STAR-MAX GAS CHARBROILER

MODELS 6015CBA 6024CBA 6036CBA 6048CBA 6115RCBA 6124RCBA 6136RCBA 6148RCBA

6048 CBA

1

SAFETY SYMBOL

This symbol is intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.

RETAIN THIS MAN UAL FOR FUTURE REFEREN CE

N OTICE

Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.

N OTICE

Star reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.

MAIN TEN AN CE AN D REPAIRS

Contact your local authorized service agent for service or required maintenance. Refer to the authorized service center listing provided with the unit. The Star Service Help Desk (1-800-807-9054) is available during normal businesshoursto answer any questionsthat may arise. Please have your model number and serial number for faster service.

2

GEN ERAL IN STALLATION DATA

CAUTION

This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. For equipment to be used by the general public, please contact the factory.

The Star-Max seriesgascharbroiler isequipped for the type of gas indicated on the nameplate mounted on the front panel. All units are shipped from the factory for use with natural gas. The unit can easily be converted for use with propane gas: see propane gas.

-IMPORTAN T-

IN STALLATION : IN STALL IN N ON -COMBUSTIBLE LO C AT IO N S O N LY! C lear ance fr o m no n- combustible construction must be 6" from back and sides.

The installation of the Appliance must conform to the N ATION AL FUEL GAS CODE "AN SI Z223.1 - LATEST EDITION " AN D ALL LOCAL GAS C O M PAN Y RU LES AN D REGULATION S.

IN CAN ADA IN STALLATIO N SHALL BE IN ACCO RD AN CE W ITH TH E CU RREN T C AN / C GAB149.1 N AT U RAL GAS IN STALLATIO N CO D E O R CAN /CGAB149.2 PROPAN E IN STALLATION CODE AN D LOCAL CODES WHEREAPPLICABLE.

W A RN I N G: Im pr o per inst allat io n, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read t he inst allat io n, o per at ing and maintenance instructions thoroughly before installing or servicing the equipment.

FOR YOUR SAFETY

DO N OT STORE OR USE GASOLIN E OR O T H ER FLAM M ABLE VAPO RS AN D LIQUIDS IN THE VICIN ITY OF THIS OR AN Y O T H ER APPLIAN CE. KEEP T H E APPLIAN CEAREA CLEARAN D FREEFROM COMBUSTIBLES.

This appliance, its pressure regulator and its individual shutoff valve must be disconnected from the gas supply pipingsystem duringany pressure testingof that system at test pressures in excess of 1/2 PSIG. This appliance and its pressure regulator must be isolated from the gassupply pipingsystem by closingitsindividual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or lessthan 1/2 PSIG. For your protection, we recommend a qualified installing agency install this appliance. They should be familiar with gas installations and your local gas requirements. In any case, your gas company should be called to approve the final installation. In addition, there should be posted, in a prominent location, detailed instructions to be followed in the event the operator smells gas. Obtain the instructions from the local gas supplier.

LEVELIN G UN IT

This charbroiler is supplied with 4 feet which must be screwed into the body. Level unit by adjusting the (4) feet which have an adjustment of 1-3/4" for accurate and perfect line-up with other units.

CAUTION

DO N OT IN STALL WITHOUT ATTACHIN G FEET - DO N OT REMOVE FEET.

GAS IN PUT TO CHARBROILER:

Models 6015CBA and 6115RCBA 25,000 BTU/HR Models 6024CBA and 6124RCBA 50,000 BTU/HR

25,000 BTU/HR/BURN ER Models 6036CBA and 6136RCBA 75,000 BTU/HR

25,000 BTU/HR/BURN ER Models 6048CBA and 6148RCBA 100,000 BTU/HR

25,000 BTU/HR/BURN ER