Star Manufacturing 824TCHS Installation Manual

Star Manufacturing International Inc.
Operating Instructions
10 Sunnen Drive St. Louis, MO 63143
Phone: (314) 678-6303 Fax: (314) 781-2714
Instructions d’installation
et d’opération
2M-Z4877 Rev. H 2/28/2012
ULTRA-MAX™ GAS GRIDDLE MODELS
GRILS A GAZ ULTRA-MAX MODELES
824M 824T 824TS 824TCHS 824TSCHS
836M 836T 836TS 836TCHS 836TSCHS 848M 848T 848TS 848TCHS 848TSCHS 860M 860T 860TS 860TCHS 860TSCHS 872M 872T 872TS 872TCHS 872TSCHS
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
AVERTISSEMENT: L’installation inexacte, le réglage,
le changement, le service ou l’entretien peuvent causer des dégats matériels, des dommages ou la mort. Lisez les instructions d’installation, d’opération et d’entretien complètement avant d’installer ou entretenir ce matériel.
FOR YOUR SAFETY: Do not store or
use gasoline or other ammable vapors or
liquids in the vicinity of this or any other appliance.
POUR VOTRE SÛRETÉ: N’enregistrez pas ou
n’utilisez pas l’essence ou d’autres vapeurs ou
liquides inammables à proximité de ceci ou d’aucun
autre appareil.
WARNING: This appliance shall be installed in accordance with current regulations and used only in well­ventilated space. Refer to instructions before installing and using this appliance.
AVERTISSEMENT: Cet appareil sera installé selon
des règlements actuels et utilisé seulement dans l’espace bien-aéré. Référez-vous aux instructions avant d’installer et utiliser cet appareil.
In addition, there should be posted, in a prominent location, detailed instructions to be followed in the event the operator smells gas. Obtain the instructions from the local gas supplier.
En outre, là devrait être signalé, dans un
emplacement en avant, des instructions détaillées
d’être suivi en cas que l’opérateur sent le gaz.
Obtenez les instructions du fournisseur local de gaz.
11
2
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
Star reserves the right to change specications and product design without
notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specications contained in this sheet are subject to change without notice. While Star International Holdings Inc., Company exercises good faith efforts to provide information that is accurate, we are not
responsible for errors or omissions in information provided or conclusions
reached as a result of using the specications. By using the information provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when
you call to ensure a faster service.
SAFETY SYMBOL
Model No.
Serial No.
Voltage
Purchase Date
Business 8:00 am to 4:30 p.m. Central Standard Time Hours:
Telephone: (314) 678-6303 Fax: (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com
Warranty@star-mfg.com
Website: www.star-mfg.com
Service Help Desk
Authorized Service Agent Listing
Reference the listing provided with the unit
or for an updated listing go to:
Website: www.star-mfg.com E-mail Service@star-mfg.com
Mailing Address: Star International Holdings Inc., Company
10 Sunnen Drive St. Louis, MO 63143 U.S.A
22
SPECIFICATIONS
IL2241
A
B
30 5/8”
(77.8CM)
18”
(45.8CM)
13 9/16”
(34.4CM)
7 7/16”
(13.8CM)
4”
(10.1CM)
32 3/8”
(82.3CM)
GAS INLET
Model Type Controls BTUH Griddle Area
824M Manual Valve
824T/TM Throttling Control 824TS Snap Action Control
824TSCHS Snap Action Control w/Crome Plate 836M Manual Valve
836T Throttling Control 836TS Snap Action Control
836TSCHS Snap Action Control w/Crome Plate 848M Manual Valve
848T Throttling Control 848TS Snap Action Control
848TSCHS Snap Action Control w/Crome Plate 860M Manual Valve
860T Throttling Control 860TS Snap Action Control
860TSCHS Snap Action Control w/Crome Plate 872M Manual Valve
872T
Throttling Control
872TS Snap Action Control 872TSCHS Snap Action Control w/Crome Plate
2 60,000
3 90,000
4 120,000
5 150,000
6 180,000
573 sq in
(3697sq. cm)
860 sq. in.
