MANUF ACTURED
SCOUT
HOUSING
Standard Vent Gas Water Heaters
Complies with HUD Standards for Manufactured Housing Installation. Design-Certified by CSA International -
Meets the Federal Energy Efficiency Standards effective January 20, 2004, according to the National Appliance Energy Conservation Act (NAECA) of 1992.
Gas Control Is Convertible for Natural and Propane Gas -
For flexibility to meet the varying needs of Manufactured Housing installations.
Side-Mounted 3/4” Cold Water Inlet - For ease of installation
when cold water supply originates below the structure. Top-mounted 3/4" hot water outlet.
RESIDENTIAL
Models Packaged with Bottom Intake Air Vent -
To draw all combustion make-up air from outside the structure.
Green Choice® Eco-Friendly Gas Burner - Patented design reduces NOx
emissions by up to 33% and complies with Air Quality Management Districts with similar requirements for low NOx emissions.
Glass-Lined Tank - Protects the tank from corrosion.
Anode Rod - Maximizes tank life.
CSA Certified and ASME Rated T&P Relief Valve
Maximum Hydrostatic Working Pressure 150 PSI
1-Year Limited Tank Warranty
®
Low Lead Compliant
For more information on Scout® contact: State Water Heaters 500 Tennessee Waltz Parkway, Ashland City, TN 37015
800-365-0024 Toll-free www.statewaterheaters.com
SMGSS00108 Revised August 2010
MANUF ACTURED
SCOUT
HOUSING
Standard Vent Gas Water Heaters
RESIDENTIAL
MODEL
NUMBER
STANDARD-VENT MODELS
SCI 30 YOMT
SCI 40 YOMT
Recoveries are rounded to nearest gallon.
MODEL PEAK ENERGY GAL. BTU INPUT RECOVERY R DIMENSIONS IN INCHES APPROX.
NUMBER DEMAND FACTOR CAP. PER HOUR 90°F RISE VALUE SHIPPING
SERIES
SCI 30 YOMT 54 0.61 30 350000 31 16 59-1/2 56 18 15 16-3/4 51-1/4 3 125
SCI 40 YOMT 63 0.59 40 30,000 31 16 60 56-1/2 20 15 20-3/4 51-1/4 3 150
200
200
OUTPUT NATURAL/ GALLONS A B C D E F DRAFT WEIGHT
(1st Hour PROPANE HOOD (LBS.)
Rating OUTLET
Gallons)
62
57
35,500/32,000
35,500/35,5003636
8861-1/2
61-3/4
58
58-1/4
16
13-1/4
18
13-1/4
14-1/4
14-1/4
51-3/4
51-3/4
3-4
3-4
ANODE ROD
HOT
®
Low Lead Compliant
CONNECTION 3/4” FEMALE CONNECTION
PLUG ON 30 & 40 GALLON COLD INLET ON 50 GALLON
T&P VALVE
For complete information on limited warranties, consult written warranty, or contact the State Customer Care Center, 1-800-365-0024.
State Industries, Inc. reserves the right to make product changes or improvements without prior notice.
For more information on Scout contact: State Water Heaters 500 Tennessee Waltz Parkway, Ashland City, TN 37015
800-365-0024 Toll-free www.statewaterheaters.com
SMGSS00108 Revised August 2010
COLD CONNECTION 3/4” FEMALE CONNECTION
G
GAS CONNECTOR
1/2” FEMALE
Standard Vent Models