OPERATION AND INSTALLATION
UTILISATION ET INSTALLATION
OPERACIÓN E INSTALACIÓN
Fan heater | Calentador con ventilador | Convecteurs soufants
» CK 15 E
» CK 20 E
» CKT 15 E
» CKT 20 E
Conforms to ANSI/UL Std. 2021
Certified to CAN/CSA Std. 22.2 No. 46
Conforme a ANSI/UL Std. 2021
Certificación con CAN/CSA Std. 22.2 No. 46
Conforme à la norme ANSI/UL Std. 2021
Certifié à la norme CAN/CSA Std. 22.2 No. 46
STIEBEL ELTRON, Inc.
17 West Street | West Hatfield, MA 01088
Tel. 413-247-3380 | Fax 413-247-3369
Email info@stiebel-eltron-usa.com
www.stiebel-eltron-usa.com
CONTENTS | OPERATION
IMPORTANT INSTRUCTIONS
OPERATION
1. Important Instructions ���������������������������������������2
1.1 Document information ������������������������������������������ 2
1.2 Safety information ����������������������������������������������� 2
1.3 Other symbols in this document ������������������������������ 3
When using electrical appliances, basic precautions should always
be followed to reduce the risk of fire, electric shock, and injury to
persons, including the following:
1. Read all instructions before installing or using this heater.
2. This heater is hot when in use. To avoid burns, do not let bare
skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, etc. and curtains at least
3 feet (1 m) from the front of the heater and keep them at least 3
feet (1 m) away from the sides and rear.
3. Extreme caution is necessary when any heater is used by or
near children or invalids and whenever the heater is left operating
and unattended.
4. Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a reputable
electrician before reusing.
1.1 Document information
The chapter Operation is intended for users and heating contractors.
The chapter Installation is intended for heating contractors.
Note
Read these instructions carefully before using the appliance and familiarize yourself with its functions. Keep
these instructions safe. Pass on the instructions to a new
user if required.
1.2 Safety information
1.2.1 Structure of safety information
KEYWORD Type of risk
Here, possible consequences are listed that may result
from not observing the safety information.
f Steps to prevent the risk are listed.
2 | CK 15-20 E / CKT 15-20 E WWW.STIEBEL-ELTRON-USA.COM
OPERATION
SAFETY
1.2.2 Symbols, type of risk
SymbolType of risk
Injury
!
1.2.3 Keywords
KEYWORDDescription
DANGER If this information is not observed, it will result in serious
WARNING If this information is not observed, it can result in serious
CAUTION If this information is not observed, it can lead to medium
Electrocution
Burns or scalding
Fire
injury or death.
injury or death.
or minor injury.
1.3 Other symbols in this document
Note
Notes are bordered by horizontal lines above and below
the text. General information is identified by the symbol
shown on the left.
f Read these notes carefully.
Symbol
Damage to the appliance and environment
!
Appliance disposal
2.2 Safety information
Operate the appliance only when fully installed and with all safety
equipment fitted.
The heater must be properly installed before it is used.
DANGER Electrocution
- Before cleaning, make sure the power has been
turned off at the circuit breaker panel and that the
heating element of the heater is cool.
DANGER Fire
Never operate this appliance ...
- if the minimum clearances to adjacent object sur-
faces are not maintained, for example to furniture,
net curtains, curtains, textiles or other flammable
materials (for minimum clearances, see "specification/dimensions and minimum clearances").
- in rooms where the appliance is at risk from fire or
explosion as a result of chemicals, dust, gases or
vapors.
- in the direct proximity of pipes or containers that
carry or contain flammable or explosive materials.
- if work such as laying cables, grinding or sealing is
carried out in the installation room.
- if sprays, floor polish or similar products containing
gasoline are used. Vent the room sufficiently before
heating.
- if an appliance component is damaged, the appli-
ance has fallen over or already had a fault.
- outdoors.
DANGER Fire
Never place any flammable, combustible or insulating
objects or materials, such as laundry, blankets, magazines, containers with floor polish or gasoline, spray cans
or similar on the appliance or in direct proximity to it.
WARNING Fire
Ensure that no foreign bodies enter the ventilation air
and extract air apertures. This could result in electric
shock or fire or in damage to the appliance.
ENGLISH
Never cover the appliance
f This symbol indicates that you have to do something. The ac-
tion you need to take is described step by step.
