Star Manufacturing 824T-LP, 824TS-LP, 824TSCHS-LP, 836M-LP, 836T-LP Operation Manual

...
Page 1
Star Manufacturing International Inc.
10 Sunnen Drive St. Louis, MO 63143
Phone: (314) 781-2777 Fax: (314) 781-2714
2M-Z7924 Rev. A 3/15/2006
and
Operating
Instructions
ULTRA-MAX GAS GRIDDLE
MODELS
824M-LP 824T-LP 824TS-LP 824TSCHS-LP 836M-LP 836T-LP 836TS-LP 836TSCHS-LP 848M-LP 848T-LP 848TS-LP 848TSCHS-LP 860M-LP 860T-LP 860TS-LP 860TSCHS-LP 872M-LP 872T-LP 872TS-LP 872TSCHS-LP
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
FOR YOUR SAFETY: Do not store or use gasoline or other fl ammable vapors or liquids in the vicinity of this or any other appliance.
WARNING: This appliance shall be installed in accordance with current regulations and used only in well-ventilated space. Refer to instructions before installing and using this appliance.
In addition, there should be posted, in a prominent location, detailed instructions to be followed in the event the operator smells gas. Obtain the instructions from the local gas supplier.
1
Page 2
SAFETY SYMBOL
Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
Star reserves the right to change specifi cations and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the specifi cations contained in this sheet are subject to change without notice. While Star Manufacturing exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifi cations. By using the information provided, the user assumes all risks in connection with such use.
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when you call to
ensure a faster service.
Model No.
Serial No.
Voltage
Purchase Date
Authorized Service Agent
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com E-mail Service@star-mfg.com Telephone: (800) 807-9054 Local (314) 781-2777
The Star Service Help Desk
Business 8:00 am to 4:30 p.m. Central Standard Time Hours:
Telephone: (800) 807-9054 Local (314) 781-2777
Fax: (800) 396-2677 Local (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com Warranty@star-mfg.com
Website: www.star-mfg.com
Mailing Address: Star Manufacturing International Inc.
10 Sunnen Drive St. Louis, MO 63143 U.S.A
2
2
Page 3
SPECIFICATIONS
824M-LP
Type: Manual Valve
2 Controls, 60,000 BTUH, 573 sq. in. (3697 sq. cm) Grid Area Approximate Weight: Installed - 214 Lb s (97.0 kg), shipping - 244 Lbs (110.6 kg) Dimensions: 24" - Width, 32 3/8" - Depth, 18" - Height (61 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
836M-LP
Type: Manual Valve
3 Controls, 90,000 BTUH, 860 sq. in. (5545 sq. cm) Grid Area Approximate Weight: Installed - 321 Lbs (145.4 kg), shipping - 366 Lbs (165.8 kg) Dimensions: 36" - Width, 32 3/8" - Depth, 18" - Height (91.4 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
848M-LP
Type: Manual Valve
4 Controls, 120,000 BTUH, 1146 sq. in. (7394 sq. cm) Grid Area Approximate Weight: Installed - 428 Lbs (193.9 kg), shipping - 488 Lbs (221.1 kg) Dimensions: 48" - Width, 32 3/8" - Depth, 18" - Height (122 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
860M-LP
Type: Manual Valve
5 Controls, 150,000 BTUH, 1433 sq. in. (9242 sq. cm) Grid Area Approximate Weight: Installed - 535 Lbs (242.4 kg), shipping - 610 Lbs (276.4 kg) Dimensions: 60" - Width, 32 3/8" - Depth, 18" - Height (152.4 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
872M-LP
Type: Manual Valve
6 Controls, 180,000 BTUH, 1719 sq. in. (11091 sq. cm) Grid Area Approximate Weight: Installed - 642 Lbs (290.9 kg), shipping - 732 Lbs (331.7 kg) Dimensions: 72" - Width, 32 3/8" - Depth, 18" - Height (182.9 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
824T-LP
Type: Throttling Control
2 Controls, 60,000 BTUH, 573 sq. in. (3697 sq. cm) Grid Area Approximate Weight: Installed - 220 Lb s (99.7 kg), shipping - 246 Lbs (111.5 kg) Dimensions: 24" - Width, 32 3/8" - Depth, 18" - Height (61 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
836T-LP
Type: Throttling Control
3 Controls, 90,000 BTUH, 860 sq. in. (5545 sq. cm) Grid Area Approximate Weight: Installed - 330 Lbs (149.5 kg), shipping - 369 Lbs (167.2 kg) Dimensions: 36" - Width, 32 3/8" - Depth, 18" - Height (91.4 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
848T-LP
Type: Throttling Control
4 Controls, 120,000 BTUH, 1146 sq. in. (7394 sq. cm) Grid Area Approximate Weight: Installed - 440 Lbs (199.4 kg), shipping - 492 Lbs (222.9 kg) Dimensions: 48" - Width, 32 3/8" - Depth, 18" - Height (122 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
3
Page 4
860T-LP
Type: Throttling Control
5 Controls, 150,000 BTUH, 1433 sq. in. (9242 sq. cm) Grid Area Approximate Weight: Installed - 550 Lbs (249.2 kg), shipping - 615 Lbs (278.7 kg) Dimensions: 60" - Width, 32 3/8" - Depth, 18" - Height
(152.4 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
872T-LP
Type: Throttling Control
6 Controls, 180,000 BTUH, 1719 sq. in. (11091 sq. cm) Grid Area Approximate Weight: Installed - 660 Lbs (299.0 kg), shipping - 738 Lbs (334.4 kg) Dimensions: 72" - Width, 32 3/8" - Depth, 18" - Height
(182.9 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
824TS-LP
Type: Snap Action Control With Safety Pilot
2 Controls, 60,000 BTUH, 573 sq. in. (3697 sq. cm) Grid Area Approximate Weight: Installed - 222 Lb s (100.6 kg), shipping - 250 Lbs (113.3 kg) Dimensions: 24" - Width, 32 3/8" - Depth, 18" - Height (61 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
836TS-LP
Type: Snap Action Control With Safety Pilot
3 Controls, 90,000 BTUH, 860 sq. in. (5545 sq. cm) Grid Area Approximate Weight: Installed - 333 Lbs (150.9 kg), shipping - 375 Lbs (169.9 kg) Dimensions: 36" - Width, 32 3/8" - Depth, 18" - Height (91.4 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
848TS-LP
Type:Snap Action Control With Safety Pilot
4 Controls, 120,000 BTUH, 1146 sq. in. (7394 sq. cm) Grid Area Approximate Weight: Installed - 444 Lbs (201.2 kg), shipping - 500 Lbs (226.6 kg) Dimensions: 48" - Width, 32 3/8" - Depth, 18" - Height (122 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
860TS-LP
Type: Snap Action Control With Safety Pilot
5 Controls, 150,000 BTUH, 1433 sq. in. (9242 sq. cm) Grid Area Approximate Weight: Installed - 555 Lbs (251.5 kg), shipping - 625 Lbs (283.2 kg) Dimensions: 60" - Width, 32 3/8" - Depth, 18" - Height (152.4 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
872TS-LP
Type: Snap Action Control With Safety Pilot
6 Controls, 180,000 BTUH, 1719 sq. in. (11091 sq. cm) Grid Area Approximate Weight: Installed - 666 Lbs (301.8 kg), shipping - 750 Lbs (339.8 kg) Dimensions: 72" - Width, 32 3/8" - Depth, 18" - Height
(182.9 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
824TSCHS-LP
Type: Snap Action With Safety Pilot and Chrome Plate 2 Controls, 60,000 BTUH, 573 sq. in. (3697 sq. cm) Grid Area Approximate Weight: Installed - 222 Lb s (100.6 kg), shipping - 250 Lbs (113.3 kg) Dimensions: 24" - Width, 32 3/8" - Depth, 18" - Height (61 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
4
Page 5
836TSCHS-LP
Type: Snap Action Control With Safety Pilot and Chrome Plate
3 Controls, 90,000 BTUH, 860 sq. in. (5545 sq. cm) Grid Area Approximate Weight: Installed - 333 Lbs (150.9 kg), shipping - 375 Lbs (169.9 kg) Dimensions: 36" - Width, 32 3/8" - Depth, 18" - Height (91.4 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
848TSCHS-LP
Type: Snap Action Control With Safety Pilot and Chrome Plate
4 Controls, 120,000 BTUH, 1146 sq. in. (7394 sq. cm) Grid Area Approximate Weight: Installed - 444 Lbs (201.2 kg), shipping - 500 Lbs (226.6 kg) Dimensions: 48" - Width, 32 3/8" - Depth, 18" - Height
(122 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
860TSCHS-LP
Type: Snap Action Control With Safety Pilot and Chrome Plate
5 Controls, 150,000 BTUH, 1433 sq. in. (9242 sq. cm) Grid Area Approximate Weight: Installed - 555 Lbs (251.5 kg), shipping - 625 Lbs (283.2 kg) Dimensions: 60" - Width, 32 3/8" - Depth, 18" - Height
(152.4 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
872TSCHS-LP
Type: Snap Action Control With Safety Pilot and Chrome Plate
6 Controls, 180,000 BTUH, 1719 sq. in. (11091 sq. cm) Grid Area Approximate Weight: Installed - 666 Lbs (301.8 kg), shipping - 750 Lbs (339.8 kg) Dimensions: 72" - Width, 32 3/8" - Depth, 18" - Height (182.9 cm - Width, 82.2 cm - Depth, 45.7 cm - Height)
5
Page 6
GENERAL INSTALLATION DATA
NOTICE
CAUTION
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations.
Ultra-Max series griddles are equipped for use on either natural or propane gas. This unit is shipped for propane gas and can easily be converted to natural.
See Natural Gas - Conversion.
-IMPORTANT-
Be sure to remove all paper protection and packing material from unit prior to lighting. Remove the protective plastic from the griddle plate and thoroughly clean the unit's exterior surfaces.
KEEP THE APPLIANCE AREA FREE AND CLEAR FROM COMBUSTIBLES! For use on
non-combustible countertops only. Combustible and non-combustible material must be at least 48" (120cm) from the top of the appliance and at least 6" (16cm) from the sides and back. Adequate clearance should also be provided for proper operation and servicing.
The installation of the Appliance must conform to the NATIONAL FUEL GAS CODE "ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/ CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2 PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.
