Stiebel Eltron 230628 Instruction Manual

Page 1
Commercial Application
800.582.8423
www.stiebel-eltron-usa.com
Point-of-Use Tankless Electric
Mini™ | DHC | Mini™-E | DHC-E | Tempra
®
The Finest Tankless Electric
Water Heaters Available!
Tested and cer tified by
WQA again st NSF/ANSI 372
for lead fre e compliance.
› On-demand, continuous,
unlimited hot water
› No venting required
›Exclusivedesignpreventsdryring
› Saves space
›99%efciency&no standby losses
Page 2
Tankless electric water heaters for point-of-use
Superior, Reliable & Energy Saving Performance |
electric water heaters temperature sensors. Electronic models feed their readings into proprietary microprocessor controls. Auto-modulation ensures that heating elements are engaged in stages, achieving the water temperature desired, with the lowest possible energy usage. Both the input and output water temperature and the flow rate are continually monitored. This smart Electronic Temperature Control microprocessor technology ensures steady output at the set point temperature even if flow rates vary up or down. Tankless electric water heaters from other manufacturers don’t maintain steady temperature if the incoming flow rate varies.
All Stiebel Eltron tankless
have flow and
Best Warranty in the Industry | Stiebel
Eltron has an enviable track record of engineering excellence and product quality. The three-year parts warranty is unique in the industry. You can depend on a Stiebel Eltron tankless electric water heater
for many years to come.
Superior Engineering in Every Way |
Electronic models are completely silent in operation. Mechanical models are virtually silent. All models feature an exclusive design that prevents failure from dry-firing, plus manual safety high­limit cutoffs.
Simple Design of Plumbing System |
There is no need for a T & P valve, drain or mixing valve. The design of the hot water plumbing system is very simple and straightforward.
Sleek Design Fits in Anywhere | Due
to their compact dimensions, these water heaters may be installed close to draw-off points to minimize piping runs and also in areas where larger devices will not fit. The attractive housings may be left unconcealed in many applications.
Seismic Proof Construction | These
tankless water heaters are not subject to seismic code. There is no need for preventative construction, as required with bulky water storage heating systems.
No Venting Required | The units are
electric and require no venting. This allows for installation possibilities not possible for gas units.
Code Compliance Made Easy | A water
temperature required by code can simply be dialed in on all electronic models. The accuracy of the water temperature is guaranteed by sophisticated electronics.
®
The DHC-E and Tempra 140 °F (60 °C) water when health codes call for it. They can also be set internally to limit output temperature to a maximum of 109 °F (43 °C) where scalding water is a hazard. Mini
have optional externally attached mixing
can supply up to
-E and DHC-E models
valve assemblies for installations where UPC code compliance is a necessity. No need to worry about mixing valves that go out of adjustment and wear out. At the same time, when lower, non-scalding temperatures are needed, the advanced
®
electronics of the DHC-E / Tempra
ensure
what you set is what you get.
Electronic Model Temperature Control |
The Mini-E is factory-set internally to deliver maximum 100 °F (38 °C) water temperature. It can be field set or custom ordered to deliver
®
a different water temperature. Tempra DHC-E are adjusted on the front cover to set output water temperature between 68 to 140 °F (20 – 60 °C).
and
Page 3
These are the ones that work.
Stiebel Eltron Mini™, DHC, DHC-E &
Tempra
®
Tankless Electric Water
Heaters deliver instant hot water,
and can eliminate time waiting for hot water, preserve precious water resources, and save energy.
7 years leakage/ 3 years parts. Complete warranty online.
Mini
Best applications single handwashing sink single handwashing sink single sink multiple handwashing sinks
Mechanical or electronic Mechanical Electronic Mechanical Electronic Electronic
Installation orientations below or above sink
Voltages available 120/240
Output range for model 1.8 – 5.7 kW 1.8 – 5.7 kW 3 – 9.6 kW 7.2 – 12 kW 12 – 36 kW
Power draw for model 14.6 – 2 9 A 14.6 – 2 9 A 14 – 4 0 A 3 0 – 50 A 50 – 150 A
Activation flow rate
(varies by kW)
Temperature rise range
(approx.)