2. Safety
Observe the following safety information and regulations.
Operate the appliance only when fully installed and with all safety
equipment fitted.
2.1 Intended use
This appliance is designed to heat living areas.
Any other use beyond that described shall be deemed inappropri-
ate. Observation of these instructions is also part of the correct
use of this appliance. Any modifications or conversions to the
appliance void all warranty rights.
WWW.STIEBEL-ELTRON-USA.COM CK 15-20 E / CKT 15-20 E| 3
WARNING Fire
To prevent fires ensure that the air inlets and outlets are
never blocked. Never position the appliance on soft surfaces, such as a bed, as this could result in the apertures
becoming blocked.
DANGER Overheating
The appliance could continue to heat the room unchecked
if it is operated on a time switch. Ensure constant su-pervision if the appliance is used in a small room and
the persons within that room cannot leave the room on
their own.
WARNING Injury
!
Where children or persons with limited physical, sensory
or mental capabilities are to be allowed to control this
appliance, ensure that this will only happen under supervision or after appropriate instructions by a person
responsible for their safety.
Children should be supervised to ensure that they never
play with the appliance.
OPERATION
REGISTER YOUR PRODUCT
CAUTION Burns
The casing surfaces of the appliance and the expelled
air become hot during use (above 90 °C (194 °F)). To prevent burns ensure that the hot surfaces never come into
contact with bare skin.
Damage to the appliance and the environment
!
- Never cover this appliance.
- Never step on the appliance.
2.3 Licences / certificates
- UL (U.S.A) Std. 2021
- CSA (Canada) Std. 22.2 No. 46
2.4 Test symbols
See type plate on the appliance.
3. Register your product
You must register this product within 90 days of
purchase on our web site in order to activate the
standard warranty or to be eligible for the extended
warranty. Go to our web site at
www.stiebel-eltron-usa.com and click on register
your product.
Before beginning the registration process, we suggest that
you gather the necessary information which will be as
follows:
4.1 Control with external room temp. controller
(Only applicable for: CK)
In rooms larger than 215 ft2 (20 m2) you can operate the appliance
with a conventional wall mounted room thermostat.
f To do so, turn the temperature selector fully clockwise.f Control the temperature by using the wall thermostat.
5. Operation CK 15 E / CK 20 E
1
26�07�31�0211
1 Temperature selector
5.1 Starting heating
The temperature is infinitely adjustable. The appliance stops heating as soon as the selected room temperature has been reached.
f Turn the temperature selector clockwise to the required
setting.
Type, Example: CK 15 E (from the white label that is on the
right side of the unit)
Number listed after “Nr.”
Place of Purchase
Purchase Date
First & Last Name
Email address
Physical Address
Phone Number
IF YOU HAVE ANY QUESTIONS CONCERNING THE REGISTRATION PROCESS OR WARRANTY OPTIONS, PLEASE CONTACT
STIEBEL ELTRON USA DIRECTLY AT (800)-582-8423.
4. Appliance description
This appliance is wall mounted and is particularly suitable for work
rooms, kitchens, bathrooms, wash rooms and similar.
The external casing of the appliance is made from stove enameled
sheet steel. The sides are made out of plastic. The controls are
located on the right side panel.
The quiet fan draws in the ambient air that is heated by a bare wire
heater element. The air then exits evenly through the hot air channel and the air outlet grille set into the bottom of the appliance.
5.2 Stopping heating / frost protection
To ensure frost protection, the power switch must be
!
in the on position.
f Turn the temperature selector fully counter clockwise.
This position ensures frost protection. The heater starts automatically if the room temperature drops below the frost protection
temperature.
6. Operation CKT 15 E / CKT 20 E
1
2
1 Temperature selector
2 Timer
26�07�31�0214
The appliance heats up the ambient air inside the room and maintains it at the selected temperature.
4 | CK 15-20 E / CKT 15-20 E WWW.STIEBEL-ELTRON-USA.COM
OPERATION
CLEANING, CARE AND MAINTENANCE
6.1 Starting heating
The temperature is infinitely adjustable. The appliance stops heating as soon as the selected room temperature has been reached.
f Turn the temperature selector clockwise to the required
setting.
6.2 Adjusting the time switch
With the time switch, the appliance heats with full output and
without temperature control.
f Turn the Timer clockwise to set any number of minutes to
count down from 0-60minutes.