(5545 sq. cm)
1146 sq. in
(7397 sq. cm)
1433 sq in
(9242 sq cm)
1719 sq in
(11091 sq cm)
Dimensions Approx Weight
Width Depth Height Installed Shipping
214lbs
24"
(61cm)
(97kg) 220lbs
(99.7kg)
(110.6kg)
(111.5kg)
222lbs
(100.6kg)
(113.3kg)
321lbs
36"
(91.4cm)
(145.4kg)
330lbs
(149.5kg)
(165.8kg)
(167.2kg)
333lbs
(150.9kg)
(169.9kg)
428lbs
48"
(122cm)
32 3/8"
(82.2cm)
18"
(45.7cm)
(193.3kg)
440lbs
(199.4kg)
(221.1kg)
(222.9kg)
444lbs
(201.2kg)
(226.6kg)
535lbs
60"
(152.4cm)
(242.4kg)
550lbs
(249.2kg)
(276.4kg)
(278.7kg)
555lbs
(251.5kg)
(283.2kg)
642lbs
72"
(182.9cm)
(290.9kg)
660lbs
(299kg)
666lbs
(301.8kg)
(331.7kg)
(334.4kg)
(339.8kg)
244lbs
246lbs
250lbs
366lbs
369lbs
375lbs
488lbs
492lbs
500lbs
610lbs
615lbs
625lbs
732lbs
738lbs
750lbs
33
CAUTION
GENERAL INSTALLATION DATA
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations.
Before using your new equipment, read and understand all the instructions & labels associated with the unit prior to putting it into operation. Make sure all people associated with its use understand the units operation & safety before they use the unit.
Ultra-Max series griddles are equipped for use on either natural or propane gas. All units are shipped for natural gas and can easily be converted to propane. See Propane Gas - Conversion.
-IMPORTANT-
Be sure to remove all paper protection and packing material from unit prior to lighting. Remove the protective plastic from the griddle plate and thoroughly clean the unit's exterior surfaces.
KEEP THE APPLIANCE AREA FREE AND CLEAR FROM COMBUSTIBLES! For use on non-combustible countertops only. Combustible and non-combustible material must be at least 48" (120cm) from the top of the appliance and at least 6" (16cm) from the sides and back. Adequate clearance should also be provided for proper operation and servicing.
The installation of the Appliance must conform to the NATIONAL FUEL GAS CODE "ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2 PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.
NOTICE
When this appliance is installed with casters, it must be installed with the casters supplied, a connector complying with either ANSI Z21.69 or CAN/CGA-6.16 and a quick-disconnect device complying with either ANSI Z21.41 or CAN1-6.9. It must also be installed with restraining means to guard against transmission of strain to the connector.
For your protection, we recommend a qualied installing agency install this appliance.
They should be familiar with gas installations and your local gas requirements. In any
case, your gas company should be called to approve the nal installation.
This appliance, its pressure regulator and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG. This appliance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG.
EXHAUST CANOPY
Griddles inherently create a good deal of heat and smoke and should be installed under an efcient exhaust hood with ame proof lters. A vertical distance of not less than 48" shall be provided between the top of the appliance and lters or any other combustible material. Exhaust installation must
conform to local codes.
CAUTION
AIR SUPPLY: Provisions for adequate air supply must be provided.
AIR INTAKES IN BOTTOM
Air for combustion enters from the bottom of the unit. Do not obstruct this area.
44
CAUTION
LEVELING UNIT
This griddle is supplied with 4 feet or oor stand legs which must be screwed into the body. After the griddle is in its nal position, adjust the legs to create 1/8 inch slant from back to front. This will
allow the grease to run into the grease gutter and provide the proper combustion air for the burners.
Adjusting the (4) feet which have an adjustment of 1-3/4" for accurate and perfect line-up with other
units.
DO NOT INSTALL WITHOUT ATTACHING FEET OR SUPPLIED STAND LEGS AND SHELF - DO NOT REMOVE FEET.
Caster Kits: Casters can be used with oor
stand models or optional equipment stand. For installation, carefully mark and cut off from the bottom of each leg using a straight cutting saw and de-burr the inside tube wall prior to installing the caster. Cut leg should measure
19" tube length, not overall length. Casters add about 6-1/4" of height to the unit. Be
sure to use approved strain relief means for protecting gas line connection. If an appliance is equipped with casters and is gas connected with a quick connect coupling, all personnel must be aware that there is a restraint on the appliance and if disconnected for service or cleaning it must be reconnected as originally installed prior to use.
