STIEBEL ELTRON MINI6-2 User Manual [en, es, fr]

OPERATION AND INSTALLATION OPERACIÓN E INSTALACIÓN UTILISATION ET INSTALLATION
TANKLESS ELECTRIC WATER HEATER WITH ELECTRO-MECHANICAL FLOW SWITCH CALENTADOR ELÉCTRICO DE AGUA SIN TANQUE CON SENSOR ELECTROMECÁNICO DE FLUJO CHAUFFE-EAU ELECTRIQUE SANS RESERVOIR AVEC CONTACTEUR DEBITMETRIQUE ELECTRO-MECANIQUE
» MINI™ 2-1 » MINI™ 2.5-1 » MINI™ 3-1 » MINI™ 3.5-1 » MINI™ 4-2 » MINI™ 6-2
The Mini™ series is tested and certifi ed by WQA against NSF/ ANSI 372 for lead free compliance.
STIEBEL ELTRON, Inc.
17 West Street | West Hatfi eld, MA 01088 Tel. 413-247-3380 | Fax 413-247-3369 Email info@stiebel-eltron-usa.com www.stiebel-eltron-usa.com
CONTENTS | OPERATION
po
p
p
p
popopopop
p
p
ppwer
GENERAL INFORMATION
1. General Information ____________________________________ 2
1.1 Symbol key ______________________________________________ 2
2. Safety precautions ______________________________________ 3
3. Register your product __________________________________ 3
4. Temperature increase above ambient water temperature _____________________________________________ 4
5. Technical drawings _____________________________________ 4
6. Overview ________________________________________________ 6
6.1 Figure legend ___________________________________________ 6
6.2 General description _____________________________________ 6
6.3 Important information before supplying power to unit _______________________________________________________ 6
6.4 Hot water output ________________________________________ 7
6.5 Incorrect use ____________________________________________ 7
6.6 First steps to be taken in the event of malfunction ___ 7
6.7 Maintenance and care __________________________________ 7
7. Operating and installation instructions _______________ 7
7.1 Mounting the unit _______________________________________ 7
7.2 Plumbing connections __________________________________ 7
7.3 Electrical connection ____________________________________ 8
8. Initial start-up __________________________________________ 8
9. Water heater hand over ________________________________ 8
10. Normal maintenance ___________________________________ 8
11. Technical data ___________________________________________ 9
12. Troubleshooting _________________________________________ 9
13. Spare parts _____________________________________________10
14. Warranty _______________________________________________10
THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT
!
YOU TO POTENTIAL PERSONAL INJURY HAZARD. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO AVOID POSSIBLE INJURY OR DEATH.
The chapter Operation is intended for homeowners, heating contractors, plumbers and electricians.
The chapter Installation is intended for heating contractors, plumbers and electricians only.
1.1 Symbol key
1.1.1 Layout of safety information
1
2
DANGER Electric shock
Before any work on the appliance, disconnect all poles from the power supply.
3
4
1 Symbol (see 1.1.2 "Symbols") 2 Keyword (see 1.1.3 "Keywords") 3 Designations (see 1.1.2 "Symbols")
4 Information text
1.1.2 Symbols
Symbol Description
Injury
1. General Information
Read this entire manual. Failure to follow all the guides, instructions and rules could cause personal injury or property damage. Improper installation, adjustment, alteration, service and use of this unit can result in serious injury.
T hi s u ni t m u st be i ns t al le d by a li ce ns e d e l ec t r ic i an an d p l um b er . T h e installation must comply with all national, state and local plumbing and electric codes. Proper installation is the responsibility of the installer. Failure to comply with the installation and operating instructions or improper use voids the warranty.
Save these instructions for future reference. Installer should leave these instructions with the consumer.
If you have any questions regarding the installation, use or operation of this water heater, or if you need any additional installation manuals, please call our technical service line at 800­582-8423 (USA and Canada only). If you are calling from outside the USA or Canada, please call USA 413-247-3380 and we will refer you to a qualifi ed Stiebel Eltron service representative in your area.
