CK, CKT, & CK Trend Technical Data
Certified to ANSI/UL Std. 2021
Technical Data
Model CK 15 E CKT 15 E CK 20 E CKT 20 E CK 150-1 Trend CK 200-2 Trend
Item number 074058 230345 074057 230346 236304 236305
Voltage 120
Wattage 1500
Amperage 12.5
Rated output Btu/hr 5118 5118 6824 5118 6824 5118 5118 6824 6142
Air volume 106
Recommended
circuit breaker size
1
Minimum wire size
(copper)
Timer no yes no yes N/A N/A
Room size estimate 150
Heating element nichrome wire ceramic positive temperature coeffi cient (PTC)
Thermostat & high limit bimetal type bimetal type
Motor 18
Blower galvanized steel, squirrel cage type glass-reinforced polycarbonate, radial type
Dimensions 18
Weight 8.0
Temperature range 41
Frost protection setting 45
Operating noise 49.7 dB(a) 49.0 dB(a)
15
14
sq. ft. 150 sq. ft. 200 sq. ft. 200 sq. ft. 150 sq. ft. 200 sq. ft.
shaded pole 20 W shaded pole
1
/460
/8
˝
lb / 4.4 kg 5.5 lb / 2.5 kg
°F – 86°F / 5°C – 30°C 45 – 95 °F / 7 – 35 °C
°F / 7°C 45°F / 7°C
Conforms to CAN/CSA Std. 22.2 No. 46
120
1500
12.5
106
15
14
mm H x 13
3
/16
˝
/335
240
2000
8.3
106
15
14
mm W x 4
or 208
7.2
240
or 208
2000
8.3
106
15
14
13
/123
/16
mm D 15¾
˝
7.2
120
1500
12.5
70.6
15
14
/400 mm H x 107/
˝
8
˝
/275
240
or 208
2000
8.3
70.6
15
14
mm W x 5
8.7
1
/131
/8
mm D
˝
1
This is our recommendation as the manufacturer. Check local codes for compliance if necessary.
17 West St., W. Hatfield, MA 01088 | 800.582.8423 | 413.247.3380 | fax 413.247.3369 | info
@