55
GAS PIPING
PLUG
IL1199
Natural
Regulator
Propane / LP
Gas piping shall be of such size and so installed as to provide a supply of gas sufcient to meet the
full gas input of the appliance. If the appliance is to be connected to existing piping, it shall be checked to determine if it has adequate capacity. Joint compound shall be used sparingly and only on the male
threads of the pipe joints. Such compounds shall be resistant to the action of L.P. gases. WARNING:
Any loose dirt or metal particles which are allowed to enter the gas lines on this appliance will damage
the valve and affect its operation. When installing this appliance, all pipe and ttings must be free from
all internal loose dirt.
GAS PRESSURE REGULATOR
A convertible pressure regulator is provided with each griddle. It should be connected to the inlet pipe at the rear of the unit. The gas supply is then connected to it. The supply pressure to the regulator is not to exceed 1/2 psig. All units are shipped for use with natural gas. M and T Series Models are
shipped set for 5" water column manifold pressure. TS and TSCHS Series Models are shipped set for 4" water column manifold pressure.
MANUAL SHUT OFF VALVE
A manual shut off valve should be installed upstream from the manifold and within six feet of the griddle.
CONNECTING GAS SUPPLY LINE
The gas inlet of the griddle is sealed at the factory to prevent entry of dirt. Do not remove this seal until the actual connection is made to the gas supply line.
PROPANE GAS - CONVERSION
This griddle is equipped with xed orice hoods and is shipped from the factory for use with natural gas. To convert to propane gas install the orice hoods located behind the front panel as follows:
1. Remove the front panel by removing the screws located on the front and bottom.
2. Remove the burner mounting screws in the center of the combustion chamber access covers.
3. Slide the burners back off the orifice hoods.
4. Remove the natural gas orice hoods and install the propane orice hoods.
5. Slide the burners back over the orice hoods
and reinstall the burner mounting screws.
6. Reinstall the front panel.
7. Set the pressure regulator to 10" (25.4cm)
water column by removing the slotted or hex cap from the center of the regulator. Invert
the plug and reinstall. The letters "LP" will now be visible on the plug. Reinstall the cap. An 1/8"
pipe plug is located on the manifold for attaching a pressure gauge.
CAUTION
CHECKING FOR GAS LEAKS
Check entire piping system for leaks. Soap and water solution or other material acceptable for the purpose, shall be used in locating gas leakage.
Matches, candle ame or other sources of ignition shall not be used for
locating gas leaks.
66
Pilot
Saftey Valve
IL1200
CAUTION
PILOT FLAME ADJUSTMENT
The griddles are equipped with standing pilots and should be lit immediately after the gas is turned on.
MANUAL VALVE AND THROTTLING CONTROL MODELS
Adjust the ame as low as possible while still providing immediate burner ignition when
the control knob is turned to high.
SNAP ACTION THERMOSTAT AND CHROME SURFACE MODELS
Adjust the pilot so approximately 3/8" of the thermocouple tip is surrounded by
the pilot ame.
LIGHTING INSTRUCTIONS
When the griddle is rst lit, it will smoke until the preservative oils and impurities are burned off. The
griddles are equipped with standing pilots and should be lit immediately after the gas is turned on. The Unit should be properly leveled prior to lighting.
DO NOT ATTEMPT TO LIGHT YOUR PILOT BURNER IF YOU EXPERIENCE A STRONG GAS ODOR.
