������������������� 15
2.1 Intended use ����������������������������������������������������� 15
2.2 Safety information ���������������������������������������������� 15
2.3 Test symbols �����������������������������������������������������15
3. Appliance description ������������������������������������� 15
4. Cleaning, care and maintenance ������������������������� 15
4.1 Scaling ������������������������������������������������������������ 15
5. Troubleshooting �������������������������������������������� 15
INSTALLATION
6. Safety �������������������������������������������������������� 16
6.1 General safety instructions ����������������������������������� 16
6.2 Instructions, standards and regulations ������������������� 16
6.3 Water installation ����������������������������������������������� 16
7. Appliance description ������������������������������������� 16
7.1 Standard delivery ����������������������������������������������� 16
7.2 Accessories �������������������������������������������������������16
8. Assembly ���������������������������������������������������� 16
8.1 Installation location �������������������������������������������� 16
8.2 Transport ��������������������������������������������������������� 16
8.3 Assembly ��������������������������������������������������������� 17
9. Commissioning ��������������������������������������������� 17
10. Taking the appliance out of use �������������������������� 17
11. Recommissioning ������������������������������������������ 17
12. Appliance handover ���������������������������������������� 18
13. Troubleshooting �������������������������������������������� 18
13.1 Fault table �������������������������������������������������������� 18
14. Maintenance ������������������������������������������������ 18
14.1 Checking the safety valve �������������������������������������18
14.2 Draining the appliance ����������������������������������������18
15. Specification ������������������������������������������������ 19
15.1 Dimensions and connections ��������������������������������� 19
15.2 Data table �������������������������������������������������������� 23
GUARANTEE
ENVIRONMENT AND RECYCLING
OPERATION
1. General information
1.1 Document information
The chapter “Operation” is intended for the equipment user and
the heating contractor.
The chapter “Installation” is intended for the heating contractor.
Note
Read these instructions carefully before using the appliance and retain them for future reference.
Pass on the instructions, if required, to a new user.
1.2 Safety instructions
1.2.1 Structure of safety instructions
KEYWORD Type of risk
!
Here, possible consequences are listed that may result
from failure to observe the safety instructions.
Steps to prevent the risk are listed.
1.2.2 Symbols, type of risk
Symbol Type of risk
!
1.2.3 Keywords
KEYWORD Meaning
DANGER Failure to observe this information will result in serious
WARNING Failure to observe this information may result in serious
CAUTION Failure to observe this information may result in non-
Injury
Electrocution
Burns
(burns, scalding)
injury or death.
injury or death.
serious or minor injury.
1.3 Other symbols in this documentation
Note
General information is identified by the symbol shown
on the left.
Read these texts carefully.
14 | SBS 601-1501 W SOL www.stiebel-eltron.COM

Operation
Safety
Symbol Meaning
!
This symbol indicates that you have to do something. The ac-
tion you need to take is described step by step.
Material damage
(Appliance and consequential losses, environmental pollution)
Appliance disposal
1.4 Units of measurement
Note
All measurements are given in mm unless stated otherwise.
2. Safety
2.1 Intended use
This appliance is designed for the storage of heating water and for
DHW heating. A glycol/water mixture of up to 60% is permitted
if only dezincification-resistant metals, glycol-resistant gaskets
and diaphragm expansion vessels suitable for glycol are used
throughout the installation.
Any other or additional use is inappropriate, in particular usage
with alternative storage media. Observation of these instructions
and of instructions for any accessories used is also part of the
correct use of this appliance..
2.2 Safety information
WARNING Burns
There is a risk of scalding at outlet temperatures in excess of 43 °C.
3. Appliance description
DThe appliance combines DHW heating and a buffer cylinder for
the hydraulic separation of heating system and heat pump. The
DHW is heated via a corrugated stainless steel internal indirect
coil that functions like an instantaneous water heater. The volume
of the cylinder is an energy store for DHW heating.
The appliance is ideally suited to operation with a heat pump.
In addition, a threaded immersion heater and an auxiliary heat
source can be connected.
SBS W SOL
These appliance types are also equipped with an internal indirect
coil for solar DHW heating and central heating backup.
4. Cleaning, care and maintenance
Have the function of the safety assembly and electrical safety
of the fitted special accessories regularly checked by a heating contractor/electrician.
Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
4.1 Scaling
Almost every type of water deposits limescale at high tem-
peratures. This settles inside the appliance and affects both
the performance and service life. If a flanged immersion
heater is installed, the heating elements must be descaled
from time to time. A heating contractor who knows the local
water quality will tell you when the next service is due.
Check the taps regularly. You can remove limescale deposits
at the tap outlets using commercially available descaling
agents.
Regularly activate the safety valve to prevent it from becom-
ing blocked e.g. by limescale deposits.
ENGLISH
WARNING Injury
!
The appliance may be used by children aged 8 and up and
persons with reduced physical, sensory or mental capabilities or a lack of experience and know-how provided
that they are supervised or they have been instructed
on how to use the appliance safely and have understood
the resulting risks. Children must never play with the
appliance. Children must never clean the appliance or
perform user maintenance unless they are supervised.
Material damage
!
The appliance is under pressure.
During the heating process, expansion water will drip
from the safety valve. If water continues to drip when
heating is completed, please inform your heating contractor.
2.3 Test symbols
See type plate on the appliance.
5. Troubleshooting
Fault Cause Remedy
The outlet flow rate
is low.
If you cannot remedy the fault, notify your heating contractor. To
facilitate and speed up your enquiry, please provide the serial
number from the type plate (no. 000000-0000-000000):
The perlator in the tap or
shower head is scaled up
or contaminated.
Nr. 000000-0000-000000
Clean and/or descale the
perlator or the shower head.
26�03�20�0017
WWW.stiebel-eltron.COM SBS 601-1501 W SOL | 15

Installation
Safety
INSTALLATION
6. Safety
Only qualified contractors should carry out installation, commissioning, maintenance and repair of the appliance.
6.1 General safety instructions
We can only guarantee trouble-free function and operational reliability if original spare parts intended for the appliance are used.
6.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
6.3 Water installation
6.3.1 Cold water line
Steel or copper pipes or plastic pipework are approved materials.
Material damage
!
A safety valve is required.
7. Appliance description
7.1 Standard delivery
Delivered with the appliance:
- 2x temperature sensors
- 2x heat conducting paste
- additional type plate
7.2 Accessories
Depending on the static pressure, safety assemblies and pressure
reducing valves are available. These type-tested safety assemblies
protect the appliance against unacceptable excess pressure.
Flanged immersion heaters, circulation set and thermal insulation
are available as accessories.
8. Assembly
8.1 Installation location
Ensure the floor has a sufficient load bearing capacity (see
chapter “Specification/ Data table”).
Ensure the floor is level.
Check the height of the room and of the unit when tilted (see
chapter “Specification/ Data table”).
Minimum clearances
6.3.2 DHW line
Copper, stainless steel or plastic pipework are approved materials.
Material damage
!
Beim gleichzeitigen Einsatz von Kunststoff-Rohrsystemen
If a flanged immersion heater is fitted and plastic pipework systems are used at the same time, observe the
maximum permissible temperature/ the maximum permissible pressure in chapter “Specification/ Data table”.
Material damage
!
Operate the appliance only with pressure-tested taps and
valves.
≥200≥200
≥200 ≥210
≥800
Maintain the minimum clearances.
8.2 Transport
The lifting eye can be fitted to the top of the appliance to assist
handling.
D0000057346
16 | SBS 601-1501 W SOL www.stiebel-eltron.COM