Steca Solarix 2020-x2 Installation And Operating Instructions Manual

EN
Solar charge controller
Solar charge controller for two batteries 12 V/24 V 20 A
Installation and operating instructions
EN About these operating instructions
Contents
1 About these operating instructions ........................................... 2
2 Safety ........................................................................................ 3
3 Description ................................................................................ 4
4 Installation ................................................................................ 7
5 Maintenance ........................................................................... 12
6 Self test ................................................................................... 12
7 Faults and remedies ................................................................ 13
8 Technical data ......................................................................... 18
9 Commercial and legal guarantee conditions ........................... 22
1 About these operating instructions
These operating instructions are part of the product.
Read these operating instructions carefully before use. Keep these operating instructions in the vicinity of the
product over the entire lifetime of the product.
Pass these operating instructions on to every subsequent user
of the product.
1.1 Description of symbols
Safety instructions are labelled as follows:
Keyword
Measures for avoiding danger
Instructions relating to the functional safety of the system are in bold type.
2 751.792 | Z01 | 1504
Safety EN
2 Safety
2.1 Designated use
The solar charge controller may only be used for charging
and controlling lead-acid batteries (with liquid or solid electrolyte).
The solar charge controller may only be connected to a solar
generator (solar module or array of solar modules within the limits of the permissible connection values) and must not be connected to any other energy source.
The specifications of the solar charge controller and the
connected components listed in these operating instructions must be adhered to.
The manufacturer’s specifications for the solar modules and
batteries must be adhered to.
2.2 General safety instructions
Follow the general and national safety and accident
prevention regulations.
The factory-applied labels on the device must not be
modified or removed.
Keep children away from photovoltaic systems. Do not open the device.
751.792 | Z01 | 1504 3
EN Description
Danger of fire and explosion
Do not use the solar charge controller in any of the
following situations:
- In dusty environments
- In the vicinity of solvents
- In environments where inflammable gases and
vapours can be present
Do not expose the batteries to open flames or sparks. Ensure that the room is adequately ventilated. Perform regular checks to ensure that the system is
functioning (charging) correctly.
Follow the charging instructions of the battery
manufacturer.
3 Description
The solar charge controller utilises the electrical power generated by solar modules for charging two batteries and for directly supplying electrical loads.
Product features:
Automatic voltage adjustment 12 V/24 V DC Charging of main and auxiliary batteries Monitoring of the charge state of the batteries Dynamic charge control depending on the charge state of the
batteries (charging priority given to the main battery)
Automatic switch-on after shutdown Suitable for systems with negative pole connected to
common ground
Solar charge controller provides overcharge protection and
deep discharge protection for the batteries
Automatic monthly maintenance charge Hibernation mode Separate load circuit for external loads (can only be used
when the main battery is sufficiently charged; indicated by LED 4 lit up yellow or green at the load output)
4 751.792 | Z01 | 1504
Description EN
USB charge socket (e.g. for charging a mobile phone) Can be expanded with an external remote display Can be integrated into the StecaLink bus system
Structure:
1 LED 1 and terminal block for auxiliary battery (battery II) 2 LED 2 and terminal block for solar module 3 LED 3 and terminal block for main battery (battery I) 4 LED 4 and terminal block for connecting loads (load circuit) 5 Plastic housing 6 Connection for StecaLink bus system 7 USB charge socket 8 Fastening holes (4 holes)
The solar charge controller can be used indoors and in vehicles. The charging programme is optimised for one main battery and one auxiliary battery.
All types of lead-acid batteries can be connected (with liquid or solid electrolyte).
751.792 | Z01 | 1504 5
EN Description
Battery charge state
LED 1 and LED 3 displays (solar module not charging)
LED 1 and LED 3 dis­plays (solar module charging)
100 %
Green flashing1)
Green slowly alternating between bright/dark
Green fully lit2)
50 %
Yellow fully lit
Yellow slowly alternating between bright/dark
0 %
Red fully lit
3)
Red slowly alternating between bright/dark
Red flashing4)
When only one battery is used then this must be connected to the main battery terminals.