6.3 Stopping heating / frost protection
This position ensures frost protection. The heater starts automatically if the room temperature drops below the frost protection
temperature.
f Turn the temperature selector fully counter clockwise and
ensure that the time switch is set to "0".
7. Cleaning, care and maintenance
The appliance contains no user serviceable parts.
Clean the appliance when cold with ordinary cleaning products.
Avoid abrasive or corrosive cleaning products.
If a pale brownish discoloration appears on the appliance casing,
wipe this off as soon as possible with a damp cloth.
Damage to the appliance and the environment
!
Never spray cleaning spray into the air slot.
INSTALLATION
10. Safety
Only licensed electricians should carry out the maintenance and
repair of this appliance.
10.1 General safety information
We guarantee trouble-free operation and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
10.2 Instructions, standards and regulations
Note
Observe all applicable national and local regulations and
instructions.
11. Appliance description
This appliance is a wall mounted electric heater. It is particularly
suitable for heating rooms, such as work rooms, kitchens, bathrooms, wash rooms etc.
11.1 Standard delivery
- Wall mount bracket
- Bottom bracket
12. Installation
ENGLISH
8. Storage
f When not in use, keep the appliance in a dry place.
9. Troubleshooting
If the appliance does not heat, check the temperature set at the
appliance and the circuit breacker.
The appliance has a safety high limit that shuts the appliance down
if it overheats. After the cause has been removed (for example air
outlet or inlet apertures covered) and the appliance has cooled
down for a few minutes, operation starts again.
If you cannot remedy the fault, notify the contractor who installed
the appliance. To facilitate and speed up your enquiry, please provide the serial number from the type plate (000000-0000-000000).
DANGER Electrocution
- If installing the appliance in rooms with a bath and/
or shower, take the relevant safety zone into account in accordance with the information on the appliance type plate.
- Install the appliance in such a way that switching
and control equipment cannot be touched by a person in the bath or shower.
DANGER Fire
- Only fit the appliance to a vertical wall that is heat-
resistant to at least194°F(90 °C).
- Maintain minimum clearances to adjacent surfaces.
- Never install the appliance directly below a wall
socket.
f Check the hole distances for the wall mounting bracket in the
dimensioned drawing.
f Secure the wall mounting bracket with suitable fasteners.
The horizontal and vertical slots in the wall mounting bracket
enable alignment if drilled holes are not completely accurate.
f Hook in the appliance so that both top protrusions are in-
serted into the slots in the wall mounting bracket.
WWW.STIEBEL-ELTRON-USA.COM CK 15-20 E / CKT 15-20 E| 5
INSTALLATION
ELECTRICAL CONNECTION
f Secure the appliance with the bottom bracket and one screw
against unintentional unhooking. To do so, hook the bottom
bracket from the back into the rear panel.
13. Electrical connection
DANGER Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
Damage to the appliance and the environment
!
- Observe the type plate. The specified voltage must
match the mains voltage.
Never install the appliance directly below an outlet.
In case of ROMEX wire, install ½" ROMEX connector in knockout.
In case of Greenfield, please use ½" Greenfield connector.
13.1 Removing the front cover
Remove the two screws at the bottom of the unit. Once removed,
the front face can be removed by pulling it towards you.
13.3 Terminal block
Route the power cable through the cable entry hole and into the
terminal block. The ground wire screw is located above the terminal block.
1
1 Terminal block
Consult the chart below for the recommended torque amounts on
the terminal block screws.
1
1 Screw locations for removing cover
13.2 Routing wire to the terminal block
There is a hole for cable entry in the back of the unit. Install a
cable clamp to prevent the power cable from being pulled out of
the terminal block during operation.
1
Screw Size (mm) Min. Torque (N•cm)Min. Torque (lbf•in)
M3.560-805.31-7.08
Using the proper torque specifications to secure wire to the wiring
block helps to avoid personal loss or property damage.
14. Appliance handover
Explain the functions of the appliance to the user. Draw special
attention to the safety information. Hand the operating and installation instructions to the user.
1 Cable entry
6 | CK 15-20 E / CKT 15-20 E WWW.STIEBEL-ELTRON-USA.COM
f The images above show minimum allowed clearances be-
tween the installed appliance and any hard surfaces.
f We recommend installing the appliance 6-8˝ off the floor.
