Stiebel Eltron 236008, 236136 Installation Manual

OPERATION AND INSTALLATION OPERACIÓN E INSTALACIÓN UTILISATION ET INSTALLATION
THERMOSTATIC POINT-OF-USE TANKLESS ELECTRIC WATER HEATER CALENTADOR DE AGUA ELÉCTRICO SIN TANQUE CON CONTROL TERMOSTÁTICO DE TEMPERATURA CHAUFFE-EAU INSTANTANÉ THERMOSTATIQUES POUR POINT D’UTILISATION
» MINI™-E 2-1 » MINI™-E 2.5-1 » MINI™-E 3-1
Conforms to ANSI/UL Std. 499 Certified to CAN/CSA Std. E335-1 & E335-2-35
Conforme a ANSI/UL Std. 499 Certificación con CAN/CSA Std. E335-1 & E335-2-35
Conforme à la norme ANSI/UL Std. 499 Certifié à la norme CAN/CSA Std. E335-1 & E335-2-35
Tested and certified by WQA to NSF/ANSI372 for lead free compliance.
Probado y certificado por WQA NSF/ANSI 372 para el cumplimiento de las regulaciones sin plomo.
Testé et certifié par WQ A à la NSF/ANSI 372 pour une utilisation sans plomb.
» MINI™-E 3.5-1 » MINI™-E 4-2 » MINI™-E 6-2
TABLE OF CONTENTS
SPECIAL INFORMATION
OPERATION
1. General information ___________________________________________ 3
1.1 Safety instructions __________________________________________________ 4
1.2 Other symbols in this documentation __________________________ 4
2. Safety ____________________________________________________________ 5
2.1 Intended use _________________________________________________________ 5
2.2 General safety instructions _______________________________________ 5
3. Register your product _________________________________________ 6
4. Appliance description _________________________________________ 6
5. Adjustment ______________________________________________________ 7
6. Cleaning, care and maintenance _____________________________ 7
INSTALLATION
7. Safety ____________________________________________________________ 8
7.1 General safety instructions _______________________________________ 8
8. Appliance description _________________________________________ 8
8.1 Standard delivery ___________________________________________________ 8
8.2 Optional accessories _______________________________________________ 8
9. Preparations ____________________________________________________ 8
10. Installation ______________________________________________________ 9
10.1 Installation site ______________________________________________________ 9
10.2 Installation configuration _________________________________________ 9
10.3 Connecting the power supply ___________________________________11
11. Commissioning ________________________________________________12
11.1 Initial start-up ______________________________________________________12
11.2 Appliance handover _______________________________________________12
11.3 Recommissioning __________________________________________________13
11.4 Settings ______________________________________________________________13
12. Shutting down _________________________________________________ 14
13. Troubleshooting _______________________________________________ 14
14. Maintenance ___________________________________________________16
15. Specification ___________________________________________________ 17
15.1 Dimensions and connections ____________________________________17
15.2 Wiring diagram ____________________________________________________18
15.3 Temperature rise table ___________________________________________19
15.4 Data table ___________________________________________________________20
16. Spare parts list ________________________________________________22
17. Warranty _______________________________________________________ 23
2 | MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
GENERAL INFORMATION
SPECIAL INFORMATION
- Ensure the appliance can be separated from the power supply by a circuit breaker that disconnects all poles.
- If the power cable is damaged, it must only be replaced by a qualified contractor and the repair must be authorized by Stiebel Eltron using the original spare part.
- Secure the appliance as described in the section “Installation”, pg. 8.
- Observe the maximum permissible pressure described in section 15.4, “Data table”, pg. 20.
- Drain the appliance as described in the section “Draining the appliance”, pg. 16.
OPERATION
1. General information
The chapter "Operation" is intended for homeowners, heating contractors, plumbers and electricians.
The chapter "Installation" is intended for heating contractors, plumb­ers and electricians only.
Note:
Read these instructions carefully before using the appliance and retain them for future reference. Pass on the instructions to a new user if required.