When this appliance is installed with casters, it must be installed with the casters supplied, a connector complying with either ANSI Z21.69 or CAN/CGA-6.16 and a quick-disconnect device complying with either ANSI Z21.41 or CAN1-6.9. It must also be installed with restraining means to guard against transmission of strain to the connector.
For your protection, we recommend a qualifi ed installing agency install this appliance. They should be familiar with gas installations and your local gas requirements. In any case, your gas company should be called to approve the fi nal
installation.
This appliance, its pressure regulator and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG. This appliance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 PSIG.
EXHAUST CANOPY
Griddles inherently create a good deal of heat and smoke and should be installed under an effi cient exhaust hood with fl ame proof fi lters. A vertical distance of not less than 48" shall be provided between the top of the appliance and fi lters or any other combustible material. Exhaust installation must conform to local codes.
AIR SUPPLY
Provisions for adequate air supply must be provided.
CAUTION
AIR INTAKES IN BOTTOM
Air for combustion enters from the bottom of the unit.
Do not obstruct this area.
6
Page 7
LEVELING UNIT
This griddle is supplied with 4 feet or fl oor stand legs which must be screwed into the body. Unit must be level. Level unit by adjusting the (4) feet which have an adjustment of 1-3/4" for accurate and perfect line-up with other units.
CAUTION
DO NOT INSTALL WITHOUT ATTACHING FEET OR SUPPLIED STAND LEGS AND SHELF - DO NOT REMOVE FEET.
Caster Kits: Casters can be used with fl oor stand models or optional equipment stand. For installation, carefully mark and cut off from the bottom of each leg using a straight cutting saw and de-burr the inside tube wall prior to installing the caster. Cut leg should measure 19" tube length, not overall length. Casters add about 6-1/4" of height to the unit. Be sure to use approved strain relief means for protecting gas line connection. If an appliance is equipped with casters and is gas connected with a quick connect coupling, all personnel must be aware that there is a restraint on the appliance and if disconnected for service or cleaning it must be reconnected as originally installed prior to use.
7
Page 8
GAS PIPING
Gas piping shall be of such size and so installed as to provide a supply of gas suffi cient to meet the full gas input of the appliance. If the appliance is to be connected to existing piping, it shall be checked to determine if it has adequate capacity. Joint compound shall be used sparingly and only on the male threads of the pipe joints. Such compounds shall be resistant to the action of L.P. gases. WARNING: Any loose dirt or metal particles which are allowed to enter the gas lines on this appliance will damage the valve and affect its operation. When installing this appliance, all pipe
and fi ttings must be free from all internal loose dirt.
GAS PRESSURE REGULATOR
A convertible pressure regulator is provided with each griddle. It should be connected to the inlet pipe at the rear of the unit. The gas supply is then connected to it. The supply pressure to the regulator is not to exceed 1/2 psig. This unit is shipped for use with propane
gas with 10" water column manifold pressure.
MANUAL SHUT OFF VALVE
A manual shut off valve should be installed upstream from the manifold and within six feet of the griddle.
CHECKING FOR GAS LEAKS
Check entire piping system for leaks. Soap and water solution or other material acceptable for the purpose, shall be used in locating gas leakage.
CAUTION
Matches, candle fl ame or other sources of ignition shall not be used for locating gas leaks.
LIGHTING INSTRUCTIONS
When the griddle is fi rst lit, it will smoke until the preservative oils and impurities are burned off. The griddles are equipped with standing pilots and should
be lit immediately after the gas is turned on.
MANUAL VALVE AND THROTTLING CONTROL MODELS
1. Turn off the main valve to the unit and wait 5 minutes to clear gas.
2. Turn off all knobs and pilot valves.
3. Turn on main valve to unit and light all pilots.
4. Turn burner knobs to desired position.
5. To turn burners off, turn knobs to off.
CONNECTING GAS SUPPLY LINE
The gas inlet of the griddle is sealed at the factory to prevent entry of dirt. Do not remove this seal until the
actual connection is made to the gas supply line.
NATURAL GAS - CONVERSION
This griddle is equipped with fi xed orifi ce hoods and is shipped from the factory for use with propane gas. To convert to natural gas install the orifi ce hoods located
behind the front panel as follows:
1. Remove the front panel by removing the screws located on the front and bottom.
2. Remove the burner mounting screws in the center of the combustion chamber access covers.
3. Slide the burners back off the orifi ce hoods.
4. Remove the propane gas orifi ce hoods and install the natural orifi ce hoods.
5. Slide the burners back over the orifi ce hoods and reinstall the burner mounting screws.
6. Reinstall the front panel.
7. Set the pressure regulator to 5" (12.7cm) or 4" (10.2cm) water column by removing the slotted or hex cap from the center of the regulator. Invert the plug and reinstall. The letters "NAT" will now be visible on the plug. Reinstall the cap. An 1/8" pipe plug is located on the manifold for attaching a pressure gauge.
SNAP ACTION THERMOSTAT AND CHROME SURFACE MODELS
1. Turn off the main valve to the unit and wait 5 minutes to clear gas.
2. Turn off power switch and turn thermostats to lowest setting.
3. Turn on the main valve.
4. Depress and hold safety pilot reset button. Light pilot. Hold reset button for 60 seconds or until pilot stays lit. Repeat for all pilots.
5. Turn on power switch and set thermostats to desired position.
6. To turn burners off, turn off power switch.
8
Page 9
PILOT FLAME ADJUSTMENT
The griddles are equipped with standing pilots and should be lit immediately after the gas is turned on.
MANUAL VALVE AND THROTTLING CONTROL MODELS
Adjust the fl ame as low as possible while still providing immediate burner ignition when the control knob is turned to high.
SNAP ACTION THERMOSTAT AND CHROME SURFACE MODELS
Adjust the pilot so approximately 3/8" of the thermocouple tip is surrounded by the pilot
fl ame.
BURNER AIR SHUTTER ADJUSTMENT
The burner air shutter has a locking screw on the bottom side of the venturi. Loosen this screw to make any adjustment and tighten the screw to lock the air shutter in place after adjustment is complete. Any adjustment must be made when the burner is at full input before the control temperature setting has been satisfi ed.
1. Turn the control knob to the highest position and observe the burner fl ame.
2. Slowly decrease the air shutter opening until the fl ame is a soft blue with yellow tips, then increase the opening until the yellow tips disappear and the fl ame is a hard blue.
3. Do not open the shutter to a point where the fl ame is unstable or lifting from the burner surface. The fl ame must be steady and even across the entire
burner.
BYPASS ADJUSTMENT ON THROTTLING CONTROL MODELS ONLY
Throttling control models have a minimum fl ame setting that provides a steady uniform fl ame across the burner when the control heat setting has been satisfi ed.
1. Set the control at the maximum setting and wait for the burner fl ame to throttle back.
2. Turn the dial to the 200 degree setting. A small steady fl ame should be visible on all the burner ports. This fl ame should be approximately 1/8" high.
3. An adjustment screw is located either on the front or side of the control housing.
4. Turn clockwise to decrease the fl ame height; turn counterclockwise to increase the fl ame.
ELECTRICAL CONNECTION FOR SNAP ACTION AND CHROME SURFACE MODELS ONLY
Snap action and chrome surface griddles are equipped with a three-prong grounding plug. The unit is designed for use on a 120 volt 15 amp 50/60 cycle AC single-phase circuit only. For protection against electrical shock, the unit must be plugged directly into a properly grounded three-prong receptacle. Do not
cut or remove the grounding prong from this plug.
CAUTION
Do not connect to any other type of current or serious damage will occur.
OPERATING INSTRUCTIONS
SEASONING THE GRIDDLE HEATING SURFACE (NON-CHROME SURFACES)
Clean the griddle surface thoroughly. After the griddle has been thoroughly cleaned, it should be seasoned to prevent food from sticking. Before using and after each thorough scouring, season the griddle heating surface in the following manner:
1. Turn the temperature control dial to 350°F (174.0°C).
2. Using a clean cloth, not a spatula, spread a thin fi lm of cooking oil or shortening over the griddle cooking surface. This fi lm should remain on the hot griddle surface 1/2 hour.
3. Remove excess shortening and wipe clean.
4. Apply another fi lm of cooking oil over the hot cooking area for another 1/2 hour, and again remove excess shortening and wipe clean. The
griddle surface should now be ready for use.
Even with careful seasoning food may, to some extent, stick to the griddle cooking surface until griddle plate is "broken in."
COOKING
Set the dial knob to the setting desired. After a 30 minute (minimum) preheating period, the griddle will automatically maintain the selected temperature.
9
Page 10
GRIDDLE CARE (NON-CHROME SURFACES)
It takes very little time and effort to keep the griddle attractive and performing at top effi ciency. If grease is permitted to accumulate, it will form a gummy cake and then carbonize into a hard substance which is extremely diffi cult to remove. To prevent this condition, the following suggestions for cleanliness should be followed:
1. After each use, scrape the griddle with a scraper or fl exible spatula to remove excess grease and food. A waste drawer is provided for the scrapings. If there is an accumulation of burned-on grease and food, the griddle should be thoroughly scoured and reseasoned. Use pumice or griddle stone while the griddle is warm. Do not use steel wool because of the danger of steel slivers getting into the food.
2. Use a clean cloth and good non-abrasive cleaner to clean the stainless steel body of the griddle. Wipe the control panel front with a soft cloth.
3. At least once a day, remove the waste drawer and wash in the same way as an ordinary cooking utensil. The drawer is removed by pulling forward
and out.
GRIDDLE CARE (CHROME SURFACES)
(Chrome surface griddles are marked with "CHS" at the end of the model number designation on the nameplate.) It takes very little time and effort to keep this Industrial Chrome griddle surface sparkling clean and performing at top effi ciency. DO NOT allow grease to accumulate as it will carbonize and become diffi cult to remove. To prevent this condition, the following cleaning suggestions should be followed:
1. Remove excess oil and food regularly with a 4" (100mm) wide razor sharp type scraper and wipe surface with a damp cloth if desired.
2. Following the scraping, for end of the day cleaning, a damp cloth and a non-silicated, non-abrasive, non-chlorinated cleaner such as Bon-Ami may be used to wipe surface clean, followed by wiping with clean wet cloth.
