Conforms to ANSI/UL Std. 499
Certifi ed to CAN/CSA Std. E335-1 & E335-2-35
Conforme à la norme ANSI/UL Std. 499
Certifi é à la norme CAN/CSA Std. E335-1 & E335-2-35
HydroShark 12 - HydroShark 36:
Conforms to ANSI/UL Std. 834
Certifi ed to CAN/CSA C22.2 No 64
Conforme à la norme ANSI/UL Std. 834
Certifi é à la norme CAN/CSA C22.2 No 64
HydroShark Electric Boiler (7-36 KW)
Installation Manual and Owner’s Guide
HydroShark 12 - HydroShark 36
UL 834
HydroShark 7 - HydroShark 10
UL 499
The
HydroShark Electric Boiler features advanced
technology, impressive energy-saving performance,
and a compact design. Exclusively manufactured by
Stiebel Eltron, a leader in heating technologies for the
past 80 years.
PARTS LIST...................................................................................................................17
PRESSURE DROP TABLE............................................................................................18
IMPORTANT!
BOILERS ARE TO BE USED FOR RADIANT FLOOR HEATING ONLY!**
THIS MANUAL MUST BE READ CAREFULLY BEFORE ATTEMPTING TO INSTALL THE HydroShark
BOILERS. IF YOU DO NOT FOLLOW THE SAFETY RULES OR THE INSTRUCTIONS OUTLINED
IN THIS MANUAL, THE UNIT MAY NOT OPERATE PROPERLY AND IT COULD CAUSE PROPERTY
DAMAGE, SERIOUS BODILY INJURY AND/OR DEATH.
MANUFACTURER WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY
WITH INSTALLATION AND OPERATING INSTRUCTIONS OUTLINED IN THIS MANUAL OR BECAUSE OF IMPROPER USE. IMPROPER USE INCLUDES THE USE FOR THIS APPLIANCE TO HEAT
ANY LIQUID OTHER THAN WATER OR PROPYLENE GLYCOL. FAILURE TO COMPLY WITH THE
INSTALLATION AND OPERATING INSTRUCTIONS OR IMPROPER USE VOIDS THE WARRANTY.
NEVER REMOVE THE UNITS FRONT COVER UNLESS POWER IS TURNED OFF.
IF YOU HAVE ANY QUESTIONS REGARDING THE INSTALLATION OR OPERATION OF THESE BOILER,
PLEASE CALL OUR TECHNICAL SERVICE LINE AT 800.805.5384.
**Unless when used with Stiebel Eltron DHW Integrator Panels (Use HydroShark 29 or HydroShark 36 KW Boilers only with
Combi Panel Systems, Size boilers accordingly)
WWW.HYDRO-SHARK.COM HYDROSHARK| 3
Installation Manual
CONGRATULATIONS
Congratulations and thank you for choosing our micro boiler. Before use, we
recommend that you read through this installation manual carefully. Keep
this manual for future reference.
If you need an additional manual, contact the manufacturer or your local
distributor. When you call, please tell us the product name and the serial
number of your unit written on the rating plate of the boiler.
4 | HYDROSHARK WWW.HYDRO-SHARK.COM
SPECIFICATIONS
HYDROSHARK
AMP
MODELKWVOLTSWIRE SIZE
HydroShark 77
HydroShark 1010640(1) 5032,765
HydroShark 1212450(1) 7040,956
HydroShark 14142 x 860(2) 4049,147
240
HydroShark 19192 x 680(2) 5065,526
HydroShark 24242 x 4100(2) 7081,912
HydroShark 29293 x 6120(3) 5098,977
HydroShark 36363 x 4150(3) 70122,868
830(1) 4024,573
DRAW
(MAX)
DBL POLE
BREAKER
SIZE
BTU
HydroShark Boiler Temp vs Flow Rate
8
7
6
5
4
with 70 Deg F Return Fluid
____
HydroShark 7
____
HydroShark 10
____
HydroShark 12
____
HydroShark 14
____
HydroShark 19
____
HydroShark 24
____
HydroShark 29
____
HydroShark 36
WATER
TEMP
RANGE
86° - 140° F
3
2
Boiler Flow-GPM
1
0
90100110120130
WWW.HYDRO-SHARK.COM HYDROSHARK| 5
140
DEG F
INTRODUCTION
IMPORTANT!
Read this entire manual. Failure to follow all the guides, instructions and rules could cause personal
injury or property damage. Improper installation, adjustment, alteration, service and use of this unit
can result in serious injury.
This unit must be installed by a licensed electrician and plumber. The installation must comply with
all national, state and local plumbing and electric codes. Proper installation is the responsibility of the
installer. Failure to comply with the installation and operating instructions or improper use voids the
warranty.
Save these instructions for future reference. Installer should leave these instructions with the consumer.
If you have any questions regarding the installation, use or operation of this micro boiler, or if you
need any additional installation manuals call Stiebel Eltron at 800.805.5384 or visit us online at www.
hydro-shark.com
GENERAL
• The output of heat from the boiler is electronically controlled. The boiler will deliver any water temperature between 86° F - 140° F. Set the desired water delivery temperature using the knob on the
front cover. (Do not exceed temperatures above 130° when using this product with tubing in
concrete)
• When the power light is fl ashing, full element power is being applied. When the power light is not
fl ashing, the element power is being modulated to the water delivery temperature.
• Recommend setting for radiant fl oor heating (Tubing in Concrete) is 105° F - 125° F.
• Recommended setting for Staple Up (Floor Warming Only) is 130° - 140° F.
• Temperature setting and water delivery temperatures may vary depending on fl ow rates. Size boil-
er accordingly. See fl ow rate chart for more information.
6 | HYDROSHARK WWW.HYDRO-SHARK.COM
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.