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS | 3
GENERAL INFORMATION
1.1 Safety instructions
1.1.1 Structure of safety instructions
KEYWORD: Type of risk
Here, possible consequences are listed that may result from failure to observe the safety instructions.
f Steps to prevent the risk are listed.
1.1.2 Symbols, type of risk
Symbol Type of risk
!
Injury
Electrocution
Burns or scalding
1.1.3 Keywords
KEYWORD Meaning
DANGER Failure to observe this information will result in serious
WARNING Failure to observe this information may result in serious
CAUTION Failure to observe this information may result in non-serious
injury or death.
injury or death.
or minor injury.
1.2 Other symbols in this documentation
Note:
Notes are bordered by horizontal lines above and below the text. General information is identified by the symbol shown on the left.
Symbol
!
Material losses (appliance damage, consequential losses and environmental pollution)
Appliance disposal
4 | MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
SAFETY
2. Safety
2.1 Intended use
This appliance is intended for residential use. It can be used safely by untrained persons. The appliance can also be used in a non-res­idential environment, e.g. in a small business, as long as it is used in the same way.
This appliance is suitable for heating domestic hot water (DHW) or for heating preheated water. The appliance is designed for one hand-washing sink.
Note:
The Mini-E 6-2 is the only Mini-E model which is designed to supply hot water to one OR two hand-washing sinks. Plumbing any other Mini-E model to more than one hand-washing sink shall be deemed inappropriate.
Any other use beyond that described shall be deemed inappropriate. Observation of these instructions and of instructions for any acces­sories used is also part of the correct use of this appliance.
2.2 General safety instructions
DANGER: Scalding
During operation, the tap can reach temperatures in excess of 122 °F (50 °C). There is a risk of scalding at outlet temperatures in excess of 109 °F (43 °C).
DANGER: Electrocution
Any damaged power cables must be replaced by a qual­ified electrician. This prevents potential hazards due to improper installation.
Material losses:
!
Protect the appliance and the tap against freezing.
Material losses:
!
Only use the provided aerator(s). Prevent scale build-up at the tap outlets (See chapter 6, “Cleaning, care and main­tenance”, pg. 7).
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS | 5
REGISTER YOUR PRODUCT
3. Register your product
You must register this product within 90 days of purchase on our web site in order to activate the stan­dard warranty or to be eligible for the extended warran­ty. Go to our website at www.stiebel-eltron-usa.com and click on “Register Your Product.”
Before beginning the registration process, we suggest that you gather the necessary information which will be as follows:
Type, Example: Mini-E 6-2 (from the label that is on the unit)
Number listed after “Nr.” Place of Purchase Purchase Date First & Last Name Email address Physical Address Phone Number Installation Date
If you have any questions concerning the registration process or warranty options, please contact Stiebel Eltron USA directly at
800.582.8423.
4. Appliance description
This thermostatically controlled tankless electric water heater main­tains a constant outlet temperature up to its output limit, regardless of the inlet temperature.
This appliance has been factory-set to 100 °F (38 °C). Once this temperature has been reached, the main control board automat­ically maintains this temperature. The output is matched to the set temperature and prevents this temperature from being exceeded.
The appliance heats the water directly at the draw-off point as soon as the tap is opened. Short pipe runs ensure that energy and water losses are minimal.
The DHW output temperature depends on the cold water tempera­ture, water heater capacity and the flow rate.
The Advanced Direct Coil soft water areas. This heating system has a low susceptibility to scale build-up. The heating system ensures quick and efficient hot water provided at the point-of-use.
Your qualified contractor can adjust the maximum temperature setting (see 11.4, “Settings”, pg. 13).
You must use the aerator provided with the appliance.
heating system is suitable for hard and
6 | MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
ADJUSTMENT
If you have questions regarding the way you plan to use this device, please call our technical service line at 800.582.8423 (USA and Cana­da).
For service outside the U.S. and Canada, please call us at 413.247.3380. You can also e-mail us at info
413.247.3369.