3. Follow steps 2 and 3 from Griddle Care (Non­Chrome Surfaces).
CAUTION
1. Never use pumice, griddle stones, or abrasives
on the surface.
2. Never strike the griddle surface with a sharp instrument or spatula edge.
3. Never use steel wool.
4. Never use commercial liquid grill cleaner on the griddle surface.
5. Abusing the surface voids the warranty.
WASTE DRAWER
A waste drawer is located at the front and can be removed from the front for cleaning by pulling drawer forward. This drawer should be checked and emptied
when necessary or at least once per day.
CAUTION
EXERCISE EXTREME CARE IN HANDLING THE WASTE DRAWER CONTAINING HOT GREASE.
OVERNIGHT SHUTDOWN
MANUAL VALVE AND THROTTLING CONTROL MODELS
Turn knobs to the off position to turn burners off.
SNAP ACTION AND CHROME SURFACE MODELS
Turn knobs to the lowest setting and turn power switch off.
10
Page 11
CHROME GRIDDLE SURFACE LIMITED WARRANTY EXCLUSIONS
Your chrome griddle has been designed to give you many years of cooking reliability and requires minimum maintenance to keep the chrome surface in its original condition. All chrome griddle surfaces are warranted for a period of 5 years against manufacturing defects to the original owner from the date of installation. This limited warranty is void if it is determined by Star Manufacturing International Incorporated or one of its authorized representatives that the chrome surface has been misused or abused or subjected to the following situations:
1. Improperly installed.
2. By-pass adjustments not set properly on gas units allowing the appliance to overheat and discolor the chrome surface. (See by-pass adjustment section.)
3. The misuse of any instrument or tool which scratches or makes indentations in the surface which could cause the surface to peel, fl ake, or chip off.
4. The use of any chemical or abrasive cleaning solution, griddle brick, stone, screen or other cleaning products which could damage and affect the performance of the chome surface.
5. The neglect of daily routine maintenance to the chrome surface.
11
Page 12
Visit our Website at:
This unit has been tested for proper operation before leaving our plant to insure delivery of your unit in perfect condition. However, there are instances in which the unit may be damaged in transit. In the event you discover any type of damage to your product upon receipt, you must immediately contact the transportation company who delivered the item to you and initiate your claim with same. If this procedure is not followed, it may affect the warranty status of the unit.
All workmanship and material in Star products have a one (1) year limited warranty on parts & labor in the United States and Canada. Such warranty is limited to the original purchaser only and shall be effective from the date the equipment is placed in service. Star's obligation under this warranty is limited to the repair of defects without charge, by the factory authorized service agency or one of its sub-agencies. Models that are considered portable (see below) should be taken to the closest Star service agency, transportation prepaid.
www.star-mfg.com Email: service@star-mfg.com
THOROUGHLY INSPECT YOUR UNIT ON ARRIVAL
LIMITED EQUIPMENT WARRANTY
> Star will not assume any responsibility for loss of revenue.
> On all shipments outside the United States and Canada, see International Warranty.
* The warranty period for the JetStar six (6) ounce & Super JetStar eight (8) ounce series popcorn machines is two (2) years.
* The warranty period for the Chrome-Max Griddles is five (5) years on the griddle surface. See detailed warranty provided with unit.
* The warranty period for Teflon/Dura-Tec coatings is one year under normal use and reasonable care. This warranty does not apply if damage occurs to
Teflon/Dura-Tec coatings from improper cleaning, maintenance, use of metallic utensils, or abrasive cleaners. This warranty does not apply to the “non-stick” properties of such materials.
> This warranty does not apply to "Special Products" but to regular catalog items only. Star's warranty on "Special Products" is six (6) months on parts
and ninety (90) days on labor.
> This warranty does not apply to any item that is disassembled or tampered with for any purpose other than repair by a Star Authorized Service Center or
the Service Center's sub-agency.
> This warranty does not apply if damage occurs from improper installation, misuse, wrong voltage, wrong gas or operated contrary to the Installation and
Operating instructions.
> This warranty is not valid on Conveyor Ovens unless a "start-up/check-out" has been performed by a Factory Authorized Technician.
PARTS WARRANTY
Parts that are sold to repair out of warranty equipment are warranted for ninety (90) days. The part only is warranted. Labor to replace the part is chargeable to the customer.
SERVICES NOT COVERED BY WARRANTY
1. Travel time and mileage rendered beyond the 50 mile radius limit
2. Mileage and travel time on portable equipment (see below)
3. Labor to replace such items that can be replaced easily during a daily cleaning routine, ie; removable kettles on fryers, knobs, grease drawers on griddles, etc.
4. Installation of equipment
5. Damages due to improper installation
6. Damages from abuse or misuse
7. Operated contrary to the Operating and Installation Instructions
8. Cleaning of equipment
9. Seasoning of griddle plates
PORTABLE EQUIPMENT
Star will not honor service bills that include travel time and mileage charges for servicing any products considered "Portable" including items listed below. These products should be taken to the Service Agency for repair:
* The Model 510FD Fryer. * The Model J4R, 4 oz. Popcorn Machine. * The Model 518CMA & 526CMA Cheese Melter. * The Model 12MC & 15MC & 18MCP Hot Food Merchandisers. * The Model 12NCPW & 15NCPW Nacho Chip/Popcorn Warmer. * All Hot Dog Equipment except Roller Grills & Drawer Bun Warmers. * All Nacho Cheese Warmers except Model 11WLA Series Nacho Cheese Warmer. * All Condiment Dispensers except the Model HPDE, & SPDE Series Dispenser. * All Specialty Food Warmers except Model 130R, 11RW Series, and 11WSA Series. * All QCS/RCS Series Toasters except Model QCS3 & RCS3 Series.
The foregoing warranty is in lieu of any and all other warranties expressed or implied and constitutes the entire warranty.
FOR ASSISTANCE
Should you need any assistance regarding the Operation or Maintenance of any Star equipment; write, phone, fax or email our Service Department.
In all correspondence mention the Model number and the Serial number of your unit, and the voltage or type of gas you are using.