MANUAL VALVE AND THROTTLING CONTROL MODELS
1. Turn off the main valve to the unit and wait 5 minutes to clear gas.
2. Turn off all knobs and pilot valves.
3. Turn on main valve to unit and light all pilots.
4. Turn burner knobs to desired position.
5. To turn burners off, turn knobs to off.
SNAP ACTION THERMOSTAT AND CHROME SURFACE MODELS
1. Turn all knobs and power switch to "OFF" and wait 5 minutes to clear gas. Remove any grease trays.
2. Put lighter under the front of the griddle. FIG 1
3. Look through large hole in front panel.
4. Move lighter up to the pilot.
5. Put your other hand under the front of the griddle and press the button on the safety valve.
6. Once the pilot is lit, remove the lighter and continue to press the button for at least 30 seconds.
7. Once pilot remains lit, continue to all other pilot lights that need liting.
8. To turn burners off, turn off power switch.
FIG 1, Place Lighter under griddle
77
CAUTION
BURNER AIR SHUTTER ADJUSTMENT
The burner air shutter has a locking screw on the bottom side of the venturi. Loosen this screw
to make any adjustment and tighten the screw to lock the air shutter in place after adjustment is complete. Any adjustment must be made when the burner is at full input before the control temperature setting has been satised.
1. Turn the control knob to the highest position and observe the burner ame.
2. Slowly decrease the air shutter opening until the ame is a soft blue with yellow tips, then increase the opening until the yellow tips disappear and the ame is a hard blue.
3. Do not open the shutter to a point where the ame is unstable or lifting from the burner surface. The ame must be steady and even across the entire burner.
The following was set at the factory and the adjustment should only be made by an authorized installer and only if you are experiencing this specic problem.
BYPASS ADJUSTMENT ON THROTTLING CONTROL MODELS ONLY
Throttling control models have a minimum ame setting that provides a steady uniform ame across the burner when the control heat setting has been satised.
1. Set the control at the maximum setting and wait for the burner ame to throttle back.
2. Turn the dial to the 200 degree setting. A small steady ame should be visible on all the burner ports. This ame should be approximately 1/8" high.
3. An adjustment screw is located either on the front or side of the control housing.
4. Turn clockwise to decrease the ame height; turn counterclockwise to increase the ame
CAUTION
CAUTION
ELECTRICAL CONNECTION FOR SNAP ACTION AND CHROME SURFACE MODELS ONLY
Snap action and chrome surface griddles are equipped with a three-prong grounding plug. The unit is designed for use on a 120 volt 15 amp 50/60 cycle AC single-phase circuit only. For protection against electrical shock, the unit must be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
Do not connect to any other type of current or serious damage will occur.
OPERATING INSTRUCTIONS
SEASONING THE GRIDDLE HEATING SURFACE (NON-CHROME SURFACES)
Clean the griddle surface thoroughly. After the griddle has been thoroughly cleaned, it should be seasoned to prevent food from sticking. Before using and after each thorough scouring, season the griddle heating surface in the following manner:
1. Turn the temperature control dial to 350°F (174.0°C).
2. Using a clean cloth, not a spatula, spread a thin lm of cooking oil or shortening over the griddle cooking surface. This lm should remain on the hot griddle surface 1/2 hour.
3. Remove excess shortening and wipe clean.
4. Apply another lm of cooking oil over the hot cooking area for another 1/2 hour, and again remove
excess shortening and wipe clean. The griddle surface should now be ready for use.
Even with careful seasoning food may, to some extent, stick to the griddle cooking surface until griddle plate is "broken in."
COOKING
Set the dial knob to the setting desired. After a 30 minute (minimum) preheating period, the griddle will automatically maintain the selected temperature.
88
GRIDDLE CARE (NON-CHROME SURFACES)
It takes very little time and effort to keep the griddle attractive and performing at top efciency. If
grease is permitted to accumulate, it will form a gummy cake and then carbonize into a hard substance
which is extremely difcult to remove. To prevent this condition, the following suggestions for
cleanliness should be followed:
1. After each use, scrape the griddle with a scraper or exible spatula to remove excess grease and
food. A waste drawer is provided for the scrapings. If there is an accumulation of burned-on grease and food, the griddle should be thoroughly scoured and reseasoned. Use pumice or griddle stone while the griddle is warm. Do not use steel wool because of the danger of steel slivers getting into the food.
2. Use a clean cloth and good non-abrasive cleaner to clean the stainless steel body of the griddle. Wipe the control panel front with a soft cloth.
3. At least once a day, remove the waste drawer and wash in the same way as an ordinary cooking utensil. The drawer is removed by pulling forward and out.