@
stiebel-eltron-usa.com or fax us at
5. Adjustment
The appliance heating system switches on automatically as soon as you open the tap. The water is heated. The water temperature can be adjusted at the tap:
To increase the temperature
f Reduce the flow rate at the tap.
To reduce the temperature
f Open the tap further or add more cold water.
Following an interruption of the water supply
See 11.3, “Recommissioning”, pg. 13.
6. Cleaning, care and maintenance
f Never use abrasive or corrosive cleaning agents. A damp cloth
is sufficient for cleaning the outside of the appliance.
f Check the taps/valves regularly. Lime-scale deposits can be
removed using commercially available descaling agents.
f Have the electrical safety of the appliance periodically checked
by an electrician.
f Regularly descale or replace the provided aerator(s) (See 8.2,
“Optional accessories”, pg. 8).
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS | 7
SAFETY
INSTALLATION
7. Safety
Only a qualified contractor should carry out installation, commis­sioning, maintenance and repair of the appliance.
7.1 General safety instructions
We guarantee trouble-free function and operational reliability only if original accessories and spare parts intended for the appliance are used.
Material losses:
!
Observe the max. permissible inlet temperature. Higher temperatures may damage the appliance. You can limit the inlet temperature by means of a central thermostatic valve (See 8.2, “Optional accessories”, pg. 8).
Note:
Observe all applicable national, state & local regulations codes, and instructions.
8. Appliance description
8.1 Standard delivery
The following are delivered with the appliance:
- Filter screen in the cold water inlet
-Aerator(s)
- Power cable
8.2 Optional accessories
Mini-E TLC - Thermostatic mixing valve
For ASSE 1070-2004 compliance, use optional Mini-E TLC kit available from Stiebel Eltron.
Visit www.stiebel-eltron-usa.com for more information.
9. Preparations
f Flush the water line thoroughly.
Water installation
A safety valve is not required by Stiebel Eltron, but one may be required by local plumbing code. Check the codes before installation.
8 | MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
INSTALLATION
Note:
Installing the supplied aerator(s) is required, and provides optimum water flow.
10. Installation
10.1 Installation site
Do not install in an area that can be exposed to temperatures below 41 °F (5 °C).
Ensure access to the opening screws on both sides of the cover so that they can be easily removed if service is necessary.
The appliance is suitable for an undersink or oversink installation. It can be installed with water connections at the top or at the bottom.
DANGER: Electrocution
The adjustment screw for setting the temperature is live, and the IP25 protection is only given when the appliance back panel is fitted.
10.2 Installation configuration
10.2.1 Typical installation
1 Tee 2 Shut-off valve 3 Aerator
3
1
2
26_02_05_0093
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS | 9
INSTALLATION
10.2.2 Appliance installation
Note:
f Mount the appliance on the wall. The wall must have a sufficient load-bearing capacity for the weight of the device.
d
1
1 Knockout for hard-wiring
f Using pliers, break out the knock-out for the power cable in the
c
e
26_02_05_0083
1 Undo the cover screws by two turns. 2 Undo the snap fastener using a screwdriver. 3 Remove the appliance cover with the heater towards the front.
10 | MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
appliance cover. Correct the contours with a file if necessary.
f Use the appliance back panel as a drilling template.f Secure the appliance back panel to the wall with suitable plugs
and screws.
26_02_05_0084
INSTALLATION
d
e
c
1 Hook in the appliance cover 2 Click the heater into place using the snap fastener. 3 Secure the appliance cover with the cover fastening screws.
Faucet installation
f Install the connections to the faucet. For this, also observe the
faucet operating and installation instructions.
Material losses:
!
f When making the connections, counter the torque on
the appliance using a 14 mm wrench.
26_02_05_0085
10.3 Connecting the power supply
DANGER: Electrocution
Carry out all electrical connection and installation work in accordance with national, state & local regulations.
DANGER: Electrocution
Ensure that the appliance is grounded. Ensure the appliance can be separated from the power supply by a circuit breaker that disconnects all poles.