Temperature selector no yes no yes yes
Width/height/depth 7½ / 6½ / 3¼
water connections point­ing up or down
V 120/240 V 120/240/277 V 240 V 240 V
0.21, 0.40, 0.77 gpm 0.21, 0.30 gpm 0.32, 0.42, 0.47, 0.69,
~30 °F ~30 °F ~30-80 °F ~20-90 °F ~30-90 °F
inches
190 / 165 / 82 cm
Mini™-E DHC DHC-E Tempra
or single high flow sink
below or above sink water connections pointing up or down
7½ / 6½ / 3¼ inches 190 / 165 / 82 cm
below or above sink water connections pointing down
gpm
0.79
77/16 / 143/16 / 41/16 inches
20.0 / 36.0 / 10.4 cm
below or above sink water connections pointing down
0.264 gpm 0.37, 0.50, 0.77 gpm
77/16 / 143/16 / 41/16 inches
20.0 / 36.0 / 10.4 cm
multiple handwashing sinks or single high flow sink
below or above sink water connections pointing down
165/8 / 14½ / 45/
42.0 / 36.9 / 11.7 cm
®
inches
8
Superior Technical Support
Stiebel Eltron's knowledgeable customer support staff
can offer product and sizing recommendations as well
as help with troubleshooting and technical questions.
800.582.8423
Page 4
GPM
2.6 / 1.7 / 1.4
GPM
3.5 / 2.0 / 1.7
GPM
5.4 / 2.6 / 2.0
GPM
GPM
3.4 / 2.2 / 1.9
GPM
4.6 / 2.7 / 2.2
GPM
7.2 / 3.4 / 2.7
GPM
GPM
5.1 / 2.9
GPM
7.0 / 3.4
GPM
8 / 4.1
GPM
GPM
6.4 / 3.6
GPM
8 / 4.2
GPM
8 / 5.1
GPM
GPM
4.3 / 2.8 / 2.4
GPM
5.8 / 3.4 / 2.8
GPM
8 / 4.3 / 3.4
GPM
/ Tempra® 12
Tren d & Plus Min. activation 0.37 GPM
GPM
2.1 / 1.4
GPM
2.9 / 1.7 / 1.4
GPM
4.5 / 2.1 / 1.7
GPM
GPM
1.7
GPM
2.3 / 1.3
GPM
3.6 / 1.7 / 1.3
GPM
GPM
1.3
GPM
1.7 / 1.0
GPM
2.7 / 1.3
GPM
Temp Rise °F
Sizing Guide for Commercial Point-of Use
DHC 8-2
DHC 5-2
DHC 6-2
DHC 9-3
DHC 10-2
DHC 4-3
Temp Rise °F
Sizing Guide for Commercial Point-of Use
Not intended for whole house sizing
Temperature Rise vs. Flow Rate at 240 V
Flow Rate GPM
Temp Rise °F
Tempra® 20
Tempra
®
24
Tempra
®
29
Tempra
®
36
Tempra
®
12
DHC-E 12
Tempra
®
15
10
20
30
40
50
80
90
70
60
0
1.00.5 1.5 2.0 2.5 3.0 3.5 4.0 4.5
5.0 5.5 6.0 6.5 7.0 7.5 8.0
and 208 V
Tempra® 24
Trend & Plus | Min. activation 0.50 GPM
Tempra® 15
Trend & Plus | Min. activation 0.50 GPM
2.0 / 1.4
GPM
2.6 / 1.7 / 1.4
GPM
3.5 / 2.0 / 1.7
GPM
5.4 / 2.6 / 2.0
GPM
Tempra® 20
Trend & Plus | Min. activation 0.50 GPM
2.7 / 1.9 / 1.6
GPM
3.4 / 2.2 / 1.9
GPM
4.6 / 2.7 / 2.2
GPM
7. 2 / 3.4 / 2.7
GPM
Tempra® 29
Trend & Plus | Min. activation 0.77 GPM
4.1 / 2.5
GPM
5.1 / 2.9
GPM
7.0 / 3.4
GPM
8 / 4.1
GPM
Tempra® 36
Trend & Plus | Min. activation 0.77 GPM
5.1 / 3.1
GPM
6.4 / 3.6
GPM
8 / 4.2
GPM
8 / 5.1
GPM
MAX. FLOW RATE
MAX. FLOW RATE
MAX. FLOW RATE
MAX. FLOW RATE
MAX. FLOW RATE
42°F 52°F 62°F 72°F
3.4 / 2.4 / 2.1
GPM
4.3 / 2.8 / 2.4
GPM
5.8 / 3.4 / 2.8
GPM
8 / 4.3 / 3.4
GPM
DHC-E 12
Min. activation 0.264 GPM /
Tempra® 12
