STIEBEL ELTRON SBP 100, WPKI-H E, SBP-HF, WPKI-P E, WPKI-W E, WPKI-V Operation And Installation
Specifications and Main Features
Frequently Asked Questions
User Manual
BEDIENUNG UND INSTALLATION
OPERATION AND INSTALLATION
UTILISATION ET INSTALLATION
OBSLUHA A INSTALACE
OBSŁUGA I INSTALACJA
Pufferspeicher mit Heizansch und Wärmepumpen-Kompaktinstallationen|
Buffer cylinder with anged immersion heater and compact heat pump installations|
Ballon tampon avec résistance électrique à bride et kit hydraulique pompe à chaleur|
Akumulační zásobník s topnou přírubou a kompaktními instalacemi tepelného čerpadla|
Zbiornik buforowy z kołnierzem grzejnym oraz instalacjami kompaktowymi dla pomp ciepła
» SBP 100
» SBP-HF
» WPKI-H E
» WPKI-P E
60
» WPKI-W E
» WPKI-V
60
80
40
°C
20
100
0
120
60
80
80
40
40
°C
°C
20
20
100
100
0
0
120
120
2
1
3
4
0
bar
65°C
CONTENTS | SPECIAL INFORMATION
SPECIAL INFORMATION
OPERATION
1. General information ��������������������������������������� 23
15.5 Details on energy consumption ������������������������������ 39
15.6 Data tables ������������������������������������������������������� 39
SPECIAL INFORMATION
- The appliance may be used by children aged8
and older and persons with reduced physical,
sensory or mental capabilities or a lack of experience and know-how, provided that they are
supervised or they have been instructed on how
to use the appliance safely and have understood
the resulting risks. Children must never play with
the appliance. Children must never clean the appliance or perform user maintenance unless they
are supervised.
- Immersion heater accessory: The connection to
the power supply must be in the form of a permanent connection. The appliance must be able
to be separated from the power supply by an isolator that disconnects all poles with at least 3mm
contact separation.
- Secure the appliance as described in chapter "Installation/ Preparations".
- Observe the maximum permissible pressure (see
chapter "Installation/ Specification/ Data table").
- Regularly activate the safety valve to prevent it
from becoming blocked.
- Drain the appliance as described in chapter "Installation/ Maintenance/ Draining the appliance".
- Install a type-tested safety valve.
- Fit the discharge pipe of the safety valve with
a constant downward slope and in a room free
from the risk of frost.
- The safety valve discharge aperture must remain
open to the atmosphere.
GUARANTEE
ENVIRONMENT AND RECYCLING
22 | SBP 100 www.stiebel-eltron.com
OPERATION
General information
OPERATION
1. General information
The chapters "Special Information" and "Operation" are intended
for both the user and qualified contractors.
The chapter "Installation" is intended for qualified contractors.
Note
Read these instructions carefully before using the appliance and retain them for future reference.
Pass on the instructions to a new user if required.
1.1 Safety instructions
1.1.1 Structure of safety instructions
KEYWORD Type of risk
!
Here, possible consequences are listed that may result
from failure to observe the safety instructions.
Steps to prevent the risk are listed.
1.2 Other symbols in this documentation
Note
General information is identified by the adjacent symbol.
Read these texts carefully.
SymbolMeaning
!
This symbol indicates that you have to do something. The ac-
tion you need to take is described step by step.
Material losses
(appliance damage, consequential losses and environmental pollution)
Appliance disposal
1.3 Units of measurement
Note
All measurements are given in mm unless stated otherwise.
2. Safety
ENGLISH
1.1.2 Symbols, type of risk
SymbolType of risk
!
1.1.3 Keywords
KEYWORDMeaning
DANGER Failure to observe this information will result in serious
WARNING Failure to observe this information may result in serious
CAUTION Failure to observe this information may result in non-seri-
Injury
Electrocution
Burns
(burns, scalding)
injury or death.
injury or death.
ous or minor injury.
2.1 Intended use
The appliance acts primarily as a buffer cylinder for heat pumps
to function as a hydraulic separator of the flow between the heat
pump circuit and the heating circuit.
This appliance is intended for domestic use. It can be used safely
by untrained persons. The appliance can also be used in a non-domestic environment, e.g. in a small business, as long as it is used
in the same way.
Observation of these instructions and of instructions for any accessories and other system components is also part of the correct
use of this appliance.
Any other use beyond that described shall be deemed inappropriate. Using the appliance for heating fluids other than water
or for water supplemented with chemicals, such as brine, is also
deemed inappropriate.
www.stiebel-eltron.com SBP 100| 23
OPERATION
65°C
Appliance description
2.2 General safety instructions
WARNING Burns
There is a risk of scalding at outlet temperatures in excess of 43 °C.
WARNING Injury
!
