State SSE-100 User Manual

COMMERCIAL
The Expert’s Choice
®
500 Lindahl Parkway, Ashland City, TN 37015 • www.stateind.com
Premium Heavy Duty Electric Water Heater
Other Standard Features – Simplified circuitry, color-coded for ease of serviceAnode rod for corrosion protectionImmersion manual reset high limitBrass drain valveHinged control compartment doorASME T & P relief valve
Optional International Voltages - 380, 415, 575 and 600 volts three-phase available with Y connected elements.
Limited Warranty Outline – If the tank should leak any time during the first three years, under
the terms of the warranty.State Water Heaters will repair or replace the heater; installation, labor, handling and local delivery extra.
– This Outline Is NO
T A Warranty. For complete information, consult
the written warranty or State Water Heaters.
– Warranty does not apply to product installed out-side of the United
States of America or its territorial possessions and Canada.
Meets or exceeds the requirements of ASHRAE/IES-90.1-1999.
ASME Tank Construction – 125 psi working pressure (65 thru 120 gallons), 150 psi working pressure (5 thru 50 gallons).
Foam Insulated – To meet rigorous state codes.
Glass-Lined Tank – Ten tank sizes available; 5 to 120 gallon. Tank interior is coated with glass specifically developed for water heater use. Tank cabinet has a baked enamel finish.
Incoloy Immersion Heaters – Heavy-duty medium watt density elements (three/immersion heater) have incoloy sheathing and prewired leads: provide excellent protection against oxidation and scaling. Input ranges from 3KW to 90KW available (see accompanying chart).
Standard Voltages – 208, 240 and 480 volt single and three phase. Single phase 208 and 240 are convertible to three phase. All 208 and 240 volt at 24KW and below are supplied phase convertible (single to three and vice versa). 277 volt single phase also available. Consult factory for 120 volt power circuit availability.
Terminal Block – To accept copper or aluminum leads (on units with more than one contactor).
Immersion Thermostat – Close differential immersion type thermostat provides the accurate temperature control required for commercial applications (adjustable through a range of 95° to 180°F).
120 Volt Control Circuit – 120 volt control circuit powered by fused transformer.
Magnetic Contactors – Heavy-duty UL rated for 100,000 cycles.
Power Circuit Fusing (120 amp current draw and above) – Meets National Electric Code and UL requirements that water heaters must have internal fusing when current draw exceeds 120 amps.
RECOVERY RATE IN GALLONS PER HOUR* - Temperature Rise ˚F
Standard Btu/ KW Input Hour
30˚ 40˚ 50˚ 60˚ 70˚ 80˚ 90˚ 100˚ 110˚ 120˚ 130˚ 140˚
3 10,239 41 31 24 20 17 15 13 12 11 10 10 9 6 20,478 82 62 49 41 35 31 27 25 22 21 19 18
9 30,717 123 92 74 62 53 46 41 37 34 31 28 26 12 40,956 164 123 98 82 70 61 55 49 45 41 38 35 15 51,195 205 154 123 102 88 77 68 61 56 51 47 44 18 61,434 246 184 148 123 105 92 82 74 67 62 57 53 24 81,912 328 246 197 164 140 123 109 98 90 82 76 70 30 102,390 410 308 246 205 176 154 137 123 112 103 95 88 36 122,868 492 369 295 246 211 184 164 148 134 123 113 105 45 153,585 615 461 369 307 263 230 205 184 168 154 142 132 54 184,302 738 554 443 359 316 277 246 221 201 185 170 158 60** 204,780 819 615 492 410 351 307 273 246 223 205 189 176 75** 255,975 1025 768 615 512 439 384 341 307 279 256 236 219 90** 307,170 1229 922 738 615 527 461 410 369 335 307 284 263
*Figured at 1 KW (3413 Btu) = 4.1 gallons at 100˚F temperature rise. **Available on 50 gallon models or larger. To determine recovery rate per minute, divide recovery rate per hour by 60. NSF ratings may be obtained by multiplying above figures by 0.98.
RECOVERY RATES
Optional Equipment & Construction
Silicon Bronze Tank – Available for deionized water.
Stainless Steel Tank – Available for deionized water.
150 or 160 PSI Working Pressure – Available when required. Must be specified at time of order.
Handhole Cleanout – 4˝ x 6˝ size.
Combination Temperature/Pressure Gauge – Dial type combination gauge (shipped loose).
Control Options:
Low Water Cutoff – Probe type electric low water cutoff prevents energizing of elements in the event of low water condition.
Override Switches – A simple form of load control allows all or part of unit input to be controlled manually. Up to one override switch per contactor is available.
Indicating/Pilot Lights – For indicating element operation and/or switch closure. Up to one indicating light available for each switch and/or contactor is available.
Thermostat Step – The simplest form of modulation. Allows elements to be stepped on in groups or individually by specifying additional thermostats (up to 1 per contactor).
Premium Heavy Duty Electric Water Heater
COMMERCIAL
The Expert’s Choice
®
500 Lindahl Parkway, Ashland City, TN 37015 • www.stateind.com
Control Options Continued:
Sequencer – Two or three step time delay sequencer provides for stepping of elements in groups or individually (maximum of 1 step per contactor).
Modulating Step – Solid state electronic control device that modulates input to match load through progressive sequencing of steps (up to 3 steps with maximum of 1 per contactor).
Time Clock – Seven day clock may be programmed for up to 14 on/off operations per week. Skip a day feature allows for weekend shutdown.
Immersion Auto Reset High Limit – Adjustable automatic reset type. Provides additional protection against high temperature conditions.
Safety Door Interlock – Prevents openings of control panel door when heater power supply is energized. NOTE: Once door is open, the heater may be energized if necessary for service diagnosis.
Pressure Limit Switches – Both high and low pressure limit switches available.
Power Circuit Fusing – Sub-divides internal circuitry with maximum of 60 amp fuses. Supplied as standard when required by NEC and UL.
Alarm Horn – Horns may be furnished to warn of any condition in the heater for which sensors have been specified.