WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
FOR YOUR SAFETY: Do not store or use
gasoline or other fl ammable vapors or liquids in the vicinity of this or any other appliance.
WARNING: This appliance shall be installed
in accordance with current regulations and used only in well-ventilated space. Refer to instructions before installing and using this
appliance.
In addition, there should be posted, in a prominent location, detailed instructions to be followed in the event the operator smells gas. Obtain the instructions from the local
gas supplier.
1
SAFETY SYMBOL
Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
Star reserves the right to change specifi cations and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the specifi cations contained in this sheet are subject to change without notice. While Star Manufacturing exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifi cations. By using the information provided, the user assumes all risks in connection with such use.
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when you call to
ensure a faster service.
Model No.
Serial No.
Voltage
Purchase Date
Authorized Service Agent
Reference the listing provided with the unit or for an updated listing go to:
Website: www.star-mfg.com E-mail Service@star-mfg.com Telephone: (800) 807-9054 Local (314) 781-2777
The Star Service Help Desk
Business 8:00 am to 4:30 p.m. Central Standard Time Hours:
Telephone: (800) 807-9054 Local (314) 781-2777 Fax: (800) 396-2677 Local (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com Warranty@star-mfg.com
Website: www.star-mfg.com
Mailing Address: Star Manufacturing International Inc.
10 Sunnen Drive St. Louis, MO 63143 U.S.A
2
2
SPECIFICATIONS
8124RCB - Radiant, 8024CB - Lava Rock
Type: Manual Control 4 Controls, 80,000 BTUH (20,000 BTUH Nat/LP per burner) 603 sq. in. (3,890 sq. cm) Grid Area Approximate Weight: Installed - 174 Lb s (78.9 kg), shipping - 240 Lbs (108.9 kg) Dimensions: 24" - Width, 30 5/8" - Depth, 18" - Height (61 cm - Width, 77.8 cm - Depth, 45.7 cm - Height)
8136RCB - Radiant, 8036CB - Lava Rock
Type: Manual Control 6 Controls, 120,000 BTUH Total (20,000 BTUH Nat/LP per burner) 906 sq. in. (5,845 sq. cm) Grid Area Approximate Weight: Installed - 240 Lbs (108.9 kg), shipping - 316 Lbs, (143.3 kg) Dimensions: 36" - Width, 30 5/8" - Depth, 18" - Height (91.4 cm - Width, 77.8 cm - Depth, 45.7 cm - Height)
8148RCB - Radiant, 8048CB - Lava Rock
Type: Manual Control 8 Controls, 160,000 BTUH Total (20,000 BTUH Nat/LP per burner) 1,209 sq. in. (7,800 sq. cm) Grid Area Approximate Weight: Installed - 314 Lbs (142.4 kg), shipping - 398 Lbs, (180.5 kg) Dimensions: 48" - Width, 30 5/8" - Depth, 18" - Height (122 cm - Width, 77.8 cm - Depth, 45.7 cm - Height)
8160RCB - Radiant, 8060CB - Lava Rock
Type: Manual Control 10 Controls, 200,000 BTUH Total (20,000 BTUH Nat/LP per burner) 1,512 sq. in. (9,754 sq. cm) Grid Area Approximate Weight: Installed - 386 Lbs (175.1 kg), shipping - 486 Lbs, (220.4 kg) Dimensions: 60" - Width, 30 5/8" - Depth, 18" - Height (152.4 cm - Width, 77.8 cm - Depth, 45.7 cm - Height)
8172RCB - Radiant, 8072CB - Lava Rock
Type: Manual Control 12 Controls, 240,000 BTUH Total (20,000 BTUH Nat/LP per burner) 1,815 sq. in. (11,710 sq. cm) Grid Area Approximate Weight: Installed - 530 Lbs (240 kg), shipping - 665 Lbs, (301 kg) Dimensions: 72" - Width, 30 5/8" - Depth, 18" - Height (182.9 cm - Width, 77.8 cm - Depth, 45.7 cm - Height)
3
GENERAL INSTALLATION DATA
CAUTION
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations.
The Ultra-Max™ series gas charbroiler is equipped for the type of gas indicated on the nameplate mounted on the front panel. All units are shipped from the factory for use with natural gas. The unit can easily be converted for use with propane gas: see propane gas.
-IMPORTANT­Be sure to remove all paper protection and packing material from unit prior to lighting.
INSTALL IN NON-COMBUSTIBLE LOCATIONS ONLY! Clearance from non­combustible construction must be 3" minimum from back and sides. For servicing, 6" is recommended from back of unit.
The installation of the Appliance must conform to the NATIONAL FUEL GAS CODE "ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/ CGA-B149.2 PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.
NOTICE
When this appliance is installed with casters, it must be installed with the casters supplied, a connector complying with either ANSI Z21.69 or CAN/CGA-6.16 and a quick-disconnect device complying with either ANSI Z21.41 or CAN1-6.9. It must also be installed with restraining means to guard against transmission of strain to the connector, as specifi ed in the appliance manufacturer's instructions.