Trend & Plus Min. activation 0.37 GPM
MAX. FLOW RATE
1.7 / 1.2
GPM
2.1 / 1.4
GPM
2.9 / 1.7 / 1.4
GPM
4.5 / 2.1 / 1.7
GPM
DHC-E 8/10
@ 9.6 kW | Min. activation 0.264 GPM
MAX. FLOW RATE
1.3
GPM
1.7
GPM
2.3 / 1.3
GPM
3.6 / 1.7 / 1.3
GPM
DHC-E 8/10
@ 7.2 kW | Min. activation 0.264 GPM
MAX. FLOW RATE
1.0
GPM
1.3
GPM
1.7 / 1.0
GPM
2.7 / 1.3
GPM
Sizing Guide for Commercial Point-of Use
Not intended for whole house sizing
POSSIBLE FIX TURE TYPES
POSSIBLE FIX TURE TYPES
POSSIBLE FIX TURE TYPES
POSSIBLE FIX TURE TYPES
POSSIBLE FIX TURE TYPES
POSSIBLE FIX TURE TYPES
POSSIBLE FIX TURE TYPES
POSSIBLE FIX TURE TYPES
42°F
52°F
72°F
62°F
The Right Size for the Application
COMMERCIAL POINT-OF-USE SIZING GUIDES
42°F 52°F 62°F 72°F
Mini
/
Mini™-E 2-1
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
Mini
/
Mini™-E 2.5-1
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
Mini
/
Mini™-E 3-1
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
Mini
Mini
DHC 3-1
/
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
/
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
DHC 3-2
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
DHC 4-2
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
Mini™-E 3.5-1
Mini™-E 6-2
| Min. activation 0.32 GPM
| Min. activation 0.32 GPM
| Min. activation 0.42 GPM
| Min. activation 0.42 GPM
MAX. FLOW RATE
| Min. activation 0.42 GPM
POSSIBLE FIX TURE TYPES
| Min. activation 0.47 GPM
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
| Min. activation 0.69 GPM
| Min. activation 0.79 GPM
| Min. activation 0.79 GPM
| Min. activation 0.21 GPM | Internally restricted to 0.32 / 0.40 GPM
GPM
0.26
0.32
| Min. activation 0.40 / 0.30 GPM
GPM
0.34
0.43
Mini-E 2.5-1 onl y
| Min. activation 0.40 / 0.30 GPM
GPM
0.43
| Min. activation 0.77 / 0.48 GPM
0.54
OR
Mini
GPM
0.50
GPM
0.81
1.02
/
Mini™-E 4-2
0.63
GPM
0.43
GPM
0.47
GPM
0.54
GPM
0.64
GPM
0.68
GPM
0.85
GPM
1.02
0.54
0.59
0.68
0.81
0.86
1.08
1.29
GPM
1.28
1.62 / 0.90
GPM
1.37
1.73 / 0.96
GPM
0.32 / 0.40
GPM
0.59
GPM
0.73
| Min. activation 0.40 / 0.30 GPM
GPM
0.85
GPM
1.39
GPM
0.32 / 0.40
GPM
0.91
GPM
1.14
GPM
1.33
GPM
2.16
GPM
0.73
GPM
0.81
GPM
0.93
GPM
1.10
GPM
1.17
GPM
1.14
GPM
1.25
GPM
1.44
GPM
1.71
GPM
1.82
GPM
1.46
GPM
1.76
GPM
2.2 / 1.06
GPM
2.34 / 1.13
GPM
2.28
GPM
2.73 / 1.02
GPM
3.42 / 1.28
GPM
3.64 / 1.37
GPM
GPM
GPM
GPM
Mini-E 6-2 1 or 2 sinks
GPM
GPM
GPM
GPM
GPM
GPM
GPM
GPM
GPM
GPM
These guides show possible point-of-use fixture or fixtures for use with each model and size. They are not intended for whole house sizing. Use actual achievable flow rates to determine if a particular model and size will deliver the temperature and flow rate required for the installed fixture.