The charging times depend on the power provided by the solar module and the capacity of the battery.
With a maximum load current of 20 A the load circuit is suitable for external appliances with a power rating of up to 240 W at 12 V and 480 W at 24 V.
The solar charge controller begins operating as soon as a battery is connected. If the solar module delivers no voltage for more than 48 hours, the solar charge controller will enter hibernation mode (all LEDs are deactivated). When a voltage is delivered again by the solar module, the charge controller will resume functioning again within 30 minutes.
The user does not need to operate the solar charge controller or make any settings.
Four multicolour LEDs indicate the operating status, charge state and any faults that may occur (see “Faults and remedies”).
LED displays
1 )
Cut-off voltage reached, excess energy available
2 )
Charge state: fully charged
3 )
Charge state: low charge
4 )
Battery deeply discharged
6 751.792 | Z01 | 1504
Installation EN
LED 2 Solar module
Meaning
Green fully lit
Solar module connected, no charging current flowing
Green slowly alternating between bright/dark
Charging current flowing Yellow fully lit
Solar module voltage too low
Off
Solar module voltage below 8 V
LED 4 Load circuit
Meaning
Green fully lit
Load switched on
Green slowly alternating between bright/dark
Special function switched on (only in conjunction with an optional external remote display)
Yellow fully lit
Pre-warning: battery weak
Off
Load circuit switched off to protect the batteries
4 Installation
Danger of fire and explosion
The solar charge controller may only be connected to
loads and the batteries by suitably trained and qualified personnel in accordance with the applicable regulations.
The installation and operating instructions for all com-
ponents of the photovoltaic system must be observed.
Ensure that no cables are damaged.
Do not mount the solar charge controller outdoors or in wet
rooms.
Do not subject the solar charge controller to direct solar
irradiation or other sources of heat.
Protect the solar charge controller from dirt and moisture.
751.792 | Z01 | 1504 7
EN Installation
Ø approx. 5 mm
Mount the solar charge controller upright on a non-
inflammable surface.
Maintain a minimum clearance of 10 cm above and below
the unit to ensure free circulation of air.
Mount the solar charge controller as close as possible to the
batteries (but with a safety clearance of at least 30 cm).
Step 1 Mounting the solar charge controller
1. Use the drilling template to mark the hole positions on the wall.
2. Drill 4 holes (Ø depending on the wall material and the fasteners used).
3. Use 4 suitable screws (not provided) to fasten the con­troller to the wall. The cable openings must face down­wards.
Step 2 Connecting the solar charge controller
Danger of fire and explosion
Solar modules generate electricity under incident light.
The full voltage is present, even when the incident light levels are low. You must therefore protect the solar modules from incident light during installation, e.g. cover them.
Do not touch exposed cable ends. Take care to ensure that the cables do not touch each
other.
Use only insulated tools. Ensure that all loads to be connected are switched off. Connections must always be made in the sequence
described below.
8 751.792 | Z01 | 1504
Installation EN
Distance
3 m
5 m
10 m
Current
20 A
4 mm²
6 mm²
10 mm²
10 A
2.5 mm²
4 mm²
6 mm²
5 A
2.5 mm²
2.5 mm²
4 mm²
Cable terminal tighten­ing torque
1.2 Nm
Cable lengths
Max of 10 m for solar module connection cable
Max of 2 m for battery connection cable
Max of 10 m for load connection cable
Reference potential
Common negative pole (negative pole connect­ed to common ground), earthing is not re­quired
Fuse
30/40 A
Load output
240 W
max
(12 V)
480 W
max
(24 V)
U
max
=60 V
I
max
=20 V
Fuse
30/40 A
max. 2 m
2.5-10 mm² max. 10 m
2.5-10 mm²
max. 2 m
2.5-10 mm²
2.5-10 mm²
max. 10 m
Cable cross sections
The specified cable cross sections are minimum values. Please choose somewhat higher cross sections (max. 10mm²) for a higher efficiency.
