Using any part other than genuine Star factory supplied parts relieves the
manufacturer of all liability.
Star reserves the right to change specifi cations and product design without
notice. Such revisions do not entitle the buyer to corresponding changes,
improvements, additions or replacements for previously purchased
equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specifi cations contained in this sheet are subject to change
without notice. While Star Manufacturing exercises good faith efforts to provide
information that is accurate, we are not responsible for errors or omissions
in information provided or conclusions reached as a result of using the
specifi cations. By using the information provided, the user assumes all risks in
connection with such use.
These symbols are intended to alert the user to the presence of
important operating and maintenance instructions in the manual
accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model
number, serial number, voltage and purchase date in the area below and have it ready when you call to
ensure a faster service.
Model No.
Serial No.
Voltage
Purchase Date
Authorized Service Agent
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com
E-mail Service@star-mfg.com
Telephone: (800) 807-9054 Local (314) 781-2777
The Star Service Help Desk
Business 8:00 am to 4:30 p.m. Central Standard Time
Hours:
Telephone: (800) 807-9054 Local (314) 781-2777
Fax: (800) 396-2677 Local (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com
Warranty@star-mfg.com
Website: www.star-mfg.com
Mailing Address: Star Manufacturing International Inc.
10 Sunnen Drive
St. Louis, MO 63143
U.S.A
2
GENERAL INSTALLATION DATA
CAUTION
This equipment is designed and sold for commercial
use only by personnel trained and experienced in its
operation and is not sold for consumer use in and
around the home nor for use directly by the general
public in food service locations. For equipment to be
used by the general public, please contact the factory.
This gas appliance is equipped for the types of gas
indicated on the nameplate mounted on the front
panel. It is shipped adjusted for use on natural gas.
The installation of the Appliance should conform to
the NATIONAL FUEL GAS CODE "ANSI Z223.1 LATEST EDITION" AND ALL LOCAL GAS
COMPANY RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN
ACCORDANCE WITH THE CURRENT CAN/CGAB149.1 NATURAL GAS INSTALLATION CODE OR
CAN/CGA-B149.2 PROPANE INSTALLATION
CODE AND LOCAL CODES WHERE APPLICABLE.
This appliance, its pressure regulator and its individual
shutoff valve must be disconnected from the gas
supply piping system during any pressure testing of
that system at test pressures in excess of 1/2 PSIG.
This appliance and its pressure regulator must be
isolated from the gas supply piping system by closing its
individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures
equal to or less than 1/2 PSIG. For your protection, we
recommend a qualified installing agency install this
appliance. They should be familiar with gas installations
and your local gas requirements. In any case, your gas
company should be called to approve the final
installation. In addition, there should be posted, in a
prominent location, detailed instructions to be followed
in the event the operator smells gas. Obtain the
instructions from the local gas supplier.
LEVELING UNIT
Units are shipped with feet detached. To attach feet,
remove the grates, lay unit on it's side and screw feet
into sockets on bottom. Level unit by adjusting the (4)
feet which have an adjustment of 1-3/4" for accurate
and perfect line-up with other Star-Max series units.
CAUTION
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause
property damage, injury or death. Read the
installation, operating and maintenance instructions
thoroughly before installing or servicing the
equipment.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
KEEP THE APPLIANCE AREA CLEAR AND FREE
FROM COMBUSTIBLES.
DO NOT REMOVE FEET.
GAS PIPING
Gas piping shall be new, clean and of such size and so
installed as to provide a supply of gas sufficient to meet
the full gas input of the appliance. If the appliance is to
be connected to existing piping, it shall be checked to
determine if it has adequate capacity. Joint compound
(pipe dope) shall be used sparingly and only on the
male threads of the pipe joints. Such compounds shall
be resistant to the action of L.P. gases. WARNING:
Any loose dirt or metal particles which are allowed to
enter the gas lines on the appliance will damage the
automatic valve and affect its operation. When installing
this appliance, all pipe and fittings must be free from all
internal loose dirt.
3
CLEARANCE
Minimum wall clearances for the sides and back of the
models contained in this manual shall be as follows:
EXHAUST CANOPY
It is essential that facilities be provided to carry off
fumes and gases.
CombustibleNon-Combustible
WallWall
Hotplates9"0"
Stock Pot Range14"0"
PRESSURE REGULATOR
A convertible pressure regulator set at 6" water
column for use on natural gas is furnished. (For LP
models the regulator is set for 10" water column
pressure.) Attach the regulator to the supply pipe,
located at the back of the unit, make sure gas flow
arrow on regulator is pointing towards manifold. The
gas supply is then connected to the regulator. A 1/8"
tap is furnished on the manifold for checking pressure.
The manifold is accessible by removing the front panel.