FIXTURES & FLOW RATES
SHOWING POSSIBLE MODEL SUITABIL ITY
SINGLE LAV SINK
(Range 0.5-1.5)
MULTIPLE SINKS
Number varies
SHOWER
(Range 1.0-2.5)
TEMP. FOR MAX. FLOW RATE CA LCUL ATIO N
90°F
110°F
42°F
52°F
KITCHEN SINK
(Range 1.0-2.2)
UTILITY/JANITOR’S SINK
(Range 1.0-2.2)
Mini
120°F
120°F
Temperature Rise vs. Flow Rate at Max. Rated Voltage
90
0.3
0.48
80
70
0.4
60
0.21
50
40
30
2-1
Mini
0.32
Mini-E
0.40
0.5
0.66
0.5
20
10
0
DHC
Temperature Rise vs. Flow Rate at Maximum Rated Voltage
90
80
70
60
50
40
0.69
30
20
10
0
0.79
0.750.5 1.0 1.25 1.5 1.75 2.0
62°F
72°F
Mini-E activation
Mini
activation
0.77
0.750.25 0.5 1.0 1.25 1.5 1.75 2.0
Aerator / restrictor
1.0
Flow Rate GPM
Flow Rate GPM
DHC-E 8/10
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
DHC-E 8/10
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
DHC-E 12
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
Tempra® 15
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
Tempra® 20
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
Tempra® 24
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
Tempra® 29
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
Tempra® 36
MAX. FLOW RATE
POSSIBLE FIX TURE TYPES
6-2
3.5-1
& 4-2
3-1
2.5-1
DHC 10-2
DHC 9-3
DHC 8-2
DHC 6-2
DHC 5-2
DHC 4-3
DHC 4-2
DHC 3-2
DHC 3-1
DHC-E / Tempra® Trend & Plus
Temperature Rise vs. Flow Rate at 240 V and 208 V
Looking for commercial/industrial 3-phase water heaters? Tankless,
Inc. water heaters from Stiebel Eltron are available for demanding commercial, industrial, and safety applications in all common 3-phase voltages and sizes from 12 to 144 kW. Our 3-phase commercial/industrial direct line is 800.TANKLESS
42°F 52°F 62°F 72°F
@ 7.2 kW | Min. activation 0.264 GPM
GPM
1.0
@ 9.6 kW | Min. activation 0.264 GPM
1.3
Min. activation 0.264 GPM /
1.7 / 1.2
Trend & Plus | Min. activation 0.50 GPM
2.0 / 1.4
Trend & Plus | Min. activation 0.50 GPM
2.7 / 1.9 / 1.6
Trend & Plus | Min. activation 0.50 GPM
3.4 / 2.4 / 2.1
Trend & Plus | Min. activation 0.77 GPM
4.1 / 2.5
Trend & Plus | Min. activation 0.77 GPM
5.1 / 3.1
1.3
GPM
1.7
Tempra® 12
GPM
2.1 / 1.4
GPM
2.6 / 1.7 / 1.4
GPM
3.4 / 2.2 / 1.9
GPM
4.3 / 2.8 / 2.4
GPM
5.1 / 2.9
GPM
6.4 / 3.6
GPM
1 .7 / 1.0
GPM
2.3 / 1.3
Trend & Plus Min. activation 0.37 GPM
GPM
2.9 / 1.7 / 1.4
GPM
3.5 / 2.0 / 1.7
GPM
4.6 / 2.7 / 2.2
GPM
5.8 / 3.4 / 2.8
GPM
7.0 / 3.4
GPM
8 / 4.2
GPM
2.7 / 1.3
GPM
3.6 / 1.7 / 1.3
GPM
4.5 / 2.1 / 1.7
GPM
5.4 / 2.6 / 2.0
GPM
7.2 / 3.4 / 2.7
GPM
8 / 4.3 / 3.4
GPM
8 / 4.1
GPM
8 / 5.1
GPM
GPM
GPM
GPM
GPM
GPM
GPM
GPM
DHC-E 8/10
@
Stage 2
240V
Stage 1 @ 240V
@
208V
Stage 2
@
208V
Stage 1
Page 5
Engineering & Manufacturing Excellence Since 1924
Variable Flow
Mechanical models: Thermostatic models :
Mini 2-1 231045 Mini-E 2-1 236011
Mini 2.5-1 232098 Mini-E 2.5-1 236135
Mini 3-1 220816 Mini-E 3-1 236010
Mini 3.5-1 232099 Mini-E 3.5-1 236136
Mini 4-2 222039 Mini-E 4-2 236009
Mini 6-2 220817 Mini-E 6-2 236008
Phase - 50/60 Hz
1
Voltage
1
120 V 120 V 120 V 120 V 240 V or 208 V 240 V or 208 V
Wattage
1.8 kW 2.4 kW 3.0 kW 3.5 kW 3.5 kW 2.6 kW 5.7 kW 4.3 kW
Amperage draw
15 A 20 A 25 A 29 A 15 A 13 A 24 A 21 A
Min. recommended circuit breaker size
2
15 A (SP) 20 A (SP) 25 A (SP) 30 A (SP) 15 A (DP) 25 A (DP)
Min. recommended wire size
3
(copper)
14/2 AWG 12/2 AWG 10/2 AWG 10/2 AWG 14/2 AWG 10/2 AWG
Min. fl ow to activate
Mechanical units
0.21 gpm (0.8 l/min) 0.40 gpm (1.5 l/min) 0.40 gpm (1.5 l/min) 0.40 gpm (1.5 l/min) 0.40 gpm (1.5 l/min) 0.77 gpm (2.9 l/min)
Thermostatic units
0.21 gpm (0.8 l/min) 0.30 gpm (1.15 l/min) 0.30 gpm (1.15 l/min) 0.36 gpm (1.35 l/min) 0.30 gpm (1.15 l/min) 0.48 gpm (1.8 l/min)
