STIEBEL ELTRON MINI 2-1, MINI 2.5-1, MINI 3-1, MINI 3.5-1, MINI 6-2 Operation And Installation Manual

...
OPERATION AND INSTALLATION FUNCIONAMIENTO E INSTALACIÓN MODE D’EMPLOI ET INSTALLATION
TANKLESS ELECTRIC WATER HEATER WITH ELECTROMECHANICAL FLOW SWITCH CALENTADOR ELÉCTRICO DE AGUA SIN TANQUE CON SENSOR ELECTROMECÁNICO DE FLUJO CHAUFFE-EAU ÉLECTRIQUE SANS RÉSERVOIR AVEC CONTACTEUR DEBITMETRIQUE ÉLECTROMÉCANIQUE
» MINI™ 2-1 » MINI™ 2.5-1 » MINI™ 3-1
» MINI™ 3.5-1 » MINI™ 4-2 » MINI™ 6-2
Conforms to ANSI/UL Std. 499 Certified to CAN/CSA Std. E335-1 & E335-2-35
Conforme a ANSI/UL Std. 499 Certificación con CAN/CSA Std. E335-1 & E335-2-35
Conforme à la norme ANSI/UL Std. 499 Certifié à la norme CAN/CSA Std. E335-1 & E335-2-35
Tested and certified by WQA to NSF/ANSI372 for lead free compliance.
Probado y certificado por WQA NSF/ANSI 372 para el cumplimiento de las regulaciones sin plomo.
Testé et certifié par WQA à la NSF/ANSI 372 pour une utilisation sans plomb.
2 | MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
GENERAL INFORMATION
1. General Information
Read this entire manual. Failure to follow all the guides, instructions and rules could cause personal injury or property damage. Improper installation, adjustment, alteration, service and use of this unit can result in serious injury.
This unit must be installed by a licensed electrician and plumber. The installation must comply with all national, state and local plumbing and electric codes. Proper installation is the responsibility of the installer. Failure to comply with the installation and operating instructions or improper use voids the warranty.
Save these instructions for future reference. Installer should leave these instructions with the consumer.
If you have any questions regarding the installation, use or operation of this water heater, or if you need any additional installation manuals, please call our technical service line at 800­582-8423 (USA and Canada only). If you are calling from outside the USA or Canada, please call USA 413-247-3380 and we will refer you to a qualified Stiebel Eltron service representative in your area.
1. General Information __________________________________________ 2
1.1 Symbol key ___________________________________________________________ 3
2. Safety precautions ____________________________________________ 4
3. Register your product ________________________________________5
4. Temperature increase above ambient water temperature 6
5. Technical drawings ___________________________________________7
6. Overview _____________________________________________________10
6.1 General Description _______________________________________________10
6.2 Important information before supplying power to unit____11
6.3 Hot water output ___________________________________________________ 11
6.4 Incorrect use ________________________________________________________12
6.5 First steps to be taken in the event of malfunction _________12
6.6 Maintenance and care ____________________________________________13
7. Installation instructions _____________________________________13
7.1 Mounting the unit _________________________________________________13
7.2 Plumbing connections ____________________________________________ 14
7.3 Electrical connection ______________________________________________ 15
8. Initial start-up _______________________________________________16
9. Water heater hand over _____________________________________ 16
10. Normal maintenance ________________________________________17
11. Technical data ________________________________________________18
12. Troubleshooting ______________________________________________20
13. Spare parts ___________________________________________________21
14. Warranty _____________________________________________________22
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS | 3
GENERAL INFORMATION
!
THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT
YOU TO POTENTIAL PERSONAL INJURY HAZARD. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO AVOID POSSIBLE INJURY OR DEATH.
The chapter Operation is intended for homeowners, heating contractors, plumbers and electricians.
The chapter Installation is intended for heating contractors, plumbers and electricians only.
1.1 Symbol key
1.1.1 Layout of safety information
DANGER Electric shock
Before any work on the appliance, disconnect all poles from the power supply.
1
3
4
2
1 Symbol (see 1.1.2 “Symbols”, below) 2 Keyword (see 1.1.3 “Keywords”, below) 3 Description (see 1.1.2 “Symbols”, below) 4 Information text
1.1.2 Symbols
Symbol Description
Injury
Electrocution
Burns or scalding
!
Other situations
4 | MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
SAFETY PRECAUTIONS
1.1.3 Keywords
KEYWORD
DANGER
The keyword DANGER indicates information that must be observed, otherwise serious injury or death will result.