751.792 | Z01 | 1504 9
EN Installation
Connecting the batteries (first battery I, then battery II)
The main battery is connected to “Battery I”, the auxiliary battery is connected to “Battery II”.
1. Label the battery connection cables as a plus cable (B1+ or B2+) and a minus cable (B1- or B2-).
2. Lay the battery connection cables parallel to each other between the solar charge controller and the batteries, but do not yet connect them.
3. Install a 30 A (for a cable cross-section of 6 mm2) or 40 A (for a cable cross-section of 10 mm2) fuse with fuse holder in the plus cable as close as possible to the battery pole. (The fuse holder is not included in the scope of delivery.)
4. Remove the fuse from the fuse holder.
5. Connect the battery connection cables with the correct polarity to the terminal pairs with the corresponding battery symbol (battery I or battery II).
6. Connect the plus cable to the positive pole of the battery.
7. Connect the minus cable to the negative pole of the battery. The negative pole can be earthed if required.
8. Insert the external fuse
When the battery is correctly connected, LED 1 or LED 3 lights up green, yellow or red depending on the charge state. LED 4 lights up green or yellow depending on the charge state of the main battery.
Connecting the solar module
1. Ensure that the solar module is protected from incident light.
2. Label the solar module connection cables as a plus cable (M+) and a minus cable (M–).
3. Lay the two solar module connection cables parallel to each other between the solar module and the solar charge controller, but do not yet connect them.
4. Connect the plus cable M+ with the correct polarity to the solar module terminal pair on the solar charge controller.
10 751.792 | Z01 | 1504
Installation EN
5. Connect the minus cable M- with the correct polarity to the solar module terminal pair on the solar charge controller.
6. Remove the covering from the solar module.
When the solar module is correctly connected, LED 2 lights up green (permanently or alternating between bright/dark).
Connecting loads
Loads that must not be deactivated by the solar charge controller deep discharge protection, e.g. emergency lights or radio connection, can be connected directly to the battery and separately fused.
1. Ensure that the loads are switched off and the corresponding fuses are removed.
2. Label the load connection cables as a plus cable (L+) and a minus cable (L–).
3. Lay the load connection cables parallel to each other between the solar charge controller and the loads, but do not yet connect them.
4. First connect the L+ load cable with the correct polarity to the right pair of terminals on the solar charge controller (with the lamp symbol).
5. Then connect the L- load cable with the correct polarity to the right pair of terminals on the solar charge controller (with the lamp symbol).
6. Replace any removed fuses and then switch on the loads.
When the loads are correctly connected, LED 4 remains lit in green or yellow.
Step 3 Completion work
1. Secure all cables in the immediate vicinity of the solar charge controller using strain relief fittings (clearance of approx. 10 cm).
2. Check the LED displays.
The solar charge controller is ready for operation.
751.792 | Z01 | 1504 11
EN Maintenance
Display
Meaning
LEDs 1 to 4 flash green
Self test passed, no device faults
LEDs 1 to 4 flash red
Internal power supply fault or tem­perature sensor fault
LED 1 flashes red
Fault in auxiliary battery charge control
5 Maintenance
Clean the solar charge controller as necessary using a brush
or soft cloth. Do not use water for cleaning.
Ensure adequate ventilation at the rear side of the housing
(heatsinks).
Check the cable strain relief. Check that all cable connections are secure. Tighten screws if
necessary.
Check all terminals for signs of corrosion. All components of the photovoltaic system must be checked
at least annually, according to the specifications of the respective manufacturers.
6 Self test
A self test of the solar charge controller can be executed if required. An adjustable, stabilised power supply unit with current limiting is required for the self test.