10 . Voltage conversions 11 . Gas conversions 12 . Pilot light adjustment 13 . Miscellaneous adjustments 14 . Thermostat calibration and by-pass adjustment 15 . Resetting of circuit breakers or safety controls or reset buttons 16 . Replacement of bulbs 17 . Replacement of fuses 18 . Repair of damage created during transit, delivery, &
installation OR created by acts of God
ALL: * Pop-Up Toasters * Butter Dispensers * Pretzel Merchandisers * Pastry Display Cabinets * Nacho Chip Merchandisers * Accessories of any kind * Sneeze Guards * Pizza Ovens * Heat Lamps * Pumps
Part# 2M-4497-2 05/06 RB
12
Page 13
13
Page 14
PARTS LIST March 15, 2006, Rev. A
824-LP Series Gas Griddles
MODEL
Number
Key
Number
1 G5-Z4812 1 FLUE 824M/T/TS/TSCHS 3 G5-824004 1 GRIDDLE PLATE ASSY COMPLETE 824M G5-824005 1 GRIDDLE PLATE ASSY COMPLETE 824T/TS G5-824006 1 GRIDDLE PLATE ASSY COMPLETE 824TSCHS 4 G5-Z4793 2 BULB CLAMP 824T/TS/TSCHS 5 G5-Z4794 2 BULB COVER 824T/TS/TSCHS 6 G5-Z4795 6 BULB SPRING 824T/TS/TSCHS 7 G5-Z4927 2 ORIFICE BRACKET 824M/T/TS/TSCHS 8 2F-Z4613 2 BURNER 824M/T/TS/TSCHS 9 G5-Z4800 1 SIDE BAFFLE RIGHT ALL 824/36/48/60/72 10 2A-Z4614 4 FOOT ALL 824/36/48/60/72 11 G5-824014 1 WASTE DRAWER ASSY ALL 824/836/848 12 G5-Z4897 1 DRAWER GUIDE ALL 824/836/848 13 G5-Z4799 1 PILOT BAFFLE 824TS/TSCHS 14 G5-Z4798 1 BURNER BAFFLE 824M/T 15 G5-Z4900 2 BURNER COVER 824M/T/TS/TSCHS 16 2A-9369 2 ORIFICE FITTING 824M/T/TS/TSCHS 17 2A-Z4930 2 ORIFICE NATURAL 824M/T 2A-Z5542 2 ORIFICE NATURAL 824TS/TSCHS 2A-Z4931 2 ORIFICE PROPANE 824M/T/TS/TSCHS 18 G5-Z4801 1 SIDE BAFFLE LEFT ALL 824/36/48/60/72 19 2M-Z4864 1 CONTROL GRAPHICS PANEL 824TS/TSCHS 20 2R-Z4997 2 KNOB 824M/T 2R-Z8891 2 KNOB 824TS/TSCHS manuf. after 8/05 PS-Z9312 2 KNOB SERVICE KIT 824TS/TSCHS manuf. before 8/05 21 G5-824012 1 CHUTE ASSEMBLY ALL 824/836/848 22 G5-824008 1 FRONT PANEL ASSEMBLY 824M/T 23 G5-824013 1 FRONT PANEL ASSEMBLY 824TS/TSCHS 24 2M-Z4862 1 CONTROL GRAPHICS PANEL 824M 2M-Z4863 1 CONTROL GRAPHICS PANEL 824T 25 G5-824007 1 BODY ASSEMBLY 824M/T/TS/TSCHS 26 VARIOUS 1 NAMEPLATE ALL N/A 2J-Z4686 1 REGULATOR (5” AND 10”) ALL M/T N/A 2J-Z5541 1 REGULATOR (4” AND 10”) ALL TS/TSCHS N/A 2C-Z8547 2 BOLT, KNOB STOP ALL
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
14
Page 15
PARTS LIST Mach 15, 2006, Rev. A
836-LP Series Gas Griddles
MODEL
Number
Key
Number
1 G5-Z4813 1 FLUE 836M/T/TS/TSCHS 2 G5-Z4817 1 FLUE DIVIDER 836M/T/TS/TSCHS 3 G5-836004 1 GRIDDLE PLATE ASSY COMPLETE 836M 3 G5-836005 1 GRIDDLE PLATE ASSY COMPLETE 836T/TS 3 G5-836006 1 GRIDDLE PLATE ASSY COMPLETE 836TSCHS 4 G5-Z4793 3 BULB CLAMP 836T/TS/TSCHS 5 G5-Z4794 3 BULB COVER 836T/TS/TSCHS 6 G5-Z4795 9 BULB SPRING 836T/TS/TSCHS 7 G5-Z4927 3 ORIFICE BRACKET 836M/T/TS/TSCHS 8 2F-Z4613 3 BURNER 836M/T/TS/TSCHS 9 G5-Z4800 1 SIDE BAFFLE RIGHT ALL 824/36/48/60/72 10 2A-Z4614 4 FOOT ALL 824/36/48/60/72 11 G5-824014 1 WASTE DRAWER ASSY ALL 824/836/848 12 G5-Z4897 1 DRAWER GUIDE ALL 824/836/848 13 G5-Z4799 2 PILOT BAFFLE 836TS/TSCHS 14 G5-Z4798 2 BURNER BAFFLE 836M/T 15 G5-Z4900 3 BURNER COVER 836M/T/TS/TSCHS 16 2A-9369 3 ORIFICE FITTING 836M/T/TS/TSCHS 17 2A-Z4930 3 ORIFICE NATURAL 836M/T 17 2A-Z4931 3 ORIFICE PROPANE 836M/T/TS/TSCHS 17 2A-Z5542 3 ORIFICE NATURAL 836TS/TSCHS 18 G5-Z4801 1 SIDE BAFFLE LEFT ALL 824/36/48/60/72 19 2M-Z4867 1 CONTROL GRAPHICS PANEL 836TS/TSCHS 20 2R-Z4997 3 KNOB 836M/T 2R-Z8891 3 KNOB 836TS/TSCHS manuf. after 8/2005 PS-Z9312 3 KNOB SERVICE KIT 836TS/TSCHS manuf. before 8/2005 21 G5-824012 1 CHUTE ASSEMBLY ALL 824/836/848 22 G5-836008 1 FRONT PANEL ASSEMBLY 836M/T 23 G5-836013 1 FRONT PANEL ASSEMBLY 836TS/TSCHS 24 2M-Z4865 1 CONTROL GRAPHICS PANEL 836M 24 2M-Z4866 1 CONTROL GRAPHICS PANEL 836T 25 G5-836007 1 BODY ASSEMBLY 836M/T/TS/TSCHS 26 VARIOUS 1 NAMEPLATE ALL N/A 2J-Z4686 1 REGULATOR (5” AND 10”) ALL M/T N/A 2J-Z5541 1 REGULATOR (4” AND 10”) ALL TS/TSCHS
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
15
Page 16
PARTS LIST March 15, 2006, Rev. A
848-LP Series Gas Griddles
MODEL
Number
Key
Number
1 G5-Z4814 1 FLUE 848M/T/TS/TSCHS 2 G5-Z4817 1 FLUE DIVIDER 848M/T/TS/TSCHS 3 G5-848004 1 GRIDDLE PLATE ASSY COMPLETE 848M 3 G5-848005 1 GRIDDLE PLATE ASSY COMPLETE 848T/TS 3 G5-848006 1 GRIDDLE PLATE ASSY COMPLETE 848TSCHS 4 G5-Z4793 4 BULB CLAMP 848T/TS/TSCHS 5 G5-Z4794 4 BULB COVER 848T/TS/TSCHS 6 G5-Z4795 12 BULB SPRING 848T/TS/TSCHS 7 G5-Z4928 4 ORIFICE BRACKET 848M/T/TS/TSCHS 8 2F-Z4613 4 BURNER 848M/T/TS/TSCHS 9 G5-Z4800 1 SIDE BAFFLE RIGHT ALL 824/36/48/60/72 10 2A-Z4614 4 FOOT ALL 824/36/48/60/72 11 G5-824014 1 WASTE DRAWER ASSY ALL 824/836/848 11 G5-824014 2 WASTE DRAWER ASSY ALL 860/872 12 G5-Z4897 1 DRAWER GUIDE ALL 824/836/848 12 G5-Z4897 2 DRAWER GUIDE ALL 860/872 13 G5-Z4799 2 PILOT BAFFLE 848TS/TSCHS 14 G5-Z4798 3 BURNER BAFFLE 848M/T 14 G5-Z4798 1 BURNER BAFFLE 848TS/TSCHS 15 G5-Z4900 4 BURNER COVER 848M/T/TS/TSCHS 16 2A-9369 4 ORIFICE FITTING 848M/T/TS/TSCHS 17 2A-Z4930 4 ORIFICE NATURAL 848M/T 17 2A-Z4931 4 ORIFICE PROPANE 848M/T/TS/TSCHS 17 2A-Z5542 4 ORIFICE NATURAL 848TS/TSCHS 18 G5-Z4801 1 SIDE BAFFLE LEFT ALL 824/36/48/60/72 19 2M-Z4870 1 CONTROL GRAPHICS PANEL 848TS/TSCHS 20 2R-Z4997 4 KNOB 848M/T 2R-Z8891 4 KNOB 848TS/TSCHS manuf. after 8/2005 PS-Z9312 4 KNOB SERVICE KIT 848TS/TSCHS manuf. before 8/2005 21 G5-824012 1 CHUTE ASSEMBLY ALL 824/836/848 22 G5-848008 1 FRONT PANEL ASSEMBLY 848M/T 23 G5-848013 1 FRONT PANEL ASSEMBLY 848TS/TSCHS 24 2M-Z4868 1 CONTROL GRAPHICS PANEL 848M 24 2M-Z4869 1 CONTROL GRAPHICS PANEL 848T 25 G5-848007 1 BODY ASSEMBLY 848M/T/TS/TSCHS 26 VARIOUS 1 NAMEPLATE ALL N/A 2J-Z4686 1 REGULATOR (5” AND 10”) ALL M/T N/A 2J-Z5541 1 REGULATOR (4” AND 10”) ALL TS/TSCHS
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
16
Page 17
PARTS LIST March 15, 2006, Rev. A
860-LP Series Gas Griddles
MODEL
Number
Key
Number
1 G5-Z4815 1 FLUE 860M/T/TS/TSCHS 2 G5-Z4817 1 FLUE DIVIDER 860M/T/TS/TSCHS 3 G5-860004 1 GRIDDLE PLATE ASSY COMPLETE 860M 3 G5-860005 1 GRIDDLE PLATE ASSY COMPLETE 860T/TS 3 G5-860006 1 GRIDDLE PLATE ASSY COMPLETE 860TSCHS 4 G5-Z4793 5 BULB CLAMP 860T/TS/TSCHS 5 G5-Z4794 5 BULB COVER 860T/TS/TSCHS 6 G5-Z4795 15 BULB SPRING 860T/TS/TSCHS 7 G5-Z4929 5 ORIFICE BRACKET 860M/T/TS/TSCHS 8 2F-Z4613 5 BURNER 860M/T/TS/TSCHS 9 G5-Z4800 1 SIDE BAFFLE RIGHT ALL 824/36/48/60/72 10 2A-Z4614 4 FOOT ALL 824/36/48/60/72 11 G5-824014 2 WASTE DRAWER ASSY ALL 860/872 12 G5-Z4897 2 DRAWER GUIDE ALL 860/872 13 G5-Z4799 3 PILOT BAFFLE 860TS/TSCHS 14 G5-Z4798 4 BURNER BAFFLE 860M/T 14 G5-Z4798 1 BURNER BAFFLE 860TS/TSCHS 15 G5-Z4900 5 BURNER COVER 860M/T/TS/TSCHS 16 2A-9369 5 ORIFICE FITTING 860M/T/TS/TSCHS 17 2A-Z4930 5 ORIFICE NATURAL 860M/T 17 2A-Z4931 5 ORIFICE PROPANE 860M/T/TS/TSCHS 17 2A-Z5542 5 ORIFICE NATURAL 860TS/TSCHS 18 G5-Z4801 1 SIDE BAFFLE LEFT ALL 824/36/48/60/72 19 2M-Z4873 1 CONTROL GRAPHICS PANEL 860TS/TSCHS 20 2R-Z4997 5 KNOB 860M/T 2R-Z8891 5 KNOB 860TS/TSCHS manuf. after 8/2005 PS-Z9312 5 KNOB SERVICE KIT 860TS/TSCHS manuf. before 8/2005 21 G5-824012 2 CHUTE ASSEMBLY ALL 860/872 22 G5-860008 1 FRONT PANEL ASSEMBLY 860M/T 23 G5-860013 1 FRONT PANEL ASSEMBLY 860TS/TSCHS 24 2M-Z4871 1 CONTROL GRAPHICS PANEL 860M 24 2M-Z4872 1 CONTROL GRAPHICS PANEL 860T 25 G5-860007 1 BODY ASSEMBLY 860M/T/TS/TSCHS 26 VARIOUS 1 NAMEPLATE ALL N/A 2J-Z4686 1 REGULATOR (5” AND 10”) ALL M/T N/A 2J-Z5541 1 REGULATOR (4” AND 10”) ALL TS/TSCHS
