Stiebel Eltron 074056 Instruction Manual

Page 1
Proven Point-of-Use Dependability
Exclusive copper-clad heating element
DHC Series
POINT-OF-USE
TANKLESS ELECTRIC WATER HEATERS
800.582.8423
Unlimited Supply of Hot Water
Hydraulically Controlled for Quiet Operation
Major Energy Savings
Proven Reliability
www.stiebel-eltron-usa.com
Page 2
Ideal For All Point-of-Use Water Heating Applications
Stiebel Eltron DHC tankless electric water heaters are the ideal choice for all point-of-use hand washing applications:
Commercial Industrial Institutional Residential
Office buildings
Stores Malls Warehouses Restaurants
Stiebel Eltron DHC tankless water heaters are designed for installation at the point-of­use. The DHC heats water instantaneously as it flows through the unit. Stand-by heat losses are completely eliminated.
Gas stations Schools Hotels/Motels Commercial condominiums Manufacturing facilities
Copper heating
Bathroom sinks Kitchen sinks Laundry areas Cabins/cottages
system
The heating element is controlled by a flow switch which means a DHC can never dry-fire and fail prematurely. And since all DHCs are hydraulically controlled, operation is quiet. DHC water heaters are equipped with a safety high-limit with manual reset. The rugged all copper design ensures many years of reliable service.
DHC 3-1, DHC 3-2 and DHC 4-2 models are shipped with 0.5 GPM pressure compensating flow reducer/aerators that fit on most faucets. Flow controls and faucet aerators are highly recommended in conjunction with tankless water heaters. No pressure relief valve, drains, or circulating pumps needed.
Safety thermal
cut-out
Flow switch
Wiring block
Cold water connection
Hot water
connection
Engineer’s Specifications: The tankless electric water heater shall be equipped
with a copper sheathed heating element housed in a copper cylinder. The flow switch that operates the heating element shall be of the mechanical pressure differential type. The unit shall be equipped with a safety high-limit switch with manual reset. An integral tamper-proof flow adjustment screw shall be provided for the installer so that water flow rates can easily be adjusted. The water connec­tions shall be designed for ½˝ NPT female adapter. The housing shall be made of high impact polycarbonate plastic.
Page 3
Flow
R
Std.
High
DHC Sizing Guide
GPM
0.5
1.0
DHC 3-1 DHC 3-2 DHC 4-2
120 V Minimum 25 A circuit breaker
240 V Minimum 15 A circuit breaker
Single Sink Tankless Electric Water Heater
DHC MODEL
240 V Minimum 20 A circuit breaker
DHC 4-3
277 V Minimum 20 A circuit breaker
240 V Minimum 20 A circuit breaker
DHC 6-2 DHC 8-2 DHC 9-3 DHC 10-2DHC 5-2
240 V Minimum 25 A circuit breaker
240 V Minimum 30 A circuit breaker
Minimum 35 A circuit breaker
277 V
240 V Minimum 40 A circuit breaker
code
Low
Std.
2.0
1.0
2.0
Non-
LAVATORY SINK
KITCHEN SINK
Utility / Janitor’s
1.0 -2.0
Sink
DHC 3-1, 3-2, 4-2 ship with a 0.5 GPM pressure compensating flow reducer/aerator that must be installed.
Depend on them!
Exclusive copper-clad
heating element
Hydraulically controlled for
virtually silent operation
Never dry fires and fails
prematurely
Superior reliability
AK
BC
AB
WA
OR
CA
MT
ID
NV
UT
AZ
HI
Cool (Northern) Climate
Inlet water 45°F - 55°F
SK
MB
ND
MN
SD
WY
CO
NM
WI
IA
NE
KS
MO
OK
AR
LA
TX
ON
IL
MS
QC
MI
PA
OH
IN
WV
VA
KY
NC
TN
SC
AL
GA
FL
PE
NB
NS
ME
VT
NH
MA
NY
RI
CT
NJ DE MD
7 years leakage/
3 years par ts.
Complete warranty
online.
Conforms to ANSI/UL
Std. 499
Certified to CAN/CSA
E335-1 & E335-2-35
Tested and certified
by WQA against NSF/
ANSI 372 for lead free
compliance.
Warm (Southern) Climate
Inlet water 55°F - 70°F
ecommendations for 240 V models are correct if installed with 240 V service.
Increase one model size if unit will be installed with 208 V service.