2 | MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
!
1.1.3 Keywords
KEYWORD
DANGER The keyword DANGER indicates information that
WARNING The keyword WARNING indicates information that
CAUTION The keyword CAUTION indicates information that
Electrocution
Burns or scalding
Other situations
must be observed, otherwise serious injury or death will result.
must be observed, otherwise serious injury or death may result.
must be observed, otherwise relatively serious or light injuries may result.
GENERAL INFORMATION
SAFETY PRECAUTIONS
2. Safety precautions
PLEASE READ AND FOLLOW THESE INSTRUCTIONS.
!
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD
RESULT IN SERIOUS BODILY INJURY OR DEATH.
THE UNIT MUST BE INSTALLED BY A LICENSED ELECTRICIAN AND PLUMBER. THE INSTALLATION MUST COMPLY WITH ALL NATIONAL, STATE AND LOCAL PLUMBING AND ELECTRIC CODES.
SERVICE OF THE UNIT MUST BE PERFORMED BY QUALIFIED SERVICE TECHNICIANS.
BEFORE PROCEEDING WITH ANY INSTALLATION,
ADJUSTMENT, ALTERATION, OR SERVICE OF THIS UNIT ALL CIRCUIT BREAKERS AND DISCONNECT SWITCHES SERVICING THE UNIT MUST BE TURNED OFF. FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURY OR DEATH.
DANGER: NEVER REMOVE THE UNIT'S COVER UNLESS
THE ELECTRICITY SERVICING THE UNIT IS TURNED OFF. FAILURE TO DO SO COULD RESULT IN PERSONAL INJURY OR DEATH.
WARNING: THE UNIT MUST BE PROPERLY GROUNDED.
FAILURE TO ELECTRICALLY GROUND THE PRODUCT COULD RESULT IN SERIOUS PERSONAL INJURY OR DEATH.
DANGER: WATER TEMPERATURES OVER 125°F CAN
CAUSE SEVERE BURNS INSTANTLY OR DEATH FROM SCALDING. A HOT WATER SCALDING POTENTIAL EXISTS IF THE THERMOSTAT ON THE UNIT IS SET TOO HIGH. HOUSEHOLDS WITH SMALL CHILDREN, DISABLED OR ELDERLY PERSONS MAY REQUIRE THAT THE THERMOSTAT BE SET AT 120°F OR LOWER TO PREVENT POSSIBLE INJURY FROM HOT WATER.
3. Register your product
YOU MUST REGISTER THIS PRODUCT WITHIN 90 DAYS OF
PURCHASE ON OUR WEB SITE IN ORDER TO ACTIVATE THE
STANDARD WARRANTY OR TO BE ELIGIBLE FOR THE EXTENDED WARRANTY. GO TO OUR WEB SITE AT WWW.STIEBEL-ELTRON-USA. COM AND CLICK ON REGISTER YOUR PRODUCT.
Before beginning the registration process, we suggest that you gather the necessary information which will be as follows:
Type, Example: Mini 3-1 (from the white label that is on the right side of the unit)
Number listed after "Nr." Place of Purchase Purchase Date First & Last Name Email address Physical Address Phone Number
IF YOU HAVE ANY QUESTIONS CONCERNING THE REGISTRATION PROCESS OR WARRANTY OPTIONS, PLEASE CONTACT STIEBEL ELTRON USA DIRECTLY AT (800)-582-8423.
Limited liability warranty:
Stiebel Eltron, Inc. is not liable for damages to the unit, damage to personal property, bodily injury, or loss of life due to the following conditions:
- Non-observance of these instructions
- Incorrect use (heating any other liquid than water)
- Installation of the appliance by unqualifi ed personnel
- Unauthorized modifi cations
- Technical modifi cations
- Use of unauthorized spare parts
ENGLISH
THE THREE YEAR WARRANTY COVERS ALL PARTS BUT DOES NOT COVER DAMAGE TO THE UNIT DUE TO HARD WATER (FOR THE COMPLETE WARRANTY SEE "WARRANTY", SECTION 14 PG. 10). IF YOU KNOW OR SUSPECT THAT THE WATER IN YOUR AREA IS HARD (HAS A HIGH MINERAL CONTENT), IT IS NECESSARY TO INSTALL A WATER SOFTENING DEVICE TO AVOID DAMAGE TO THE MINI UNIT.