1. Disconnect all connections to the solar charge controller and wait for at least 1 minute.
2. Adjust the power supply to a voltage of 7.25 V (± 0.25 V) and set the current limit to max. 2 A (0.5 A to 2 A).
3. Connect the power supply unit with the correct polarity to the solar module terminals.
The self test starts automatically. The results are displayed according to the following table:
12 751.792 | Z01 | 1504
Faults and remedies EN
Display
Meaning
LED 2 flashes red
Defective USB charge socket
LED 3 flashes red
Fault in main battery charge control
LED 4 flashes red
Defective load switch
7 Faults and remedies
After a shutdown the supply to the loads in the load circuit and the battery charging are resumed as soon as the conditions causing the shutdown are again within a permissible range.
Please consult your point of sale if the fault cannot be corrected using the measures described.
Fault display LEDs
751.792 | Z01 | 1504 13
EN Faults and remedies
Error/ Fault message
Cause
Remedy
No display
Hibernation mode active
- Check solar module voltage
- Wait 30 minutes
Battery voltage too low
Charge the battery
The external fuse in the battery connection cable has blown
Replace the external fuse
Battery (Battery I) not connected
- Disconnect all connec­tions
- Connect a (new) bat­tery
- Reconnect the solar module and loads
Battery is defec­tive
LEDs 1 and 3 flash red, LEDs 2 and 4 flash yellow
Internal power supply fault or temperature sensor fault
Replace the solar charge controller
LEDs 1 to 4 flash yellow/red
Shutdown due to overtemperature
Check the load circuit for overload and/or reduce the load if necessary
14 751.792 | Z01 | 1504
Faults and remedies EN
Error/ Fault message
Cause
Remedy Load circuit
LED 4 lights up red
Short circuit in load circuit
- Disconnect loads
- Correct the cause of
the short circuit
- Reconnect loads
LED 4 flashes red (slowly)
Overload warning
Reduce current con­sumption of the loads, if necessary switch off or disconnect loads
LED 4 flashes red (fast)
Shutdown due to overload
Reduce current con­sumption of the loads, if necessary switch off or disconnect loads
LED 4 off
Shutdown due to battery un­dervoltage
- Charge the battery
- Equip loads directly
connected to the bat­tery with deep dis­charge protection
- Check the battery and replace if necessary
751.792 | Z01 | 1504 15
EN Faults and remedies
Error/ Fault message
Cause
Remedy Battery
LED 1 and/or LED 3 lights up blue
Battery is con­nected with the wrong polarity
Connect the battery with the correct polarity
LED 1 and/or LED 3 flashes red/green
Battery overvolt­age
- Disconnect the battery
- Correct the cause of
the overvoltage
- Reconnect the battery
LED 1 and LED 3 flash red alter­nately
Impermissible battery combina­tion 24 V battery (battery I) and 12 V battery (battery II)
- Disconnect the batter­ies
- Connect a permissible battery combination
16 751.792 | Z01 | 1504
Faults and remedies EN
Error/ Fault message
Cause
Remedy Solar module
LED 2 lights up blue
Solar module connected with incorrect polarity
Connect the solar mod­ule with the correct polarity
LED 2 lights up red
Short circuit at solar module input
Correct the cause of the short circuit
LED 2 flashes red (slowly)
Solar module overcurrent
- Disconnect the solar module
- Correct the cause of the overcurrent
- Reconnect the solar module
LED 2 flashes red (fast)
Shutdown due to overcurrent
- Disconnect the solar module
- Correct the cause of the overcurrent
- Reconnect the solar module
LED 2 flashes red/green
Solar module overvoltage
- Disconnect the solar module
- Correct the cause of the overvoltage
- Reconnect the solar module
751.792 | Z01 | 1504 17
EN Technical data
Dimensions
190 mm x 120 mm x 58 mm
Weight
500 g
Current consumption
Approx. 20 mA
Reference potential
Minus
Earthing
The negative pole can be earthed but this is not essen­tial. Never earth the plus pole!