GRIDDLE CARE (CHROME SURFACES)
(Chrome surface griddles are marked with "CHS" at the end of the model number designation on the
nameplate.) It takes very little time and effort to keep this Industrial Chrome griddle surface sparkling
clean and performing at top efciency. DO NOT allow grease to accumulate as it will carbonize and become difcult to remove. To prevent this condition, the following cleaning suggestions should be
followed:
1. Remove excess oil and food regularly with a 4" (100mm) wide razor sharp type scraper and wipe
surface with a damp cloth if desired.
2. Following the scraping, for end of the day cleaning, a damp cloth and a non-silicated, non-abrasive, non-chlorinated cleaner such as Bon-Ami may be used to wipe surface clean, followed by wiping with clean wet cloth.
3. Follow steps 2 and 3 from Griddle Care (Non-Chrome Surfaces).
CAUTION
CAUTION
CAUTION
1. Never use pumice, griddle stones, or abrasives on the surface.
2. Never strike the griddle surface with a sharp instrument or spatula edge.
3. Never use steel wool.
4. Never use commercial liquid grill cleaner on the griddle surface.
5. Abusing the surface voids the warranty.
WASTE DRAWER
A waste drawer is located at the front and can be removed from the front for cleaning by pulling drawer forward. This drawer should be checked and emptied when necessary or at least once per day.
EXERCISE EXTREME CARE IN HANDLING THE WASTE DRAWER CONTAINING HOT GREASE.
OVERNIGHT SHUTDOWN
MANUAL VALVE AND THROTTLING CONTROL MODELS
Turn knobs to the off position to turn burners off.
SNAP ACTION AND CHROME SURFACE MODELS
Turn knobs to the lowest setting and turn power switch off.
99
CHROME GRIDDLE SURFACE LIMITED WARRANTY EXCLUSIONS
Your chrome griddle has been designed to give you many years of cooking reliability and requires minimum maintenance to keep the chrome surface in its original condition. All chrome griddle surfaces are warranted for a period of 5 years against manufacturing defects to the original owner from the date of installation. This limited warranty is void if it is determined by Star Manufacturing International Incorporated or one of its authorized representatives that the chrome surface has been misused or
abused or subjected to the following situations:
1. Improperly installed.
2. By-pass adjustments not set properly on gas units allowing the appliance to overheat and discolor the chrome surface. (See by-pass adjustment section.)
3. The misuse of any instrument or tool which scratches or makes indentations in the surface which could
cause the surface to peel, ake, or chip off.
4. The use of any chemical or abrasive cleaning solution, griddle brick, stone, screen or other cleaning products which could damage and affect the performance of the chome surface.
5. The neglect of daily routine maintenance to the chrome surface.
1010
Ces symboles sont utilisés pour souligner à l’utilisateur les instructions d’utilisation ou d’entretien importantes contenues dans le manuel qui accompagne l’appareil.
CONSERVEZ CE MANUEL POUR RÉFÉRENCE FUTURE
AVIS
L’utilisation de toute pièce autre que les pièces d’origine STAR dégage le fab­ricant de toute responsabilité.
Star se réserve le droit de changer les spécifi cations et la conception du produit sans préavis. Ces changements ne donnent pas le droit à l’acheteur d’obtenir les changements, améliorations, ajouts ou remplacements correspondants pour l’équipement acheté préalablement.
Dû aux modifi cations périodiques de dessins, méthodes, procédures, règles et régulations, les spécifi cations contenues dans ce manuel sont susceptibles de changer sans préavis. Quoique STAR Manufacturing exerce la bonne foi de fournir le renseignement correct, STAR n’est pas responsable pour les erreurs ou les omissions dans le renseignement pourvu ou les conclusions tirées à la suite de l’utilisation des spécifi cations. En utilisant le renseignement pourvu, l’utilisateur assume tous les risques en relation avec telle utilisation.
ENTRETIEN ET RÉPARATIONS
Contactez votre détaillent local pour les réparations ou l’entretien requis. Assurez-vous d’avoir
le numéro de modèle, le numéro de série, le voltage et la date d’achat pour un service plus
rapide. Entrez l’information requise ci-dessous pour référence rapide.