WWW.STIEBEL-ELTRON-USA.COM MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS | 3
GENERAL INFORMATION
TEMPERATURE INCREASE ABOVE AMBIENT WATER TEMPERATURE
4. Temperature increase above ambient water temperature
[ °F ]
Type kW GPM
0.32 0.42 0.48 0.5 0.69 0.85 1.06 1.14
Mini 2-1* 1.8 38 – – – – – – –
Mini 2.5-1
Mini 3-1
Mini 3.5-1
Mini 4-2
Mini 6-2
Type kW l/min
1.2 1.6 1.8 2.0 2.6 3.2 4.0 4.3
Mini 2-1* 1.8 22 – – – – – – – Mini 2.5-1 Mini 3-1 Mini 3.5-1
Mini 4-2 Mini 6-2
2.4 – 39 34 33 24 – – –
3.0 – 49 43 41 30 – – –
3.5 – 57 50 45 35 – – –
3.5 – 57 50 45 35 – – –
5.7 – – – – – 46 37 34
Min. water fl ow to activate unit.
[ °C ]
2.4 – 22 19 17 13 – – –
3.0 – 27 24 22 17 – – –
3.5 – 31 28 25 19 – – –
3.5 – 31 28 25 19 – – –
5.7 – – – – – 26 20 19
Min. water fl ow to activate unit.
* Note: Mini 2-1 is internally restricted to 0.32 gpm (1.2 l/min)
* Note: Mini 2-1 is internally restricted to 0.32 gpm (1.2 l/min)
5. Technical drawings
A
” (143 mm)
8
5
5/
1
¾
” (120 mm)
4
7 ½ ” (190 mm) 3 ¼ ” (82 mm)
4
” (4,8 mm)
16
/
3
(165 mm)
6½”
3/8” O.D. flex connector
13
/16 ” (20 mm)
3
1/
” (30 mm)
16
mm)
3¾” (95
2
3
C26_02_05_0009
4 | MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
GENERAL INFORMATION
TECHNICAL DRAWINGS
CB
D
9
5
10
8
ENGLISH
7
6
C26_02_05_0010
V >
p >
2-1/2.5-1
Mini 3-1/3.5-1
4-2/6-2
L N
L N GRD L L GRD Mini
WWW.STIEBEL-ELTRON-USA.COM MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS | 5
OPERATION
OVERVIEW
THIS MANUAL MUST BE READ CAREFULLY BEFORE ATTEMPTING TO INSTALL THE MINI WATER HEATER. IF YOU DO NOT FOLLOW THE SAFETY RULES OR THE INSTRUCTIONS OUTLINED IN THIS MANUAL, THE UNIT MAY NOT OPERATE PROPERLY AND IT COULD CAUSE PROPERTY DAMAGE, SERIOUS BODILY INJURY AND/OR DEATH.
STIEBEL ELTRON, INC. WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OUTLINED IN THIS MANUAL OR BECAUSE OF IMPROPER USE. IMPROPER USE INCLUDES THE USE OF THIS APPLIANCE TO HEAT ANY LIQUID OTHER THAN WATER. FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OR IMPROPER USE VOIDS WARRANTY. NEVER REMOVE THE UNIT’S COVER UNLESS THE ELECTRICITY IS TURNED OFF.
IF YOU HAVE ANY QUESTIONS REGARDING THE INSTALLATION OR OPERATION OF THIS WATER HEATER, OR IF YOU NEED ANY ADDITIONAL INSTALLATION MANUALS, PLEASE CALL OUR TECHNICAL SERVICE LINE ON 800-582-8423 (USA AND CANADA ONLY). IF YOU ARE CALLING FROM OUTSIDE THE U.S. OR CANADA, PLEASE CALL USA 413-247-3380 AND WE WILL REFER YOU TO A QUALIFIED STIEBEL ELTRON SERVICE REPRESENTATIVE IN YOUR AREA.