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
17
Page 18
PARTS LIST March 15, 2006, Rev. A
872-LP Series Gas Griddles
MODEL
Number
Key
Number
1 G5-Z4816 1 FLUE 872M/T/TS/TSCHS 2 G5-Z4817 2 FLUE DIVIDER 872M/T/TS/TSCHS 3 G5-824006 1 GRIDDLE PLATE ASSY COMPLETE 872TSCHS 3 G5-872004 1 GRIDDLE PLATE ASSY COMPLETE 872M 3 G5-872005 1 GRIDDLE PLATE ASSY COMPLETE 872T/TS 4 G5-Z4793 6 BULB CLAMP 872T/TS/TSCHS 5 G5-Z4794 6 BULB COVER 872T/TS/TSCHS 6 G5-Z4795 18 BULB SPRING 872T/TS/TSCHS 7 G5-Z4930 6 ORIFICE BRACKET 872M/T/TS/TSCHS 8 2F-Z4613 6 BURNER 872M/T/TS/TSCHS 9 G5-Z4800 1 SIDE BAFFLE RIGHT ALL 824/36/48/60/72 10 2A-Z4614 4 FOOT ALL 824/36/48/60/72 11 G5-824014 2 WASTE DRAWER ASSY ALL 860/872 12 G5-Z4897 2 DRAWER GUIDE ALL 860/872 13 G5-Z4799 3 PILOT BAFFLE 872TS/TSCHS 14 G5-Z4798 5 BURNER BAFFLE 872M/T 14 G5-Z4798 2 BURNER BAFFLE 872TS/TSCHS 15 G5-Z4900 6 BURNER COVER 872M/T/TS/TSCHS 16 2A-9369 6 ORIFICE FITTING 872M/T/TS/TSCHS 17 2A-Z4930 6 ORIFICE NATURAL 872M/T 17 2A-Z4931 6 ORIFICE PROPANE 872M/T/TS/TSCHS 17 2A-Z5542 6 ORIFICE NATURAL 872TS/TSCHS 18 G5-Z4801 1 SIDE BAFFLE LEFT ALL 824/36/48/60/72 19 2M-Z4876 1 CONTROL GRAPHICS PANEL 872TS/TSCHS 20 2R-Z4997 6 KNOB 872M/T 2R-Z8891 6 KNOB 872TS/TSCHS manuf. after 8/2005 PS-Z9312 6 KNOB SERVICE KIT 872TS/TSCHS manuf. before 8/2005 21 G5-824012 2 CHUTE ASSEMBLY ALL 860/872 22 G5-872008 1 FRONT PANEL ASSEMBLY 872M/T 23 G5-872013 1 FRONT PANEL ASSEMBLY 872TS/TSCHS 24 2M-Z4874 1 CONTROL GRAPHICS PANEL 872M 24 2M-Z4875 1 CONTROL GRAPHICS PANEL 872T 25 G5-872007 1 BODY ASSEMBLY 872M/T/TS/TSCHS 26 VARIOUS 1 NAMEPLATE ALL N/A 2J-Z4686 1 REGULATOR (5” AND 10”) ALL M/T N/A 2J-Z5541 1 REGULATOR (4” AND 10”) ALL TS/TSCHS
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
18
Page 19
192021
Page 20
Page 21
PARTS LIST March 15, 2006, Rev. A
800M and 800T Series Gas Griddles
MODEL
Key
Number
1 2K-Z4901 1 MANIFOLD 824M/T 2K-Z4902 1 MANIFOLD 836M/T 2K-Z4903 1 MANIFOLD 848M/T 2K-Z4904 1 MANIFOLD 860M/T 2K-Z4905 1 MANIFOLD 872M/T 2 2K-Z4921 2 BURNER FLEX TUBE 824M/T 3 BURNER FLEX TUBE 836M/T 4 BURNER FLEX TUBE 848M/T 5 BURNER FLEX TUBE 860M/T 6 BURNER FLEX TUBE 872M/T 3 2P-1453 1 PIPE PLUG ALL M/T 4 2V-Z4821 2 PILOT BURNER 824T 3 PILOT BURNER 836T 4 PILOT BURNER 848T 5 PILOT BURNER 860T 6 PILOT BURNER 872T 2V-Z4906 2 PILOT BURNER 824M 3 PILOT BURNER 836M 4 PILOT BURNER 848M 5 PILOT BURNER 860M 6 PILOT BURNER 872M 5 2V-6671 2 PILOT VALVE 824M/T 3 PILOT VALVE 836M/T 4 PILOT VALVE 848M/T 5 PILOT VALVE 860M/T 6 PILOT VALVE 872M/T 6 2T-Z4823 2 THROTTLING CONTROL 824T 3 THROTTLING CONTROL 836T 4 THROTTLING CONTROL 848T 5 THROTTLING CONTROL 860T 6 THROTTLING CONTROL 872T 2V-Y8832 2 MANUAL VALVE 824M 3 MANUAL VALVE 836M 4 MANUAL VALVE 848M 5 MANUAL VALVE 860M 6 MANUAL VALVE 872M 7 2A-Z0790 2 FITTING 3/8 CC X 3/8-27 824M 3 FITTING 3/8 CC X 3/8-27 836M 4 FITTING 3/8 CC X 3/8-27 848M 5 FITTING 3/8 CC X 3/8-27 860M 6 FITTING 3/8 CC X 3/8-27 872M 2K-Y7111 2 FITTING 3/8 CC X 1/4 MPT 824T 3 FITTING 3/8 CC X 1/4 MPT 836T 4 FITTING 3/8 CC X 1/4 MPT 848T 5 FITTING 3/8 CC X 1/4 MPT 860T 6 FITTING 3/8 CC X 1/4 MPT 872T
Part
Number
Per
Unit
Description and Model Designation
Number
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
Page 22
2223242526
Page 23
Page 24
Page 25
Page 26
Page 27
PARTS LIST March 15, 2006, Rev. A
824TS-LP and 824TSCHS-LP Series
MODEL
Number
Key
Number
1 2K-Z4921 2 BURNER FLEX TUBE 824TS/TSCHS 2 2K-2675 2 FITTING 3/8 CC X 3/8 MPT 824TS/TSCHS 3 2P-1453 1 PIPE PLUG 824TS/TSCHS 4 2K-Y5550 3 NIPPLE 3/8 NPT X 1 1/2 824TS/TSCHS 5 2K-2665 1 ELBOW 3/8 NPT 824TS/TSCHS 6 2J-Z4610 2 SOLENOID VALVE 824TS/TSCHS 7 G5-Z4907 2 MOUNTING BRACKET 824TS/TSCHS 8 G5-824019 1 PILOT BRACKET ASSY 824TS/TSCHS 9 G5-824018 1 FLASH TUBE BRACKET ASSY 824TS/TSCHS 10 2J-Z4608 1 PILOT BURNER 824TS/TSCHS 11 2A-Y2017 1 PILOT ORIFICE 824TS/TSCHS 12 2K-Z4920 1 PILOT TUBE FLEX 824TS/TSCHS 13 2J-Z4609 1 THERMOCOUPLE 824TS/TSCHS 14 2K-Z4617 1 REDUCER BUSHING 824TS/TSCHS 15 2K-Z4616 1 INLET PIPE 824TS/TSCHS 16 2K-Z5033 1 UNION 824TS/TSCHS 17 2K-Z4618 1 NIPPLE 3/4 NPT X 2 1/4 824TS/TSCHS 19 2J-Z4607 1 SAFETY VALVE 824TS/TSCHS 20 2V-6671 1 PILOT VALVE 824TS/TSCHS 21 2K-Y4403 1 CLOSE NIPPLE 3/8 NPT 824TS/TSCHS 22 2K-9688 1 TEE 3/8 NPT 824TS/TSCHS 23 2K-Z4612 1 NIPPLE WITH PRESSURE TAP 824TS/TSCHS 24 2T-Z7440 2 ELEC. THERMOSTAT manufactured after 8/2005 824TS/TSCHS PS-Z9318 2 THERMOSTAT SERVICE KIT manufactured before 8/2005 824TS/TSCHS 25 G5-824015 2 WIRE ASSEMBLY #1 824TS/TSCHS 26 G5-824017 1 WIRE ASSEMBLY 824TS “C” 824TS/TSCHS 27 G5-824016 1 WIRE ASSEMBLY 824TS “L” 824TS/TSCHS 28 2E-Z1858 1 SWITCH 824TS/TSCHS 29 2K-Y2967 1 CORD BUSHING 824TS/TSCHS 30 N2-30409 1 CORD SET 824TS/TSCHS 31 2K-Z4611 1 ELBOW 3/4 NPT 824TS/TSCHS
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
27
Page 28
PARTS LIST March 15, 2006, Rev. A
836TS-LP and 836TSCHS-LP Series
MODEL
Number
Key
Number
1 2K-Z4921 3 BURNER FLEX TUBE 836TS/TSCHS 2 2K-2675 3 FITTING 3/8 CC X 3/8 MPT 836TS/TSCHS 3 2P-1453 1 PIPE PLUG 836TS/TSCHS 4 2K-Y5550 3 NIPPLE 3/8 NPT X 1 1/2 836TS/TSCHS 5 2K-2665 2 ELBOW 3/8 NPT 836TS/TSCHS 6 2J-Z4610 3 SOLENOID VALVE 836TS/TSCHS 7 G5-Z4907 2 MOUNTING BRACKET 836TS/TSCHS 8 G5-824019 2 PILOT BRACKET ASSY 836TS/TSCHS 9 G5-824018 2 FLASH TUBE BRACKET ASSY 836TS/TSCHS 10 2J-Z4608 2 PILOT BURNER 836TS/TSCHS 11 2A-Y2017 2 PILOT ORIFICE 836TS/TSCHS 12 2K-Z4920 2 PILOT TUBE FLEX 836TS/TSCHS 13 2J-Z4609 2 THERMOCOUPLE 836TS/TSCHS 14 2K-Z4617 2 REDUCER BUSHING 836TS/TSCHS 15 2K-Z4616 1 INLET PIPE 836TS/TSCHS 16 2K-Z5033 1 UNION 836TS/TSCHS 17 2K-Z4618 1 NIPPLE 3/4 NPT X 2 1/4 836TS/TSCHS 18 2K-Z5034 1 3/4 NPT TEE 836TS/TSCHS 19 2J-Z4607 2 SAFETY VALVE 836TS/TSCHS 20 2V-6671 2 PILOT VALVE 836TS/TSCHS 21 2K-Y4403 4 CLOSE NIPPLE 3/8 NPT 836TS/TSCHS 22 2K-9688 1 TEE 3/8 NPT 836TS/TSCHS 23 2K-Z4612 1 NIPPLE WITH PRESSURE TAP 836TS/TSCHS 24 2T-Z7440 3 ELEC. THERMOSTAT manufactured after 8/2005 836TS/TSCHS PS-Z9318 3 THERMOSTAT SERVICE KIT manufactured before 8/2005 836TS/TSCHS 25 G5-824015 3 WIRE ASSEMBLY #1 836TS/TSCHS 26 G5-836017 1 WIRE ASSEMBLY 836TS “C” 836TS/TSCHS 27 G5-836016 1 WIRE ASSEMBLY 836TS “L” 836TS/TSCHS 28 2E-Z1858 1 SWITCH 836TS/TSCHS 29 2K-Y2967 1 CORD BUSHING 836TS/TSCHS 30 N2-30409 1 CORD SET 836TS/TSCHS
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
28
Page 29