Maximum heatsink tempera­ture (rear side of unit)
70 °C Protection class
IP 31
Ambient temperature T
amb
-20 °C to +50 °C
Power limiting possible at T
amb
> 40 °C (depending on other operating conditions
Storage temperature
-30 °C to +70 °C
Maximum short-circuit current
20 A
Maximum open-circuit voltage
60 V DC
Reverse polarity protection at module input
Up to 36 VDC
8 Technical data
General information
Solar module
18 751.792 | Z01 | 1504
Technical data EN
Type
Lead-acid batteries with gel (default setting) or liquid elec­trolyte
Voltage
12 V DC / 24 V DC
Battery I
Battery II
Mixed connection of 12 V and 24 V batteries is only permitted according to the adjacent table.
12 V
12 V
24 V1)
24 V1)
12 V
24 V1)
Not permitted!
The solar charge controller
can be damaged.
24 V
12 V
Line compensation
Automatic compensation of the charge cut-off voltage by the voltage drop value deter­mined across the battery cable
Temperature compensation of the charge cut-off voltage
-4 mV/K/cell (initial value at 25 °C)
Battery charging
1 )
Solar module voltage U
751.792 | Z01 | 1504 19
30 V required
mpp
EN Technical data
Detailed battery charging data
12 V system
24 V system
Permissible battery voltage range
9-17 V
17.1-34 V Deep discharge pre-warning at
12.0 V
24 V
Deep discharge protection at
11.7 V
23.4 V
Switch-on voltage
12.5 V
25 V
Cut-off voltage for float charge (Float)
14.1 V
28.2 V
Cut-off voltage/activation for maintenance charge (Boost)
14.4 V / 12.7 V
28.8 V / 25.4 V
Cut-off voltage/activation for equalise charge (Equal) (only with the liquid battery type setting)
15.0 V / 12.2 V
30.0 V / 24.4 V Output voltage (same as battery I)
12 V DC or 24 V DC Maximum output current
20 A
Terminals
for batteries, solar module and load circuit
USB charge socket
5 V, 1500 mA
Other connections
StecaLink bus system (RJ 45)
LEDs
4 (multicolour)
Load circuit
Connections
Display
20 751.792 | Z01 | 1504
Technical data EN
Electronic protection functions
Overcharge/deep discharge protection for the batteries Reverse polarity protection for the solar module1), load circuit
and batteries
Battery overvoltage shutdown Automatic electronic fuse Overtemperature and overload protection Short-circuit protection for load circuit and solar module Overvoltage protection at solar module input Open circuit protection without battery Reverse current protection
The protection functions are activated in the case of simple individual faults. If multiple faults occur simultaneously the protection functions will not be activated and the solar charge controller can be destroyed.
1 )
Only up to an open-circuit voltage UOC < 36 V
751.792 | Z01 | 1504 21
EN Commercial and legal guarantee conditions
9 Commercial and legal guarantee conditions
In accordance with German statutory regulations, there is a 2-year legal guarantee on this product for the customer.
The manufacturer provides a voluntary 5-year commercial guarantee to the specialist dealer from the date of invoice or receipt. The commercial guarantee applies to products purchased and operated in EU countries or Switzerland.
The seller will correct all manufacturing and material faults that occur in the product during the guarantee period and affect the correct functioning of the product. Natural wear and tear does not constitute a malfunction. No guarantee can be offered if the fault can be attributed to third parties, unprofessional installa­tion or commissioning, incorrect or negligent handling, improper transport, excessive loading, use of improper equipment, faulty construction work or improper operation or use. Guarantee claims shall only be accepted if notification of the fault is provided immediately after it is discovered. Guarantee claims are to be directed to the seller. The seller must be informed before guarantee claims are processed. For processing a guarantee claim an exact fault description and the invoice / delivery note must be provided.
The seller can choose to fulfil the guarantee either by repair or replacement. If the product can neither be repaired nor re­placed, or if this does not occur within a suitable period in spite of the specification of an extension period in writing by the cus­tomer, the reduction in value caused by the fault shall be re­placed, or, if this is not sufficiently taking the interests of the end customer into consideration, the contract is cancelled.
Any further claims against the seller based on this guarantee obligation, in particular claims for damages due to lost profit, loss-of-use or indirect damages are excluded, unless liability is obligatory by law.
22 751.792 | Z01 | 1504
DE