6. Overview
6.1 Figure legend
1 Hot water connection
2 Cold water connection with fi lter screen 3 Filter screen 4 Mounting holes 5
Electrical junction box 6 Water supply line for faucet installation 7 Sink 8 Cold valve (right) 9 Hot valve (left) 10
Shut off valve 11
Reset button from safety pressure cut out
6.2 General Description
The Mini tankless water heater differs from conventional storage type water heaters in several ways. It does not store hot water. Instead, water is heated instantaneously as it fl ows through the unit. The powerful heating elements are activated by a fl ow switch as water is drawn from a hot water faucet connected to the Mini. Due to the absence of stand-by losses, the Mini offers greater energy effi ciency than storage type water heaters. The unit will continuously supply hot water as long as the faucet is open.
The temperature of the hot water delivered by the Mini depends on the wattage of the heating element, the temperature of the incoming cold water, and the water fl ow rate through the unit. In order for the Mini to operate properly, it must be carefully matched to the application. In case you have questions regarding the way you plan to use the Mini, please call our technical service line at 800-582-8423 (USA and Canada). For service outside the U.S. and Canada, please call us at USA 413-247-3380. You can also e-mail us at info@stiebel­eltron-usa.com or fax us at 413-247-3369.
The Mini can be used for hand washing type applications in the U.S. and Canada:
– Restroom sinks in commercial/industrial facilities and homes – Kitchen areas in commercial /industrial facilities and homes – Cabins – Special uses in photo developing shops, laboratories etc.
The Mini can also be used for whole apartments and homes in warm climate zones such as the Caribbean region, Central America and Mexico due to the higher ambient water temperatures.
6.3 Important information before supplying power to unit
Air in the cold water pipe will destroy the bare-wire
heating system of the Mini. If the water supply to the Mini has been interrupted, for example due to the risk of frost or work on the water pipe, the following steps must be carried out before the unit is used again.
» 1. Turn off circuit breaker. » 2. Open a hot water tap downstream of the unit for as long as
is necessary for the unit and the cold water pipe to be free of air.
» 3. Turn on circuit breaker.
All information in these Instructions for Use and Installation must be followed carefully. They provide important information with regard to safety, operation, installation, and maintenance of the device.
6 | MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
OPERATION
OPERATING AND INSTALLATION INSTRUCTIONS
6.4 Hot water output
Model Wattage Typical hot water
output
Mini 2-1* 1.8 kW 0.32 GPM Mini 2.5-1 2.4 kW 0.50 GPM Mini 3-1 3.0 kW 0.50 GPM Mini 3.5-1 3.5 kW 0.66 GPM Mini 4-2 3.5 kW 0.66 GPM Mini 6-2 5.7 kW 1.00 GPM
*Note: Mini 2-1 is internally restricted to 0.32 GPM
6.5 Incorrect use
The following are not permitted and will void the factory warranty:
- Installation of the appliance where it is at risk from frost
- Installation in rooms where the appliance is at risk from explosions as a result of dust, gases or vapors
- Ignoring safety clearances and safety zones
- Incorrect power connection
- Operation of the appliance without water fl owing through the unit, or with air in the lines (see "Initial startup", section 8, pg.
10)
- Operation of the unit with the cover off
- Heating liquids other than potable water
6.6 First steps to be taken in the event of malfunction
WARNING: ALWAYS SHUT OFF POWER AND WATER TO
THE UNIT PRIOR TO REMOVING THE FILTER SCREEN. FAILURE TO DO SO MAY CAUSE SERIOUS BODILY INJURY OR DEATH.
A damp cloth is suffi cient for cleaning of the unit's housing. Do not use any abrasive or corrosive cleaning agents.