For your protection, we recommend a qualifi ed installing agency install this appliance. They should be familiar with gas installations and your local gas requirements. In any case, your gas company should be called to approve the fi nal installation.
This appliance, its pressure regulator and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG. This appliance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing
of the gas supply piping system at test pressures equal to or less than 1/2 PSIG.
EXHAUST CANOPY
Open hearth broilers inherently create a good deal of heat and smoke and should be installed under an effi cient exhaust hood with fl ame proof fi lters. A vertical distance of not less than 48" shall be provided between the top of the appliance and fi lters or any other combustible material.
Exhaust installation must conform to local codes.
AIR SUPPLY
Provisions for adequate air supply must be provided.
CAUTION
Air for combustion enters from the bottom of the unit. Do not obstruct this area.
4
LEVELING UNIT
This charbroiler is supplied with 4 feet or fl oor stand legs which must be screwed into the body. Unit must be level. Level unit by adjusting the (4) feet which have an adjustment of 1-3/4" for accurate and perfect line-up with other units.
STIFFENING SUPPORTS ON 8148, 8160, AND 8172 MODELS ONLY
CAUTION
DO NOT INSTALL WITHOUT ATTACHING FEET OR SUPPLIED STAND LEGS AND SHELF - DO NOT REMOVE FEET.
SCREW LEGS INTO MOUNTING NUTS ON BOTTOM
Caster Kits: Casters can be used with fl oor stand models or optional equipment stand. For installation, carefully mark and cut off from the bottom of each leg using a straight cutting saw and de-burr the inside tube wall prior to installing the caster. Cut leg should measure 19" tube length, not overall length. Casters add about 6-1/4" of height to the unit. Be sure to use approved strain relief means for protecting gas line connection. If an appliance is equipped with casters and is gas connected with a quick connect coupling, all personnel must be aware that there is a restraint on the appliance and if disconnected for service or cleaning it must be reconnected as originally installed prior to use.
5
GENERAL INSTALLATION DATA (continued)
PLACING RADIANTS - RCB SERIES
After the unit is unpacked and installed, place 1 radiant above each burner. Install each radiant on 2 slots of the rear wall and on 1 pin of the front wall of the liner weld assembly. Refer to the exploded view in this manual for orientation of the radiants.
PLACING LAVA ROCKS- CB SERIES
Open the lava rock bags and place rock evenly on the lower internal grates - not the top cooking grates. Spread the lava rock evenly on the grates approximately 1 layer thick. Do not cover the grates with more than two layers of lava rock. Do not put more than 5 pounds of rock per burner section.
GAS PIPING
Gas piping shall be of such size and so installed as to provide a supply of gas suffi cient to meet the full gas input of the appliance. If the appliance is to be connected to existing piping, it shall be checked to determine if it has adequate capacity. Joint compound shall be used sparingly and only on the male threads of the pipe joints. Such compounds shall be resistant to the action of L.P. gases. WARNING: Any loose dirt or metal particles which are allowed to enter the gas lines on this appliance will damage the valve and affect its operation. When installing this appliance, all pipe and fi ttings must be free from all internal loose dirt.
GAS PRESSURE REGULATOR
A convertible pressure regulator is provided with each charbroiler. It should be connected to the inlet pipe at the rear of the unit. The gas supply is then connected to it. The supply pressure to the regulator is not to exceed 1/2 PSIG. It is shipped set for 5" water column manifold pressure for use with natural gas.
MANUAL SHUT OFF VALVE
A manual shut off valve should be installed upstream from the manifold and within six feet of the charbroiler.
CONNECTING GAS SUPPLY LINE
The gas inlet of the charbroiler is sealed at the factory to prevent entry of dirt. Do not remove this seal until the actual connection is made to the gas supply line.
PROPANE GAS - CONVERSION
This charbroiler is equipped with fi xed orifi ce hoods and is shipped from the factory for use with natural gas. To convert to propane gas, install the burner orifi ce hoods, located in the water
pan, as follows:
1. Remove grates, radiants and burners.
2. Remove the burner orifi ce hoods and install the orifi ce hoods supplied.
3. Replace the burners, radiants, and grates.
4. Set manifold pressure to (10) inch water column. A 1/8" pipe plug on the burner manifold
can be removed for attaching a pressure gauge. Remove the slotted, or hex-threaded plug from the pressure regulator. Invert the plug and re-install. The letters "LP" should now be visible on the plug. The regulator is now set for 10" (25.4 cm) water column. Attach the conversion label, supplied with the unit, close to the nameplate.
CHECKING FOR GAS LEAKS
Check entire piping system for leaks. Soap and water solution or other material acceptable for the purpose, shall be used in locating gas leakage.
CAUTION
Matches, candle fl ame or other sources of ignition shall not be used for locating gas leaks.