Water temp. range Electronic units are adjustable from 86122 °F (30–50 °C)
Energy Factor (EF)
(Mechanical / Thermostatic)
0.98 / 0.97 (UEF) 1.0 / 0.99 0.99 / 0.99
0.99 / 0.99 0.99 / 1.0 0.99 / 1.0
Weight 3.44 lb (1.56 kg)
Dimensions
Width 7 ½˝ (190 mm) x Height 6½˝ (165 mm) x Depth 3¼˝ (82 mm)
Water volume in unit 0.026 gal (0.1 l) Working pressure 150
psi (10 bar)
Tested to pressure 300 psi (20 bar)
Water connections
4
3
/8˝ O.D. flexible braided stainless steel hose connectors
Mini 2-1 is internally restricted to 0.32 gpm (1.2 l/min). Mini-E 2-1 is internally restricted to 0.40 gpm (1.5 l/min). All Mini
models ship with appropriately sized pressure compensating fl ow-reducer/aerators that must be installed.
1
Nominal mains voltage is 110120 V and 220 240 V.
2
This is our recommendation for overcurrent protection sized at 100% of load. Check local codes for compliance if necessary.
Tankless water heaters are considered a non-continuous load.
3
Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
4
Mechanical units suitable for supply with cold water only. Thermostatic units can accept inlet water of 105 °F.
Tested and cer tified by WQA against NSF/ANSI 372 for lead free compliance.
Certified to ANSI/UL Std. 499
Conforms to CAN/CSA E335-1 & E335-2-35Technical Data
Take The Cover Off | Whether it is
our solid copper or our Advanced
Direct Coil happy to have you take the cover off. We've done our homework for over 90 years. As an international leader in the tankless electric water heating industry, Stiebel Eltron is proud to
heating system, we're
Tempra® Trend & Tempra® Plus with Advanced Flow Control™ | Advanced
Flow Control 102004037966 A1 and other patents, is exclusive to Tempra manufacturer of tankless electric water heaters has anything like it. Advanced Flow Control how great the demand is for hot water, even if it is temporarily greater than capacity, Advanced Flow Control maintain delivery at the desired temperature.
, invented by Stiebel Eltron and awarded German patent DE
ensures constant temperature output at the set point. No matter
automatically reduces water flow slightly to
have invented and pioneered tankless water heating technology. Our German engineering and manufacturing tradition of excellence means that you
Safety pressure cut-out
Advanced Direct Coil Heating Technology
can depend on the performance of all our products for many years to come.
Advanced Direct Coil™ Heating System in Mini™ and Mini™-E | Mini
and Mini heating system. The ultra-reliable Mini than their small size might lead you to think.
Tempra® 15, 20 or 24 Plus shown.
Tempra® 12 has one heating element, Tempra® 29 & 36 have three heating elements.
Hinged cover
Safety thermal cut-off
Temperature sensor
Solid copper heating element
-E feature our Direct Coil™
and Mini™-E are more powerful
Steady Temperature
steady temperature if flow varies. Stiebel Eltron electronically-controlled models deliver consistent comfort — every time — all the time.
Our exclusive Electronic Temperature Control compensates for flow rate fluctuations to maintain constant temperature output. Tankless electric water heaters from other manufacturers do not maintain
Wiring block
Hot water
connection
Cold water connection
Wiring block
Flow sensor
Temperature sensor
Electronic Control module
Advanced Flow Control™
(Plus models)
Flow switch
Safety
thermal
cut-off
Solid copper
heating element
Electronic
Control
module
Flow
sensor
Temperature
sensor
Cold water
connection
Hot water
connection
Advanced Flow Control™ in Tempra® Plus was invented by Stiebel Eltron. No other manufacturer of tankless electric has anything like it.