WARNING The keyword WARNING indicates information that
must be observed, otherwise serious injury or death may result.
CAUTION
The keyword CAUTION indicates information that must be observed, otherwise relatively serious or light injuries may result.
2. Safety precautions
!
PLEASE READ AND FOLLOW THESE INSTRUCTIONS. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD
RESULT IN SERIOUS BODILY INJURY OR DEATH.
THE UNIT MUST BE INSTALLED BY A LICENSED ELECTRICIAN AND PLUMBER. THE INSTALLATION MUST COMPLY WITH ALL NATIONAL, STATE AND LOCAL PLUMBING AND ELECTRIC CODES.
SERVICE OF THE UNIT MUST BE PERFORMED BY QUALIFIED SERVICE TECHNICIANS.
BEFORE PROCEEDING WITH ANY INSTALLATION,
ADJUSTMENT, ALTERATION, OR SERVICE OF THIS UNIT ALL CIRCUIT BREAKERS AND DISCONNECT SWITCHES SERVICING THE UNIT MUST BE TURNED OFF. FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURY OR DEATH.
DANGER: NEVER REMOVE THE UNIT'S COVER UNLESS
THE ELECTRICITY SERVICING THE UNIT IS TURNED OFF. FAILURE TO DO SO COULD RESULT IN PERSONAL INJURY OR DEATH.
WARNING: THE UNIT MUST BE PROPERLY GROUNDED.
FAILURE TO ELECTRICALLY GROUND THE PRODUCT COULD RESULT IN SERIOUS PERSONAL INJURY OR DEATH.
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS | 5
REGISTER YOUR PRODUCT
DANGER: WATER TEMPERATURES OVER 125 °F (52 °C)
CAN CAUSE SEVERE BURNS INSTANTLY OR DEATH FROM SCALDING. A HOT WATER SCALDING POTENTIAL EXISTS IF THE THERMOSTAT ON THE UNIT IS SET TOO HIGH. HOUSEHOLDS WITH SMALL CHILDREN, DISABLED OR ELDERLY PERSONS MAY REQUIRE THAT THE THERMOSTAT BE SET AT 120 °F (49 °C) OR LOWER TO PREVENT POSSIBLE INJURY FROM HOT WATER.
3. Register your product
YOU MUST REGISTER THIS PRODUCT WITHIN 90 DAYS OF PURCHASE ON OUR WEB SITE IN ORDER TO ACTIVATE THE
STANDARD WARRANTY OR TO BE ELIGIBLE FOR THE EXTENDED WARRANT Y. GO TO OUR WEB SITE AT WWW.STIEBEL-ELTRON-USA. COM AND CLICK ON REGISTER YOUR PRODUCT.
Before beginning the registration process, we suggest that you gather the necessary information which will be as follows:
Type, Example: Mini 3-1 (from the white label that is on the right side of the unit)
Number listed after "Nr." Place of Purchase Purchase Date First & Last Name Email address Physical Address Phone Number
IF YOU HAVE ANY QUESTIONS CONCERNING THE REGISTRATION PROCESS OR WARRANTY OPTIONS, PLEASE CONTACT STIEBEL ELTRON USA DIRECTLY AT (800)-582-8423.