7. Operating and installation instructions
KEEP THESE INSTRUCTIONS CAREFULLY AND PASS THEM
ON TO YOUR SUCCESSOR IN THE EVENT OF A CHANGE IN OWNERSHIP, IN THE EVENT OF MAINTENANCE AND POSSIBLE REPAIR WORK THEY SHOULD BE PASSED TO THE QUALIFIED INSTALLER FOR HIS OR HER REFERENCE.
7.1 Mounting the unit
UNIT MUST BE INSTALLED WITH THE PLUMBING
!
CONNECTIONS POINTING DOWNWARD OR UPWARD ONLY.
WARNING: DO NOT INSTALL UNIT WHERE IT WOULD
ROUTINELY BE SPLASHED WITH WATER. ELECTRIC SHOCK
OR DEATH MAY RESULT.
» 1. Install Mini as close as possible to the hot water draw-off
point, for example, directly underneath the sink or next to the shower stall.
» 2. Install Mini in a frost free area. If frost may occur, remove
unit before freezing temperatures set in.
» 3. Leave a minimum of 5" of clearance on all sides for
servicing.
» 4. Remove plastic cover by removing screws located on the left
and right sides of the unit B.
» 5. Remove plastic backplate by pulling on the tab with a
screwdriver B.
» 6. Mount backplate securely to wall by putting two screws
through mounting holes
» 7. Snap unit back onto mounting plate » 8. Reinstall cover with screws on left and right side of unit
7.2 Plumbing connections
A B
.
.
B
.
B
ENGLISH
» Check the circuit breaker » Check the fi lter screen for scale blockage or dirt accumulation.
See also ”Troubleshooting” section 10 pg. 11.
6.7 Maintenance and care
MAINTENANCE WORK, SUCH AS CHECKING ELECTRICAL
!
SAFETY, MAY ONLY BE CARRIED OUT BY A QUALIFIED
INSTALLER.
WARNING: ALWAYS SHUT OFF POWER AND WATER TO
THE UNIT PRIOR TO REMOVING THE FILTER SCREEN. FAILURE TO DO SO MAY CAUSE SERIOUS BODILY INJURY OR DEATH.
Regularly clean and descale the fi lter screen located in the cold water inlet connection and if necessary replace. Always shut off power and water to the unit prior to removing the fi lter screen.
WWW.STIEBEL-ELTRON-USA.COM MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS | 7
IN ORDER TO AVOID DAMAGE. EXCESSIVE HEAT FROM SOLDERING ON COP PER PIPES NEAR THE MINI MAY CAUSE DAMAGE. ALL PLUMBING WORK MUST COMPLY WITH NATIONAL AND APPLICABLE STATE AND LOCAL PLUMBING CODES.
NOTE: IF SOLDERING NEAR THE UNIT IS NECESSARY, PLEASE
DIRECT THE FLAME AWAY FROM THE HOUSING OF THE UNIT
» 1. All plumbing work must comply with national and
applicable state and local plumbing codes.
» 2. A pressure reducing valve must be installed if the cold water
supply pressure exceeds 150 PSI (10 bar).
» 3. Make certain that the cold water supply line has been
fl ushed to remove any scale and dirt.
» 4. Install isolating valve in cold water line as shown in
illustration C. This allows the unit to be isolated for maintenance purposes.
» 5. Cold water connection (inlet) is on the right side of the unit,
hot water connection (outlet) is on the left side of unit.
INSTALLATION
elec tr
o n ic
°C
INITIAL START-UP
» 6. Tankless water heaters such as the Mini are not required
to be equipped with a Pressure and Temperature Relief Valve (except in Massachusetts). If the local inspector will not pass the installation without a P+T valve, it should be installed on the hot water outlet side of unit.
» 7. The Mini is designed for connection to a braided stainless
steel hose with a 3/8“ OD Tube Outlet.
» 8. When all plumbing work is completed, check for leaks and
take corrective action before proceeding.