®
Plus. No other
Mini™ shown.
Mini™-E (shown behind Mini™) has an electronic control board.
Electronic Control module (Mini
-E)
DHC-E 8/10, DHC-E 12
DHC-E 8/10 has a selectable power output of 7.2 or 9.6 kW.
Page 6
Mini™ / Mini™-E
(SP)
(SP)
(SP)
(SP)
(DP)
(DP)
UEF)
Tested and cer tified by WQA against NSF/ANSI 372 for lead free compliance.
Certified to ANSI/UL Std. 499
Conforms to CAN/CSA E335-1 & E335-2-35Technical Data
& SP
Tested and certified by WQA against NSF/ANSI 372 for lead free compliance.
Certified to ANSI/UL Std. 499 Conforms to CAN/CSA E335-1 & E335-2-35
Technical Data
Mechanical models: Thermostatic models :
Phase - 50/60 Hz
1
Voltage
Wattage
Amperage draw
Min. recommended circuit breaker size
Min. recommended wire size
3
(copper)
Mini™ 2-1 231045 Mini™-E 2-1 236011
Mini™ 2.5-1 232098 Mini™-E 2.5-1 236135
Mini™ 3-1 220816 Mini™-E 3-1 236010
Mini™ 3.5-1 232099 Mini™-E 3.5-1 236136
Mini™ 4-2 222039 Mini™-E 4-2 236009
1
120 V 120 V 120 V 120 V 240 V or 208 V 240 V or 208 V
1.8 kW 2.4 kW 3.0 kW 3.5 kW 3.5 kW 2.6 kW 5.7 kW 4.3 kW 15 A 20 A 25 A 29 A 15 A 13 A 24 A 21 A 15 A
2
20 A
25 A
30 A
15 A
14/2 AWG 12/2 AWG 10/2 AWG 10/2 AWG 14/2 AWG 10/2 AWG
Min. fl ow to activate
Mechanical units Thermostatic units
0.21 gpm (0.8 l/min) 0.40 gpm (1.5 l/min) 0.40 gpm (1.5 l/min) 0.40 gpm (1.5 l/min) 0.40 gpm (1.5 l/min) 0.77 gpm (2.9 l/min)
0.21 gpm (0.8 l/min) 0.30 gpm (1.15 l/min) 0.30 gpm (1.15 l/min) 0.36 gpm (1.35 l/min) 0.30 gpm (1.15 l/min) 0.48 gpm (1.8 l/min)
Water temp. range Electronic units are adjustable from 86–122 °F (30–50 °C)
Energy Factor (EF)
(Mechanical / Thermostatic)
0.98 / 0.97 (
1.0 / 0.99 0.99 / 0.99
0.99 / 0.99 0.99 / 1.0 0.99 / 1.0
Weight 3.44 lb (1.56 kg)
Dimensions
Width 7 ½˝ (190 mm) x Height 6½˝ (165 mm) x Depth 3¼˝ (82 mm)
Water volume in unit 0.026 gal (0.1 l) Working pressure 150
psi (10 bar)
Tested to pressure 300 psi (20 bar)
4
Water connections
Mini™ 2-1 is internally restricted to 0.32 gpm (1.2 l/min). Mini™-E 2-1 is internally restricted to 0.40 gpm (1.5 l/min).
All Mini
models ship with appropriately sized pressure compensating fl ow-reducer/aerators that must be installed.
1
Nominal mains voltage is 110–120 V and 220 –240 V.
2
This is our recommendation for overcurrent protection sized at 100% of load. Check local codes for compliance if necessary.
Tankless water heaters are considered a non-continuous load.
3
Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
4
Mechanical units suitable for supply with cold water only. Thermostatic units can accept inlet water of 105 °F.