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS | 11
COMMISSIONING
DANGER: Electrocution
The appliances are delivered with a power cable to be connected to a permanent power supply. Ensure that the proper wire gauge is installed with the appliance in accordance with the minimum recommended wire size in section 15.4, “Data table”, pg. 20.
Material losses:
!
When making the connection to a standard wall socket, ensure that the socket is freely accessible to be easily disconnected in case of an issue.
Material losses:
!
Take note of the product label. The specified voltage must match the mains voltage.
f If the appliance is to be hardwired, connect the power cable as
shown in the wiring diagram (see 15.2, “Wiring diagram”, pg.
18).
11. Commissioning
11.1 Initial start-up
26_02_05_0087
f Before you activate the power supply, fill the appliance with
water first to avoid dry firing the heating element.
f Check for leaks.f Activate the power supply.f Run the tap.f Check the function of the appliance.
11.2 Appliance handover
f Explain the appliance function to users and familiarize them
with its operation.
f Make users aware of potential dangers, especially the risk of
scalding.
f Hand over these instructions.
12 | MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
COMMISSIONING
11.3 Recommissioning
Material losses:
!
Following an interruption of the water supply, recommis­sion the appliance by carrying out the following steps in order to prevent irreparable damage to the Advanced Direct Coil™ heating system.
f Deactivate the power supply.f Follow the steps in section 11.1, “Initial start-up”, pg. 12.
11.4 Settings
You can alter the maximum temperature setting using the potenti­ometer on the interior of the appliance.
DANGER: Electrocution
The temperature may only be adjusted if the appliance is isolated from the power supply.
DANGER: Electrocution
The adjusting screw for setting the temperature is live when the power supply is active.
ENGLISH
26_02_05_0076_
f Remove the appliance cover.
WWW.STIEBEL-ELTRON-USA.COM MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS | 13
SHUTTING DOWN
Setting the maximum temperature
Factory setting: 100 °F (38 °C)
86°F / 30°C
100°F / 38°C
122°F / 50°C
Do not adjust the temperature unless the power supply has been deactivated/disconnected.
f Using a flat screwdriver, set the potentiometer to the maximum
required temperature.
f Re-fit the appliance cover.
12. Shutting down
f Turn off the circuit breaker connected to the appliance.f Drain the appliance (See , “Draining the appliance”, pg. 16).
13. Troubleshooting
Problem Cause Remedy
The appliance will not start despite the tap being fully open.
D0000042035
No power to the appliance Check the fuses/circuit
The flow rate is too low. Increase the flow rate.
The filter screen in the cold water line is blocked.
The heater is faulty.
The safety pressure cutout has activated.
breaker.
Clean aerator installed at faucet
Clean the filter screen after shutting off the cold water inlet line.
Check the resistance of the heating system and replace the appliance if required. Contact Stiebel Eltron for additional troubleshooting
Remedy the cause of the fault. Isolate the appliance from the power supply and depressurize the water line. Reset the safety pressure cutout.
14 | MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
TROUBLESHOOTING
Problem Cause Remedy
The required temperature is not being reached.
The appliance is operating
The maximum tempera­ture set inside the appli­ance is too low.
beyond its output limit.
Have your qualified install­er adjust the maximum temperature.
Reduce the flow rate.
If you cannot remedy the fault, notify your qualified contractor. To facilitate and speed up your request, provide the serial number from the type plate (000000-0000-000000).
Mini-E
Nr.: 000000-0000-000000
LED indicators
321
1 Illuminates red in case of a fault 2 Illuminates yellow during heating operation or flashes yellow
when demand is exceeding capacity
3 Flashes green if the main control board is receiving power
ENGLISH
26_02_05_0082_
WWW.STIEBEL-ELTRON-USA.COM MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS | 15
MAINTENANCE
The safety pressure cutout
DANGER: Electrocution
Do not attempt to reset the safety pressure cutout of this water heater unless power to the unit has been completely shut off at the circuit breakers.
c
1 Safety pressure cutout for Mini-E If the safety pressure cutout is consistently tripping, there may be
an issue with the hot water supply or the appliance. Contact your installation contractor to troubleshoot the appliance.