The appliance may be used by children aged 8 and older
and persons with reduced physical, sensory or mental
capabilities or a lack of experience and know-how, provided that they are supervised or they have been instructed on how to use the appliance safely and have
understood the resulting risks. Children must never play
with the appliance. Children must never clean the appliance or perform user maintenance unless they are
supervised.
With immersion heater accessory:
Material losses
!
The user must protect the water pipes and safety valve
from frost.
2.3 Test symbols
See type plate on the appliance.
3. Appliance description
This pressurised appliance is equipped with a quick-action air vent
valve and a cleaning aperture with drain & fill valve.
An immersion heater can be retrofitted.
4. Immersion heater accessory:
Settings
The temperature is variably adjustable.
1
2
1 ON/OFF indicator
2 Frost protection
65°C maximum temperature setting
Depending on the system, the actual temperatures may vary from
the set value.
ON/OFF indicator
The ON/OFF indicator illuminates when water is being heated.
5. Cleaning, care and maintenance
Have the function of the safety assembly and electrical safe-
ty of the fitted accessories regularly checked by a qualified
contractor.
Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
Regularly activate the safety valve to prevent it from becom-
ing blocked.
26�03�01�0343
Frost protection with immersion heater accessory
If the power supply is guaranteed, the appliance is also protected
from frost on the temperature setting "cold". The appliance switches on in good time and heats the water. The appliance does not
protect the water pipes and safety valve from frost.
6. Troubleshooting
Call your qualified contractor.
To facilitate and speed up your enquiry, please provide the serial
number from the type plate (000000-0000-000000):
000000-0000-000000
Made in Germany
D0000048097
24 | SBP 100 www.stiebel-eltron.com
INSTALLATION
756
Safety
INSTALLATION
7. Safety
Only a qualified contractor should carry out installation, commissioning, maintenance and repair of the appliance.
7.1 General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
7.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
8. Appliance description
8.1 Standard delivery
The following are delivered with the appliance:
- 2 wall mounting brackets
- Mounting panel
- Quick-action air vent valve G 1/2
- Connector with sensor well for return temperature sensor
9. Preparations
9.1 Installation site
The appliance is designed for installation on a solid wall. Ensure
the wall offers adequate load bearing capacity.
Always install the appliance vertically in a room free from the risk
of frost. The room must be at least 2200mm high.
9.2 Fitting the wall mounting bracket/ mounting
panel
The appliance can be mounted on the wall mounting bracket or,
with clearance to the wall, to the mounting panel.
Observe the minimum clearances to the heat pump.
1
880
282
52
350
≥2200
≥100
280
2
ENGLISH
8.2 Accessories
8.2.1 Required accessories
Various safety assemblies are available for sealed unvented (pressurised) operation, depending on the supply pressure. These
type-tested safety assemblies protect the appliance against unacceptable excess pressure.
8.2.2 Further accessories
Booster heater
The flanged immersion heater is intended for retrofitting.
Compact heat pump installations
Compact heat pump installations are heat pump system components that have been especially designed for the SBP100 cylinder.
Circulation pumps are available as required accessories for compact heat pump installations which are approved for direct connection to the heat pump manager:
- UP 25/7.0 E, part number 232942
- UP 25/7.5 E, part number 232943
45°
510
510
1 Mounting panel
2 Heat pump
Mark out the holes to be drilled on the wall (see chapter
"Specification/ Dimensions and connections").
562
D0000048224
www.stiebel-eltron.com SBP 100| 25
INSTALLATION
Installation
1
1 Mounting panel
Drill the holes and secure the wall mounting bracket or
mounting panel with screws and rawl plugs. Select fixing
materials in accordance with the wall construction/condition.
9.3 Connector with sensor sleeve
Screw the connector with sensor sleeve for the return
temperature sensor into the "charging station return opt."
connection (see chapter "Specification/ Dimensions and
connections").
10.1.2 Fitting the immersion heater
Note
If you would like to retrofit the immersion heater, please
observe the following:
Drain the cylinder (see chapter "Maintenance/
Draining the appliance")
Release the pipe fittings and remove the appliance
from the wall.
D0000048229
Remove the lower cover.
26�03�01�0342
1
9.4 Fitting the quick-action air vent valve
Fit the quick-action air vent valve provided to the "ventilation"
connection (see chapter "Specification/ Dimensions and connections").
10. Installation
10.1 Immersion heater accessory
10.1.1 Standard delivery
- Type plate
- Adhesive fascia
- Fitting PG 11
- Wiring diagram label
- Seal ring
- Safety valve
2
34
26�03�01�0341
1 Quick-action air vent valve
2 Booster heater
3 Seal ring
4 Drain valve
Remove the drain valve.
Remove the flange plate. To do this, undo the 10 screws.
Fit the immersion heater with the seal ring supplied.
Connect the insulating plate.
26 | SBP 100 www.stiebel-eltron.com