6 | MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
TEMPERATURE INCREASE ABOVE AMBIENT WATER TEMPERATURE
4. Temperature increase above ambient water temperature
Temp. rise above incoming water temp. (°F) Temp. rise above incoming water temp. (°C)
GPM l/m
Unit Heating Capacity 0.32 0.42 0.48 0.53 0.69 0.85 1.06 1.14 1.2 1.6 1.8 2.0 2.6 3.2 4.0 4.3
Mini 2-1 1.8 kW @ 110-120 V 39 - - - - - - - 22 - - - - - - ­Mini 2.5-1 2.4 kW @ 110-120 V - 39 34 33 24 - - - - 22 19 17 13 - - ­Mini 3-1 3.0 kW @ 110-120 V - 49 43 41 30 - - - - 27 24 22 17 - - ­Mini 3.5-1 3.5 kW @ 110-120 V - 57 50 45 35 - - - - 31 28 25 19 - - ­Mini 4-2 3.5 kW @ 220-240 V - 57 50 45 35 - - - - 31 28 25 19 - - ­Mini 6-2 5.7 kW @ 220-240 V - - - - - 46 37 34 - - - - - 25.5 20.4 19.0
* Note: Mini 2-1 is internally restricted to 1.2 l/min (0.32 gpm)
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS | 7
TECHNICAL DRAWINGS
5. Technical drawings
A
5 /
5
8
” (143 mm)
3
/
16
” (4,8 mm)
13
/16 (20 mm)
1/
3
16
” (30 mm)
4
¾
” (120 mm)
6 ½
(165 mm)
7½” (190 mm)
3¼” (82 mm)
3/8” O.D. flex connector
3 ¾ ” (95
mm)
1
2
4
3
1 Hot water connection 2 Cold water connection 3 Filter screen 4 Mounting holes
13
/16 ” (20 mm)
6 ½ ”
(165 mm)
3¼” (82 mm)
3/8” O.D. flex connector
A
8 | MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
TECHNICAL DRAWINGS
B B
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS | 9
TECHNICAL DRAWINGS
C
C26_02_05_0010
5
6
7
89
10
5
Electrical junction box 6 Water supply line 7 Sink 8 Cold valve (right) 9 Hot valve (left) 10
Shut off valve 11
Reset button from safety pressure cut out
D
V >
p >
L N
L N GND
Mini
2-1/2.5-1
3-1/3.5-1
L L GNDMini
4-2/6-2
10 | MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
OVERVIEW
!
THIS MANUAL MUST BE READ CAREFULLY BEFORE AT-
TEMPTING TO INSTALL THE Mini WATER HEATER. IF YOU DO NOT FOLLOW THE SAFETY RULES OR THE INSTRUCTIONS OUTLINED IN THIS MANUAL, THE UNIT MAY NOT OPERATE PROPERLY AND IT COULD CAUSE PROPERTY DAMAGE, SERIOUS BODILY INJURY AND/OR DEATH.
STIEBEL ELTRON, INC. WILL NOT BE LIABLE FOR ANY DAMAGES BE­CAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION AND OPER­ATING INSTRUCTIONS OUTLINED IN THIS MANUAL OR BECAUSE OF IMPROPER USE. IMPROPER USE INCLUDES THE USE OF THIS APPLIANCE TO HEAT ANY LIQUID OTHER THAN WATER. FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OR IMPROPER USE VOIDS WARRANTY. NEVER REMOVE THE UNIT’S COVER UNLESS THE ELECTRICITY IS TURNED OFF.
IF YOU HAVE ANY QUESTIONS REGARDING THE INSTALLATION OR OP­ERATION OF THIS WATER HEATER, OR IF YOU NEED ANY ADDITIONAL INSTALLATION MANUALS, PLEASE CALL OUR TECHNICAL SERVICE LINE ON 800-582-8423 (USA AND CANADA ONLY). IF YOU ARE CALLING FROM OUTSIDE THE U.S. OR CANADA, PLEASE CALL USA 413-247-3380 AND WE WILL REFER YOU TO A QUALIFIED STIEBEL ELTRON SERVICE REPRE­SENTATIVE IN YOUR AREA.
6. Overview
6.1 General Description
The Mini tankless water heater differs from conventional storage type water heaters in several ways. It does not store hot water. Instead, water is heated instantaneously as it flows through the unit. The powerful heating elements are activated by a flow switch as water is drawn from a hot water faucet connected to the Mini. Due to the absence of stand-by losses, the Mini offers greater energy efficiency than storage type water heaters. The unit will continuously supply hot water as long as the faucet is open. The temperature of the hot water delivered by the Mini depends on the wattage of the heating element, the temperature of the incoming cold water, and the water flow rate through the unit. In order for the Mini to operate properly, it must be carefully matched to the application. In case you have questions regarding the way you plan to use the Mini, please call our technical service line at 800-582-8423 (USA and Canada). For service outside the U.S. and Canada, please call us at USA 413-247-3380. You can also e-mail us at info@stiebel­eltron-usa.com or fax us at 413-247-3369.
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS | 11
OVERVIEW
The Mini can be used for hand washing type applications in the U.S. and Canada:
– Restroom sinks in commercial/industrial facilities and homes – Kitchen areas in commercial /industrial facilities and homes – Cabins – Special uses in photo developing shops, laboratories etc.
The Mini can also be used for whole apartments and homes in warm climate zones such as the Caribbean region, Central America and Mexico due to the higher ambient water temperatures.
6.2 Important information before supplying power to unit
Air in the cold water pipe will destroy the bare-wire
heating system of the Mini. If the water supply to the Mini has been interrupted, for example due to the risk of frost or work on the water pipe, the following steps must be carried out before the unit is used again.