7.3 Electrical connection
WARNING: BEFORE BEGINNING ANY WORK ON THE
ELECTRIC INSTALLATION, BE SURE THAT THE MAIN CIRCUIT BREAKER PANEL SWITCH IS "OFF" TO AVOID ANY DANGER OF ELECTRIC SHOCK. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. ALL MOUNTING AND PLUMBING MUST BE COMPLETED BEFORE PROCEEDING WITH ELECTRICAL HOOK-UP. WHERE REQUIRED BY LOCAL, STATE OR NATIONAL ELECTRICAL CODES, THE CIRCUIT SHOULD BE EQUIPPED WITH A GROUND FAULT INTERRUPTER.
WARNING: AS WITH ANY ELECTRIC APPLIANCE, FAILURE TO ELECTRICALLY GROUND UNIT MAY RESULT IN SERIOUS INJURY OR DEATH.
CAUTION: INSTALLING A MINI 2-1, MINI 2.5-1, MINI 3-1, OR MINI 3.5-1 ON A 208 V OR 220 - 240 V CIRCUIT WILL DESTROY THE HEATING ELEMENT. THIS IS CONSIDERED IMPROPER INSTALLATION AND WILL VOID YOUR FACTORY WARRANTY.
Voltage
Mini 2-1: 115–125 V Mini 2.5-1: 115–125 V Mini 3-1: 115–125 V Mini 3.5-1: 115–125 V Mini 4-2: 240, 208 V Mini 6-2: 240, 208 V
1. All electrical work must comply with national and applicable state and local electrical codes.
2. The Mini should be connected to a properly grounded dedicated branch circuit of proper voltage rating. In installa tions with several Mini units, each unit requires an independent circuit. Please refer to the technical data table for the correct wire and circuit breaker size.
3. The open ends of the "pigtail" must be feed into an electrical junction box. Then feed wires through strain relief clamp and tighten clamp down on wire.
4. Reinstall plastic cover.
8. Initial start-up
WARNING: OPEN HOT WATER FAUCET FOR A FEW MINUTES
!
UNTIL WATER FLOW IS CONTINUOUS AND ALL AIR IS PURGED FROM WATER PIPES. THE UNIT’S PLASTIC COVER MUST BE INSTALLED BEFORE THE CIRCUIT BREAKER IS TURNED ON.
1
on
2
on
26_02_02_0436
9. Water heater hand over
Explain the functions of the unit to the user and familiarize him or her with its use.
Important instructions:
» Draw the user’s attention to possible hazards (scalding). » Hand over these instructions for future reference. » In order to obtain a proper temperature at a single spout
mixer-type faucet, restrict cold water fl ow to faucet by partially closing the cold water shut-off valve under the sink until cold water and hot water fl ow rates are approximately the same.
10. Normal maintenance
CAUTION: OTHER THAN THE FILTER SCREEN, THE MINI
!
DOES NOT CONTAIN ANY PARTS SERVICEABLE BY THE LAY PERSON. IN CASE OF MALFUNCTION PLEASE CONTACT A LICENSED PLUMBER OR ELECTRICIAN.
Stiebel Eltron Mini tankless heaters are designed for a very long service life. Actual life expectancy will vary with water quality and use. The unit itself does not require any regular maintenance. However, to ensure consistent water fl ow, it is recommended to periodically remove scale and dirt that may build up at the aerator of the faucet or in the shower head. Also, the Mini has a built in fi lter screen that should be cleaned from time to time. In order to do this, turn off the cold water supply at the isolating valve. Clean screen and put the screen back into its original position.