14. Maintenance
DANGER: Electrocution
Before any work on the appliance, disconnect the power supply.
Draining the appliance
DANGER: Scalding
Hot water may escape during the draining process.
If the appliance needs to be drained for maintenance or to protect the appliance when there is a risk of frost, proceed as follows:
f Close the shut-off valve in the cold water inlet line.f Open the draw-off valve.f Undo the water connections on the appliance.
D0000039769
Note:
The filter screen should be checked regularly for debris and scale, and cleaned or replaced if necessary. Always shut off power and water to the unit prior to removing the filter screen.
16 | MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
SPECIFICATION
Cleaning the filter screen
You can clean the filter screen after removing the cold water supply connection.
CH
26_02_05_0065_
Checking the ground conductor
f Check the ground conductor on the appliance connection cable.
Appliance storage
f Store the dismantled appliance in a room free from the risk of
freezing, as water residues remaining inside the appliance can freeze and cause damage.
15. Specification
15.1 Dimensions and connections
7½˝ (190 mm)
4¾˝ (120 mm)
1
˝
1
/
8
5
˝
5
/
8
(143 mm)
(28 mm)
c06
3
/
16
(4,8 mm)
3
1
/
16
c01
˝
3¾˝ (95 mm)
˝ (30 mm)
6½˝
(165 mm)
3¼˝ (82 mm)
b02 Electric cable entry 1 b03 Electric cable entry 2 c01 Cold water inlet ⅜˝ G male* c06 DHW outlet ⅜˝ G male*
*This is a parallel thread for connec tion to a ⅜ O.D. flex connec tor or ⅜ compression fitting
b03
b02
¾˝ (20 mm)
Mini™-E
ENGLISH
D0000018336
WWW.STIEBEL-ELTRON-USA.COM MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS | 17
SPECIFICATION
15.2 Wiring diagram
15.2.1 Mini-E 2-1, Mini-E 2.5-1, Mini-E 3-1 & Mini-E 3.5-1 ~ 110–120 V
-
3
V >
2
p >
1
L N
LN
1 Safety pressure cutout 2 Flow activation switch 3 Main control board with outlet temperature sensor
15.2.2 Mini-E 4-2 and Mini-E 6-2 ~ 220–240 V
3
2
1
-
V >
p >
L L
LL
1 Safety pressure cutout 2 Flow activation switch
D0000035308
3 Main control board with outlet temperature sensor
85_02_05_0001
18 | MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
SPECIFICATION
Material losses:
!
f In an installation with a permanent power supply,
connect the power cable according to the designations on the socket terminals.
15.3 Temperature rise table
Temp. rise above incoming water temp. (°F) Temp. rise above incoming water temp. (°C)
GPM l/min
Unit Heating Capacity 0.32 0.42 0.48 0.53 0.69 0.85 1.06 1.14 1.2 1.6 1.8 2.0 2.6 3.2 4.0 4.3
Mini-E 2-1* 1.8 kW @ 110–120 V 39 - - - - - - - 22 - - - - - - - Mini-E 2.5-1 2.4 kW @ 110–120 V 51 39 34 30 24 19 15 14 28 22 19 17 13 11 8 8 Mini-E 3-1 3.0 kW @ 110–120 V 64 49 43 38 30 24 19 18 36 27 24 21 17 13 11 10 Mini-E 3.5-1 3.5 kW @ 110–120 V 75 57 50 45 35 28 22 21 42 32 28 25 19 16 12 12 Mini-E 4-2
3.5 kW @ 220–240 V 75 57 50 45 35 28 22 21 42 32 28 25 19 16 12 12 Mini-E 6-2
5.7 kW @ 220–240 V - - 81 73 56 45 36 34 - - 45 41 31 25 20 19
*Mini-E 2-1 is internally restricted to 0.40 GPM (1.5 l/min) Note: The output of the heating element depends on the supplied voltage. Fluctuating or varying voltages may cause the appliance to deliver hot water at different values
than the ones in the above table.