SYMBOLE DE SÉCURITÉ
N° de modèle
N° de série
Voltage
Date d’achat
Agent de service autorisé
Voir la liste pourvue avec l’appareil Ou
Pour une liste mise à jour voir :
Site web : www.star-mfg.com Courriel : Service@star-mfg.com
1111
DONNÉES GÉNÉRALES D’INSTALLATION
ATTENTION
Ce matériel est conçu et vendu pour l’usage commercial seulement par le personnel qualié et expérimenté en
son exécution et n’est pas vendu pour l’usage du consommateur dans et autour de la maison ni pour l’usage directement par le grand public dans des emplacements de service de traiteur.
Des grils de série d’Ultra-Max sont équipés pour l’usage sur le gaz naturel ou de propane. Toutes les unités sont
expédiées pour le gaz naturel et peuvent facilement être converties en propane. Voir Le Propane Intoxiquer - La
Conversion.
-IMPORTANT-
Soyez sûr d’enlever tout le matériel de papier de protection et d’emballage à partir de l’unité avant l’éclairage.
Éliminez le plastique protecteur du plat de gauffreuse et nettoyez complètement les surfaces extérieures de l’unité.
MAINTENEZ LA RÉGION D’CAppareils LIBRE ET CLAIRE DES COMBUSTIBLES! Pour l’usage sur les
countertops non-combustibles seulement. Le matériel combustible et non-combustible doit être au moins 48 “ (120cm) à partir du dessus de l’appareil et au moins 6 “ (16cm) des côtés et du dos. Le dégagement adéquat devrait également être donné pour l’exécution appropriée et l’entretien.
L’installation de l’appareil doit se conformer au CODE NATIONAL DE GAZ COMBUSTIBLE "ANSI Z223.1 - TOUTE DERNIÈRE ÉDITION" DES
RÉGLEMENTATIONS DE LA COMPAGNIE DE GAZ LOCALE. AU CANADA, L’INSTALLATION DOIT ÊTRE CONFORME AU CODE COURANT D’INSTALLATION
AU GAZ NATUREL CAN/CGA-B149.1 OU AU CODE D’INSTALLATION AU PROPANE CAN/CGA­B149.2 ET AUX CODES LOCAUX, LE CAS ÉCHÉANT.
ÉTATS-UNIS ET À TOUTES LES RÈGLES ET
NOTIFICATION
Quand cet appareil est installé avec des roulettes, il doit être installé avec les roulettes fournies, un connecteur étant conforme à la norme ANSI Z21.69 ou au CAN/CGA-6.16 et à un dispositif rapide étant conforme à la norme ANSI Z21.41 ou au CAN1-6.9. Il doit également être installé avec des moyens retenants de garder contre la transmission de la contrainte au connecteur.
Pour votre propre protection, on vous recommande de faire installer cet appareil par une agence d’installation
qualiée. Ils doivent connaître les installations de gaz et vos exigences de gaz locales. En tout cas, il faut appeler votre société du gaz pour l’approbation de l’installation nale.
Cet appareil, son régulateur de pression et ses vannes d’arrêt individuelles doivent être débranchés de la tuyauterie d’alimentation du gaz lors des essais de pression de la tuyauterie en question à des pressions en dessus de ½ PSIG. Cet appareil et son régulateur de pression doivent être isolés de la tuyauterie d’alimentation du gaz en fermant sa vanne d’arrêt manuelle individuelle lors des essais de pression de la tuyauterie d’alimentation de gaz à des pressions égales à ou de moins que ½ PSIG.
ÉPUISEZ LE BALDAQUIN
Les grils créent en soi beaucoup de la chaleur et de la fumée et devraient être installés sous un capot efcace d’échappement avec des ltres de preuve de amme. Une distance verticale pas moins de de 48 “ sera fournie entre le dessus de l’appareil et les ltres ou n’importe quel autre matériel combustible. L’installation
d’échappement doit se conformer aux codes locaux.
LA PROVISION DE L'AIR
Les vivres pour provision de l'air adéquate doivent être fournis.
ATTENTION
PRISES D’AIR EN BAS
L’air nécessaire à la combustion entre par le bas de l’appareil. Ne bas boucher cette section.
1212
Loading...
+ 28 hidden pages