PARTS LIST March 15, 2006, Rev. A
848TS-LP and 848TSCHS-LP Series
MODEL
Number
Key
Number
1 2K-Z4921 4 BURNER FLEX TUBE 848TS/TSCHS 2 2K-2675 4 FITTING 3/8 CC X 3/8 MPT 848TS/TSCHS 3 2P-1453 2 PIPE PLUG 848TS/TSCHS 4 2K-Y5550 4 NIPPLE 3/8 NPT X 1 1/2 848TS/TSCHS 5 2K-2665 2 ELBOW 3/8 NPT 848TS/TSCHS 6 2J-Z4610 4 SOLENOID VALVE 848TS/TSCHS 7 G5-Z4907 2 MOUNTING BRACKET 848TS/TSCHS 8 G5-824019 2 PILOT BRACKET ASSY 848TS/TSCHS 9 G5-824018 2 FLASH TUBE BRACKET ASSY 848TS/TSCHS 10 2J-Z4608 2 PILOT BURNER 848TS/TSCHS 11 2A-Y2017 2 PILOT ORIFICE 848TS/TSCHS 12 2K-Z4920 2 PILOT TUBE FLEX 848TS/TSCHS 13 2J-Z4609 2 THERMOCOUPLE 848TS/TSCHS 14 2K-Z4617 2 REDUCER BUSHING 848TS/TSCHS 15 2K-Z4616 1 INLET PIPE 848TS/TSCHS 16 2K-Z5033 1 UNION 848TS/TSCHS 17 2K-Z4618 1 NIPPLE 3/4 NPT X 2 1/4 848TS/TSCHS 18 2K-Z5034 1 3/4 NPT TEE 848TS/TSCHS 19 2J-Z4607 2 SAFETY VALVE 848TS/TSCHS 20 2V-6671 2 PILOT VALVE 848TS/TSCHS 21 2K-Y4403 4 CLOSE NIPPLE 3/8 NPT 848TS/TSCHS 22 2K-9688 2 TEE 3/8 NPT 848TS/TSCHS 23 2K-Z4612 2 NIPPLE WITH PRESSURE TAP 848TS/TSCHS 24 2T-Z7440 4 ELEC. THERMOSTAT manufactured after 8/2005 848TS/TSCHS PS-Z9318 4 THERMOSTAT SERVICE KIT manufactured before 8/2005 848TS/TSCHS 25 G5-824015 4 WIRE ASSEMBLY #1 848TS/TSCHS 26 G5-848017 1 WIRE ASSEMBLY 848TS “C” 848TS/TSCHS 27 G5-848016 1 WIRE ASSEMBLY 872TS “L” 848TS/TSCHS 28 2E-Z1858 1 SWITCH 848TS/TSCHS 29 2K-Y2967 1 CORD BUSHING 848TS/TSCHS 30 N2-30409 1 CORD SET 848TS/TSCHS
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
29
Page 30
PARTS LIST March 15, 2006, Rev. A
860TS-LP and 860TSCHS-LP Series
MODEL
Number
Key
Number
1 2K-Z4921 5 BURNER FLEX TUBE 860TS/TSCHS 2 2K-2675 5 FITTING 3/8 CC X 3/8 MPT 860TS/TSCHS 3 2P-1453 2 PIPE PLUG 860TS/TSCHS 4 2K-Y5550 5 NIPPLE 3/8 NPT X 1 1/2 860TS/TSCHS 5 2K-2665 3 ELBOW 3/8 NPT 860TS/TSCHS 6 2J-Z4610 5 SOLENOID VALVE 860TS/TSCHS 7 G5-Z4907 3 MOUNTING BRACKET 860TS/TSCHS 8 G5-824019 3 PILOT BRACKET ASSY 860TS/TSCHS 9 G5-824018 3 FLASH TUBE BRACKET ASSY 860TS/TSCHS 10 2J-Z4608 3 PILOT BURNER 860TS/TSCHS 11 2A-Y2017 3 PILOT ORIFICE 860TS/TSCHS 12 2K-Z4920 3 PILOT TUBE FLEX 860TS/TSCHS 13 2J-Z4609 3 THERMOCOUPLE 860TS/TSCHS 14 2K-Z4617 3 REDUCER BUSHING 860TS/TSCHS 15 2K-Z5032 1 INLET PIPE 860TS/TSCHS 16 2K-Z5033 2 UNION 860TS/TSCHS 17 2K-Z4618 4 NIPPLE 3/4 NPT X 2 1/4 860TS/TSCHS 18 2K-Z5034 2 3/4 NPT TEE 860TS/TSCHS 19 2J-Z4607 3 SAFETY VALVE 860TS/TSCHS 20 2V-6671 3 PILOT VALVE 860TS/TSCHS 21 2K-Y4403 6 CLOSE NIPPLE 3/8 NPT 860TS/TSCHS 22 2K-9688 2 TEE 3/8 NPT 860TS/TSCHS 23 2K-Z4612 2 NIPPLE WITH PRESSURE TAP 860TS/TSCHS 24 2T-Z7440 5 ELEC. THERMOSTAT manufactured after 8/2005 860TS/TSCHS PS-Z9318 5 THERMOSTAT SERVICE KIT manufactured before 8/2005 860TS/TSCHS 25 G5-824015 5 WIRE ASSEMBLY #1 860TS/TSCHS 26 G5-860017 1 WIRE ASSEMBLY 860TS “C” 860TS/TSCHS 27 G5-860016 1 WIRE ASSEMBLY 860TS “L” 860TS/TSCHS 28 2E-Z1858 1 SWITCH 860TS/TSCHS 29 2K-Y2967 1 CORD BUSHING 860TS/TSCHS 30 N2-30409 1 CORD SET 860TS/TSCHS 31 2K-Z4611 2 ELBOW 3/4 NPT 860TS/TSCHS 32 2K-Z5035 1 NIPPLE 3/4 NPT X 22 1/2 860TS/TSCHS
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
30
Page 31
PARTS LIST March 15, 2006, Rev A
872TS-LP and 872TSCHS-LP Series
MODEL
Number
Key
Number
1 2K-Z4921 6 BURNER FLEX TUBE 872TS/TSCHS 2 2K-2675 6 FITTING 3/8 CC X 3/8 MPT 872TS/TSCHS 3 2P-1453 3 PIPE PLUG 872TS/TSCHS 4 2K-Y5550 6 NIPPLE 3/8 NPT X 1 1/2 872TS/TSCHS 5 2K-2665 3 ELBOW 3/8 NPT 872TS/TSCHS 6 2J-Z4610 6 SOLENOID VALVE 872TS/TSCHS 7 G5-Z4907 4 MOUNTING BRACKET 872TS/TSCHS 8 G5-824019 3 PILOT BRACKET ASSY 872TS/TSCHS 9 G5-824018 3 FLASH TUBE BRACKET ASSY 872TS/TSCHS 10 2J-Z4608 3 PILOT BURNER 872TS/TSCHS 11 2A-Y2017 3 PILOT ORIFICE 872TS/TSCHS 12 2K-Z4920 3 PILOT TUBE FLEX 872TS/TSCHS 13 2J-Z4609 3 THERMOCOUPLE 872TS/TSCHS 14 2K-Z4617 3 REDUCER BUSHING 872TS/TSCHS 15 2K-Z5032 1 INLET PIPE 872TS/TSCHS 16 2K-Z5033 2 UNION 872TS/TSCHS 17 2K-Z4618 4 NIPPLE 3/4 NPT X 2 1/4 872TS/TSCHS 18 2K-Z5034 2 3/4 NPT TEE 872TS/TSCHS 19 2J-Z4607 3 SAFETY VALVE 872TS/TSCHS 20 2V-6671 3 PILOT VALVE 872TS/TSCHS 21 2K-Y4403 6 CLOSE NIPPLE 3/8 NPT 872TS/TSCHS 22 2K-9688 3 TEE 3/8 NPT 872TS/TSCHS 23 2K-Z4612 3 NIPPLE WITH PRESSURE TAP 872TS/TSCHS 24 2T-Z7440 6 ELEC. THERMOSTAT manufactured after 8/2005 872TS/TSCHS PS-Z9318 6 THERMOSTAT SERVICE KIT manufactured before 8/2005 872TS/TSCHS 25 G5-824015 6 WIRE ASSEMBLY #1 872TS/TSCHS 26 G5-872017 1 WIRE ASSEMBLY 872TS “C” 872TS/TSCHS 27 G5-872016 1 WIRE ASSEMBLY 872TS “L” 872TS/TSCHS 28 2E-Z1858 1 SWITCH 872TS/TSCHS 29 2K-Y2967 1 CORD BUSHING 872TS/TSCHS 30 N2-30409 1 CORD SET 872TS/TSCHS 31 2K-Z4611 2 ELBOW 3/4 NPT 872TS/TSCHS 32 2K-Z5035 1 NIPPLE 3/4 NPT X 22 1/2 872TS/TSCHS
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
31
Page 32
32
Page 33
8
33
la surface de chrome.
5. La négligence de l’entretien courant quotidien sur la surface de chome. pourraient endommager et affectent l’exécution de pierre, écran ou d’autres produits de nettoyage qui abrasive de nettoyage, brique de gauffreuse,
4. L’utilisation de tout produit chimique ou solution hors fonction. causer la surface à la peau, s’écailler, ou ébrécher font des impressions dans la surface qui pourrait
3. L’abus de tout instrument ou outil qui rayent ou la section de réglage de déviation.) surchauffer et décolorer la surface de chrome. (Voir des unités de gaz en permettant à l’appareil de
2. Sautez les réglages non réglés correctement sur
1. Incorrectement installé.
maltraitée ou soumise aux situations suivantes: autorisés que la surface de chrome a été abusée ou International Incorporated ou un de ses représentants est vide si elle est déterminée par Star Manufacturing initial de la date de l’installation. Cette garantie limitée 5 ans contre des défauts de fabrication au propriétaire gril de chrome sont justifi ées pendant une période de chrome dans son état initial. Toutes les surfaces de de l’entretien minimum de maintenir la surface de beaucoup d’années de faire cuire la fi abilité et exige Votre gril de chrome a été conçu pour vous donner
SURFACE DE GRIL DE CHROME EXCLUSIONS LIMITÉES DE GARANTIE DE
Page 34
ATTENTION
34
7
arrêtez le commutateur de puissance. Tournez les molettes à la plus basse confi guration et
EXTÉRIEURS DE CHROME CASSEZ L’CAction ET LES MODÈLES
de tour. Arrêtez les molettes à la position de repos aux brûleurs
D’CÉtranglement MANUELS DE COMMANDE DE VALVE ET
ARRÊT DURANT LA NUIT MODÈLES
CHAUDE. LE TIROIR DE REBUT CONTENANT LA GRAISSE PRENEZ LE SOIN EXTRÊME EN MANIPULANT
ATTENTION
moins une fois par jour. tiroir devrait être contrôlé et vidé si nécessaire ou au de l’avant pour nettoyer en tirant le tiroir en avant. Ce Un tiroir de rebut est situé à l’avant et peut être retiré
DE REBUT TIROIR
5. Maltraiter la surface vide la garantie.
de gril sur la surface de gril.