3
/8˝ O.D. flexible braided stainless steel hose connectors
Mini™ 6-2 220817 Mini™-E 6-2 236008
25 A
DHC
Model DHC 3-1 DHC 3-2 DHC 4-2 DHC 4-3 D HC 5 -2 DHC 6-2 DHC 8-2 DHC 9-3 DHC 10 -2
Item no. 074050 074052 074053 074051 074054 074424 074055 232204 074056
- 50/60 Hz 1
Phase Voltage 120 V 240 V 208 V 240 V 208 V 277 V 240 V 208 V 240 V 208 V 240 V 208 V 277 V 240 V 208 V Wattage 3.0 kW 3.3 kW 2.5 kW 3.8 kW 2.9 kW 4.5 kW 4.8 kW 3.6 kW 6.0 kW 4.5 kW 7.2 kW 5.4 kW 9.0 kW 9.6 kW 7. 2 kW Amperage 25 a 14 a 12 a 16 a 14 a 17 a 20 a 18 a 25 a 22 a 30 a 26 a 32.5 a 40 a 35 a
Min. recommended circuit breaker size
Min. recommended wire size 210/2 AWG 14/2 AWG 12/2 AWG 14/2 AWG 12/2 AWG 12/2 AWG 10/2 AWG 10/2 AWG 8/2 AWG 8/2 AWG
Minimum water flow to activate unit
Weight 4.6 lb (2.1 kg) 5.3 lb (2.4 kg) 5.3 lb (2.4 kg) 4.6 lb (2.1 kg) 4.6 lb (2.1 kg) 4.6 lb (2.1 kg) 5.3 lb (2.4 kg) 5.3 lb (2.4 kg) 5.3 lb (2.4 kg)
Dimensions
Nominal water volume 0.13 gal (0.5 l) Working pressure 150 psi (10 bar) Tested to pressure 300 psi (20 bar)
Water connections
1
3
25 a 15 a 15 a 20 a 15 a 20 a 20 a 20 a 25 a 25 a 30 a 30 a 35 a 40 a 35 a
0.32 gpm (1.2 l/min)
Width 7
½� NPT
0.32 gpm (1.2 l/min)
7
/8� (20.0 cm) x Height 143/16� (36.0 cm) x Depth 41/8� (10.4 cm)
0.42 gpm (1.6 l/min)
0.42 gpm (1.6 l/min)
0.42 gpm (1.6 l/min)
0.47 gp m (1.8 l/min)
0.69 gpm (2.6 l/min)
0.79 gpm (3.0 l/min)
0.79 gpm (3.0 l/min)
DHC 3-1, 3-2, 4-2 ship with a 0.5 gpm (1.9 l/min) pressure compensating fl ow-reducer/aerator that must be installed.
1
This is our recommendation for overcurrent protection sized at 100% of load (DP for 240/208/277 V
for 120 V models).
Check local codes for compliance if necessary. Tankless water heaters are considered a non-continuous load.
2
Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
3
Suitable for supply with cold water only.
Page 7
DHC-E
V
V
W
W
W
DP
GPM
GPM
GPM
GPM
GPM
Water connections ½NPT
Tested and cer tified by WQA against NSF/ANSI 37 2 for lead free comp liance.
Certified to ANSI/UL S td. 499 Conforms to CAN/CS A E335-1 & E335-2-35
Technical Data
aWG
aWG
aWG
aWG
aWG
aWG
GPM
GPM
GPM
GPM
Tested and certified by WQA against NSF/ANSI 372 for lead free compliance.
Certified to ANSI/UL Std. 499 Conforms to CAN/CSA Std. C22.2 No.88
Technical Data
Model Item Number DHC-E 8/10* 224201 DHC-E 12 230628
Phase single 50/60
Voltage 240 V or 208 Wattage 7.2 /9.6 kW 5.4/ 7.2 k Amperage 30/40 A 26/35 A 50 A 44 A
1
Min. recommended circuit breaker
Min. recommended wire size
Maximum temperature increase above ambient water temp.
2
(copper)
@
0.75
@
1.00
@
1.50
@
2.25
@
3.00
30/40 A 30/35 A 50 A 50 A
(
)
10 AWG/8 AWG 8 AWG 66/87 °F 49/66 °F 92 °F 82 °F 49/66 °F 37/49 °F 82 °F 61 °F 33/44 °F 25/33 °F 54 °F 41 °F
- - 36 °F 27 °F
- - 27 °F 20 °F
Min. water flow to activate unit 0.264 gpm (1.0 l/min) Max. inlet water temperature 131 Weight 5.9 Nominal water volume 0.13
1
Dimensions
Width 7
/8
(20.0
Working pressure 150 Tested to pressure 300
Hz single 50/60 Hz
°F (55 °C)
lb (2.7 kg)
gal (0.5 l)
3
16
cm) x Height 14
psi (10 bar) psi (20 bar)
(36.0
/
240 V or 208 12 k
cm) x Depth 4
9 k
1
/8
(11.0
cm)
17 West St., W Hatfield, MA 01088
800.582.8423 | 413.247.3380 | FAX 413.247.3369
info@stiebel-eltron-usa.com | www.stiebel-eltron-usa.com
Printed on chlorine-free paper using soy-based inks. #25-6.2019
Mini / DHC / DHC-E: Conforms to ANSI/UL Std. 499 Certified to CAN/CSA E335-1 & E335-2-35 Tempra®: Conforms to ANSI/UL Std. 499 Certified to CAN/CSA Std. C 22.2 No.88
Tested and certified by WQA against NSF/ANSI 372 for lead free compliance.