MANUAL SHUT OFF VALVE
A manual shut off valve should be installed upstream
from the unit and within six feet of the appliance, and
is not provided.
CONNECTING GAS SUPPLY LINE
The gas inlet on this appliance is sealed at the factory
to prevent entry of dirt. Do not remove this seal until
the actual connection is made to the gas supply line.
CHECKING FOR GAS LEAKS
Soap and water solution or other material acceptable
for the purpose, shall be used in locating gas leakage.
Matches, candle flame or other sources of ignition
shall not be used for this purpose.
AIR SUPPLY
Provisions for adequate air supply must be furnished.
AIR INTAKES IN BOTTOM
Make certain the air intake openings in the bottom of
the appliance are not obstructed. They are essential
for proper combustion and operation of the appliance.
GAS INPUT OF OPEN TOP RANGES
For Natural Gas: All models except 601SPRD-22,000
BTU/HR for each burner. Model 601SPRD-55,000
BTU/HR for each burner. Regulator output pressure
set at 6" water column.
For Propane Gas: All models except 601SPRD-22,000
BTU/HR for each burner. Model 601SPRD-45,000
BTU/HR for each burner. Regulator output pressure
set at 10" water column.
Note: The appliance is equipped with natural gas
orifice hoods. A separate set of hoods will be provided
for use on propane gas. The propane hoods are
located on the front panel. Factory set LP models do
not include the natural gas hoods.
LIGHTING INSTRUCTIONS
The appliance is equipped with standing pilots; each
pilot is located in front of the burner on Models
602HD, 602HWD, 602HDS and 606HD. On Models
602HD-SU, 604HD-SU and 606HD-SU the pilots for
the front burners are located in front of the burners,
on the rear burners pilots are located on the side of the
burners. On Model 601SPRD, the pilots are located
on the right side of each burner. Pilots should be
lighted immediately after the gas is turned on by the
manual shutoff valve.
1. Turn control knobs to "OFF" position.
2. Light pilot with a lighted taper.
3. The pilot valves are located on the manifold installed
at the front of the unit behind the front panel. For
access to the valves, remove the front panel,
which is attached to the frame with 4 sheet metal
screws. Turn the adjustment screws on the front
of the pilot valves. The pilots should be adjusted to
a nice, blue short flame (1/4" high) to have good
ignition to the burners.
4. If the pilot(s) is out turn off gas, wait 5 minutes and
repeat steps (1) through (3).
5. Install the front panel to the front of the frame.
4
ADJUSTING BURNERS
Remove front panel in order to gain access to the
primary air shutters. With control valve for the front
burner turned to full "ON" position, close the air
shutters to give a soft blue flame having luminous tips
and open to a point where the yellow tips disappear,
then tighten the locking screws. Repeat this procedure
with the rear burner.
ADJUSTING UNIT FOR USE ON PROPANE
GAS
Units are shipped with orifices and pressure regulator
for operation with natural gas (6" water column). To
convert unit from natural to propane gas follow these
instructions (Note: LP models are factory set for
propane gas and do not require a conversion. these
can be converted to natural gas using the natural gas
orifices and converting the regulator to natural gas):
1. Set regulator outlet pressure to 10" water column.
A 1/8" pipe plug on the manifold can be removed
for attaching a pressure gauge.Remove the
slotted cover from the pressure regulator and
invert the plug. Replace the cover on the regulator
and plug on the manifold. Regulator is now set at
10" W.C.
2. Remove natural gas orifices, #46 for all models
except 601SPRD, #.125 for 601SPRD, and install
propane orifices, painted black, (#54 for all models
except 601SPRD, #45 for 601SPRD) located in a
bag on the outside of the front panel. In order to
remove natural gas orifices:
a. Remove grates and burners.
b. Remove orifices from the manual valves and
from fittings on extended gas pipes, replace
with the propane orifices.
c. Install burners and grates.
OPERATING PROCEDURE
Each burner will deliver up to 22,000 BTU/HR of heat
on all models except 601SPRD (on 601SPRD each
burner is rated 55,000 BTU/HR for natural gas and
45,000 BTU/HR for propane) and is controlled by a
manual On/Off valve. The right control knob controls
the front burner and the left control knob controls the
rear burner on all models except 601SPRD. On the
601SPRD, the right control knob controls the inner
burner and the left control knob controls the outer
burner. After the pilot is once lit and adjusted, the
burners will ignite automatically by turning the control
knob to any position between On and Off.
CLEANING THE EXTERIOR (Stainless Steel
Only)
The exterior surface can be kept clean and attractive
by regularly wiping it with a clean soft cloth. Any
discoloration can be removed with a non-abrasive
cleaner. The burner grates and trough tray can be
removed for cleaning.
MAINTENANCE AND REPAIRS
Contact the factory or one of its representatives or a
local service company for service or maintenance if
required.