STAR-MAX GAS CHARBROILER
MODELS
6015CBSB, 6024CBSB, 6036CBSB,
6124RCBSB, and 6136RCBSB
6024CBSB
1
SAFETY SYMBOL
This symbol is intended to alert the user to the presence of important
operating and maintenance instructions in the manual accompanying
the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
Using any part other than genuine Star factory supplied parts relieves
the manufacturer of all liability.
NOTICE
Star reserves the right to change specifications and product design
without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for
previously purchased equipment.
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Refer to the authorized service
center listing provided with the unit. The Star Service Help Desk (1-800-807-9054) is available during normal
business hours to answer any questions that may arise. Please have your model number and serial number for faster
service.
2
GENERAL INSTALLATION DATA
CAUTION
This equipment is designed and sold for commercial
use only by personnel trained and experienced in its
operation and is not sold for consumer use in and
around the home nor for use directly by the general
public in food service locations. For equipment to be
used by the general public, please contact the factory.
The Star-Max series gas charbroiler is equipped for the
type of gas indicated on the nameplate mounted on
the front panel. All units are shipped from the factory
for use with natural gas. The unit can easily be converted
for use with propane gas: see propane gas.
-IMPORTANT-
INSTALLATION: INSTALL IN NON-COMBUSTIBLE
LOCATIONS ONLY! Clearance from noncombustible construction must be 6" from back and
sides.
The installation of the Appliance must conform
to the NATIONAL FUEL GAS CODE "ANSI
Z223.1 - LATEST EDITION" AND ALL LOCAL
GAS COMPANY RULES AND
REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN
ACCORDANCE WITH THE CURRENT
CAN/CGA-B149.1 NATURAL GAS
INSTALLATION CODE OR CAN/CGAB149.2 PROPANE INSTALLATION CODE
AND LOCAL CODES WHERE APPLICABLE.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR
OTHER FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE. KEEP THE
APPLIANCE AREA CLEAR AND FREE FROM
COMBUSTIBLES.
This appliance, its pressure regulator and its individual
shutoff valve must be disconnected from the gas
supply piping system during any pressure testing of that
system at test pressures in excess of 1/2 PSIG. This
appliance and its pressure regulator must be isolated
from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the
gas supply piping system at test pressures equal to or
less than 1/2 PSIG. For your protection, we recommend
a qualified installing agency install this appliance. They
should be familiar with gas installations and your local
gas requirements. In any case, your gas company
should be called to approve the final installation. In
addition, there should be posted, in a prominent
location, detailed instructions to be followed in the
event the operator smells gas. Obtain the instructions
from the local gas supplier.
LEVELING UNIT
This charbroiler is supplied with 4 feet which must be
screwed into the body. Level unit by adjusting the (4)
feet which have an adjustment of 1-3/4" for accurate
and perfect line-up with other units.
CAUTION
DO NOT INSTALL WITHOUT ATTACHING
FEET - DO NOT REMOVE FEET.
WARNING: Improper installation,
adjustment, alteration, service or maintenance
can cause property damage, injury or death.
Read the installation, operating and
maintenance instructions thoroughly before
installing or servicing the equipment.
GAS INPUT TO CHARBROILER:
Models 6015CBSB:
40,000/35,000 BTU/HR NAT/PROP
Models 6024CBSB and 6124RCBSB:
80,000/70,000 BTU/HR NAT/PROP
40,000/35,000 BTU/HR/BURNER NAT/PROP
Models 6036CBSB and 6136RCBSB:
120,000/105,000 BTU/HR NAT/PROP
40,000/35,000 BTU/HR/BURNER NAT/PROP
3