*DHC-E 8/10 is a single unit that is switchable at installation via jumper for output at 7.2 kW (Stage 1) or 9.6 kW (Stage 2).
1
Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load.
2
Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
These are our recommendations. Check local codes for compliance if necessary.
®
Tempra
Tempra® Model
Item Number
Phase single 50/60 Hz single6 50/60 Hz single6 50/60 Hz single6 50/60 Hz single6 50/60 Hz single6 50/60 Hz
Voltage 240 V or 208 V 240 V or 208 V 240 V or 208 V 240 V or 208 V 240 V or 208 V 240 V or 208 V Wattage 12 kW 9 kW 14.4 kW 10.8 kW 19.2 kW 14.4 kW 24 kW 18 kW 28.8 kW 21.6 kW 36 kW 27 kW Amperage draw 50 A 44 A 2 x 30 A 2 x 26 A 2 x 40 A 2 x 35 A 2 x 50 A 2 x 44 A 3 x 40 A 3 x 35 A 3 x 50 A 3 x 44 A
Number & min. recommended size of circuit breakers
Number of runs & min. recommended wire size
Maximum temperature increase above ambient water temp
Min. water flow to activate unit 0.37 gpm (1.4 l/min) 0.50 gpm (1.9 l/min) 0.50 gpm (1.9 l/min) 0.50 gpm (1.9 l/min) 0.77 gpm (2.9 l/min) 0.77 gpm (2.9 l/min) Weight 13.5 Nominal water volume 0.13 Max. inlet water temperature 131 °F (55 °C)
Dimensions
Working pressure 150 Tested to pressure 300 psi (20 bar) Water connections ¾˝ NPT
Trend & Plus
12 Trend 239213 12 Plus 239219
1 x 50
1
(DP)
2
(copper)
@
1.50
@
2.25
@
3.00
@
4.50
A 2 x 30 A 2 x 40 A 2 x 35 A 2 x 50 A 3 x 40 A 3 x 35 A 3 x 50 A
1 x 8/2
54 °F 41 °F 65 °F 49 °F 88 °F 66 °F 92 °F 82 °F 92 °F 92 °F 92 °F 92 °F 36 °F 27 °F 43 °F 37 °F 58 °F 44 °F 73 °F 54 °F 87 °F 66 °F 92 °F 82 °F 27 °F 20 °F 33 °F 25 °F 44 °F 33 °F 54 °F 41 °F 66 °F 49 °F 82 °F 61 °F
- - - - 29 °F 22 °F 37 °F 27 °F 44 °F 33 °F 55 °F 41 °F
lb (6.1 kg) 16.1 lb (7.3 kg) 16.1 lb (7.3 kg) 16.1 lb (7.3 kg) 19.0 lb (8.6 kg) 19.0 lb (8.6 kg) gal (0.5 l) 0.26 gal (1.0 l) 0.26 gal (1.0 l) 0.26 gal (1.0 l) 0.39 gal (1.5 l) 0.39 gal (1.5 l)
5
Width 16
/8˝ (42.0 cm) x Height 14½˝ (36.9 cm) x Depth 45/8˝ (11.7 cm)
psi (10 bar)
15 Trend 239214 15 Plus 239220
2 x 10/2
20 Trend 239215 20 Plus 239221
2 x 8/2
24 Trend3 239216 24 Plus3 239222
2 x 8/2
29 Trend4 239217 29 Plus4 239223
3 x 8/2
36 Trend5 239218 36 Plus5 239225
3 x 8/2
1
Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load.
2
Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to
maintain a voltage drop of less than 3% under load.
3
Requires minimum 150 a main service. 4 Requires 200 a main service. 5 Requires 300 a main service.
6
29 Trend/Plus & 36 Trend/Plus may be wired for balanced 3-phase 208 V.
15 Trend/Plus, 20 Trend/Plus, 24 Trend/Plus may be wired for unbalanced 3-phase 208 V.
These are our recommendations. Check local codes for compliance if necessary.
Due to our continuous process
of engineering and technological
advancement, specifications may
change without notice.