WARNING Fire
Combustible materials such as furniture, papers, clothes
and curtains must be kept at least 3 feet (0.9 m) from
the heater.
Never place any flammable, combustible or insulating
objects or materials, such as laundry, blankets,
magazines, containers with floor polish or gasoline,
spray cans or similar on the appliance or in direct
proximity to it.
WWW.STIEBEL-ELTRON-USA.COM CK 15-20 E / CKT 15-20 E| 7
INSTALLATION
SPECIFICATION
15.3 Specification table
CK 15 ECK 20 E
Part number074058074057
Power supplysingle phasesingle phase
Voltage120 V240 V208 V
Wattage1500 W2000 W1500 W
Amperage12.5 A8.3 A7.5 A
Required circuit breaker size15 A15 A15 A
Required wire size14 AWG14 AWG14 AWG
Temperature range41°F - 86°F / 5°C - 30°C
Frost protection setting44.6°F / 7°C
Operating noise49.7 dB(A)
Height18.1˝ / 46 cm
Width13.2˝ / 33.5 cm
Depth4.8˝ / 12.3 cm
Weight8.0 lb / 4.4 kg
CKT 15 ECKT 20 E
Part number230345230346
Power supplysingle phasesingle phase
Voltage120 V240 V208 V
Wattage1500 W2000 W1500 W
Amperage12.5 A8.3 A7.5 A
Required circuit breaker size15 A15 A15 A
Required wire size14 AWG14 AWG14 AWG
Temperature range41°F - 86°F / 5°C - 30°C
Frost protection setting44.6°F / 7°C
Operating noise49.7 dB(A)
Height18.1˝ / 46 cm
Width13.2˝ / 33.5 cm
Depth4.8˝ / 12.3 cm
Weight8.0 lb / 4.4 kg
15.4 Wiring diagram CK 15 E
A1
R1R2
>171°F ± 9°F
ϑ
>80°C ± 5K
>171°F ± 9°F
ϑ
>80°C ± 5K
N1
>
ϑ
GRD L1N
CK 15 E:
A1 Electric heating element assembly
F1 Temperature high limit
8 | CK 15-20 E / CKT 15-20 E WWW.STIEBEL-ELTRON-USA.COM
INSTALLATION
SPECIFICATION
15.5 Wiring diagram CKT 15 E
A1
>171°F ± 9°F
ϑ
>80°C ± 5K
>171°F ± 9°F
ϑ
>80°C ± 5K
N1
>
ϑ
2
T1
3
1
R1R2
F2
15.6 Wiring diagram CK 20 E
A1
M
1
~
M1
F1
>171°F ± 9°F
ϑ
>80°C ± 5K
>171°F ± 9°F
ϑ
>80°C ± 5K
N1
ϑ
R1R2
F1
F2
>
M
1
~
M1
ENGLISH
X1
1
2
CKT 15 E:
GRD L1N
A1 Electric heating element assembly
F1 Temperature high limit
M1 Fan
N1 Thermostat
R1 Heating resistor
R2 Heating resistor
T1 60 minute timer
X1 Wiring block
1
GRD L1L2
CKT�15�SP�TS
CK 20 E:
A1 Electric heating element assembly
F1 Temperature high Limit
M1 Fan
N1 Thermostat
R1 Heating resistor
R2 Heating resistor
X1 Wiring block
X1
2
CK�20�DP�TS
WWW.STIEBEL-ELTRON-USA.COM CK 15-20 E / CKT 15-20 E| 9
INSTALLATION
GRD L1 L2
CKT 20 E:
SPECIFICATION
15.7 Wiring diagram CKT 20 E
A1
R1R2
M
1
~
M1
>171°F ± 9°F
ϑ
6
2
>80°C ± 5K
>171°F ± 9°F
ϑ
>80°C ± 5K
5
4
X1
N1
>
ϑ
2
T1
3
1
S1
1
A1 Electric heating element assembly
F1
F2
CKT�20�DP�TS
F1 Temperature high Limit
M1 Fan
N1 Thermostat
R1 Heating resistor
R2 Heating resistor
S1 Dual-pole on/off switch
T1 60 minute timer
X1 Wiring block
10 | CK 15-20 E / CKT 15-20 E WWW.STIEBEL-ELTRON-USA.COM
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.