4. N’utilisez jamais le décapant liquide commercial
3. N’utilisez jamais les laines en acier.
instrument ou un bord pointu de spatule.
2. Ne frappez jamais la surface de gril avec un
ou les abrasifs sur la surface.
1. N’utilisez jamais la renovation, les pierres de gril,
surfaces de chrome).
3. Suivez les étapes 2 et 3 du soin de gril (non tissu humide propre. propre extérieur, suivi de l’essuyage avec le fève que l’ami peut être utilisé pour essuyer décapant non abrasif et non-chloré tel que la jour, un tissu et un a humides non-silicated,
2. Après l’érafl ure, pour la fi n du nettoyage de surface avec un tissu humide si désiré. pointu de type de rasoir large et essuyez la régulièrement avec des 4 “ (100mm) racleur
1. Enlevez l’excédent d’huile et la nourriture
de nettoyage devraient être suivies: empêcher cette condition, les suggestions suivantes il carbonisera et deviendra diffi cile de retirer. Pour l’effi cacité. Ne laissez pas la graisse s’accumuler car de gril industriel de chrome propre et exécuter en haut petit et l’effort de maintenir ce scintillement extérieur sur la plaque signalétique.) Elle prend le temps très “CHS“ à la fi n de la désignation de numéro de type (Des grils extérieurs de chrome sont identifi és par
SOIN de GRIL (SURFACES de CHROME)
avant, vers le haut de et dehors. cuisine ordinaire. Le tiroir est retiré en tirant en et lavent de la même manière qu’une batterie de
3. Du moins une fois par jour, retirent le tiroir de rebut avec un tissu mou. du gril. Essuyez l’avant de pupitre de commande abrasif pour nettoyer le corps d’acier inoxydable
2. Employez un tissu propre et un bon décapant non­en acier entrant dans la nourriture. les laines en acier en raison du danger des rubans de gril tandis que le gril est chaud. N’utilisez pas et reseasoned. Utilisez la pierre de renovation ou nourriture, le gril devrait être complètement récuré une accumulation brûler-sur de graisse et de de rebut est donné pour les raclures. S’ il y a la graisse et la nourriture excessives. Un tiroir un racleur ou une spatule fl exible pour enlever
1. Après que chaque utilisation, érafl ent le gril avec
pour la propreté devraient être suivies: empêcher cette condition, les suggestions suivantes dure il est extrêmement diffi cile retirer que. Pour gommeux et carboniser alors dans une substance est autorisée pour s’accumuler, elle pour un gâteau attrayant et exécutant en haut l’effi cacité. Si la graisse Il prend le temps et l’effort très petits de maintenir le gril
SOIN de GRIL (SURFACES de NON-CHROME)
Page 35
6
35
température choisie. (minimum), le gril mettra à jour automatiquement la Après une période de préchauffage de 30 minutes Placez la molette de cadran à la confi guration désirée.
CUISINE
que le plat de gril "soit cassé dedans." bâton au gril la cuisine de la surface jusqu’à ce d’assaisonnement peut, dans une certaine mesure, Même avec la nourriture soigneuse
être opérationnelle. et essuyez. La surface de gril devrait maintenant autre demi-heure, et encore retirez gros excessif dessus de la zone chaude de cuisine pour une
4. Appliquez un autre fi lm d’huile de cuisine au-
3. Retirez gros excessif et le chiffon propres. surface de gril. Ce fi lm devrait rester la demi-heure chaude de graisse au-dessus du gril faisant cuire la surface. répandu une couche mince d’huile de cuisine ou de
2. En utilisant un tissu propre, pas une spatule, a à 350°F (174.0°C).
1. Tournez le cadran de commande de la température
façon suivante: assaisonnez la surface de chauffage de gril de la Avant utilisation et après chaque récurage complet, assaisonné pour empêcher la nourriture de coller. le gril ait été complètement nettoyé, il devrait être Nettoyez la surface de gril complètement. Après que
CHROME) CHAUFFAGE de GRIL (SURFACES de NON­EN ASSAISONNANT LA SURFACE de INSTRUCTIONS DE FONCTIONNEMENT
de cette prise. Ne coupez pas ou ne retirez pas la fourche fondante un réceptacle correctement fondé de trois-fourche. électrique, l’unité doit être branchée directement à volt 15 seulement. Pour la protection contre le choc monophasé à C.A. de cycle de l’ampère 50/60 de L’unité est conçue pour l’usage sur 120 un circuit sont équipés d’une trois-fourche fondant la prise. Des grils extérieurs instantanés d’action et de chrome
DE CHROME SEULEMENT INSTANTANÉE ET LES MODÈLES EXTÉRIEURS CONNEXION ÉLECTRIQUE POUR L’CAction
augmenter la fl amme. le sens contraire des aiguilles d’une montre pour pour diminuer la taille de fl amme; tournez dans
4. Tournez dans le sens des aiguilles d’une montre du logement de commande.
3. Une vis d’approche est plac de l’avant ou du côté
être approximativement 1/8" de haut. sur tous les ports de brûleur. Cette fl amme devrait Une petite fl amme régulière devrait être visible
2. Tournez le cadran à la confi guration de 200 degrés. de puissance en arrière. de maximum la fl amme de brûleur à la commande
1. Placez la commande à la confi guration et à l’attente
satisfaite. la confi guration de la chaleur de commande a été fl amme uniforme régulière à travers le brûleur quand confi guration minimum de fl amme qui fournit une Les modèles de commande d’étranglement ont une
D’CÉtranglement MODÈLE SEULEMENT LE RÉGLAGE DE DÉVIATION SUR LA COMMANDE
travers le brûleur entier. brûleur. La fl amme doit être régulière et même à est instable ou se soulevante de la surface de
3. N’ouvrez pas l’obturateur à un point où la fl amme et la fl amme est un bleu dur. jusqu’à ce que les extrémités jaunes disparaissent des extrémités jaunes, puis augmentez l’ouverture jusqu’à ce que la fl amme soit un bleu mou avec
2. Diminuez lentement l’ouverture d’obturateur d’air plus élevée et observez la fl amme de brûleur.
1. Tournez le bouton de commande à la position la
température de commande ait été satisfaite. est à la pleine entrée avant que la confi guration de la complet. Tout réglage doit être fait quand le brûleur l’obturateur d’air en place après que le réglage soit faire tout réglage et pour serrer la vis pour verrouiller côté inférieur du venturi. Desserrez cette vis pour L’obturateur d’air de brûleur a une vis de blocage du
BRÛLEUR RÉGLAGE D’CObturateur D’CAir DE
pilote. thermocouple est entouré par la fl amme approximativement 3/8" de l’extrémité de D’CAction Ajustez le pilote tellement
DE THERMOSTAT ET DE CHROME MODÈLES EXTÉRIEURS INSTANTANÉS
tourné à la haute. brûleur quand le bouton de commande est en fournissant toujours l’allumage immédiat de Ajustez la fl amme aussi basse que possible tout
DE VALVE ET D’CÉtranglement MODÈLES MANUELS DE COMMANDE
être allumés juste après que le gaz est allumé. Les grils sont équipés des pilotes debout et devraient
RÉGLAGE PILOTE DE FLAMME
Page 36
36
5
de puissance.
6. Pour arrêter des brûleurs, arrêtez le commutateur
et placez les thermostats à la position désirée.
5. Mettez en marche le commutateur de puissance s’est allumé. Répétition pour tous les pilotes. pendant 60 secondes ou jusqu’ aux séjours pilotes sûreté. Allumez le pilote. Tenez le bouton de remise
4. Enfoncez et tenez le bouton pilote de remise de
3. Ouvrez la valve principale. les thermostats à la plus basse confi guration.
2. Arrêtez le commutateur de puissance et tournez minutes au gaz clair.
1. Arrêtez la valve principale à l’unité et attendez 5
THERMOSTAT ET DE CHROME D’CAction MODÈLES EXTÉRIEURS INSTANTANÉS DE
hors fonction.