» 1. Turn off circuit breaker.
» 2. Open a hot water tap downstream of the unit for as long as
is necessary for the unit and the cold water pipe to be free of air.
» 3. Turn on circuit breaker.
All information in these Instructions for Use and Installation must be followed carefully. They provide important information with regard to safety, operation, installation, and maintenance of the device.
12 | MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
OVERVIEW
6.3 Hot water output
Model Wattage at
max rated voltage
Typical hot water output
Mini 2-1 1.8 kW 0.32 gpm / 1.2 l/min Mini 2.5-1 2.4 kW 0.50 gpm / 1.9 l/min Mini 3-1 3.0 kW 0.50 gpm / 1.9 l/min Mini 3.5-1 3.5 kW 0.66 gpm / 2.5 l/min Mini 4-2 3.5 kW 0.66 gpm / 2.5 l/min Mini 6-2 5.7 kW 1.00 gpm / 3.8 l/min
Mini 2-1 models are internally restricted to 0.32 gpm (1.2 l/ min). Mini 2-1, 2.5-1, 3-1 ship with a 0.5 gpm (1.9 l/min) pressure compensating flow reducer/aerator that must be installed. Mini 3.5-1, 4-2 ship with a 0.66 gpm (2.5 l/min) pressure compensating flow reducer/aerator that must be installed.
6.4 Incorrect use
The following are not permitted and will void the factory warranty:
- Installation of the appliance where it is at risk from frost
- Installation in rooms where the appliance is at risk from explosions as a result of dust, gases or vapors
- Ignoring safety clearances and safety zones
- Incorrect power connection
- Operation of the appliance without water flowing through the unit, or with air in the lines (See section 8, “Initial start-up”, pg. 16)
- Operation of the unit with the cover off
- Heating liquids other than potable water
6.5 First steps to be taken in the event of malfunction
WARNING: ALWAYS SHUT OFF POWER AND WATER TO
THE UNIT PRIOR TO REMOVING THE FILTER SCREEN. FAILURE TO DO SO MAY CAUSE SERIOUS BODILY INJURY OR DEATH.
» Check the circuit breaker
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS | 13
INSTALLATION INSTRUCTIONS
» Check the filter screen for scale blockage or dirt accumulation.
See section 12, “Troubleshooting”, pg. 19.
6.6 Maintenance and care
!
MAINTENANCE WORK, SUCH AS CHECKING ELECTRICAL SAFETY, MAY ONLY BE CARRIED OUT BY A QUALIFIED
INSTALLER.
WARNING: ALWAYS SHUT OFF POWER AND WATER TO
THE UNIT PRIOR TO REMOVING THE FILTER SCREEN. FAILURE TO DO SO MAY CAUSE SERIOUS BODILY INJURY OR DEATH.
Regularly clean and descale the filter screen located in the cold water inlet connection and if necessary replace. Always shut off power and water to the unit prior to removing the filter screen.
A damp cloth is sufficient for cleaning of the unit's housing. Do not use any abrasive or corrosive cleaning agents.
7. Installation instructions
KEEP THESE INSTRUCTIONS CAREFULLY AND PASS THEM
ON TO YOUR SUCCESSOR IN THE EVENT OF A CHANGE IN OWNERSHIP, IN THE EVENT OF MAINTENANCE AND POSSIBLE REPAIR WORK THEY SHOULD BE PASSED TO THE QUALIFIED INSTALLER FOR HIS OR HER REFERENCE.
7.1 Mounting the unit
!
UNIT MUST BE INSTALLED WITH THE PLUMBING
CONNECTIONS POINTING DOWNWARD OR UPWARD ONLY.
WARNING: DO NOT INSTALL UNIT WHERE IT WOULD ROUTINELY BE SPLASHED WITH WATER. ELECTRIC SHOCK
OR DEATH MAY RESULT.
» 1. Install Mini as close as possible to the hot water draw-off
point, for example, directly underneath the sink or next to the shower stall.
» 2. Install Mini in a frost free area. If frost may occur, remove
unit before freezing temperatures set in.
» 3. Leave a minimum of 5" of clearance on all sides for
servicing.
14 | MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
INSTALLATION INSTRUCTIONS
» 4. Remove plastic cover by removing screws located on the left
and right sides of the unit B.
» 5. Remove plastic backplate by pulling on the tab with a
screwdriver
B
.