WWW.STIEBEL-ELTRON-USA.COM MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS | 19
2.6 kW @ 208 V 55 42 37 33 25 20 16 15 31 23 21 18 14 11 9 8
4.3 kW @ 208 V - - 61 55 42 34 27 25 - - 34 31 23 19 15 14
ENGLISH
SPECIFICATION
15.4 Data table
Mini™-E 2-1 Mini™-E 2.5-1 Mini™-E 3-1 Mini™-E 3.5-1 Mini™-E 4-2 Mini™-E 6-2
236011 236135 236010 236136 236009 236008 Electrical data Phase 1 - 50/60 Hz
1
Voltage Wattage 1.8 kW 2.4 kW 3.0 kW 3.5 kW 3.5 kW 2.6 kW 5.7 kW 4.3 kW Amperage draw 15 A 20 A 25 A 29 A 15 A 13 A 24 A 21 A Min. recommended circuit breaker size215 A 20 A 25 A 30 A 15 A 25 A Min. recommended wire size3 (copper) 14 AWG 12 AWG 10 AWG 10 AWG 14 AWG 10 AWG Connections Water connection ⅜ O.D. flex connector or ⅜ compression fitting Application limits Max. permissible pressure 150 psi (10 bar) Max. inlet temperature for reheating 122 °F (50 °C) Temperature & Flow Values Max. permissible inlet temperature 140 °F (60 °C) Temperature setting range, DHW 86–122 °F (30–50 °C) Minimum water flow to activate unit 0.21 gpm (0.8 l/min) 0.3 gpm (1.15 l/min) 0.3 gpm (1.15 l/min) 0.3 gpm (1.15 l/min) 0.3 gpm (1.15 l/min) 0.47 gpm (1.8 l/min) Pressure drop at activation flow rate 7.2 psi (0.5 bar) 7. 2 psi (0.5 bar) 7. 2 psi (0.5 bar) 7.2 psi (0.5 bar) 8.7 psi (0.6 bar) 10.2 psi (0.7 bar)
*
Mini-E 2-1 is internally restricted to 0.4 gpm (1.5 l/min).
1
Nominal mains voltage is 110–120 V and 220–240 V.
2
This is our recommendation for over-current protection sized at 100% of load. Check local codes for compliance if necessary. Tankless water heaters are considered a
non-continuous load.
3
AWG copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
110–120 V 110–120 V 110–120 V 110–120 V 220–240 V 208 V 220–240 V 208 V
20 | MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS WWW.STIEBEL-ELTRON-USA.COM
SPECIFICATION
Mini™-E 2-1 Mini™-E 2.5-1 Mini™-E 3-1 Mini™-E 3.5-1 Mini™-E 4-2 Mini™-E 6-2
Miscellaneous IP rating IP25 Insulating block Plastic Heating element Nichrome wire Color White Included aerator(s) that must be
installed Dimensions Height 6½ (165 mm) Width 7½ (190 mm) Depth 3¼ (82 mm) Weights Weight 3.3 lbs (1.5 kg)
4
If plumbing Mini-E 6-2 to a single sink, substitute the included single 1.0 gpm (3.8 l/min) aerator/flow reducer.
0.35 gpm (1.3 l/min) 0.5 gpm (1.9 l/min) 0.5 gpm (1.9 l/min) 0.5 gpm (1.9 l/min) 0.66 gpm (2.5 l/min) 2 x 0.5 gpm4 (1.9 l/min) 1 x 1.0 gpm (3.8 l/min)
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM MINI™-E SERIES TANKLESS ELECTRIC WATER HEATERS | 21
SPARE PARTS LIST
16. Spare parts list
5
6
2
4
No. No. Spare par t Mini™-E 2-1
Mini™-E 2.5-1
-E 3-1
Mini Mini™-E 3.5-1 Mini™-E 4-2 Mini™-E 6-2
1 Front cover 271013 2 Rear housing 271011 3 Filter screen 272777 4 Plumbing connection 272757 5 NTC temperature sensor 295276 6 Sensor bracket 293818 7 O-rings 083043