Call Stiebel Eltron at 800.582.8423 if you have any sizing questions, or if you have any out-of-the-ordinary
situation. Stiebel Eltron service representatives can make recommendations on sizing, or provide
assistance with our water heaters, to both homeowners and professional installers.
Page 4
Technical Data
Model DHC 3-1 DHC 3-2 DHC 4-2 DHC 4-3 DHC 5-2 DHC 6-2 DHC 8-2 DHC 9-3 DHC 10-2
Item no. 074050 074052 074053 074051 074054 074424 074055 232204 074056
- 50/60 Hz 1
Phase Voltage 120 Wattage 3.0 kW 3.3 kW 2.5 kW 3.8 kW 2.9 kW 4.5 kW 4.8 kW 3.6 kW 6.0 kW 4.5 kW 7. 2 kW 5.4 kW 9.0 kW 9.6 kW 7.2 kW Amperage 25 A 14 A 12 A 16 A 14 A 17 A 20 A 18 A 25 A 22 A 30 A 26 A 32.5 A 40 A 35 A
Min. recommended circuit breaker size
Min. recommended wire size 210/2 AWG 14/2 AWG 12/2 AWG 14/2 AWG 12/2 AWG 12/2 AWG 10/2 AWG 10/2 AWG 8/2 AWG 8/2 AWG
Minimum water flow to activate unit
Weight 4.6 lb / 2.1 kg 5.3 lb / 2.4 kg 5.3 lb / 2.4 kg 4.6 lb / 2.1 kg 4.6 lb / 2.1 kg 4.6 lb / 2.1 kg 5.3 lb / 2.4 kg 5.3 lb / 2.4 kg 5.3 lb / 2.4 kg
Dimensions (H x W x D)
Nominal water volume 0.13 gal / 0.5 l Working pressure 150 Tested t o pressure 300 psi / 20 BAR
Water connections
DHC 3-1, 3-2, 4-2 ship with a 0.5 GPM pressure compensating fl ow-reducer/aerator that must be installed.
1
This is our recommendation for overcurrent protection sized at 100% of load (DP for 240/208/277 V & SP for 120 V models).
Check local codes for compliance if necessary. Tankless water heaters are considered a non-continuous load.
2
Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
3
Suitable for supply with cold water only.
1
3
V 240 V 208 V 240 V 208 V 277 V 240 V 208 V 240 V 208 V 240 V 208 V 277 V 240 V 208 V
25 A 15 A 15 A 20 A 15 A 20 A 20 A 20 A 25 A 25 A 30 A 30 A 35 A 40 A 35 A
0.32 GPM
1.2 l/min
143/16 / 36.0 cm x 77/8 / 20.0 cm x 41/8 / 10.4 cm
psi / 10 BAR
½ NPT
Certified to ANSI/UL Std. 499 Conforms to CAN/CSA E335-1 & E335-2-35
0.32 GPM
1.2 l/min
0.42 GPM
1.6 l/min
0.42 GPM
1.6 l/min
Tested and cer tified by WQA against NSF/ANSI 372 for lead free compliance.
0.42 GPM
1.6 l/min
0.47 GPM
1.8 l/min
0.69 GPM
2.6 l/min
0.79 GPM
3.0 l/min
0.79 GPM
3.0 l/min
Temperature Rise vs. Flow Rate at Maximum Rated Voltage
90 80
70
0.69
60
50
40
Temp Rise °F
30
20
10
0
Limited Warranty (Excerpt): Subject to the terms and conditions set forth in this limited war­ranty, Stiebel Eltron, Inc. hereby warrants to the original purchaser that each Tankless Electric Domestic Hot Water Heater shall not (i) leak due to defects in the Manufacturer’s materials or workmanship for a period of seven (7) years from the date of purchase or (ii) fail due to defects in the Manufacturer’s materials or workmanship for a period of three (3) years from the date of purchase. Complete warranty details available online.
Due to our continuous process of engineering and technological advancement, specifications may change without notice.
0.79
0.750.5 1.0 1.25 1.5 1.75 2.0
Flow Rate GPM
7 years leakage
& 3 years parts.
Complete warranty
DHC 10-2
DHC 9-3
DHC 8-2
DHC 6-2
DHC 5-2
DHC 4-3
DHC 4-2
DHC 3-2
DHC 3-1
17 West Street West Hatfield, MA 01088
TOLL FREE 800.582.8423
PHONE 413.247.3380 FAX 413.247.3369
info www.stiebel-eltron-usa.com
Printed on recycled chlorine-free paper with soy-based inks. #20-1.201 9
online.
@stiebel-eltron-usa.com
Loading...