» 6. Mount backplate securely to wall by putting two screws
through mounting holes
A B
.
» 7. Snap unit back onto mounting plate
B
.
» 8. Reinstall cover with screws on left and right side of unit
B
.
7.2 Plumbing connections
NOTE: IF SOLDERING NEAR THE UNIT IS NECESSARY, PLEASE
DIRECT THE FLAME AWAY FROM THE HOUSING OF THE UNIT IN ORDER TO AVOID DAMAGE. EXCESSIVE HEAT FROM SOLDERING ON COP PER PIPES NEAR THE MINI MAY CAUSE DAMAGE. ALL PLUMBING WORK MUST COMPLY WITH NATIONAL AND APPLICABLE STATE AND LOCAL PLUMBING CODES.
» 1. All plumbing work must comply with national and
applicable state and local plumbing codes.
» 2. A pressure reducing valve must be installed if the cold water
supply pressure exceeds 150 PSI (10 bar).
» 3. Make certain that the cold water supply line has been
flushed to remove any scale and dirt.
» 4. Install isolating valve in cold water line as shown in
illustration
C
. This allows the unit to be isolated for
maintenance purposes.
» 5. Cold water connection (inlet) is on the right side of the unit,
hot water connection (outlet) is on the left side of unit.
» 6. Tankless water heaters such as the Mini are not required
to be equipped with a Pressure and Temperature Relief Valve (except in Massachusetts). If the local inspector will not pass the installation without a P+T valve, it should be installed on the hot water outlet side of unit.
» 7. The Mini is designed for connection to a braided stainless
steel hose with a 3/8˝ O.D. Tube Outlet.
» 8. When all plumbing work is completed, check for leaks and
take corrective action before proceeding.
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS | 15
INSTALLATION INSTRUCTIONS
7.3 Electrical connection
WARNING: BEFORE BEGINNING ANY WORK ON THE
ELECTRIC INSTALLATION, BE SURE THAT THE MAIN CIRCUIT BREAKER PANEL SWITCH IS “OFF” TO AVOID ANY DANGER OF ELECTRIC SHOCK. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. ALL MOUNTING AND PLUMBING MUST BE COMPLETED BEFORE PROCEEDING WITH ELECTRICAL HOOK-UP. WHERE REQUIRED BY LOCAL, STATE OR NATIONAL ELECTRICAL CODES, THE CIRCUIT SHOULD BE EQUIPPED WITH A GROUND FAULT INTERRUPTER.
WARNING: AS WITH ANY ELECTRIC APPLIANCE, FAILURE TO ELECTRICALLY GROUND UNIT MAY RESULT IN SERIOUS INJURY OR DEATH.
CAUTION: INSTALLING A MINI 2-1, MINI 2.5-1, MINI 3-1, OR MINI 3.5-1 ON A 208 V OR 220–240 V CIRCUIT WILL DESTROY THE HEATING ELEMENT. THIS IS CONSIDERED IMPROPER INSTALLATION AND WILL VOID YOUR FACTORY WARRANTY.
Voltage
Mini 2-1: 110–120 V Mini 2.5-1: 110–120 V Mini 3-1: 110–120 V Mini 3.5-1: 110–120 V Mini 4-2: 220–240, 208 V Mini 6-2: 220–240, 208 V
1. All electrical work must comply with national and applicable state and local electrical codes.
2. The Mini should be connected to a properly grounded dedicated branch circuit of proper voltage rating. In installa tions with several Mini units, each unit requires an independent circuit. Please refer to the technical data table for the correct wire and circuit breaker size.
3. The open ends of the “pigtail” must be feed into an electrical junction box. Then feed wires through strain relief clamp and tighten clamp down on wire.
4. Reinstall plastic cover.
16 | MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
INITIAL START-UP
8. Initial start-up
!
WARNING: OPEN HOT WATER FAUCET FOR A FEW MINUTES
UNTIL WATER FLOW IS CONTINUOUS AND ALL AIR IS PURGED FROM WATER PIPES. THE UNIT’S PLASTIC COVER MUST BE INSTALLED BEFORE THE CIRCUIT BREAKER IS TURNED ON.
2
1
9. Water heater hand over
Explain the functions of the unit to the user and familiarize him or her with its use.
Important instructions:
» Draw the user’s attention to possible hazards (scalding). » Hand over these instructions for future reference.