5. Pour arrêter des brûleurs, tournez les molettes à désirée.
4. Tournez les molettes de brûleur à la position les pilotes.
3. Ouvrez la valve principale à l’unité et allumez tous commande.
2. Arrêtez toutes les molettes et soupapes de minutes au gaz clair.
1. Arrêtez la valve principale à l’unité et attendez 5
D’CÉtranglement MODÈLE LA COMMANDE MANUELLE DE VALVE ET
6. Réinstallez le panneau avant. de brûleur. capots d’orifi ce et réinstallez les vis de support
5. Glissez les brûleurs en arrière au-dessus des installez les capots d’orifi ce de naturel.
4. Retirez les capots d’orifi ce de gaz propane et d’orifi ce.
3. Glissez les brûleurs dégagent les capots l’accès de chambre de combustion couvre.
2. Retirez les vis de support de brûleur au centre de sur l’avant et le bas.
1. Retirez le panneau avant en retirant les vis plac
comme suit: les capots de l’orifi ce situés derrière le panneau avant propane. Pour convertir en gaz de naturel installez et est expédiée de l’usine pour l’usage avec le gaz Cette gauffreuse est équipée des capots fi xes d’orifi ce
GAZ NATUREL- CONVERSION
d’alimentation de gaz. jusqu’à ce que le rapport réel soit établi à la canalisation empêcher l’entrée de la saleté. Ne retirez pas ce joint La prise de gaz du gril est scellée à l’usine pour
RACCORD DE LA CANALISATION DE GAZ
amont de la tubulure et à moins de six pieds du gril. Une valve coupée manuelle devrait être installée en
VANNE D’ARRÊT MANUELLE
après que le gaz est allumé. des pilotes debout et devraient être allumées juste soient consommation. Les gauffreuses sont équipées jusqu’à ce que les huiles et les impuretés de préservatif Quand la gauffreuse est d’abord allumée, il fumera
ALLUMER DES INSTRUCTIONS
chandelle ou d’autres sources d’allumage. Ne pas utiliser d’allumettes, la fl amme d’une
ATTENTION
d’eau ou une autre matière acceptable pour ce but. l’étanchéité, il faut utiliser une solution de savon et Vérifi er l’étanchéité de toute la tuyauterie. Pour vérifi er
LA VÉRIFICATION LE GAZ FUIT
attacher un indicateur de pression. 1/8" prise de pipe est situé sur la tubulure pour visibles sur la prise. Réinstallez le chapeau. Un réinstallez. Les lettres “NAT“ seront maintenant du centre du régulateur. Inversez la prise et la
10.2cm) en retirant le chapeau rainé ou d’hexa de l’eau (de 12.7cm) ou 4" colonne de l'eau (de
7. Placez le régulateur de pression à 5" colonne
10“ pression de tubulure de colonne de l’eau. est expédiées pour l’usage avec le gaz propane avec au régulateur ne doit pas excéder 1/2 psig. Cette unité alors reliée à elle. La pression d’approvisionnement d’admission à l’arrière de l’unité. L’offre de gaz est chaque gauffreuse. Il devrait être relié dans le tuyau Un régulateur de pression convertible est équipé de
RÉGULATEUR DE PRESSION DU GAZ
toute impureté interne libre. tous les tuyaux et raccords doivent être exempts de fonctionnement. Lors de l’installation de cet appareil, cet appareil endommagera la vanne et en affectera le métallique qui entre dans les canalisations de gaz de AVERTISSEMENT : Toute impureté libre ou particule composés doivent résister à l’action des gaz propanes. sur les fi letages mâles des raccords à tuyaux. Ces composé combiné que modérément et seulement si elle a la capacité nécessaire. Il ne faut utiliser le existante, il faut vérifi er cette dernière pour déterminer l’appareil. S’il faut raccorder l’appareil à la tuyauterie exigences d’admission de pleine puissance dans alimentation suffi sante de gaz pour répondre aux est installée doivent être telles qu’elle fournisse une La taille de la tuyauterie à gaz et la façon dont elle
TUYAUTERIE À GAZ
Page 37
37
4
l’utilisation. être rebranché comme initialement installé avant débranché pour le service ou le nettoyage qu’il doit compte qu’il y ait une contrainte sur l’appareil et si relient le couplage, tout le personnel doit se rendre est équipé des roulettes et est gaz lié à un rapide protéger la connexion de ligne de gaz. Si un appareil d’utiliser des moyens approuvés de passe-fi ls pour ajoutent environ 6-1/4 “ de taille à l’unité. Soyez sûr longueur de tube, longueur hors-tout. Les roulettes la roulette. La jambe de coupe devrait mesurer 19 “ découpage le mur intérieur de tube avant d’installer jambe en utilisant une scie et un de-burr droits de soigneusement et découpé le de bas de chaque de matériel facultatif. Pour d’installation la marque avec les modèles de stand de plancher ou le stand Lots de roulettes: Des roulettes peuvent être utilisées
DE STAND. OU DES JAMBES ET L'ETAGERE FOURNIES N’INSTALLEZ PAS SANS ATTACHER ES PIEDS
ATTENTION
avec d’autres unités. ont un réglage de 1-3/4 “ pour la ligne précise et parfaite
être niveau. Unité de niveau en ajustant (4) les pieds qui plancher qui doivent être vissés dans le corps. L’unité doit Ce gril est fourni avec 4 pieds ou jambes de stand de
ÉQUILIBRAGE DE L’APPAREIL
Page 38
38
3
l’appareil. Ne bas boucher cette section. L’air nécessaire à la combustion entre par le bas de
PRISES D’AIR EN BAS
ATTENTION
CODES LOCAUX, LE CAS ÉCHÉANT. AU PROPANE CAN/CGA-B149.2 ET AUX CGA-B149.1 OU AU CODE D’INSTALLATION D’INSTALLATION AU GAZ NATUREL CAN/ ÊTRE CONFORME AU CODE COURANT AU CANADA, L’INSTALLATION DOIT
être fournis. Les vivres pour provision de l'air adéquate doivent
LA PROVISION DE L'AIR
codes locaux. L’installation d’échappement doit se conformer aux fi ltres ou n’importe quel autre matériel combustible. 48 “ sera fournie entre le dessus de l’appareil et les de fl amme. Une distance verticale pas moins de de effi cace d’échappement avec des fi ltres de preuve la fumée et devraient être installés sous un capot Les grils créent en soi beaucoup de la chaleur et de
ÉPUISEZ LE BALDAQUIN
pressions égales à ou de moins que ½ PSIG. de pression de la tuyauterie d’alimentation de gaz à des
sa vanne d’arrêt manuelle individuelle lors des essais être isolés de la tuyauterie d’alimentation du gaz en fermant PSIG. Cet appareil et son régulateur de pression doivent tuyauterie en question à des pressions en dessus de ½ d’alimentation du gaz lors des essais de pression de la d’arrêt individuelles doivent être débranchés de la tuyauterie Cet appareil, son régulateur de pression et ses vannes
gaz pour l’approbation de l’installation fi nale. locales. En tout cas, il faut appeler votre société du installations de gaz et vos exigences de gaz d’installation qualifi ée. Ils doivent connaître les de faire installer cet appareil par une agence Pour votre propre protection, on vous recommande
contrainte au connecteur. retenants de garder contre la transmission de la Il doit également être installé avec des moyens conforme à la norme ANSI Z21.41 ou au CAN1-6.9. ou au CAN/CGA-6.16 et à un dispositif rapide étant connecteur étant conforme à la norme ANSI Z21.69 il doit être installé avec les roulettes fournies, un Quand cet appareil est installé avec des roulettes,
-IMPORTANT-
COMPAGNIE DE GAZ LOCALE. RÈGLES ET RÉGLEMENTATIONS DE LA DES ÉTATS-UNIS ET À TOUTES LES "ANSI Z223.1 - TOUTE DERNIÈRE ÉDITION" CODE NATIONAL DE GAZ COMBUSTIBLE L’installation de l’appareil doit se conformer au
pour l’exécution appropriée et l’entretien. dégagement adéquat devrait également être donné et au moins 6 “ (16cm) des côtés et du dos. Le moins 48 “ (120cm) à partir du dessus de l’appareil matériel combustible et non-combustible doit être au sur les countertops non-combustibles seulement. Le
ET CLAIRE DES COMBUSTIBLES! Pour l’usage MAINTENEZ LA RÉGION D’CAppareils LIBRE
extérieures de l’unité. de gauffreuse et nettoyez complètement les surfaces l’éclairage. Éliminez le plastique protecteur du plat protection et d’emballage à partir de l’unité avant Soyez sûr d’enlever tout le matériel de papier de
Intoxiquer - La Conversion. facilement être converties en naturel. Voir Le Naturel unité est expédiées pour le gaz propane et peuvent l’usage sur le gaz naturel ou de propane. Cette Des grils de série d’Ultra-Max sont équipés pour
emplacements de service de traiteur. l’usage directement par le grand public dans des consommateur dans et autour de la maison ni pour en son exécution et n’est pas vendu pour l’usage du seulement par le personnel qualifi é et expérimenté Ce matériel est conçu et vendu pour l’usage commercial
ATTENTION
NOTIFICATION
DONNÉES GÉNÉRALES D’INSTALLATION
Page 39
39
2
plus rapide. questions qui peuvent se poser. Veuillez avoir votre numéro et numéro de série de type pour un service Star (1-800-807-9054) disponible pendant des heures de travail normales pour répondre à toutes les Référez-vous à la liste autorisée de centre commercial équipée d'unité. Le service SVP de service de Entrez en contact avec votre agent autorisé local de service pour le service ou l'entretien requis.
ENTRETIEN ET RÉPARATIONS
correspondants pour l’équipement précédemment acheté. aux améliorations, aux additions ou aux remplacements telles révisions ne ont pas droit l’acheteur aux changements, conception de produits sans communication préalable. De Star se réserve le droit de changer des caractéristiques et la
NOTIFICATION
responsabilité. par usine véritable de Star soulage le fabricant de toute la Employer n’importe quelle partie autre que les pièces fournies
NOTIFICATION
MAINTENEZ CE MANUEL POUR LA FUTURE RÉFÉRENCE
accompagnant l’appareil. instructions importantes de fonctionnement et d’entretien du manuel Ce symbole est prévu pour alerter l’utilisateur à la présence des
SYMBOLE DE SÛRETÉ
Page 40
40
fournisseur local de gaz. sent le gaz. Obtenez les instructions du détaillées d’être suivi en cas que l’opérateur emplacement en avant, des instructions En outre, là devrait être signalé, dans un
d’installer et utiliser cet appareil. aéré. Référez-vous aux instructions avant et utilisé seulement dans l’espace bien­installé selon des règlements actuels AVERTISSEMENT: Cet appareil sera
appareil. proximité de ceci ou d’aucun autre vapeurs ou liquides inflammables à ou n’utilisez pas l’essence ou d’autres POUR VOTRE SÛRETÉ: N’enregistrez pas
d’installer ou entretenir ce matériel. et d’entretien complètement avant les instructions d’installation, d’opération matériels, des dommages ou la mort. Lisez l’entretien peuvent causer des dégats le réglage, le changement, le service ou AVERTISSEMENT: L’installation inexacte,
2M-Z7924 Rev. A 3/15/2006
et d’opération
d’installation
Instructions
MODELES
Fax: (314) 781-2714 Phone: (314) 781-2777
St. Louis, MO 63143 10 Sunnen Drive
International Inc. Manufacturing Star
872M-LP 872T-LP 872TS-LP 872TSCHS-LP 860M-LP 860T-LP 860TS-LP 860TSCHS-LP 848M-LP 848T-LP 848TS-LP 848TSCHS-LP 836M-LP 836T-LP 836TS-LP 836TSCHS-LP 824M-LP 824T-LP 824TS-LP 824TSCHS-LP
GRILS A GAZ ULTRA-MAX
Loading...