8 | MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
INSTALLATION
TECHNICAL DATA
11. Technical data
Model
Mini 2-1 Min i 2.5-1 Mini 3-1 Mini 3.5-1 Mini 4-2 Mini 6-2
Item number 231045 232098 220816 232099 222039 220817 Phase 1 1 1 1 1 1 Voltage V 115 - 125 115 - 125 115 - 125 115 - 125 208 240 208 240 Wattage kW 1.8 2.4 3.0 3.5 2.9 3.5 4.7 5.7 Max. amp, load A 16 21 25 31 13.8 15.2 22.4 24.7 Min. required circuit
breaker size A 20 30 30 40 20 20 30 30 Required wire size AWG COPPER 12 10 10 10 12 12 10 10 Min. water flow to
activate unit
GPM
(l/min)
0.21
(0.8)
0.40
(1.5)
0.40
(1.5)
0.40
(1.5)
0.40
(1.5)
0.77
(2.9)
Recommended inlet temp. range
°F (°C) 41-77 (5-25) Nominal water volume GAL (l) 0.026 (0.1) Working pressure,
max. PSI (bar) 150 (10) Tested to pressure PSI (bar) 300 (20) Weight lbs. (kg) 3.44 (1.56) Dimensions
1
Height Depth Width
inch (mm) inch (mm) inch (mm)
/
6
(165)
2 1
/
3
(82)
4
1
/
7
(190)
2
Water connections for 3/8˝ O.D. flex connector
ENGLISH
Heating System Nichrome bare-wire
Mini™ 2-1 models are internally restricted to 0.32 gpm. Mini™ 2-1, 2.5-1, 3-1 ship with a 0.5 gpm pressure compensating fl ow reducer/aerator that should be installed. Mini™ 3.5-1, 4-2 ship with a 0.66 gpm pressure compensating fl ow reducer/aerator that should be installed.
-Tankless water heaters are considered a non-continuous load
-Conductors should be sized to maintain a voltage drop of less than 3 % under load
-For use with cold water supply only
12. Troubleshooting
E
Symptom Possible cause Solution
No hot water despite fully opened hot water faucet.
WWW.STIEBEL-ELTRON-USA.COM MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS | 9
No electrical power. Check the circuit breaker and
check voltage at the wiring block.
The activation fl ow rate needed to
Clean fi lter screen. turn on the heating element has not been reached.
Safety cut out tripped – turn circuit breakers off
– open Hot Valve to release pres-
sure from the unit – reset saftey pressure cut out – turn circuit breakers on
E
INSTALLATION
SPARE PARTS
13. Spare parts
No. Model
Spare part
1 Front cover 271010 2 Rear housing 271011 3 Filter screen 272884 4 Plumbing connection 272777 5 O-rings 083043
Mini 2-1 Mini 2.5-1 Mini 3-1 Mini 3.5-1 Mini 4-2 Mini 6-2
14. Warranty
1
2
4
3
Residential & commercial warranty: Stiebel Eltron, Inc. warrants to the original owner that the Mini tankless electric water heater will be free from defects in workmanship and materials for a period of three (3) years from the date of purchase, and free from leak age for a period of seven (7) years from the date of purchase. Should the part(s) prove to be defective under normal use during this period, Stiebel Eltron, Inc. will be responsible for replacement of the defective part(s) only. Stiebel Eltron, Inc. is not responsible for labor charges to remove and/or replace the defective part(s), or any incidential or consequential expenses. Should the owner wish to return the tankless electric water heater for repair, the owner must fi rst secure written au­thorization from Stiebel Eltron, Inc. The owner shall be required to show proof of purchase date, and to pay all trans­portation costs to return the defective part(s) or tankless electric water heater for repair or replacement. Warranty is void if water heater has been installed or used improperly or if design has been altered in any way.
The installation, electrical connection and first operati-
!
on of this appliance should be carried out by a qualified
installer.
The company does not accept liability for failure of any
!
goods supplied which have not been installed and ope-
rated in accordance with the manufacturer‘s instructions.
Environment and recycling
Please help us to protect the environment by disposing of the packaging in accordance with the national regulations for waste processing.
STIEBEL ELTRON, INC.
17 West Street West Hatfi eld, MA 01088, USA
PHONE: 800-582-8423 or 413-247-3380 FAX: 413-247-3369 E-Mail info@stiebel-eltron-usa.com www.stiebel-eltron-usa.com
10 | MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
Loading...
+ 22 hidden pages