» In order to obtain a proper temperature at a single spout
mixer-type faucet, restrict cold water flow to faucet by partially closing the cold water shut-off valve under the sink until cold water and hot water flow rates are approximately the same.
10. Normal maintenance
!
CAUTION: OTHER THAN THE FILTER SCREEN, THE MINI
DOES NOT CONTAIN ANY PARTS SERVICEABLE BY THE LAY PERSON. IN CASE OF MALFUNCTION PLEASE CONTACT A LICENSED PLUMBER OR ELECTRICIAN.
Stiebel Eltron Mini tankless heaters are designed for a very long service life. Actual life expectancy will vary with water quality and use. The unit itself does not require any regular maintenance. However, to ensure consistent water flow, it is recommended to periodically remove scale and dirt that may build up at the aerator of the faucet or in the shower head. Also, the Mini has a built in filter screen that should be cleaned from time to time. In order to do this, turn off the cold water supply at the isolating valve. Clean screen and put the screen back into its original position.
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS | 17
TECHNICAL DATA
11. Technical data
Min i 2-1 Mini 2.5-1 Mini 3-1 Mini 3.5-1 Mini 4-2 Mi ni 6-2
Part number 231045 232098 220816 232099 222039 220817 Electrical data
Phases 1 - 50/60 Hz Voltage
1
110-120 V 110-120 V 110-120 V 110-120 V 220 -240 V 208 V 220-24 0 V 208 V Wattage 1.8 kW 2.4 kW 3.0 kW 3.5 kW 3.5 kW 2.6 kW 5.7 kW 4.3 kW Amperage draw 15 A 20 A 25 A 29 A 15 A 13 A 24 A 21 A Min. recommended circuit breaker size215 A 20 A 25 A 30 A 15 A 25 A Min. recommended wire size3 (copper) 14 AWG 12 AWG 10 AWG 10 AWG 14 AWG 10 AWG Connections Water connection
4
⅜ O.D. flex connector or ⅜ compression fitting Application limits Max. permissible pressure 150 psi / 10 bar Recommended inlet temperature 41–77 °F (5–25 °C) Minimum water flow to activate unit 0.21 gpm / 0.8 l/m 0.40 gpm / 1.5 l/m 0.4 gpm / 1.5 l/m 0.4 gpm / 1.5 l/m 0.40 gpm / 1.5 l/m 0.77 gpm / 2.9 l/m Miscellaneous Heating element Nichrome bare-wire
1
Nominal mains voltage is 110-120V and 220-240V.
2
This is our recommendation for overcurrent protection sized at 100% of load. Check local codes for compliance if necessary.
Tankless water heater are considered a non-continuous load.
3
Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load
4
For use with cold water supply only
18 | MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
TECHNICAL DATA
Min i 2-1 Mini 2.5-1 Mini 3-1 Mini 3.5-1 Mini 4-2 Mi ni 6-2
Dimensions Height 6½ / 143 mm Width 7½ / 190 mm Depth 3¼ / 82 mm Weights Weight 3.3 lbs / 1.5 kg
Mini 2-1 models are internally restricted to 0.32 gpm (1.2 l/min). Mini 2-1, 2.5-1, 3-1 ship with a 0.5 gpm (1.9 l/min) pressure compensating flow reducer/aerator that must be installed. Mini 3.5-1, 4-2 ship with a 0.66 gpm (2.5 l/min) pressure compensating flow reducer/aerator that must be installed.
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS | 19
TROUBLESHOOTING
12. Troubleshooting
E
Symptom Possible cause Solution
No hot water despite fully opened hot water faucet.
No electrical power. Check the circuit breaker and
check voltage at the wiring block.
The activation flow rate needed to turn on the heating element has not been reached.
Clean filter screen.
Safety cut out tripped – turn circuit breakers off
– open Hot Valve to release pres-
sure from the unit
– reset safety pressure cut out
E
– turn circuit breakers on
Safety pressure cut out
20 | MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
SPARE PARTS
13. Spare parts
1
2 Rear housing
3 Filter screen
4 Plumbing connection (incl. 2 O-rings)
Mini Tankless Spare Parts List & Diagram
Spare Part No. Model Mini 2-1, 2.5-1, 3-1, 3.5-1, 4-2, 6-2
271010
271011
275981
272777
1
2
3
4
Front cover
Spare Part (all Mini™ models) Item no.
1 Front cover 271010 2 Rear housing 271011 3 Filter screen 272884 4 Plumbing connections 272777 5 O-rings (not shown) 083043
Loading...